• Title/Summary/Keyword: PICS

Search Result 41, Processing Time 0.024 seconds

Absolute Radiometric Calibration for KOMPSAT-3 AEISS and Cross Calibration Using Landsat-8 OLI

  • Ahn, Hoyong;Shin, Dongyoon;Lee, Sungu;Choi, Chuluong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.4
    • /
    • pp.291-302
    • /
    • 2017
  • Radiometric calibration is a prerequisite to quantitative remote sensing, and its accuracy has a direct impact on the reliability and accuracy of the quantitative application of remotely sensed data. This paper presents absolute radiometric calibration of the KOMPSAT-3 (KOrea Multi Purpose SATellite-3) and cross calibration using the Landsat-8 OLI (Operational Land Imager). Absolute radiometric calibration was performed using a reflectance-based method. Correlations between TOA (Top Of Atmosphere) radiances and the spectral band responses of the KOMPSAT-3 sensors in Goheung, South Korea, were significant for multispectral bands. A cross calibration method based on the Landsat-8 OLI was also used to assess the two sensors using near simultaneous image pairs over the Libya-4 PICS (Pseudo Invariant Calibration Sites). The spectral profile of the target was obtained from EO-1 (Earth Observing-1) Hyperion data over the Libya-4 PICS to derive the SBAF (Spectral Band Adjustment Factor). The results revealed that the TOA radiance of the KOMPSAT-3 agree with Landsat-8 within 5.14% for all bands after applying the SBAF. The radiometric coefficient presented here appears to be a good standard for maintaining the optical quality of the KOMPSAT-3.

Instruments to Assess Physical Impairments in Post-Intensive Care Syndrome: A Systematic Review (집중치료 후 증후군의 신체적 장애 측정도구에 관한 체계적 고찰)

  • Kang, Jiyeon;Lee, Minju;Jeong, Yeon Jin;Kim, Soo Kyung;Cho, Young Shin;Park, Jung Hoon;Lee, Soon;Hong, Ji Won
    • Journal of Korean Critical Care Nursing
    • /
    • v.11 no.1
    • /
    • pp.46-66
    • /
    • 2018
  • Purpose : The purpose of this study was to systematically review the instruments utilized to assess physical impairment in post-intensive care syndrome (PICS) of intensive care unit (ICU) survivors. Method : Online databases searched were MEDLINE, Cochrane, CINAHL, and Embase. Studies that met the following criteria were included: 1) the study population exclusively had experience with ICU admission; 2) the study assessed pulmonary, neuromuscular, and physical functions; and 3) the study was published in English language journals after 2007. Results : A total of 56 instruments (2 pulmonary, 25 neuromuscular, 29 physical function) from 94 studies were reviewed. They were classified into self-report, observation, and measurement according to the type of assessment. No instrument measured all 3 areas of physical impairment. Five instruments were originally developed for the ICU patients. The most frequently applied instruments were the Medical Research Council and the 36-item Short Form Survey (physical component summary), which were used in 23 studies each. Only 13.8% of reviewed studies reported the reliability or validity of the instruments. Conclusion : Our results suggest that the appropriateness of instruments assessing physical impairment in PICS cannot be guaranteed. Despite the multidimensional concept of physical disabilities, most studies measured only one area, and studies that reported psychometric properties were limited. Accordingly, we propose to develop a unique and multifaceted instrument for ICU survivors.

The Assessment of Cross Calibration/Validation Accuracy for KOMPSAT-3 Using Landsat 8 and 6S

  • Jin, Cheonggil;Choi, Chuluong
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.1
    • /
    • pp.123-137
    • /
    • 2021
  • In this study, we performed cross calibration of KOMPSAT-3 AEISS imaging sensor with reference to normalized pixels in the Landsat 8 OLI scenes of homogenous ROI recorded by both sensors between January 2014 and December 2019 at the Libya 4 PICS. Cross calibration is using images from a stable and well-calibrated satellite sensor as references to harmonize measurements from other sensors and/or characterize other sensors. But cross calibration has two problems; RSR and temporal difference. The RSR of KOMPSAT-3 and Landsat 8 are similar at the blue and green bands. But the red and NIR bands have a large difference. So we calculate SBAF of each sensor. We compared the SBAF estimated from the TOA Radiance simulation with KOMPSAT-3 and Landsat 8, the results displayed a difference of about 2.07~2.92% and 0.96~1.21% in the VIS and NIR bands. Before SBAF, Reflectance and Radiance difference was 0.42~23.23%. Case of difference temporal, we simulated by 6S and Landsat 8 for alignment the same acquisition time. The SBAF-corrected cross calibration coefficients using KOMPSAT-3, 6S and simulated Landsat 8 compared to the initial cross calibration without correction demonstrated a percentage difference in the spectral bands of about 0.866~1.192%. KOMPSAT-3 maximum uncertainty was estimated at 3.26~3.89%; errors due to atmospheric condition minimized to less than 1% (via 6S); Maximum deviation of KOMPSAT-3 DN was less than 1%. As the result, the results affirm that SBAF and 6s simulation enhanced cross-calibration accuracy.

A Study on the Effective Selective Filtering Technology of Harmful Website Using Internet Content Rating Service (인터넷 등급서비스를 이용한 효과적인 유해사이트 선별 기술에 관한 연구)

  • Lee, Jae-Sun;Jeon, Yong-Hee
    • Annual Conference of KIPS
    • /
    • 2002.11c
    • /
    • pp.2355-2358
    • /
    • 2002
  • 인터넷의 급격한 보급으로 음란외설 폭력정보와 같은 불건전 정보가 날로 증가하고 있으며 이러한 유해정보로 인해 청소년들에게 심각한 사회적인 문제를 초래하고 있다. 이에 따라, 본 논문에서는 기존의 보편화된 차단방식의 문제점을 해소하기 위해 등장한 인터넷 내용 등급제를 비교분석하고, 정보통신윤리위원회에서 제시한 등급기준을 토대로 PICS(Platform for Internet Content Selection) 기반의 선별 프로그램을 구현하고, 기존 차단 프로그램과 성능을 비교 평가하였다. 구현된 프로그램은 현재 실용화되는 기술과의 호환성을 유지하도록 시스템을 구성하였다.

  • PDF

A Design for the Automated Process of LCD Module Assembly Line (LCD 모듈 조립라인의 공정 자동화 설계)

  • Song, Chun-Sam;Kim, Joo-Hyun;Kim, Jong-Hyeong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.162-165
    • /
    • 2007
  • TFT-LCD process has two advantages as compared with the semiconductor-process. It is that cycle time is short and number of the final products are small. But it needs complicated inspection / assembly line to be treated manually and much higher labor costs in the TFT-LCD process. Also, It is necessary to build PICS(Production Information and Control System) which is automated and intelligent. In this paper, an automated process of LCD module assembly line that can increase productivity and reduce the cost of production to strengthen the competitiveness corresponding with global market is planned in comparison with its manual/semi-auto. It is noted that The automated line for COG$\sim$FOG process replacing with the existing facilities had the following effects; the productivity is increased to about 1.5 times and labor cost reduced 85%. In addition, whole assembly line can be short and simple.

Passive Optical Network system Using bi-direction SOA (양방향 반도체 광증폭기를 이용한 수동 광통신망 시스템)

  • Choe, Yeong-Bok;Park, Su-Jin
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2008.02a
    • /
    • pp.293-294
    • /
    • 2008
  • Using bi-direction SOA based Extension system, FTTH can enhance PON system by increasing both the upstream and downstream link budget. This increased link budget can be used to extend the distance, increase the split ratio or both. The bi-direction SOA regenerates signals using all-optical amplification, and is therefore transparent to data rate or protocol. The bi-direction SOA supports legacy as well as future FTTx standards. This is based on SOA's proprietary technology platform for the manufacturing of advanced discrete photonics and photonic integrated circuits (PICs). Because the bi-direction SOA uses the same InP semiconductor technology used in virtually all telecom lasers, it is able to amplify signals at 1310 and 1490 nm, wavelengths not accessible with commercial fiber-amplifier (EDFA) technology. Due to the extremely fast response time of the InP semiconductor optical amplifiers inside, the SOA can accommodate both continuous (downstream) and bursty (upstream) traffic.

  • PDF

Object segmentation and object-based surveillance video indexing

  • Kim, Jin-Woong;Kim, Mun-Churl;Lee, Kyu-Won;Kim, Jae-Gon;Ahn, Chie-Teuk
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.165.1-170
    • /
    • 1999
  • Object segmentation fro natural video scenes has recently become one of very active research to pics due to the object-based video coding standard MPEG-4. Object detection and isolation is also useful for object-based indexing and search of video content, which is a goal of the emerging new standard, MPEG-7. In this paper, an automatic segmentation method of moving objects in image sequence is presented which is applicable to multimedia content authoring for MPEG-4, and two different segmentation approaches suitable for surveillance applications are addressed in raw data domain and compressed bitstream domains. We also propose an object-based video description scheme based on object segmentation for video indexing purposes.

Radiometric Cross Validation of KOMPSAT-3 AEISS (다목적실용위성 3호 AEISS센서의 방사 특성 교차 검증)

  • Shin, Dong-yoon;Choi, Chul-uong;Lee, Sun-gu;Ahn, Ho-yong
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.5
    • /
    • pp.529-538
    • /
    • 2016
  • This study, multispectral and hyperspectral sensors were utilized to use radiometric cross validation for the purpose of radiometric quality evaluation of a 'KOMPSAT-3'. Images of EO-1 Hyperion and Landsat-8 OLI sensors taken in PICS site were used. 2 sections that have 2 different types of ground coverage respectively were selected as the site of cross validation based on aerial hyperspectral sensor and TOA Reflectance. As a result of comparison between the TOA reflectance figures of KOMPSAT-3, EO-1 Hyperion and CASI-1500, the difference was roughly 4%. It is considered that it satisfies the radiological quality standard when the difference of figure of reflectance in a comparison to the other satellites is found within 5%. The difference in Blue, Green, Red band was approximately 3% as a comparison result of TOA reflectance. However the figure was relatively low in NIR band in a comparison to Landsat-8. It is thought that the relatively low reflectance is because there is a difference of band passes in NIR band of 2 sensors and in a case of KOMPSAT-3 sensor, a section of 940nm, which shows the strong absorption through water vapor, is included in band pass resulting in comparatively low reflectance. To overcome these conditions, more detailed analysis with the application of rescale method as Spectral Bandwidth Adjustment Factor (SBAF) is required.

Radiometric Cross Calibration of KOMPSAT-3 and Lnadsat-8 for Time-Series Harmonization (KOMPSAT-3와 Landsat-8의 시계열 융합활용을 위한 교차검보정)

  • Ahn, Ho-yong;Na, Sang-il;Park, Chan-won;Hong, Suk-young;So, Kyu-ho;Lee, Kyung-do
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_2
    • /
    • pp.1523-1535
    • /
    • 2020
  • In order to produce crop information using remote sensing, we use classification and growth monitoring based on crop phenology. Therefore, time-series satellite images with a short period are required. However, there are limitations to acquiring time-series satellite data, so it is necessary to use fusion with other earth observation satellites. Before fusion of various satellite image data, it is necessary to overcome the inherent difference in radiometric characteristics of satellites. This study performed Korea Multi-Purpose Satellite-3 (KOMPSAT-3) cross calibration with Landsat-8 as the first step for fusion. Top of Atmosphere (TOA) Reflectance was compared by applying Spectral Band Adjustment Factor (SBAF) to each satellite using hyperspectral sensor band aggregation. As a result of cross calibration, KOMPSAT-3 and Landsat-8 satellites showed a difference in reflectance of less than 4% in Blue, Green, and Red bands, and 6% in NIR bands. KOMPSAT-3, without on-board calibrator, idicate lower radiometric stability compared to ladnsat-8. In the future, efforts are needed to produce normalized reflectance data through BRDF (Bidirectional reflectance distribution function) correction and SBAF application for spectral characteristics of agricultural land.

Atomic Layer Deposition Method for Polymeric Optical Waveguide Fabrication (원자층 증착 방법을 이용한 폴리머 광도파로 제작)

  • Eun-Su Lee;Kwon-Wook Chun;Jinung Jin;Ye-Jun Jung;Min-Cheol Oh
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.4
    • /
    • pp.175-183
    • /
    • 2024
  • Research into optical signal processing using photonic integrated circuits (PICs) has been actively pursued in various fields, including optical communication, optical sensors, and quantum optics. Among the materials used in PIC fabrication, polymers have attracted significant interest due to their unique characteristics. To fabricate polymer-based PICs, establishing an accurate manufacturing process for the cross-sectional structure of an optical waveguide is crucial. For stable device performance and high yield in mass production, a process with high reproducibility and a wide tolerance for variation is necessary. This study proposes an efficient method for fabricating polymer optical-waveguide devices by introducing the atomic layer deposition (ALD) process. Compared to conventional photoresist or metal-film deposition methods, the ALD process enables more precise fabrication of the optical waveguide's core structure. Polyimide optical waveguides with a core size of 1.8 × 1.6 ㎛2 are fabricated using the ALD process, and their propagation losses are measured. Additionally, a multimode interference (MMI) optical-waveguide power-splitter device is fabricated and characterized. Throughout the fabrication, no cracking issues are observed in the etching-mask layer, the vertical profiles of the waveguide patterns are excellent, and the propagation loss is below 1.5 dB/cm. These results confirm that the ALD process is a suitable method for the mass production of high-quality polymer photonic devices.