• Title/Summary/Keyword: PID Feedback

Search Result 274, Processing Time 0.029 seconds

A Design of Speed Control Systems for the Governor in Power Station using QFT and Genetic Algorithm (QFT와 유전 알고리즘을 이용한 발전소 조속기 속도제어계의 설계)

  • 김주식;유정웅
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.77-84
    • /
    • 1998
  • Speed control systems of the governor in power station used in this study is organized by the regulator (PID controller), actuator and turbine. Considering parameter uncertainties and disturbances in this system, the performance may not be achieved by the PID control. Therefore, a design technique is necessary that accomplish the desired system performance tolerance in despite of plant uncertainty i\I1d disturbances. In this study, we used QFT(Quantitative Feedback Theory) to provide stable operation in power plant and presented the genetic algorithm for loop shaping approximation technique of QFT. And we designed speed control systems for the governor using the above approach.proach.

  • PDF

Fuzzy Modeling and Control of Wheeled Mobile Robot

  • Kang, Jin-Shik
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.587-590
    • /
    • 2003
  • In this paper, the control of the differential drive wheeled mobile robot (DDWMR) is studied. Because the DDWMR have non-holonomic constraints, it cannot be stabilized by smooth feedback. The T-S fuzzy model for the DDWMR is presented and a control algorithm Is developed by well known PID control and LMI based regional pole-placement.

  • PDF

Tip Position Command Tracking of a Flexible Beam Using Active Vibration Control (능동진동제어를 이용한 유연보의 끝단위치 명령추종연구)

  • Lee, Young-Sup;Elliott, Stephen-J
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.643-648
    • /
    • 2003
  • The problem considered in this paper is that the tip position of a flexible cantilever beam is controlled to follow a command signal, using a pair of piezoelectric actuators at the clamped end. The beam is lightly damped and so the natural transient response is rather long, and also since the sensor and actuator are not collocated, the plant response is non-minimum phase. Two control strategies were investigated. The first involved conventional PID control in which the feedback gains were adjusted to give the fastest closed-loop response to a step input. The second control strategy was based on an internal model control (IMC) architecture. The control filter in the IMC controller was a digital FIR device designed to minimize the expectation of the mean square tracking error. The IMC controller designed fur the beam was found to have very much reduced settling times to a step input compared with those of the PID controller.

  • PDF

Active control of the Self-excited Vibration of a Rotor System Supported by Tilting-Pad Gas Bearing (틸딩 패드 기체 베어링으로 지지된 로터 계 자려 진동의 능동제어)

  • Kwon, Tae-Gyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.119-125
    • /
    • 2001
  • This paper presents an experimental study on active control of self-excited vibration for a high speed turbomachinery. In order to suppress the self-excited vibration, it is necessary to actively control the air film pressure or the air film thickness. In this study, active pads are used to control the air film thickness. Active pads are supported by pivots containing piezoelectric actuators and their radial position can be actively controlled by applying voltage to the actuators. The transfer characteristics from actuator inputs to shaft vibration outputs are experimentally investigated. In a tilting-pad gas bearing (TPGB), a shaft is supported by the pressurized air film. Four gap sensors were used to measure the vibration of the shaft and PID was used in the feedback control of the shaft vibration. The experimental results show that the self-excited vibration of the rotor can be effectively suppressed if the PID controller gains are properly chosen. As a result we find that the feedback control is effective for suppressing the self-excited vibration of a rotor system using stack-type PZT actuators.

  • PDF

Control of Outmost Poloidal Flux Surface of Tokamak Plasma in RTP (RTP에서 토카막 플라즈마의 폴로이달 등자속면 제어)

  • Lee, Kwang-Won;Oh, Byung-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.136-147
    • /
    • 1993
  • The paper describes : ⅰ) Mathematical modeling of poloidal flux to define and calculate the tokamak plasma position based on a property of the plasma boundary which is always a flux surface. Controlling the plasma boundary position is therefore equivalent to equalizing the flux value on several points belonging to a curve tangent to the limiter. ⅱ) Experimental method for determining the outmost poloidal isoflux surface by a linear combination of measurements of magnetic fluxes, fields and field gradients, without requiring knowledge of internal plasma parameters for the feedback control, i.e., with neither corrections for variation in the poloidal beta and the plasma current distribution, nor compensations for the induced currents in the vacuum vessel. ⅲ) Feedback control algorithm for the regulation of plasma boundary position and its electronics hardware based on the PID control theory. ⅳ) Experimental results obtained from the RTP tokamak experiments using the present plasma control system.

  • PDF

A Study on Compliance Robot Using a PID Adaptive Controller (PID 적응 제어기를 이용한 컴플라이언스 로보트에 대한 연구)

  • Kim, Seung-Woo;Kang, Moon-Sik;Koh, Jae-Won;Park, Mign-Yong;Lee, Sang-Bae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.2
    • /
    • pp.105-110
    • /
    • 1990
  • In this paper, a compliance robot control algorithm using a PID adaptive controller is proposed. The compliance robot is suitable for the tasks in contact with environment, such as assembly operation or surface processing. A hybrid robot control method can control force and position simultaneously and two independant feedback closed loops are formed in this method. Because the compliance robot is operated in contact with environment, it is very difficult to obtain linear model of dynamics for this robot. In order to overcome this difficulty, a PID adaptive controller independant of robot dynamics is applied to the compliance robot. The proposed control algorithm for the compliance robot was analyzed and conformed by simulating the surface processing task by a two-joint robot.

  • PDF

Control of dissolved Oxygen Concentration and Specific Growth Rate in Fed-batch Fermentation (유가식 생물반응기에서의 용존산소농도 및 비성장속도의 제어)

  • Kim, Chang-Gyeom;Lee, Tae-Ho;Lee, Seung-Cheol;Chang, Yong-Keun;Chang, Ho-Nam
    • Microbiology and Biotechnology Letters
    • /
    • v.21 no.4
    • /
    • pp.354-365
    • /
    • 1993
  • A novel control method with automatic tuning of PID controller parameters has been developed for efficient regulation of dissolved oxygen concentration in fed-batch fermentations of Escherichia coli. Agitation speed and oxygen partial pressure in the inlet gas stream were chosen to be the manipulated variables. A heuristic reasoning allowed improved tuning decisions from the supervision of control performance indices and it coule obviate the needs for process assumptions or disturbance patterns. The control input consisted of feedback and feedforword parts. The feedback part was determined by PID control and the feedforward part is determined from the feed rate. The proportional gain was updated on-line by a set of heuristics rules based on the supervision of three performance indices. These indices were output error covariance, the average value of output error, and input covariance, which were calculated on-line using a moving window. The integral and derivative time constants were determined from the period of output response. The specific growth rate was maintained at a low level to avoid acetic acid accumulation and thus to achieve a high cell density. The specific growthe rate was estimated from the carbon dioxide evolution rate. In fed-batch fermentation, the simutaneous control of dissolved oxygen concentration (at 0.2; fraction of saturated value) and specific growth rate (at 0.25$hr^{-1}$) was satisfactory for the entire culture period in spite of the changes in the feed rate and the switching of control input.

  • PDF

DOB-based piezoelectric vibration control for stiffened plate considering accelerometer measurement noise

  • Li, Shengquan;Zhao, Rong;Li, Juan;Mo, Yueping;Sun, Zhenyu
    • Smart Structures and Systems
    • /
    • v.14 no.3
    • /
    • pp.327-345
    • /
    • 2014
  • This paper presents a composite control strategy for the active suppression of vibration due to the unknown disturbances, such as external excitation, harmonic effects and control spillover, as well as high-frequency accelerometer measurement noise in the all-clamped stiffened plate. The proposed composite control action based on the modal approach, consists of two contributions including feedback part and feedforward part. The feedback part is the well-known PID controller, which is widely used to increase the structure damping and improve its dynamic performance close to the resonance frequencies. In order to get better performance for vibration suppression, the weight matrixes is optimized by chaos sequence. Then an improved disturbance observer (IDOB) as the feedforward compensation part is developed to enhance the vibration suppression performance of PID under various disturbances and uncertainties. The proposed IDOB can simultaneously estimate the various disturbances dynamically as well as measurement noise acting on the system and suppress them by feedforward compensation design. A rigorous analysis is also given to show why the IDOB can effectively suppress the unknown disturbances and measurement noise. In order to verify the proposed composite control algorithm (IDOB-PID), the dSPACE real-time simulation platform is used and an experimental platform for the all-clamped stiffened plate active vibration control system is set up. The experimental results demonstrate the effectiveness, practicality and strong anti-disturbances ability of the proposed control strategy.

A study on the Performance Improvement of Position Controller in DC Servo Motor System (직류서보전동기 위치제어기의 성능향상에 관한 연구)

  • Yoo, Jong-Gul;Lee, Kee-Sang;Hong, Soon-Chan
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.555-558
    • /
    • 1991
  • The IESF(Integral Error and State Feedback) controller, which incorporates state feedback as a modern control scheme and integral action as a classical control scheme, has better performance than that of the conventional PID controller in linear time-invariant systems. The IESF controller requires the measurement of all the state variables. But, unfortunately, it may be difficult or impossible to measure all state variables in many applications. And the IESF controller is applicable only to pole-assignable linear time-invariant system without time delay. In this paper, new IESF controller structure was proposed which performs feedback with only measurable state variables. In order to estimate the unmeasurable state variables. It was adopted the filter mode by full-order obserber. The good performance and effectiveness of the proposed controller was confirmed by computer simulation.

  • PDF

Control of Electromagnetic Levitation System using ε-scaling Partial State Feedback Controller (ε조절 요소를 가진 부분 상태 궤환 제어기를 이용한 자기부상 시스템의 제어)

  • Park, Gyu-Man;Choi, Ho-Lim
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1572-1576
    • /
    • 2011
  • The electromagnetic levitation(EMS) system is one of the well-known nonlinear system because of its nonlinearity and several control techniques have been proposed. We propose an ${\epsilon}$-scaling partial feedback controller for the ball position control of the EMS system. The key feature of our proposed controller is the use of the scaling factor ${\epsilon}$ which provides a function of controller gain tuning along with robustness. In this paper, we show the stability analysis of our proposed controller and the convergence analysis of the state observer in terms of ${\epsilon}$-scaling factor. In addition, the experimental results show the validity of the proposed controller and improved control performance over the conventional PID controller.