• Title/Summary/Keyword: PI Index

Search Result 405, Processing Time 0.029 seconds

DMFT Index, Periodontal Index and Oral Hygiene Status in Diabetic Patients (당뇨병 환자에서 우식경험영구치지수, 치주질환지수 및 구강위생 상태)

  • Lee, Kyung-Dong;Lee, Hee-Kyung
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.1
    • /
    • pp.62-71
    • /
    • 2005
  • Background: This study examined the oral health condition of diabetic patients and evaluated the oral health behavior through a questionnaires survey. In addition, this study provide primary informations for developing a dental health program for diabetic patients. Materials and Methods: There were fifty patients with diabetes mellitus or glucose tolerance (controlled by a community health center at Dalsung-Gun in Daegu City and fifty nondiabetic age, gender and location matched control subjects. Data were collected by a direct oral examination and by questionnaires from 100 subjects in July, 2004. Results: The DMFT (Decay, Missing, Filling Teeth) mean values in diabetics were significantly higher than that in non-diabetics (p<0.05). The decay teeth index and Filling teeth index was similar in the two groups, but the mean Missing teeth index was significantly higher in the diabetics than in non-diabetics. The PI (Periodontal Index) mean values were significantly higher in the diabetics than in the non-diabetics (p<0.01). There was a significant difference between the diabetics and non diabetics aged in their 50s and 60s, but there was no difference with those aged in their 70s. The oral hygiene status was similar in the two groups. The average number of remaining teeth was significantly lower in the diabetics ($16.1{\pm}10.35$) than in the non-diabetics ($20.04{\pm}8.70$) (p<0.05). Conclusion: In the diabetic patients, the M component of the DMFT index was found to be higher than the controls. Diabetics lose their teeth mainly due to periodontal disease, which is supported by the increased PI mean values.

  • PDF

3-Dimensional Performance Optimization Model of Snatch Weightlifting

  • Moon, Young-Jin;Darren, Stefanyshyn
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.2
    • /
    • pp.157-165
    • /
    • 2015
  • Object : The goals of this research were to make Performance Enhanced Model(PE) taken the largest performance index (PI) through artificial variation of principle components calculated by principle component analysis for trial data, and to verify the effect through comparing kinematic factors between trial data (Raw) and PE. Method : Ten subjects (5 men, 5 women) were recruited and 80% of their maximal record was considered. The PI is a regression equation. In order to develop PE, we extracted Principle components from trial position data (by Principle Components Analysis (PCA)). Before PCA, we made 17 position data to 3 row matrix according to components. We calculated 3 eigen value (principle components) through PCA. And except Y (medial-lateral direction) component (because motion of Y component is small), principle components of X (anterior-posterior direction) and Z (vertical direction) components were changed as following. Changed principle components = principle components + principle components ${\times}$ k. After changing the each principle component, we reconstructed position data using the changed principle components and calculated performance index (PI). A Paired t-test was used to compare Raw data and Performance Enhanced Model data. The level of statistical significance was set at $p{\leq}0.05$. Result : The PI was significantly increased about 12.9kg at PE ($101.92{\pm}6.25$) when compared to the Raw data ($91.29{\pm}7.10$). It means that performance can be increased by optimizing 3D positions. The difference of kinematic factors as follows : the movement distance of the bar from start to lock out was significantly larger (about 1cm) for PE, the width of anterior-posterior bar position in full phase was significantly wider (about 1.3cm) for PE and the horizontal displacement toward the weightlifter after beginning of descent from maximal height was significantly greater (about 0.4cm) for PE. Additionally, the minimum knee angle in the 2-pull phase was significantly smaller (approximately 2.7cm) for the PE compared to that of the Raw. PE was decided at proximal position from the Raw (origin point (0,0)) of PC variation). Conclusion : PI was decided at proximal position from the Raw (origin point (0,0)) of PC variation). This means that Performance Enhanced Model was decided by similar motion to the Raw without a great change. Therefore, weightlifters could be accept Performance Enhanced Model easily, comfortably and without large stress. The Performance Enhance Model can provide training direction for athletes to improve their weightlifting records.

Use of the Color Doppler Ultrasonography for the Evaluation of the Hemodynamic Changes of the Cranial Pancreaticoduodenal Arterial Flow in Experimentally Induced Acute Pancreatitis Dogs (실험적으로 유발된 급성 췌장염 견에서 컬러도플러 초음파를 이용한 전방 십이지장 동맥 혈류의 혈역학적 변화에 대한 평가)

  • Lee, Hae-Woon;Um, Ki-Dong;Sung, Yoon-Sang;Lee, Jung-Min;Lee, Jong-Won;Lee, Geun-Woo;Kim, Myung-Chul;Kim, Doo;Park, Sun-Il
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.334-340
    • /
    • 2003
  • For the study of the hemodynamic changes of the cranial pancreaticoduodenal arterial flow(cPDAF) in the dog with acute pancreatitis, acute pancreatitis was experimentally induced in 10 dogs by the injection of oleic acid into the accessory pancreatic duct. The parameters of cPDAF were measured by transcutaneous pulsed-wave Doppler ultrasonography. The hemodynamic changes included resistive indexe(RI), pulsatility index(PI) and maximum velocity (Vmax). Ultrasonographic scans were performed before the induction of pancreatitis and once daily for five days after the induction. The RI, PI and Vmax were increased with day as follows; the RI prior to induction was 0.625$\pm$0.096 (mean$\pm$SD), the PI was 1.117$\pm$0.289 and the Vmax was 0.349$\pm$0.094 m/s. After five days, the RI was 0.727$\pm$0.051 (p<0.0l), the PI was 1.480$\pm$0.284 (p<0.0l) and the Vmax was 0.585:$\pm$0.114 m/s (p<0.00l). These results show that there is some relation between the increase of the RI, PI and Vmax of cPDAF and the progress of acute pancreatitis in dogs. Therefore, the measurements of the hemodynamic changes of cPDAF may be a valuable technique for the evaluation of acute pancreatitis in dogs.

The effect of Light Emitting Diode electric toothbrush on gingivitis: a randomized controlled trial (발광 다이오드(Light Emitting Diode) 전동칫솔의 치은염에 대한 효과: 무작위 배정 임상시험)

  • Lee, Sung-Jo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.119-126
    • /
    • 2017
  • Purpose: The aim of the present study was to compare clinical antiplaque and antigingivitis effect between Light Emitting Diode (LED) electronic toothbrush and electronic toothbrush without LED for gingivitis and mild periodontitis patients. Materials and Methods: 30 patients included in this study. 15 patients in experimental group used LED electronic tooth brush which has red and white LED within its head, and other 15 patients in control group used same product which specially modified that function without LED. Clinical parameters ($L{\ddot{o}}e-Silness$ gingival index (GI), Quigley-Hein plaque index (PI)) were measured at the baseline, 2 weeks and 4 weeks later. Wilcoxon signed rank test and Mann-Whitney test were used for statistical analysis. Results: Compare of GI change between experimental and control group with time, both groups showed that reduced GI, but lower GI values detected at 2 weeks and 4 weeks later in experimental group than control group. And lower PI values detected at 4 weeks later in experimental group than control group, but not statistically significant. Conclusion: Based on these results and within the limits of this study, the electronic toothbrush with LED could reducing gingivitis in a short period and infer that decreasing plaque accumulation in a long period.

Photochemical Index Analysis on Different Shading Level of Garden Plants (정원 식물의 차광 조건별 광화학적 생리지표 해석)

  • Kang, Hong Gyu;Kim, Tae Seong;Park, So Hyun;Kim, Tae Wan;Yoo, Sung Yung
    • Korean Journal of Environmental Biology
    • /
    • v.34 no.4
    • /
    • pp.264-271
    • /
    • 2016
  • The objective of this study was to determine the growth and light utilization efficiency of garden plants in shade area through chlorophyll fluorescence reaction analysis. Ten garden plants was grown for 75 days under 50% and 80% shading conditions. Under shading, $ET2_O/RC$, the fluorescence parameter related to electron-transport in photosystem II, was effectively enhanced. However, the electron transport flux until PSI acceptors per reaction center ($RE1_O/RC$) was reduced. These changes in photochemical parameters evoked a decrease in performance index (PI) and driving force (DF) of electron transport flux. In addition, some photochemical parameters such as $F_V$, $FV/F_O$, $RE1_O/RC$, $ET2_O/RC$, $PI_{TOTAL\;ABS}$, and $DF_{TOTAL\;ABS}$ were found to be important for shade tolerance. Three species (Pachysandra terminalis Siebold & Zucc, Physostegia virginiana L., and Carex maculata Bott) were found to be shade tolerant. Based on these results, shading factor index (SFI) deduced from photochemical parameters is useful for evaluating of shading stress of garden plants.

A Study of the Retention Mechanism of the Monosubstituted Benzenes in Reversed-phase Liquid Chromatography (II) (역상 액체크로마토그래피에서 벤젠 일치환체들의 머무름 메카니즘에 관한 연구 (제 2 보))

  • Lee, Dai-Woon;Choi, Yong-Wook;Lee, Won
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.135-143
    • /
    • 1988
  • The correlations between chromatographic parameters of monosubstituted benzenes and several physical parameters in reversed phase liquid chromatography were studied. The relationships between retention data and polarity index were investigated by plotting $log(log k'_S/k'_B)$ vs. $P'_S/P'_B$ which were relative retention and relative polarity index of monosubstituted benzenes with respect to benzene, respectively. The linear relationship between relative retention and polarity index was observed for the monosubstituted benzenes having polar group, while in case of those having nonpolar group, the good linearity was observed by combination with relative molecular weight i.e. $(P'_S/P'_B)/(MW_S/MW_B)$. Multivariant regression analysis, $a(P'_S/P'_B)+b(MW_S/MW_B)$+c did not give significantly better correlations compared to single variant analysis, $a[(P'_S/P'_B)/(MW_S/MW_B)]$+c, but multiple stepwise regression analysis was recommended when several physical parameters simultaneously were chosen. The best correlation between retention data for monosubstituted benzenes taken from the literature and substituent constant(${\pi}$), derived from hydrophobic parameter and the first order molecular connectivity index$(^1{\chi}^{\nu})$, was established for methanol/water mobile phase system. The larger the surface coverage of the stationary phase, the higher was the correlation coefficient between these two parameters and retention data.

  • PDF

Effects of Acupuncture therapy on Cerebral Blood flow in Migraineurs (편두통 환자의 뇌혈류에 대한 침치료의 효과)

  • Kim Dong-Won;Ahn Kyo-Pil;Eom Hoy-Jin;Nam Young;Lee Si-Sup
    • Journal of Acupuncture Research
    • /
    • v.18 no.6
    • /
    • pp.135-140
    • /
    • 2001
  • Objective : To investigate the effects of Acupuncture therapy on the migraineur by way of the change of the Cerebral blood flow. Methods : 6 migraineurs were inserted in acupoints on GV16, G20, S8 during 2 weeks. and, Mean Velocity (MV) and Pulsatility Index (PI) of MCA, PCA, ACA, BA were measured before and after treatments of 2 weeks, respectively. Results : MV of MCA of the migraineurs was decreased very much by 13.3%, and PI was decreased much by 10.4%. However, MV and PI of BA changed little. Conclusion : It is observed that Acupuncture therapy reduces pains of migraineur through decreasing Cerebral blood flow like MCA.

  • PDF

Review of the Priority Index for Selection between Repair and Reinforcement Methods of Dam Facilities (댐 시설물 보수·보강공법 선정을 위한 우선순위지수에 대한 고찰 )

  • Dong Hyun Kim;Hyung Jun Park;Hee Jung Youn;Seung Oh Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.3
    • /
    • pp.1-11
    • /
    • 2023
  • After the collapse of the Seongsu Bridge in the 1990s in Korea, attention was focused on the maintenance of facilities. The government has established various policies since the enactment of the Act in 1995 until recently. In general, safety inspections are performed to evaluate the safety grade of facilities, and facilities are maintained and managed by performing repairs and reinforcements for defects. However, since the budget is limited, it is impossible to carry out repair and reinforcement projects for all defects. It is necessary to prioritize repair and reinforcement measures. Then, the priority index (PI) is presented considering the importance of members, the seriousness of defects, and economic feasibility. In this index, the degree of influence can be adjusted within the range of 50 to 100% according to the expert's subjective judgment, and the same weight is set for some specific members. Also, the effect through repair and reinforcement is not taken into account decisively, and most of them have a limit in which priority is determined by economic feasibility. Therefore, in this study, through several case studies, problems with the priority index were reviewed and an equation was presented to improve them.

Development of Borough Road Pavement Condition Evaluation Criteria and Prediction Index (자치구 포장상태평가등급 기준 개선 및 포장상태 예측지수 개발)

  • Lee, Sang Yum;Jeon, Jin Ho
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.115-122
    • /
    • 2016
  • OBJECTIVES : This study develops an evaluation method, which is useful to inspect pavement condition of specific boroughs. This is because pavement condition is broadly divided into five grades via visual inspection, which does not consider the types of deteriorations, and is decided by an investigator having a subjective viewpoint. This visual inspection method is not a satisfactory method for accurate maintenance when various deteriorations occur. METHODS : The performance model considers several factors such as crack, rutting, and IRI. This method is also modified from borough SPI based on SPI (Seoul Pavement Index). Considering limited budget of borough, PI (prediction index) is suggested, which is related to the grade of pavement condition evaluation and type of materials. Practical correlation review is also conducted with statistical verification by using the Monte Carlo simulation. RESULTS : The results of the study show that modified criteria are reasonable. First, the comparison between the visual inspection result and the SPI result indicates that the R-square value is sufficiently high. Second, through the common section, each evaluation method could be compared, and the result shows considerable similarity, which increases when the range is modified. Finally, PI for predicting remaining life and the random number SPI have common parts, which means that each indicator would be adequate to be used as an evaluation method. CONCLUSIONS : Comparison and analysis results show that the developed evaluation method is reasonable for specific boroughs where financial support is inadequate for the evaluation process by using the newer equipment. Moreover, for more accurate evaluation method, previous visual inspection data should be utilized, and the database of inspection equipment have to be collected.

Protective Ability Index of Rust Layer Formed on Weathering Steel Bridge

  • Hara, S.;Kamimura, T.;Miyuki, H.;Yamashita, M.;Uchida, H.
    • Corrosion Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.128-132
    • /
    • 2007
  • For a quantitative inspection on the performance of weathering steel bridges, we have investigated the relationship between the corrosion rate and the composition of the rust layers formed on weathering steel bridges located in various environments in Japan and applied a protective ability index (PAI) to the bridges. The corrosion rates were clearly classified by the PAI, ${\alpha}/{\gamma}*$ and sub index of $({\beta}+s)/{\gamma}*$, where $\alpha$, \gamma*, $\beta$ and s are the mass ratio of crystalline $\alpha-FeOOH$, the total of $\gamma$-FeOOH+ $\beta$-FeOOH + the spinel-type iron oxide (mainly $Fe_3O_4$), $\beta-FeOOH$ and spinel-type iron oxide, analyzed by powder X-ray diffraction, respectively. In the case of ${\alpha}/{\gamma}$*>1, the rust layer works protective enough to reduce the corrosion rate less than 0.01 mm/y. The sub index $({\beta}+s)/{\gamma}*$<0.5 or >0.5 classifies the corrosion rate of the non-protective rust layers, therefore the former state of the rust layer terms inactive and the latter terms active. The quantitative inspection of a weathering steel bridge requires a performance-inspection (PI) and periodical deteriorationinspections (DI). The PI can be completed by checking of the PAI, ${\alpha}/{\gamma}*$. The DI on the weathering steel bridges where deicing salt is sprinkled can be performed by checking the PAI, $({\beta}+s)/{\gamma}*$.