• Title/Summary/Keyword: PID Feedback

Search Result 275, Processing Time 0.027 seconds

Vibration Control of A CPM Maglev System (CPM형 자기부상의 진동제어)

  • Kim Jong-Moon
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1001-1003
    • /
    • 2004
  • In this paper, the vibration control of CPM(Controlled-Permanent Magnet) type magnetic levitation system of 1ton is designed and implemented. The target to be controlled has 8 magnets and 4 corners of the maglev module are levitated using a digital feedback controller. The designed controller includes PID type gap controller and speed observer. Its performance is validated by some kinds of experiments.

  • PDF

A Fuzzy-Logic Controller for an Electrically Driven Steering System for a Motorcar

  • Lee, Sang-Heon;Kim, Il-Soo;Jayantha katupitiya
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.8
    • /
    • pp.1039-1052
    • /
    • 2002
  • This paper presents an application where a Fuzzy-Logic Controller (FLC) is used at a supervisory level to implement mutual coordination of the steering of the two front wheels of a motorcar. The two front wheels are steered by two independent discrete time state feedback controllers with a view to optimize the steering slip angles. The functions of the two controllers are tied together by way of a FLC. Because of the presence of unmodelled dynamics and disturbances acting on the two sides, it is difficult to achieve the desired performance using conventional control systems. This is the primary reason that FLC is emploged to solve the problem. The results show that the implemented system achieved desired coupling between the two independent systems and thereby reduces the difference between the two steered angles.

A Note on Relay Feedback Identification Under Static Load Disturbances

  • Kaya, Ibrahim
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.395-400
    • /
    • 2015
  • Obtaining the parameters for PID controllers based on limit cycle information for the process in a relay controlled feedback loop has become an accepted practical procedure. If the form of the plant transfer function is known, exact expressions for the limit cycle frequency and amplitude can be derived so that their measurements, assumed error free, can be used to calculate the true parameter value. In the literature, parameter estimation for an assumed form of the plant transfer function has generally been considered for disturbance free cases, except a recently published work of the author. In this paper additional simulation results are reported on exact parameter estimation from relay autotuning under static load disturbances.

Positioning control of pzt actuators using neuro control with hysteresis model (ICCAS 2003)

  • Lee, Byung-Ryong;Lee, Soo-Hee;Yang, Soon-Yong;Ahn, Kyung-Kwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.382-385
    • /
    • 2003
  • In this paper, in order to improve the control performance of piezoelectric actuator, an integrated control structure is proposed. The control structure consists of inverse hysteresis model , to compensate the hysteresis nonlinearty problem, and feedforward - feedback controller to give a good tracking performance. The inverse hysteresis model and neural network are used as feed-forward controller, and PID controller is used as a feedback controller. From diverse experiments it is concluded that the proposed control scheme gives good tracking performance than the classical control does.

  • PDF

Modeling and experiment for the force/impact control via passive hardware damper

  • Oh, Y.H.;Chung, W.K.;Youm, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.172-178
    • /
    • 1993
  • This paper deals with the modeling and experiment of a robot system for force/impact control performance. The basic model is composed of a direct drive motor, servo amplifier, link, force sensor and environments. Based on the developed model, the stability of the whole system was analyzed via root locus method. For the force control, integral force compensation with velocity feedback method shows the best performance of all the explicit force control strategies. In dealing with impact, PID position control and the explicit force control method were implemented. Instead of add more damping to the robot system by velocity feedback, we developed a new passive damping method and it was also applied to enhance the damping characteristic of the system.

  • PDF

A study on the speed controller for D.C servo motor using expert control technique in variable (가변 부하시 전문가 제어 기법을 이용한 직류 서보 전동기의 속도제어기에 관한 연구)

  • Yoon, Yang-Woung;Park, Wal-Seo;Oh, Hun
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.34-36
    • /
    • 1991
  • The idea of expert control is to incoporate a rule based expert system in a feedback control system. In this paper, we present some heuristic rules about input requlation and supervision and turning for D.C servo motor speed control in variable. The expert auto-turning PID controller which heuristic rules are used as an element of the feedback control system is implemented with the numerical algorithms and heuristic logics. The accurate control function is confirmed by computer simulation.

  • PDF

Precision Position Control System of Piezoelectric Actuator Using Inverse Hysteresis Modeling and Error Learning Method (역 히스테리시스 모델링과 오차학습을 이용한 압전구동기의 초정밀 위치제어)

  • 김형석;이수희;정해철;이병룡;안경관
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.383-388
    • /
    • 2004
  • A piezoelectric actuator yields hysteresis effect due to its composed ferroelectric. Hysteresis nonlinearty is neglected when a piezoelectric actuator moves with short stroke. However when it moves with long stroke and high frequency, the hysteresis nonlinearty can not be neglected. The hysteresis nonlinearty of piezoelectric actuator degrades the control performance in precision position control. In this paper, in order to improve the control performance of piezoelectric actuator, an inverse modeling scheme is proposed to compensate the hysteresis nonlinearty problem. And feedforward - feedback controller is proposed to give a good tracking performance. The Feedforward controller is inverse hysteresis model, Nueral network and PID control is used as a feedback controller. To show the feasibility of the proposed controller and hysteresis modeling, some experiments have been carried out. It is concluded that the proposed control scheme gives good tracking performance

  • PDF

Controller Auto-tuning Scheme for Improving Feedback System Performance in Frequency Domain (주파수역에서의 피드백시스템의 성능향상을 위한 제어기 Atuo-tuning 기법)

  • 정유철;이건복
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.3
    • /
    • pp.26-30
    • /
    • 2001
  • Controller refinement scheme to improve the performance of a conventional system automatically in frequency domain is proposed. The controller automatic tuning method features using experimental frequency responses of the conventional closed-loop system, the conventional controller, and the improved closed-loop system, instead of poorly modeled plant due to non-linearities and disturbances. The improved closed-loop system characteristics is automatically acquired by the con-ventional closed-loop system characteristics and the proposed performance index in system bandwidth. And the proper controller is realized by least squares approximation in frequency domain. To testify the usefulness of the approach, the path tracking control of robot arm is performed. Experimental results and analytic results are well-matched.

  • PDF

Design of Dead Time Compensator with Robustness (강인한 특서을 갖는 지연시간 보상기의 설계)

  • 박귀태;이기상;김성호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.2
    • /
    • pp.199-208
    • /
    • 1992
  • MIESF(Modified Integral Error and State Feedback) controller suggested in order to control the processes with time delay is the control scheme that combines Smith predictor and IESF(Integral Error and State Feedback). This control scheme has better performance than the conventional PID controller incorporating Smith predictor with respect to the robustness and control performance for the modelling error. MIESF controller can be simply designed by pole assignment algorithm. BUT in such a case, it is difficult to find proper poles which gurantee robustness with respect to process parameter uncertainties. In order to solve the aforementioned difficulties, we suggest a new design method for MIESF controller and show the validity of the proposed design method.

A study on power system stabilizer using output feedback adaptive variable structure control

  • Shin, Jin-Ho;Jeong, Il-Kwon;Choi, Changkyu;Lee, Ju-Jang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.177-182
    • /
    • 1994
  • In this paper, an output feedback adaptive variable structure control scheme is presented for stabilization of large scale power systems. An additional input signal which is called a power system stabilizer(PSS) is needed to improve the stability of a power system and to maintain the synchronization of generators. The proposed PSS scheme does not require a priori knowledge of uncertainty bounds. It is guaranteed that the closed-loop system is globally uniformly ultimately bounded by the Lyapunov stability theory. Simulation results for a multimachine power system are given to show the feasibility of the proposed scheme and the superiority of the proposed PSS in comparison with the conventional lead-lag PSS of PID-type.

  • PDF