• 제목/요약/키워드: PFC(Power Factor Correction

검색결과 315건 처리시간 0.029초

개선된 평균 전류 제어 방식 역률 개선 회로의 제어에 관한 연구 (A Study on the control of Power Factor Correction Circuit by Advanced Average Current Control)

  • 김태규;김태우;최현의;김민찬;안호균;윤태성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.999_1000
    • /
    • 2009
  • The purpose of this paper is a study on the control of Power Factor Correction circuit by advanced average current control. The international standard organizations have made an effort to resolve these problems caused by the harmonics and announced the international standards for limiting the harmonic currents of the electrical devices and products. For improving power factor and reducing harmonics, many studies are progressed rapidly. In this study, we explain a method of an advanced average current control. And then, the performances of the PFC circuit applying a advanced average current control method are simulated and verified by Matlab/Simulink.

  • PDF

수동 역률 보상회로를 이용한 LED 센서등 회로의 개발 (Development of LED sensor lights circuit by passive power factor correction circuit)

  • 박종연;유진완;이학범
    • 산업기술연구
    • /
    • 제32권A호
    • /
    • pp.109-114
    • /
    • 2012
  • In this paper, We studied LED(Light Emitted Diode) sensor lights system using PIR(Pyroelectric Infrared Ray) sensor, CdS and MCU(Micro Controller Unit). And applied the valley fill circuit to improve the power factor. We designed the amplifier for each sensor and the LED driver for constant current which is the buck converter. Also, we proposed the algorithm of LED control by each sensors using MCU. Experimental results showed that power factor is 92% with valley fill circuit.

  • PDF

펄스 주파수 변조 기법을 이용한 형광등 안정기의 파고율 저감 기법 (A Novel Method to Reduce Crest Factor of Electronic Ballast for Fluorescent Lamps Using Pulse Frequency Modulation)

  • 송주호;이동윤;송중호;최주엽;최익;임묘택
    • 전력전자학회논문지
    • /
    • 제5권3호
    • /
    • pp.291-299
    • /
    • 2000
  • 형광등의 수명은 형광등 안정기의 시동 시나리오와 형광등 전류의 파고율에 영향을 받는다. 본 논문에서는 특히 파고율을 주로 다루며, 파고율을 줄이기 위한 새로운 방법을 제시하고자 한다. 제안하고자 하는 방법은 펄스 주파수 변조기법(Pulse Frequency Modulation, PFM)을 이용하며, PFC(Power Factor Correction)가 만드는 50% 벨리필 전압 파형을 PFM 제어 신호로 사용한다. 본 논문에서는 제안하는 PFM 제어 기법으로 파고율을 1.7 이하로 낮출 수 있음을 모의 실험과 실험을 통해 확인하여, 제안한 기법의 타당성을 검증한다.

  • PDF

역률 개선을 위한 준 단일 전력단 AC/DC 컨버터 (Quasi-Single Stage Power Factor Correction AC/DC Converter)

  • 권두일;한상규;노정욱;홍성수;사공석진;최흥균;이효범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.182-184
    • /
    • 2007
  • 본 논문에서는 2단 AC/DC 컨버터와 단일단 AC/DC 컨버터가 가지고 있는 단점들을 개선 할 수 있는 새로운 준 단일 전력단 컨버터를 제안한다. DC/DC 단으로는 동적 특성이 좋은 LLC 컨버터를 채용하여 별도의 제어기 없이 고정 주파수 및 고정 Duty(50%) 발생기에 의해 Open Loop로 구동 시킴으로써 저가격화 및 고효율화를 획득 할 수 있다. 또한 역률개선단은 Boost 컨버터를 채용하고 간단한 제어기 1개를 사용하여 역률 개선과 동시에 DC/DC 단의 최종출력을 제어한다. 기존 2단 PFC 컨버터와는 다르게 PFC 링크전압을 Feedback 하지 않고 DC/DC 단의 최종 출력을 Feedback 하여 제어한다. 제안된 회로의 우수성 검증을 위해 600W급 시작품을 이용한 실험 결과를 제시한다.

  • PDF

차량 탑재형 배터리 충전기의 인터리브드 부스트 PFC 컨버터 제어시스템 설계 및 구현 (Design and Implementation of a Control System for the Interleaved Boost PFC Converter in On-Board Battery Chargers)

  • 이준혁;정광순;이경중;정재엽;김호경;홍성수;안현식
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.843-850
    • /
    • 2016
  • In this paper, we propose a digital controller design process for the interleaved type of a boost PFC (Power Factor Correction) converter which can disperse the heat of the switching devices due to the interleaved topology. We establish a mathematical model of a boost PFC converter and propose a controller design method based on the root locus. The performance of the designed controller is verified by simulations. The measurement of the input voltage, inductor currents, and the converter output link voltage are needed for the control of the converter system which consists of a power unit and a control unit where a high-performance 32-bit microcontroller is used. The adjustment of A/D conversion timing is also needed to avoid high frequency noise generated when the switches on/off. It is illustrated by the real experiments that the designed control system with the properly adjusted ADC timing satisfies the given performance specifications of the interleaved boost PFC converter in the on-board slow battery charger.

순시정전보상기능을 가진 PFC 회로 (Power Factor Correction AC/DC Converter with Short-term Blackout Tolerance)

  • 이왕근;정용진;전성즙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.925_926
    • /
    • 2009
  • In this paper, a method to cope with short-term blackout is proposed. The proposed method uses a capacitor bank consisting of supercapacitors. A supercapacitor is a good means for short-term energy storage. The proposed circuit is simple and accordingly easy to construct and to control. A prototype is constructed and experimental results are presented.

  • PDF

역률개선형 부분공진 AC-DC 초퍼에 관한 연구 (A Study on Partial Resonant AC-DC Chopper of Power Factor Correction)

  • 곽동걸
    • 마이크로전자및패키징학회지
    • /
    • 제15권3호
    • /
    • pp.19-25
    • /
    • 2008
  • 본 논문에서는 고역률과 고효율로 동작하는 새로운 스텝-업 AC-DC 초퍼에 대해 제안한다. 제안한 초퍼는 전류 불연속제어로 구동되고, 스위치의 듀티율 일정제어에 의해 입력전류는 교류 입력전압의 크기에 비례된 불연속적인 정현파 형태로 주어진다. 그 결과 입력역률은 거의 단위역률로 되고, 듀티율 일정제어에 의해 제안한 초퍼는 제어기법이 간단하게 된다. 일반적으로 전류불연속 제어에 의한 초퍼의 경우, 사용된 스위치의 턴-온 동작은 영전류 스위칭으로 되는 장점이 있지만, 스위치의 턴-오프 동작은 최대 전류에서 스위칭되어 스위칭 손실을 증대시키고 스위치의 과중한 스트레스를 가져오게 된다. 이것은 AC-DC 초퍼의 효율을 저하시키는 요인이다. 본 논문에서는 부분공진기법에 의한 새로운 소프트 스위칭 회로가 설계되어 사용된 제어스위치들의 턴-온, 턴-오프 동작을 소프트 스위칭으로 만들어 초퍼의 효율을 증대시킨다.

  • PDF

음향 공명 현상을 제거한 MHL용 고출력 전자식 안정기 설계 (High-Power Electronic Ballast Design for Metal-Halide Lamp without Acoustic Resonance)

  • 박종연;김기남;이봉진
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1187-1194
    • /
    • 2008
  • This paper presents a high-power electronic ballast for a metal-hallide lamp(MHL) that employs frequency modulation(FM) technique to eliminate acoustic resonance(AR). The proposed ballast consists of a full-bridge rectifier, a power factor correction(PFC) circuit, a full-bridge(FB) inverter, an ignitor using LC resonance and an FM control circuit. Whereas a manual PFC provides advantages in terms of high reliability and low cost for constructing the circuit, it is difficult to supply a stable voltage because of the output voltage ripple that occurs with a period of 120Hz. Although the ballast can be designed with a small size and a light weight if it is driven at a switching frequency between 1 and 100 kHz, AR will occur if the eigen-value frequency of the lamp coincides with the inverter's operation frequency. The operation frequency was modulated in real time according to the output voltage ripple to compensate for the variation in power supplied to the lamp and eliminate AR. Performance of the proposed technique was validated through numerical analysis, computer simulation using PSPICE and by applying it to an electronic ballast for a prototype 1kW MHL.

단상 브리지리스 배전압 변환기의 역률 개선에 관한 연구 (A Study on the Power Factor Improvement of Single-Phase Bridgeless Voltage Doubler Converter)

  • 구도연;김동욱;임승범;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.169-170
    • /
    • 2011
  • PFC(Power Factor Correction) converters are commonly designed for CCM(Continuous Conduction Mode). However, DCM(Discontinuous Conduction Mode) appears in the input current near the ZCP(Zero Crossing Point) at light loads, resulting in input current distortion. It is caused by inaccurate average current values obtained in DCM. This paper studies a simple digital control scheme that can be operated in both CCM and DCM with minimal changes to the CCM average current control structure.

  • PDF

이중 출력과 단위 역률을 갖는 새로운 단일 전력단 정류기 (A New AC/DC Rectifier Using One Power Circuit for Unity Power Factor and Dual Output Application)

  • 천세환;이동윤;박남주;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.237-239
    • /
    • 2003
  • 이 논문은 이중 출력과 단일 역률 적용에 대한 하나의 전력단 회로를 사용한 새로운 정류기를 나타낸다. 제안된 정류기는 부스트와 플라이백 컨버터가 결합된 하나의 전력단 회로를 갖는 구조를 가지고 있고, PFC(power factor correction) 와 일정 출력 전압 제어를 동시에 수행한다. 따라서, 제안된 정류기는 전형적인 AC/DC 정류기들(멀티 권선을 갖는 플라이 백 정류기, 투 스테이지 방식을 사용한 부스트와 플라이백 컨버터가 결합된 정류기 등등)보다 낮은 비용과 작은 사이즈의 장점을 갖는다. 제안된 정류기 회로의 동자 원리는 본 논문에서 상세하게 기술 되어진다. 그리고 시뮬레이션을 통하여 제안된 정류기의 타당성을 증명하였다.

  • PDF