• Title/Summary/Keyword: PFM

Search Result 252, Processing Time 0.022 seconds

A study for piezoelectric properties analysis of the AlN thin film by using PFM (PFM을 이용한 AlN 박막의 압전특성 분석에 관한 연구)

  • Lee, Jong-Taek;Kim, Se-Young;Shin, Hyeon-Chang;Song, Jun-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.224-225
    • /
    • 2009
  • Aluminium nitride thin film was deposited on Au electrode and Si substrate by radio frequency sputtering system. X-ray diffraction (XRD) was utilized to identify the AlN phase, and Atomic Force Microscope (AFM) was used to obtain the images of surface morphology and roughness value of AlN thin film. The result of XRD and AFM measurement showed that the AlN thin film has strong c-axs orientation and smooth surface. In order to investigate piezoelectric response and polarization properties along to the direction of electric field, PFM (Piezoresponse Force Microscope) system was used, and the images of piezoelectric response due to switching of polarization was observed by PFM.

  • PDF

Simualation of PFM control signal for optical fiber transmission

  • Komatsu, Takeshi;Ikeda, Hiroaki;Li, Jinzhu;Aoki, Kazuya;Yoshida, Hirofumi;Shinohara, Shigenobu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1116-1118
    • /
    • 1990
  • This paper describes the required frequency bandwidth which is used as a measure for the quality of the PFM transmission system to transmit the control signals. First, the PFM signal which has been distorted due to the frequency bandwidth limit on the transmission line is analyzed by Fourier transform and secondly distortion which has been observed at the receiver is numerically analyzed to make the frequency bandwidth required for transmitting the PFM signals. According to the analysis heretofore, the 50% threshold level for shaping the received PFM signal, which is of 50 % in TTL level, is superior than the 10- and 90-% threshold levels.

  • PDF

PWM/PFM Dual Mode SMPS Controller IC for Active Forward Clamp and LLC Resonant Converters

  • Cheon, Jeong-In;Ha, Chang-Woo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.2
    • /
    • pp.94-97
    • /
    • 2007
  • The desin and implementation of a CMOS analog integrated circuit that provides dual-mode modulations, PWM for active clamp reset converter and PFM for LLC resonant converter, is described. The proposed controller is capable of implementing programmable soft start and current-mode control with compensating ramp for PWM and frequency shifting soft start for PFM. Also it provides delay time for both modes. PWM mode is implemented by active clamp reset converter and PFM mode is implemented by LLC resonant convereter, respectively. The chip is fabricated using the 0.6um high voltage CMOS process.

PFM APPLICATION FOR THE PWSCC INTEGRITY OF Ni-BASE ALLOY WELDS-DEVELOPMENT AND APPLICATION OF PINEP-PWSCC

  • Hong, Jong-Dae;Jang, Changheui;Kim, Tae Soon
    • Nuclear Engineering and Technology
    • /
    • v.44 no.8
    • /
    • pp.961-970
    • /
    • 2012
  • Often, probabilistic fracture mechanics (PFM) approaches have been adopted to quantify the failure probabilities of Ni-base alloy components, especially due to primary water stress corrosion cracking (PWSCC), in a primary piping system of pressurized water reactors. In this paper, the key features of an advanced PFM code, PINEP-PWSCC (Probabilistic INtegrity Evaluation for nuclear Piping-PWSCC) for such purpose, are described. In developing the code, we adopted most recent research results and advanced models in calculation modules such as PWSCC crack initiation and growth models, a performance-based probability of detection (POD) model for Ni-base alloy welds, and so on. To verify the code, the failure probabilities for various Alloy 182 welds locations were evaluated and compared with field experience and other PFM codes. Finally, the effects of pre-existing crack, weld repair, and POD models on failure probability were evaluated to demonstrate the applicability of PINEP-PWSCC.

Domain Wall Motions in a Near-Morphotropic PZT during a Stepwise Poling Observed by Piezoresponse Force Microscopy

  • Kim, Kwanlae
    • Korean Journal of Materials Research
    • /
    • v.27 no.9
    • /
    • pp.484-488
    • /
    • 2017
  • In the present study, domain evolution processes of a near-morphotropic PZT ceramic during poling was studied using vertical piezoresponse force microscopy (PFM). To perform macroscopic poling in bulk polycrystalline PZT, poling was carried out in a stepwise fashion, and PFM scan was performed after unloading the electric field. To identify the crystallographic orientation and planes for the observed non-$180^{\circ}$ domain walls in the PFM images, compatibility theory and electron backscatter diffraction (EBSD) were used in conjunction with PFM. Accurate registration between PFM and the EBSD image quality map was carried out by mapping several grains on the sample surface. A herringbone-like domain pattern consisting of two sets of lamellae was observed; this structure evolved into a single set of lamellae during the stepwise poling process. The mechanism underlying the observed domain evolution process was interpreted as showing that the growth of lamellae is determined by the potential energy associated with polarization and an externally applied electric field.

Comparison of accuracy between LC model and 4-PFM when COVID-19 impacts mortality structure

  • Choi, Janghoon
    • Communications for Statistical Applications and Methods
    • /
    • v.28 no.3
    • /
    • pp.233-250
    • /
    • 2021
  • This paper studies if the accuracies of mortality models (LC model vs. 4-parametric model) are aggravated if a mortality structure changes due to the impact of COVID-19. LC model (LCM) uses dimension reduction for fitting to the log mortality matrix so that the performance of the dimension reduction method may not be good when the matrix structure changes. On the other hand, 4-parametric factor model (4-PFM) is designed to use factors for fitting to log mortality data by age groups so that it would be less affected by the change of the mortality structure. In fact, the forecast accuracies of LCM are better than those of 4-PFM when life-tables are used whereas those of 4-PFM are better when the mortality structure changes. Thus this result shows that 4-PFM is more reliable in performance to the structural changes of the mortality. To support the accuracy changes of LCM the functional aspect is explained by computing eigenvalues produced by singular vector decomposition

Shade Matching Identification of in Vivo Natural Teeth and Porcelain-Fused-to-Metal Crowns (자연치와 도재관에 대한 색조선택의 동일성)

  • Cho, Hong-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.29 no.1
    • /
    • pp.35-48
    • /
    • 2007
  • The purpose of this study was to evaluate shade selection using conventional visual assessment in vivo natural teeth and porcelain-fused-to-metal (PFM) crown. Maxillary central incisors, lateral incisors and canines of one hundred twenty four college women were used as vivo natural teeth. Fifty one PFM crown for maxillary central incisor fabricated by dental laboratory were used as experimental materials. Using Vitapan Classical Shade Guides, shade selection of natural teeth was measured by each college woman and shade selection of PFM crown was measured by three ceramists with more than ten years career. Both natural teeth and PFM crown shade selection were measured through Shade Eye-Ex. From the shade selection comparing, following results were obtained. The results were as follows: 1. The shade matching identification of natural teeth between the shade selection using Vitapan Classical Shade Guides and the shade selection using Shade Eye-Ex was 27.4% in maxillary central incisor, 13.7% in lateral incisor and 18.5% in canine. 2. Among the shade selection of PFM crown by three ceramists, the shade evaluation of three ceramists were same only in ten cases. In twenty case, those of two ceramists were same. 3. The shade matching identification of PFM crown between the shade selection using Vitapan Classical Shade Guides and the shade selection using Shade Eye-Ex was 38.6% in average. These results suggest that the shade selection using conventional visual assessment should be dealt with care in clinic and need a credible method for shade matching color.

  • PDF

A Buck Converter with PLL-based PWM/PFM Integrated Control (PLL 기반 PWM/PFM 통합 제어 방식의 벅 컨버터)

  • Heo, Jung;Jeong, Hang-Geun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.8
    • /
    • pp.35-40
    • /
    • 2012
  • In DC-DC converters, a PWM/PFM dual mode control method is commonly used to maintain a high efficiency over a wide range of load variation. Since the control mode is selected according to the load condition, the chip area is increased due to additional circuit for mode control and the optimum efficiency cannot be achieved around the mode transition point. To solve such problems, a new integrated control method is proposed in this paper, in which a PLL is used in the current mode PWM control circuit instead of an oscillator. The proposed integrated control method is verified through a design of a buck converter using PSIM simulation. Simulation of the complete buck converter circuit by Cadence Spectre showed a maximum efficiency of 94.7% at a load current of 250mA and an efficiency of 85.4% at a load current of 10mA under the light load condition.

Effect of different contraction methods on pelvic floor muscle contraction in middle-aged women

  • Kim, Ji-Seon;Choi, Jong-Duk;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • v.4 no.2
    • /
    • pp.103-107
    • /
    • 2015
  • Objective: Pelvic floor muscles (PFMs) form the base of the abdomino-pelvic cavity and also the PFMs function is important for urinary continence. PFMs training (PFMT) is considered to be the first method for PFM dysfunction. This study demonstrated correct PFMs contraction among commonly used different contraction methods for PFMT. Design: Cross-sectional study. Methods: In this study, nineteen middle-aged (40-70 years) women participated. To evaluate PFM function, ultrasonography was used to measure the distance of the bladder base movement. The distance of the PFM movements were calculated at rest and during the other contractions. The following four different contraction methods were performed randomly: (1) PFM contraction, (2) abdominal drawing-in maneuver (ADIM), (3) anal contraction, and (4) hip adductor muscle contraction. The participants held the contraction for 3 seconds for a total of 3 times with a 30 seconds rest period between each trial. The mean of three measurements in each position were obtained and compared with that in the resting position. Results: The bladder base movement values were significantly greater when comparing PFM with ADIM and hip adductor contractions (p<0.05). The bladder base movement values were significantly greater when comparing ADIM and anal contractions with hip adductor contractions (p<0.05). Conclusions: The results of this study suggest that performing PFM contractions is the best method among the common methods for PFMT. Performing PFM contractions was more effective than the other contraction methods.

The effect of thermocycling on the bonding of different restorative materials to access opening through porcelain fused to metal restorations

  • Al-Moaleem, Mohammed M.;Shah, Farhan Khalid;Khan, Nausheen Saied;Porwal, Amit
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.4
    • /
    • pp.186-189
    • /
    • 2011
  • PURPOSE. Porcelain fused to metal (PFM) crowns provide the best treatment option for teeth that have a large or defective restoration. More than 20% of teeth with PFM crowns or bridges require non-surgical root canal treatment (NSRCT). This may be due to the effect of restorative procedures and the possible leakage of bacteria and or their by-products, which leads to the demise of the tooth pulp. Thus, this study was planned to compare the ability of the restorative materials to seal perforated PFM specimens. MATERIALS AND METHODS. The study evaluates the ability of amalgam, composite or compomer restorative materials to close perforated PFM specimen's in-vitro. Ninety PFM specimens were constructed using Ni-Cr alloys and feldspathic porcelain, and then they were divided into 3 groups: amalgam (A), composite + Exite adhesive bond (B) and compomer + Syntac adhesive bond (C). All the PFM samples were embedded in an acrylic block to provide complete sealing of the hole from the bottom side. After the aging period, each group was further divided into 3 equal subgroups according to the thermocycling period (one week for 70 cycles, one month for 300 cycles and three months for 900 cycles). Each subgroup was put into containers containing dye (Pelikan INK), one maintained at $5^{\circ}C$ and the other at $55^{\circ}C$, each cycle for 30 sec time. The data obtained was analyzed by SPSS, 2006 using one way ANOVA test and student t-test and significant difference level at (P<.01). RESULTS. The depth of dye penetration was measured at the interfaces of PFM and filling materials using Co-ordinate Vernier Microscope. The lowest levels of the dye penetration for the three groups, as well as subgroups were during the first week. The values of dye leakage had significantly increased by time intervals in subgroups A and C. CONCLUSION. It was seen that amalgam showed higher leakage than composite while compomer showed the lowest level of leakage.