• 제목/요약/키워드: PET / CT

검색결과 761건 처리시간 0.021초

PET/CT검사에서 CT의 확대 유효시야 적용이 표준화섭취계수에 미치는 영향 (Effect of Extended Field of View on Measurements of Standardized Uptake Value in PET/CT)

  • 박순기;남기표;김경식;신상기
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.82-85
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of extended CT field of view (FOV) on PET/CT of Standardized uptake value (SUV) when imaging extends beyond the CT FOV. Materials and Methods: CT images were reconstructed at different FOV sizes (500 and 700 mm). Two sets of CT images were reconstructed from the CT projection data by using two FOV sizes. Twenty patients were used in this study. PET images were reconstructed using attenuation maps with 500 mm CT FOV and 700 mm extended CT FOV images. Region of interests (ROIs) drawn on the PET images. In addition, twenty patients' PET images reconstructed by 500 mm CT FOV and 700 mm extended CT FOV were compared with $SUV_{max}$. Results: When using attenuation maps with 700 mm extended CT FOV, the $SUV_{max}$ analysis of liver (p=0.000), lung (p=0.007), mediastinum (p=0.001) were statistically significant. Conclusions: 700 mm extended CT FOV helps to recover the true activity distribution in the PET emission data. In addition, 700 mm extended CT FOV has affected SUV measurement of liver, lung, mediastinum.

  • PDF

척추골전이에 있어 F-18 FDG PET/CT에 대한 골스캔의 추가적 역할 및 F-18 FDG PET/CT와 골스캔간에 불일치 병소에 대한 연구 (Value of Bone Scan in Addition to F-18 FDG PET/CT and Characteristics of Discordant lesions between F-18 FDG PET/CT and Bone Scan in the Spinal Bony Metastasis)

  • 전성민;남현열;김인주;김용기;김주성
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권3호
    • /
    • pp.218-228
    • /
    • 2008
  • 목적 : 본 연구의 목적은 골스캔이 없이 FDG PET/CT가 단독으로 척추골전이 평가에 사용될 경우 간과될 수 있는 척추골전이의 양상을 알아보기 위한 것이며 이와 더불어 척추골전이에서 FDG PET/CT와 골스캔간에 불일치 소견을 보이는 병소의 특징을 파악하고자 하는 것이었다. 대상 및 방법 : 척추골전이가 있는 43명의 환자군의 FDG PET/CT와 골스캔을 후향적으로 분석하였다. FDG PET/CT와 골스캔상 불일치하는 소견을 보인 병소를 주의깊게 분석하였다. FDG PET/CT 단독과 골스캔을 참조한 FDG PET/CT 결과들을 McNemar 검정을 이용하여 분석하였다. FDG PET/CT 단독분석상 간과된 척추골전이 병소의 특징을 알아보기 위하여 일방항카이스퀘어 검정을 시행하였다. 척추골전이 병소의 Tc-99m MDP 섭취와 연관이 있는 인자를 확인하기 위하여 로지스틱 회귀분석을 시행하였다. 독립변수는 위치(경추부, 흉추부, 요추부), 전이 병소 크기(큼, 작음), 및 최대 SUV로 설정하였으며, 종속변수는 골스캔의 섭취(양성 및 음성 MDP 섭취)로 하였다. 결과 FDG PET/CT 단독 분석의 결과는 FDG PET/CT와 골스캔을 함께 참조한 경우와 유의하게 달랐다(p<0.01). FDG PET/CT 단독 분석상에서 미만성조골전이는 유의하게 높은 빈도로 간과되는 경향이 있었다(p=0.04). 척추골전이의 Tc-99m MDP 섭취에 연관이 있는 인자를 확인하기 위한 단변량 로지스틱 회귀분석상 경추부 병소 및 작은 전이 병소는 음성 MDP 섭취와 관련이 있었으며, 흉추부 병소 및 큰 전이 병소는 양성 MDP 섭취와 연관이 있었다. 그러나, 다변량 로지스틱 회귀분석상 오직 전이 병소의 크기만이 양성 MDP 섭취와 연관이 있었다(p<0.01). 결론 : 골스캔은 척추골전이 평가에 있어 FDG PET/CT에 추가적인 역할을 하며, 특히 미만성조골전이에서 더욱 그러하다. 척추골전이 병소의 크기와 골스캔상 섭취가 연관이 있는 듯 하다.

병원간 전송용 PET/CT 영상 CD자료의 현황 및 문제점 (Current Status and Problems of PET/CT Data on CD for Inter-hospital Transfer)

  • 현승협;최준영;이수진;조영석;이지영;천미주;조숙경;이경한;김병태
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권2호
    • /
    • pp.137-142
    • /
    • 2009
  • 목적: 이 연구는 $^{18}F$-FDG Positron Emission Tomography/computed Tomography(PET/CT) 영상 검사의 병원간 전송을 위해 사용되는 CD자료의 현황과 문제점에 대해 알아보고자 하였다. 대상 및 방법: 2006년 6월부터 2007년 10월까지 외부 병원에서 시행한 $^{18}F$-FDG PET/CT 검사에 대한 판독 의뢰가 있었던 746명의 환자들을 대상으로 하여, 56개의 병원 PET/CT영상 CD자료에 대해서 조사하였다. 그리고 DICOM표준 형식의 횡단면(transaxial) PET과 CT 영상이 없거나 제한적인 병원들을 대상으로 각 병원의 핵의학과 과장님들께 인터넷 메일을 통해 설문 조사를 실시하였다. 결과: 조사된 병원 전체의 37.5%(21/56)만이 정확한 판독과 진료를 위해 필요한 DICOM 표준 형식의 횡단면 전체 PET 영상과 CT 영상 모두를 제공해 주고 있었다. 나머지 병원들에서는 이차적인 캡쳐(secondary capture image) 영상 또는 PET/CT 융합 영상(fusion image)만으로 구성된 제한적인 영상 자료를 제공해 주고 있었다. 설문조사에는 14개의 병원에서 답변해주었는데 그 중 6개(42.9%) 병원의 핵의 학과에서는 제한적인 영상을 보낸다는 사실을 본 연구의 설문 조사 전에는 제대로 알지 못하고 있었다 나머지 병원들에서 PET/CT 영상 CD자료의 구성이 제한적이게 된 주된 이유는 의료영상저장전송장치(PACS, Picture Archiving and Communication System)의 용량상의 문제로 온전히 모든 PET/CT 영상을 PACS서버에 올리지 않는데, 환자는 PACS에 올라가 있는 영상만 복사해가기 때문이었다. 결론: 현재 각 병원들에서 외부 병원으로 복사하여 보내는 PET/CT영상 자료 CD는 전체 대상 병원의 절반 이상에서 제한적인 영상만을 포함하고 있어서, 외부 병원 영상을 받아서 환자 진료에 이용하는 병원에서는 제한된 영상 정보로 인한 PET/CT 검사의 판독 및 활용 상에 어려움, 재촬영에 따른 추가 의료비 지출이 상당한 문제가 되고 있다. 각 병원들에서 외부 병원으로 보내는 PET/CT 영상 자료에는 DICOM 표준 형식의 전체 횡단면 PET 영상과 전체 횡단면 CT 영상은 최소한 필수적으로 포함시키도록 하는 정부와 학회 차원에서의 PET/CT 영상에 대한 가이드라인 마련이 필요하다.

대장암 치료 후 추적 검사로서 F-18 FDG PET/CT의 역할: 혈청 CEA, CA 19-9 및 Computed Tomography와의 진단 성능 비교 (Diagnostic Role of F-18 FDG PET/CT in the Follow-up of Patients with Colorectal Cancer: Comparison with Serum CEA, CA 19-9 Levels and Computed Tomography)

  • 강성민;송봉일;이홍제;서지형;이상우;유정수;안병철;이재태;최규석;전수한
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권2호
    • /
    • pp.120-128
    • /
    • 2009
  • 목적: 대장암 재발의 조기진단은 생존율을 증가시키는 중요한 인자이다. 대장암의 재발이나 전이를 진단하는데 있어 혈청 CEA, CA 19-9 등의 종양표지 자와 CT 등의 가장 많이 이용되어 왔고 최근 새로운 진단기술로서 PET/CT의 이용이 증가되고 있다. 이 연구에서는 근치적 수술을 포함한 치료를 시행하고 재발이나 전이의 증거가 없었던 상태에서 추적관찰을 받았던 대장암 환자에서 FDG PET/CT의 정기 추적 검사로서의 진단 성능을 혈청 CEA, CA 19-9, CT와 비교하고자 시행하였다 대상 및 방법: 수술적 치료 후 추적관찰 중인 대장암 환자 189명을 대상으로 하였다. PET/CT상에서 관찰된 비정상적인 FDG 섭취 증가 병소는 생검이나 6개월 이상 방사선학적 검사의 추적관찰로서 전이여부 판단하였다. PET/CT시행시기에서 6주 이내에 모든 환자에서 혈청 CEA, 174명의 환자에서 CA 19-9를 측정하였다. 115명의 환자에서 PET/CT 시행 시기 2개월 이내에 CT를 시행하였다. PET/CT 상에서 관찰된 비정상적인 FDG 셥취 증가 병소는 생검이나 6개월 이내의 방사선학적 검사와 임상적 진단의 추적 관찰로 재발이나 전이 병소로 진단하였다. 결과: 국소적 재발 및 전이가 발견된 환자는 76명(40.2%)이었다. 재발 또는 전이 병소는 총 81개였고 간과 폐에서 29개와 16개로 가장 많이 나타났다. PET/CT의 민감도, 특이도, 양성예측도, 음성예측도는 94.7%, 91.1%, 87.8%, 96.2%이고 혈청 CEA 치수는 44.7%, 97.3%, 91.8%, 72.3%였다. 종양표지 자와 PET/CT와의 비교에서는 PET/CT가 종양표지 자보다 민감도(94.2%, 52.1%)와 특이도(90.4%, 88.5%)가 높았다. 종양표지자와 CT를 종합하여 PET/CT와 비교하였을 때 민감도는 92.9%로 동일하였지만 특이도는 PET/CT가 91.3%로 높았다. 결론: 이러한 결과로 보아 FDG PET/CT가 근치적 절제술 후 대장암의 정기적 추적 관찰에도 유용하게 이용될 수 있을 것이다.

Value of FDG PET/Contrast-Enhanced CT in Initial Staging of Colorectal Cancer - Comparison with Contrast-Enhanced CT

  • Kunawudhi, Anchisa;Sereeborwornthanasak, Karun;Promteangtrong, Chetsadaporn;Siripongpreeda, Bunchorn;Vanprom, Saiphet;Chotipanich, Chanisa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권8호
    • /
    • pp.4071-4075
    • /
    • 2016
  • Background: FDG PET/CT is at an equivocal stage to recommend for staging of colorectal cancer as compared to contrast-enhanced CT (ceCT). This study was intended to evaluate the value of FDG PET/ceCT in colorectal cancer staging as compared to ceCT alone. Materials and Methods: PET/ceCT was performed for 61 colorectal cancer patients who were prospectively enrolled in the study. Three patients were excluded due to loss to follow-up. PET/ceCT findings and ceCT results alone were read separately. The treatment planning was then determined by tumor board consensus. The criteria for T staging were determined by the findings of ceCT. Nodal positive by PET/ceCT imaging was determined by visual analysis of FDG uptake greater than regional background blood pool activity. The diagnostic accuracy of T and N staging was determined only in patients who received surgery without any neoadjuvant treatment. Results: Of 58 patients, there were 40 with colon cancers including sigmoid cancers and 18 with rectal cancers. PET/ceCT in pre-operative staging detected bone metastasis and metastatic inguinal lymph nodes (M1a) that were undepicted on CT in 2 patients (3%), clearly defined 19 equivocal lesions on ceCT in 18 patients (31%) and excluded 6 metastatic lesions diagnosed by ceCT in 6 patients (10%). These resulted in alteration of management plan in 15 out of the 58 cases (26%) i.e. changing from chemotherapy to surgery (4), changing extent of surgery (9) and avoidance of futile surgery (2). Forty four patients underwent surgery within 45 days after PET/CT. The diagnostic accuracy for N staging with PET/ceCT and ceCT alone was 66% and 48% with false positive rates of 24% (6/25) and 76% (19/25) and false negative rates of 47% (9/19) and 21% (4/19), respectively. All of the false negative lymph nodes from PET/ceCT were less than a centimeter in size and located in peri-lesional regions. The diagnostic accuracy for T staging was 82%. The sensitivity of the peri-lesional fat stranding sign in determining T3 stage was 94% and the specificity was 54%. Conclusions: Our study suggested promising roles of PET/ceCT in initial staging of colorectal cancer with better diagnostic accuracy facilitating management planning.

F-18 FDG PET/MRI와 PET/CT 전신 영상에서 VOI를 이용한 정상부위의 $SUV_{LBM}$-최대치에 의한 영상평가 (Image Evaluation Via $SUV_{LBM}$ for Normal Regions of VOI by Using Whole Body Images Obtained from PET/MRI and PET/CT)

  • 박정규;김성규;조인호;공은정;박명환
    • 한국의학물리학회지:의학물리
    • /
    • 제24권1호
    • /
    • pp.68-75
    • /
    • 2013
  • 본 연구의 목적은 26명의 건강한 검진자들을 대상으로 PET/CT와 PET/MRI의 전신 영상에서 조기 정밀/ 진단 수준을 향상하고자 관심부피를 이용하여 정상부위의 $SUV_{LBM}$-최대치를 이용하여 PET/CT와 PET/MRI를 조영제 사용 유무와 관계없이 동시 평가할 수 있는 데이터를 구축하고자 하였다. 전신 F-18 FDG PET/CT와 전신 F-18 FDG PET/MRI의 정상부위의 VOI를 이용한 $SUV_{LBM}$-최대치평가는 PET/CT를 기준으로 PET/MRI의 영상은 매우 유의한 차이를 보였다(p<0.0001). 그러나 통계학적으로 높은 상관관계를 가진다(R>0.8). PET/MRI의 $SUV_{LBM}$ 평가 시 26.3% 감소하여 판단할 것과 조영제를 사용할 경우는 29.3% 감소하여 판단할 것으로 생각한다. PET/CT와 PET/MRI의 모든 영상의 판독에서는 $SUV_{LBM}$-최대치를 사용하는 것이 편리성과 효율성을 고려하여 임상의나 연구자들에게 많은 도움이 되리라 판단된다.

CT와 $^{68}Ge$ 감쇠보정 $^{18}F-FDG$ PET 영상의 정량적 비교: 측정감쇠보정대 분할감쇠보정 (Quantitative Comparisons between CT and $^{68}Ge$ Transmission Attenuation Corrected $^{18}F-FDG$ PET Images: Measured Attenuation Correction vs. Segmented Attenuation Correction)

  • 최준영;우상근;최용;최연성;이경한;김병태
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권1호
    • /
    • pp.49-53
    • /
    • 2007
  • 목적: CT를 사용한 측정감쇠보정(measured attenuation correction; CT-MAC) PET 영상은 $^{68}Ge$을 사용한 분할감쇠보정(segmented attenuation correction; Ge-SAC) PET 영상보다 섭취값이 높은 것으로 알려져 있다. 이 연구에서는 정상인과 암으로 진단된 또는 암이 의심되는 환자를 대상으로 $^{18}F-FDG$ PET을 시행하고, 감쇠보정방법을 달리하여 각각 4가지 PET 영상을 얻고 이를 서로 정량적으로 비교하였다. 대상 및 방법: 5명의 정상인(남:여=4:1; 평균나이, $29.4{\pm}2.5$세)과 35명의 환자(남17, 여18; 평균나이 $52.7{\pm}15.2$세)를 대상으로 $^{18}F-FDG$ PET을 시행하였다. 먼저, CT 영상(140 KeV, 80 mAs)을 얻은 뒤 방출영상(5 min/bed)과 $^{68}Ge$ 투과영상(3 min/bed)을 차례로 얻었다. Ordered subsets expectation maximization (28 subsets, 2 iterations) 영상재구성법과 CT-MAC, CT-SAC, Ge-MAC, Ge-SAC의 4가지 감쇠보정방법을 사용하여 4가지 PET 영상을 얻었다. 정상인군에서는 대표적인 정상조직의, 환자군에서는 비정상적인 섭취를 보이는 병소의 SUV를 구하고, 이를 서로 비교 하였다. 결과: 정상인 군에서 CT-MAC 사용하여 감쇠보정한 PET 영상의 18개 정상조직의 SUV는 나머지 3가지 종류의 PET 영상에 비하여 모두 유의하게 높았다($3.1%{\sim}4.1%$; p<0.001). 환자군에서는 총 145개 병소의 국소 FDG 섭취증가 병변이 발견되었다. CT-MAC 사용한 PET 영상의 SUV 값은 나머지 3가지 PET 영상에 비하여 모두 유의하게 높았다($2.4%{\sim}5.1%$; p<0.001). Ge-MAC 사용한 PET 영상의 SUV 값은 CT-SAC와 Ge-SAC 사용한 PET 영상에 비하여 유의하게 높았다(p<0.001). 그러나, CT-SAC와 Ge-SAC PET 영상사이의 SUV에는 유의한 차이가 없었다. 폐병변에서는 감쇠보정방법사이에 섭취값이 유의한 차이가 없는 반면, 뼈병변에서는 이러한 차이가 가장 컸다($3.8%{\sim}9.6%$; p<0.01). 결론: $^{18}F-FDG$ PET 영상에서 섭취값은 CT-MAC로 감쇠보정을 했을 때에 가장 높다. CT 감쇠보정 및 MAC 사용, 2가지 모두가 이 차이에 기여했을 것이며, 이 중 MAC 사용이 더 크게 작용한 것으로 보인다. 감쇠보정방법이 다른 PET 영상들사이의 섭취값을 비교할 때는 이러한 차이를 고려해야 할 것이다.

관상동맥질환에서 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT의 임상 유용성 비교 (Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPET in Coronary Artery Disease)

  • 공은정;조인호;천경아;원규장;이형우;박종선;신동구;김영조;심봉섭
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권5호
    • /
    • pp.354-361
    • /
    • 2008
  • 목적: 암모니아의 심근섭취는 심근의 관류나 생존능 및 대사에 관계되어 있으며, N-13 암모니아 PET은 심근의 허혈을 진단하는 데에 유용한 것으로 알려져 있다. 그러나, 아데노신을 이용한 약물부하 심근관류 검사로 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT 검사를 비교한 연구는 없었다. 이 연구에서는 관상동맥질환이 의심되는 환자에게서 아데노신 약물부하로 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT를 시행하여 두 검사의 차이를 비교분석하여 N-13 암모니아 PET/CT의 임상 유용성을 알아보았다. 대상 및 방법: 관상동맥질환이 의심되는 환자 중 Tc-99m 세스타미비 SPECT와 N-13 암모니아 PET/CT를 동시에 시행할 수 있었고, 검사 1주일 이내 관상동맥조영술을 시행하였던 17명의 환자(남자:13명, 평균연령 $63{\pm}11$세)를 대상으로 하였다. 아데노신약물 부하 후 N-13 암모니아 PET/CT와 Tc-99m 세스타미비를 검사하여 육안 분석과 정량분석을 실시하였다. 결과: 관상동맥조영술에서 50% 이상의 협착이 확인된 관상동맥의 진단에 대한 민감도와 특이도는 N-13 암모니아 PET/CT는 91%와 89%로, Tc-99m세스타미비 SPECT는 65%와 82%로 각각 나타났다. 또한 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT는 전체에 238분절 중 65%인 154분절에서 동일한 결과를 보였으며, N-13 암모니아 PET/CT는 Tc-99m 세스타미비 SPECT에서 비가역적인 관류결손을 보였던 병변 중 54%에 대하여 가역적인 관류결손을 나타내었다. 협착혈관이 관장하는 심근부위에 해당하는 110개의 분절에 대하여 부하기와 휴식기의 계수를 N-13 암모니아 PET/CT와 Tc-99m세스타미비 SPECT에서 각각 비교하였을 때, 부하기의 비교에서는, 두 검사간에 유의한 차이를 보이지 않았으나, 휴식기에서는 N-13 암모니아 PET/CT의 계수가 Tc-99m세스타미비 SPECT의 계수보다 높았으며 (p<0.01), 휴식기와 부하기의 계수의 차이도 N-13 암모니아 PET/CT가 Tc-99m 세스타미비 SPECT보다 큰 것으로 나타났다(p<0.01). 결론: N-13 암모니아 PET/CT는 Tc-99m 세스타미비 SPECT보다 관상동맥질환의 진단이 정확하고, 가역적인 관류결손을 보인 분절의 수가 많으며, 휴식-부하 관류차이도 현저하여, 관상동맥질환의 정확한 진단과 함께 심근의 허혈이나 생존능을 더욱 잘 반영하는 것으로 사료된다.

팬텀을 이용한 소아 PET/CT 검사 시 감쇄보정 CT 선량과 영상 평가 (Evaluation of Dosimetry and Image of Very Low Dose CT Attenuation Correction for Pediatric PET/CT: Phantom Study)

  • 반영각;김정열;박훈희;강천구;임한상;이창호
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.53-59
    • /
    • 2011
  • 최근 PET/CT 검사는 성인 암환자뿐만 아니라 소아 암환자에게도 많이 적용하고 있다. 그러나 소아 환자의 경우 성인에 비하여 방사성 감수성이 높아 피폭선량의 관리를 필요로 하고 있다. 그러므로 본 저자는 팬텀을 이용하여 소아 PET/CT 검사 시 감쇄보정 CT 선량과 영상을 평가하였다. 3대의 PET/CT 장비 (Discovery STe, BiographTruepoint 40, Discovery 600)로 소아 사이즈의 아크릴 팬텀과 이온 챔버 선량계 (Unfous Xi CT, Sweden)를 이용하여 CT 영상획득 조건 (10, 20, 40, 80, 100, 160 mA; 80, 100, 120, 140 kVp)을 변화시켜 심부선량과 $CTDI_{vol}$ 값을 평가하였다. 그리고 NEMA PET Phantom$^{TM}$을 이용하여 같은 CT 조건으로 PET 영상을 획득하여 감쇄보정 된 각 PET 영상을 SUV 값과 신호 대 잡음 비로 평가하였다. 심부선량은 일반적으로 소아복부 CT 조건 (100 kVp, 100 mA) 보다 최소 CT 조건 (80 kVp, 10 mA)에서의 심부선량은 약 92% 감소 되었고, $CTDI_{vol}$ 값은 약 88% 감소되었다. 각 CT 조건에 따라 감쇄 보정된 PET 영상은 SUV 값에 변화가 없었고, 신호 대 잡음 비도 영향을 받지 않았다. 팬텀을 이용한 소아 PET/CT 실험시 최저 선량 CT 조건 (80 kVp, 10 mA) 을 적용하여 감쇄보정을 진행한 PET 영상에는 영향 없었다. 소아 환자의 PET/CT 검사 시 CT 의 진단이 필요 없는 PET 영상만을 획득하고자 한다면, 소아 환자의 신체에 적절히 적용한 최저선량 CT 을 감쇄보정을 하여, 유효 선량을 성인에 비하여 약 90% 이상 감소시켜 피폭 선량 저감에 도움이 될 것이다.

  • PDF

진단용 고선량 CT를 이용한 $^{18}F$-FDG PET/CT 촬영시 정맥 조영제가 SUV 값에 미치는 영향 (The Effect of Intravenous Contrast on SUV Value in $^{18}F$-FDG PET/CT using Diagnostic High Energy CT)

  • 정영진;강도영
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권3호
    • /
    • pp.169-176
    • /
    • 2006
  • 목적 : 현재 PET/CT에서 CT의 역할은 단순히 감쇠 보정만을 위한 도구에서 진단을 위한 도구로 그 역할이 발전해 가고 있다. 따라서 양질의 CT 영상을 얻기 위한 정맥 조영제의 사용과 고선량의 CT 촬영이 요구되고 있으며 최근 조영제가 감쇠 보정한 PET 영상에 크게 영향을 미치지 않는다는 보고가 나오고 있다. 이에 본 연구에서는 고선량 CT에서 정맥 조영제의 사용이 감쇠 보정에 미치는 영향을 알아보았다. 대상 및 방법 : 총 13명의 환자에게 PET/CT 검사를 시행하였다. $^{18}F$-FDG를 주사하고 1시간 후에 촬영하였고, 첫 번째로 조영제의 사용 없이 CT(NECT-120 kVp, 130 mAs)를 촬영하고 이어서 바로 조영제를 사용하여 CT(CECT)를 촬영한 후 PET을 시행하였다. 각 환자마다 NECT와 CECT에 의해 각각 보정된 PET 영상에서 10곳의 신체 부위(병변이 없는 폐첨부, 폐기저부, 상행대동맥, 간의 상부 및 하부, 비장, 척추, 대퇴골두, 장요근과 10번 척추와 척추 인접 근육) 에서 HU와 maxSUV 값을 구하였고, 종양과 임파선 병변의 값도 함께 측정하였다. 결과: 조영제를 사용하였을 때 국소적으로 섭취가 증가된 곳은 관찰되지 않았다. 총 130개의 정상 조직의 maxSUV값을 측정하여 비교하였을 때, 조영제를 사용한 군과 사용하지 않은 군의 평균 maxSUV 값은 각각 $1.1{\pm}0.5,\;1.0{\pm}0.5$이고 두 군 사이에 p<0.001로 통계적으로 유의한 차이를 보였다. 정상 조직에 대해 Bland-Altman 분석을 시행하였을 때 일치의 한계 범위는 $0.1{\pm}0.3$ 이었다. 10개의 대상 영역 중 폐첨부, 폐하부, 상행대동맥, 간의 상부와 하부, 비장에서 maxSUV 값이 두군에서 유의한 차이(p<0.05)가 있었다. 총 39개 병변의 maxSUV 값을 측정하여 비교하였을 때, 조영제를 사용한 군과 사용하지 않은 군의 평균 maxSUV값은 각각 $4.7{\pm}2.0,\;4.4{\pm}2.0$이고 두 군 사이에 p<0.001로 통계적으로 유의한 차이를 보였다. 병변에 대해 Bland-Altman 분석을 시행하였을 때 일치의 한계 범위는 $0.4{\pm}0.8$ 이었다. 결론: 조영제로 인해 maxSUV의 값은 증가되었으나 정상 조직과 병변에서 일치의 한계 범위가 매우 좁았다. 따라서 진단용 고선량 CT를 이용한 PET/CT 촬영 시에 조영제의 사용이 임상 상황에서 판독에 큰 영향을 미치지 않는 것으로 생각된다.