• 제목/요약/키워드: PIV Measurement

Search Result 359, Processing Time 0.021 seconds

Application of PIV to Fluid-Machinery Studies (유체기계연구에서의 PIV의 적용)

  • Lee, Y. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1997.02a
    • /
    • pp.188-195
    • /
    • 1997
  • The application of PIV to the studies of fluid-machines, especially focused on turbo-machinery is reviewed by scrutinizing the previous investigation. Owing to the inevitable high-speed analysis of turbo-machinery consisting of rotating impellers, the importance of optical setups to cope with illumination problem is frequently mentioned as main ingredient affecting the PIV performance. And the acquisition of the relative velocity and absolute velocity is determined mainly by the optical recording conditions. A few studies cast satisfactory extension of the PIV data to quantitative pressure estimation and related noise assessment.

  • PDF

Development of a Stereoscopic Miniature PIV(MPIV) System (Stereoscopic Miniature PIV (MPIV) 시스템의 개발)

  • Kim S.H.;Chete1at O.;Kim K.C.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.517-520
    • /
    • 2002
  • Stereoscopic particle image velocimetry is a measurement technique to acquire of three dimensional velocity field by two cameras. With a laser sheet illumination, the third velocity component can be deduced by out-of-plane velocity components using a stereoscopic matching method. Industrial fluid flows are almost three dimensional turbulent flows, so it is necessary to use the stereoscopic PIV measurement method. However the existing stereoscopic PIV system seems hard to use since it is very expensive and complex. In this study we have developed a Stereoscopic Miniature PIV(MPIV) system based on the concept of the Miniature PIV system which we have already developed. In this paper, we address the design and some first experimental results of the stereoscopic PIV system. The Stereoscopic MPIV system features relatively modest performances, but is considerably smaller, cheaper and easy to handle. The proposed Stereoscopic MPIV system uses two one-chip-only CMOS cameras with digital output. Only two other chips are needed, one for a buffer memory and one for an interfacing logic that controls the system. Images are transferred to a personal computer (PC) via its standard parallel port. No extra hardware is required (in particular, no frame grabber board is needed).

  • PDF

Simultaneous Measurement of Fluid Velocity and Particle Velocity in a Particle-Containing Fluid Flow (입자가 포함된 유동장에서 유체속도와 입자속도의 동시 측정기법)

  • Jin Dong-Xu;Lee Dae-Young;Lee Yoon-Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.355-363
    • /
    • 2005
  • A novel method for simultaneously measuring the fluid velocity and the large particle velocity in a particle-containing fluid flow is developed in this study. In this method, the fluid velocity and the large particle velocity are measured by PIV and PTV, respectively. The PIV and PTV images are obtained from the same flow images. Since a PIV result represents the average displacement of all particles in an interrogation area, it will include an error caused by the relative displacement between the large particles and the fluid. In order to reduce the false influence of large particles on the PIV calculation, the mean brightness of small PIV particle images is substituted to the locations of large particles in the PIV images. The simulation results showed that the new method significantly reduces the PIV error caused by the large particles even at the case where the large particles occupy area fraction as large as $20\%$ of the full image.

Numerical Simulation and PIV Measurement on the Internal Flow in a Centrifugal Mini Pump at Low Flow Rate Conditions

  • Yuan, Hui-Jing;Shao, Jie;Cao, Guang-Jun;Liu, Shu-Hong;Wu, Yu-Lin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.775-780
    • /
    • 2008
  • This paper reports on the internal flow of a centrifugal mini pump working at the low flow rate operating conditions. The RNG $\kappa-\varepsilon$ turbulence model was employed to simulate the three-dimensional turbulent flow in the pump. To examine and certify the simulation results, a transparent acrylic centrifugal mini pump model which is suitable for PIV measurement has been developed. The tongue region and the passages region between blades were investigated using PIV. In order to eliminate the effect of refraction on the area closed to the wall and increase the measurement accuracy, the fluorescent particles were scatted into the working fluid with the tracing particles. It is found from the calculation and PIV measurement results that there is a large area of recirculation flow near the tongue at low flow rate operating conditions. The computationally predicted water head using the $\kappa-\varepsilon$ turbulence model at low flow rate operating conditions are in very good agreement with the experimentally measured water head and the mean velocity distributions at investigation area obtained by PIV and calculation showed a satisfactory agreement as well. Meanwhile, the results of PIV measurements show that the flow status in one passage is different to another. And for capturing the internal flow detail information, the $\kappa-\varepsilon$ turbulence model is not very suitable.

  • PDF

PIV Measurement of Inlet and Outlet Flow of Contra-Rotating Small-Sized Cooling Fan

  • Shigemitsu, Toru;Fukuda, Hiroaki;Fukutomi, Junichiro
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.2
    • /
    • pp.175-181
    • /
    • 2016
  • Contra-rotating rotors have been adopted for some of the cooling fans to meet the demand for the high pressure and large flow rate. Therefore, it is important to clarify its inlet and outlet flows by experiments for the high performance and stable operation. PIV measurements were conducted at the design and partial flow rates. In the present paper, the inlet and outlet flow conditions of the contra-rotating small-sized cooling fan with a 40mm square casing are studied by using PIV measurement. Furthermore, improvements of the flow condition and design guideline to increase the performance were discussed based on the experimental results.

Micro-PIV Measurement of Water/Oil Two Phase Flow in a Y-Junction Microchannel (Y형 마이크로채널에서의 물/기름 2상 유동에 대한 Micro-PIV 측정)

  • Yoon,Sang-Youl;Ko, Choon-Sik;Kim, Kyung-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.6
    • /
    • pp.682-687
    • /
    • 2004
  • Y-junction microchannels are widely used as a flew mixer. Fluids are entered from two branch channels and merged together at a combined channel. In this study, we suggest a simple method to create the fluid digitization using flow instability phenomena. Two immiscible liquids (water/oil) are infused continuously to each Y-junction inlets. Because of the differences in fluid and flow properties at the interface, oil droplet is formed automatically followed by flow instability. In order to clarify the hydrodynamic aspects involved in oil droplet formation, a quantitative flow visualization study has performed. Highly resolved velocity vector fields are obtained by a micro-PIV technique, so that detail flow structures around the droplet are illustrated. In this study, fluorescent particles were mixed with water only for visualization of oil droplet and velocity field measurement in water flow.

Measurements of Temperature and Flow Fields with Sub-Millimeter Spatial Resolution Using Two-Color Laser Induced Fluorescence (LIF) and Micro-Particle Image Velocimetry (PIV)

  • Kim Hyun Jung
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.716-727
    • /
    • 2005
  • Comprehensive measurements for velocity and temperature fields have been conducted. A Micro PIV 2-color LIF system have been setup to measure the buoyancy driven fields in a 1-mm heated channel with low Grashof-Prandtl numbers [$86]. Fluorescence microscopy is combined with an MPIV system to obtain enough intensity images and clear pictures from nano-scale fluorescence particles. The spatial resolution of the Micro PIV system is $75{\mu}m\;by\;67{\mu}m$ and error due to Brownian motion is estimated $1.05\%$. Temperature measurements have achieved the $4.7\;{\mu}m$ spatial resolution with relatively large data uncertainties the present experiment. The measurement uncertainties have been decreased down to less than ${\pm}1.0^{\circ}C$ when measurement resolution is equivalent to $76\;{\mu}m$. Measured velocity and temperature fields will be compared with numerical results to examine the feasibility of development as a diagnostic technique.

A PIV Measurement on Flow Characteristics inner Diffuser Pump Using High Resolution CCD Camera (고해상도 CCD 카메라를 이용한 디퓨져펌프 내부 유동특성에 대한 PIV 계측)

  • 김성윤;김범석;김정환;김유택;이영호
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.161-166
    • /
    • 2002
  • The resent experimental study is focused on the application of multi-point simultaneous measurement by PIV Particle Image Velocimetry) to guide vane region within diffuser pump. Various different kinds of rotational veto ity and changing clearance between Guide Vane and Impeller were selected as experimental condition. Optimized ross correlation identification to obtain velocity vectors is implemented with direct calculation of correlation coeffi cients. Fine optical setup concerned with PW performance is arranged for the accurate PW measurement of high peed complex flow. Variable flow pattern are represented quantitatively at the stator region.

  • PDF

A Study on Bubbly Flow using PIV Measurement (PIV 법을 이용한 기포유동에 관한 연구)

  • 배대석;권오봉
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.898-903
    • /
    • 2001
  • The particle image velocimetry with liquid crystal tracers is used for visualizing and analysis of the bubbly flow in a vertical temperature gradient. This method allows simultaneous measurement of velocity and temperature field at a given instant of time Quantitative data of velocity were obtained by applying the MQD technique to visualized image. The paper describes the method, and presents the transient velocity patterns of bubbly flow.

  • PDF

Measurement and Analysis on the Mixing Flows in a Tank with a Bottom Agitator using a Hybrid Volume Measurement Technique (하이브리드 볼륨측정법에 의한 하부교반 탱크내 혼합유동 측정 및 해석)

  • Doh, Deog Hee;Lee, Chang Jae;Baek, Tae Sil
    • Journal of the Korean Society of Visualization
    • /
    • v.10 no.3
    • /
    • pp.42-47
    • /
    • 2012
  • Experimental data for the flows in a mixing tank with a bottom agitator are useful for the validation of CFD commercial code. A hybrid volume PIV measurement technique was constructed to measure the flows inside of the mixing tank. The measurement system consists of three cameras. An agitator was installed at the bottom of the tank and it rotates clockwise and counterclockwise. Using the constructed measurement system, instantaneous vector fields were obtained. A phase averaging technique was adopted for the measured instantaneous three-dimensional velocity vector fields. Turbulent properties were evaluated from the instantaneous vector fields.