• Title/Summary/Keyword: PIN Diode

Search Result 165, Processing Time 0.029 seconds

Double Square Patch Antenna with Inductive Bridges for WLAN Dual-Band (인덕티브 브릿지를 가진 WLAN 이중 대역 이중 사각 패치 안테나)

  • Yang, Chan-Woo;Jung, Chang-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2615-2618
    • /
    • 2009
  • Double rectangular patch with 4-bridges is investigated for solution of IEEE 802.11b/g (2.4 GHz) and 802.11a (5.5 GHz). Rectangular patch for 5.5 GHz frequency band is printed on the PCB substrate and connected to another rectangular patch for 2.4 GHz frequency band with 4-bridges to obtain dual band operation in an antenna element. 4-bridges can modify the desired frequency band from its original frequency band by changing its width. Gain of 2.4 GHz patch is 5 dBi and 5.5 GHz patch is 3.7 dBi at ${\theta}=0^{\circ}$.

Optimization of Broadband Antenna Parasitic Elements for TACAN (TACAN용 광대역 안테나 기생소자 최적화)

  • Park, Sang Jin;Koo, Kyung Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.5
    • /
    • pp.483-491
    • /
    • 2015
  • This paper describes the design optimization of parasitic elements used for TACAN broadband antenna. We deployed parasitic elements arranged in a circular array to electronically rotate the antenna instead of employing a mechanically rotated antenna to generate the composite radiation pattern of 15 Hz and 135 Hz including bearing information and to meet the harmonic contents specification of MIL-STD-291C. We performed the simulation for optimization of the parasitic elements and fabricated the antenna composed of 16 parasitic elements of 15 Hz and 63 parasitic elements of 135 Hz. With harmonics magnitude reduction by increasing the number of steps using vector composition of the reflectors, the measured result meets the specification of MIL-STD-291C.

Wideband Frequency Tunable Metamaterial Absorber Using Switchable Ground Plane (그라운드를 전환하여 주파수를 가변할 수 있는 광대역 메타물질 흡수체)

  • Jeong, Heijun;Lim, Sungjoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.241-246
    • /
    • 2018
  • In this study, we proposed a wideband frequency tunable metamaterial absorber using a switchable ground plane (SGP). We proposed two fire retardant or flame resistant 4 (FR4) substrate structures for the SGP. An SGP is placed at the middle layer, between the top pattern and the bottom ground plane. The SGP can either be made ground or reactive, by switching the PIN diode ON/OFF. As the frequency is determined by the substrate thickness, the frequency can be switched from the SGP. The proposed absorber is demonstrated by full-wave simulations and measurements. When the SGP is turned on, an absorptivity higher than 90% is achieved from 3.5 GHz to 11 GHz. When the SGP is turned off, an absorptivity higher than 90 % is achieved from 1.7 GHz to 5.2 GHz.

The Deduction of the Optimal Length to Width Ratio of Dye-sensitized Solar Cell and the Fabrication of a Module (가로-세로 비율에 따른 염료감응형 태양전지의 최적 조건 도출 및 모듈 제조)

  • Kim, Hee-Je;Park, Sung-Joon;Choi, Jin-Young;Seo, Hyun-Woong;Kim, Mi-Jeong;Lee, Kyoung-Jun;Son, Min-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.100-106
    • /
    • 2009
  • A novel 8 V DC power source with an external series-parallel connection of 50 Dye-sensitized Solar Cells (DSCs) has been proposed. One DSC has the optimized length to width ratio of $5.2{\times}2.6\;cm$ and an active area $8\;cm^2$ ($4.62{\times}1.73\;cm$) which attained a conversion efficiency of 4.02%. From the electrochemical impedance spectroscopic analysis, it was found that the resistance elements related to the Pt electrode and electrolyte interface behave like that of diode and the series resistance corresponds to the sum of the other resistance elements. Surface morphology and sheet resistance of Pt counter electrode did not degrade the performance of the cell. This novel 8V-0.33A DC power source shows stable performance with an energy conversion efficiency of 4.24% under 1 sun illumination (AM 1.5, Pin of $100\;mW/cm^2$).

Pulse Radiation Dose Measurement using the Peak Detector (Peak Detector를 이용한 펄스방사선 선량 측정)

  • Jeong, Sang-hun;Lee, Nam-ho;Oh, Seong-chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.1020-1022
    • /
    • 2013
  • In this paper, proposed peak detector for the measurement of pulse radiation dose. The speed of the pulse radiation signal is the between a few ns and tens ns. Therefore, it is difficult to measure peak voltage. Peak Detector maintains the peak voltage generated from the sensor for a few ms and the converted signals can be easily measured using the ADC. The peak detector simulation results peak value remained of more than 1ms. Pulse radiation irradiation test results, a dose of $1.95{\times}10^6rad/s$ was measured.

  • PDF

CHARACTERISTICS OF FABRICATED SiC RADIATION DETECTORS FOR FAST NEUTRON DETECTION

  • Lee, Cheol-Ho;Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Park, Hyeon-Seo;Kim, Gi-Dong;Park, June-Sic;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.70-74
    • /
    • 2012
  • Silicon carbide (SiC) is a promising material for neutron detection at harsh environments because of its capability to withstand strong radiation fields and high temperatures. Two PIN-type SiC semiconductor neutron detectors, which can be used for nuclear power plant (NPP) applications, such as in-core reactor neutron flux monitoring and measurement, were designed and fabricated. As a preliminary test, MCNPX simulations were performed to estimate reaction probabilities with respect to neutron energies. In the experiment, I-V curves were measured to confirm the diode characteristic of the detectors, and pulse height spectra were measured for neutron responses by using a $^{252}Cf$ neutron source at KRISS (Korea Research Institute of Standards and Science), and a Tandem accelerator at KIGAM (Korea Institute of Geoscience and Mineral Resources). The neutron counts of the detector were linearly increased as the incident neutron flux got larger.

Design and Fabrication of Switchable VCO for DECT Handset (DECT 단말기용 Switchable VCO 설계 및 제작)

  • 김상태;황수설;류준규;홍성용;이재명
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.4
    • /
    • pp.634-641
    • /
    • 2000
  • A switchable VCO for DECT handset is designed and fabricated. In dual mode radios, a single VCO is desired to operate at two different frequencies to meet the requirement of two mode(Tx, Rx). The three design types of switchable VCO are switched resonator VCO, switched mode VCO and dual band VCO. In this paper, we use the switched resonator VCO type using pin diode switch to change the total amount of capacitance in the tank circuit. At the bias condition of 3 V and 13mA, the output power and phase noise are better than6.5dBm and -104dBc/Hz at 25khz offset from the carrier, respectively , across the operating frequency range. From these results, the fabricated switched VCO is applicable to the DECT handset.

  • PDF

Design of Ku-band Channel Amplifier Engineering Model for Communication and Broadcasting Satellite Payload (통신방송위성 중계기용 Ku-대역 채널증폭기 시험 모델 설계)

  • 장병준;염인복;이성팔
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.982-988
    • /
    • 2002
  • This paper summarizes the design concepts and implementation of a Ku-band channel amplifier's engineering model for the communication and broadcasting satellite applications. The selected architecture uses the analog gain control for the FGM(Fixed Gain Mode) and the output level limiting using automatic loop control for the ALC (automatic level control) mode. The Ku-band channel amplifier incorporates several state-of-the-art components including voltage-controlled PIN diode attenuators, and various temperature-compensation circuits. The measured characteristics of the Ku-band channel amplifier are in good agreement with the expected performance. The results show a fixed gain control of 28 dB, and an automatic level control of 16 dB over operating temperature range. The designed engineering model could be used as a channel amplifier for Ku-band communication and broadcasting satellite payload system.

2 Bits MMIC Phase Shifter Improving the Phase Characteristic (위상특성을 개선시킨 2 Bits MMIC 위상변위기)

  • 정명득
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.9
    • /
    • pp.392-397
    • /
    • 2003
  • Reflection type phase shifter with Lange coupler is widely used as a circuit topology to obtain phase shift in broadband operation. The phase shift of 33.75$^{\circ}$ at this type is achieved by simultaneously turning on both 11.25$^{\circ}$ and 22.5$^{\circ}$ . In order to improve the phase accuracy of 33.75$^{\circ}$, this paper proposes the additional circuit which is composed of a GaAs PIN diode and a reactive load. By utilizing MMIC technology. Over the 2-6 GHz band, the measured result of phase difference between the previous circuit and the proposed circuit shows average 4.7$^{\circ}$ on the basis of 33.75$^{\circ}$. Insertion loss and return loss are invariant in comparison with the previous circuit.

Development of Measurement System for Industrial Transportable Gamma Ray CT (이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.