• Title/Summary/Keyword: PEM 수전해

Search Result 27, Processing Time 0.027 seconds

Influence of Operation Conditions on the Performance of PEM Water Electrolysis (운전조건이 PEM 수전해 셀의 성능에 미치는 영향)

  • Sangyup Jang;Jaedong Kim;Jinmo Park;Youngseuk So
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.65-72
    • /
    • 2024
  • Green Hydrogen demonstration complex is under conduction in Jeju island which is rich in renewable energy resources and will produces green hydrogen using a water electrolysis systems. In order to check durability of long-term operation, AST(accelerated stress test) was applied and the power pattern based on Jeju Island's wind power was applied. After 800 hours of repeated application of low current and high current, the performance of the PEM water electrolysis cell was reduced by up to 10% and by about 5.5% in operating conditions. As the result of impedance analysis, it can be seen that the electrode polarization resistance greatly increased than ohmic polarization resistance. In addition, when the durability evaluation was conducted by applying the wind power pattern of Jeju Island, the performance of the PEM water electrolysis cell showed up to 1.6% and a decrease of less than 1% in operating conditions. As a result of the impedance, it can be seen that the change of ohmic resistance and electrode polarization resistance is small.

Degradation Evaluation of PEM Water Electrolysis by Method of Degradation Analysis Used in PEMFC (고분자전해질 연료전지 열화 분석방법에 의한 PEM 수전해 열화 평가)

  • Oh, Sohyeong;Yang, Jinwon;Chu, Cheun-Ho;Na, Il-Chai;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.1-5
    • /
    • 2021
  • The PEM(Proton Exchange Membrane)water electrolysis uses the same PEM electrolyte membrane as the PEM fuel cell and proceeds by the same reaction but the opposite direction. The PEM fuel cell has many methods of degradation analysis since many studies have been conducted on the degradation and durability of the membrane and catalyst. We examined whether PEM fuel cell durability evaluation method can be applied to PEM electrolytic durability evaluation. During the PEM electrolytic degradation process, LSV(Linear sweep voltammetry), CV(Cyclic voltammetry), Impedance, SEM(Scanning Electron Microscope) and FT-IR(Fourier Transform Infrared spectroscopy) were analyzed and compared under the same conditions as the PEM fuel cell. As the PEM fuel cell, hydrogen passing through the membrane was oxidized at the Pt/C electrode, and the hydrogen permeation current density was measured to analyze the degree of degradation of the PEM membrane. Electrode degradation could be analyzed by measuring the electrode active area (ECSA) by CV under hydrogen/nitrogen flowing conditions. While supplying hydrogen and air to the Pt/C electrode and the IrO2 electrode, the impedance of each electrode was measured to evaluate the durability of the electrode and membrane.

Effect of Number of Shutdown on the Decrease of Performance in PEM Water Electrolysis (PEM 수전해에서 정지횟수가 성능 감소에 미치는 영향)

  • Cheunho Chu;Jongwon Yang;Ilchai Na;Yoonjin Park
    • Korean Chemical Engineering Research
    • /
    • v.61 no.2
    • /
    • pp.202-207
    • /
    • 2023
  • In the case of driving water electrolysis by receiving surplus electricity from solar and wind power generation, operation and stopping must be repeated according to weather fluctuations. When the PEMWE(Polymer Electrolyte Membrane Water Electrolysis) is driven and stopped, the PEM fuel cell is in the same state as the PEM fuel cell due to the residual hydrogen and oxygen, and the high potential of the water electrolysis formed during operation is highly likely to cause degradation of the electrode and membrane even during stopping. In this study, in order to check how much degradation of the electrode and membrane progresses during the repeated driving/shutdown process of PEM water electrolysis, the performance decrease was measured by changing the number of driving/shutdown for 144 hours. Changes in electrode catalyst active area, hydrogen permeability and fluorine emision rate of membranes were analyzed to measure changes in the properties of electrodes and polymer membranes. Overall, the PEMWE performance decreased as the number of stops increased. When stopped 5 times in 144 hours, the IrOx catalyst activity decreased by more than 30%, and the hydrogen permeability increased by 80%, confirming that both the electrode and the membrane were deteriorated.

Effect of Operation Temperature on the Durability of Membrane and Electrodes in PEM Water Electrolysis (PEM 수전해에서 막과 전극의 내구성에 미치는 구동 온도의 영향)

  • Donggeun Yoo;Seongmin Kim;Byungchan Hwang;Sohyeong Oh;Kwonpil Park
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.19-25
    • /
    • 2023
  • Although a lot of research and development has been conducted on the performance improvement of PEM (Proton Exchange Membrane) water electrolysis, the research on durability is still in early stage. This study investigated effect of temperature on the water electrolysis durability when driving temperature of the PEM water electrolysis was increased to improve performance. Voltage change, I-V, CV (Cyclic Voltammetry), LSV (Linear Sweep Voltammetry), Impedance, and FER (Fluoride Emission Rate) were measured while driving under a constant current condition in a temperature range of 50~80 ℃. As the operating temperature increased, the degradation rate increased. At 50~65 ℃, the degradation of the IrO2 electrocatalyst mainly affected the durability of the PEM water electrolysis cell. At 80 ℃, the polymer membrane and electrode degradation proceeded similarly, and the short resistance decreased to 1.0 kΩ·cm2 or less, and the performance decreased to about 1/3 of the initial stage after 144 hours of operation due to the shorting phenomenon.

A Study on the Analysis of Hazardous Risk Factors for Component in Hydrogen Station with Water Electrolysis Device (수전해 수소충전소 부품별 유해위험요인 분석)

  • Seo, Doo-Hyoun;Rhie, Kwang-Won;Kim, Tae-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.33-38
    • /
    • 2019
  • In order to invigoration the hydrogen economy, production of hydrogen needed for hydrogen charging stations and hydrogen fuel cells is needed. Generally, it is reforming used to coal fuel or natural gas. Other technologies include water electrolysis using pure water. Among these water electrolysis technologies, development is mainly carried out using PEM(Polymer Electrolyte Membrane electrolysis). In this study, the company aims to identify potential harmful hazards to PEM electrolysis hydrogen stations in the development stage among hydrogen charging stations. In order to find the hazardous factors in the facilities of the electrolysis and hydrogen charging stations, we were analyzed by Failure Mode & Effect Analysis(FMEA).

Economic Feasibility Analysis for P2G Using PEM Water Electrolysis (PEM 수전해를 이용한 P2G에 대한 경제적 타당성 분석)

  • JEONG, SEONJU;CHOI, NAK HEON;MOON, CHANGHWAN;MOON, SANGBONG;LIM, HANKWON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.3
    • /
    • pp.231-237
    • /
    • 2017
  • With worldwide efforts to increase the portion of renewable energy for $CO_2$ reductions, a lot of attention has been paid to P2G (power-to-gas) in Europe and Japan to efficiently utilize the surplus electricity. In this paper, economic feasibility analysis has been carried out for P2G using PEM water electrolysis by reflecting current economic status in Korea. In addition, efficiency and electricity price required to be competent in Korean market were provided. Based on cash flow diagrams, unit production costs for $H_2$ and $CH_4$ were estimated and profitability of P2G using PEM water electrolysis was analyzed.

Understanding Thermodynamics of Operating Voltage and Efficiency in PEM Water Electrolysis System for Carbon Neutrality and Green Hydrogen Energy Transition (탄소중립과 그린 수소에너지 전환을 위한 PEM 수전해 시스템에서 작동 전압 및 효율의 열역학적 이해)

  • HyungKuk Ju;Sungyool Bong;Seungyoung Park;Chang Hyun Lee
    • Journal of the Korean Electrochemical Society
    • /
    • v.26 no.4
    • /
    • pp.56-63
    • /
    • 2023
  • The development of renewable energy technologies, such as solar, wave, and wind power, has led to the diversification of water electrolysis technologies, which can be easily coupled with renewable energy sources in terms of economics and scale. Water electrolysis technologies can be classified into three types based on operating temperature: low-temperature (<100 ℃), medium-temperature (300-700 ℃), and high-temperature (>700 ℃). It can also be classified by the type of electrolyte membrane used in the system. However, the concepts of thermodynamic and thermo-neutral voltages calculations and are very important factors in the evaluation of energy consumption and efficiency of water electrolysis technologies, are often confused. This review aims to contribute to a better understanding of the calculation of operating voltage and efficiency of PEM water electrolysis technologies and to clarify the differences between thermodynamic voltage and thermo-neutral voltage.

그린수소 생산을 위한 수전해기 소재부품 개발 동향과 뿌리기술 적용 방안

  • Kim, Yeong-Su
    • Bulletin of the Korea Photovoltaic Society
    • /
    • v.7 no.2
    • /
    • pp.22-28
    • /
    • 2021
  • 최근 잇따라 발생하고 있는 이상 기후로 탄소 중립에 대한 관심이 높아지고 있다. 우리나라 정부도 신재생에너지 중심의 에너지 전환과 수소 경제 활성화에 대한 정책을 연일 발표하면서 많은 국책 과제들이 추진되고 있다. 잉여 재생에너지를 수소 가스로 변환하여 저장했다가 필요할 때 다시 전기로 사용하거나, 수소 가스 자체를 타 산업에 활용할 수 있게 해주는 핵심 기술이 수전해 기술이다. 다양한 수전해 기술 중에 PEM 수전해 기술은 재생에너지의 빠른 변동에 신속하게 대응할 수 있어 재생에너지 확산과 더불어 최근 높은 관심을 받고 있는 기술이다. 그러나 비싼 촉매와 내부식성이 필요한 핵심 부품들이 국산화 되어 있지 않아 장치의 가격이 높은 상황이다. 그에 따라 아직은 수전해를 통해 생산된 수소 단가가 다른 기술을 통해 생산된 수소들 보다 가격이 높아 상업화가 더디게 진행되고 있다. 그러나 정밀 가공, 열처리, 코팅 등의 뿌리 기술들을 이용하면 PEM 수전해기의 핵심 부품인 bipolar plate나 end plate, 분리판 등을 국산화 하여 수소 생산 단가를 낮출 수 있는 여지는 충분하다. 탄소 중립에 반드시 필요한 그린 수소가 가격 경쟁력을 확보할 수 있도록 산업간 기술 협력이 절실한 시점이다.

Development of a Fault Diagnosis Model for PEM Water Electrolysis System Based on Simulation (시뮬레이션 기반 PEM 수전해 시스템 고장 진단 모델 개발)

  • TEAHYUNG KOO;ROCKKIL KO;HYUNWOO NOH;YOUNGMIN SEO;DONGWOO HA;DAEIL HYUN;JAEYOUNG HAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.5
    • /
    • pp.478-489
    • /
    • 2023
  • In this study, fault diagnosis and detection methods developed to ensure the reliability of polymer electrolyte membrane (PEM) hydrogen electrolysis systems have been proposed. The proposed method consists of model development and data generation of the PEM hydrogen electrolysis system, and data-driven fault diagnosis learning model development. The developed fault diagnosis learning model describes how to detect and classify faults in the sensors and components of the system.

Recent Progress on Proton Exchange Membrane Based Water Electrolysis (수소이온 교환막 기반 수전해의 최근 연구 동향)

  • Yang, Seungmin;Rajkumar, Patel
    • Membrane Journal
    • /
    • v.32 no.5
    • /
    • pp.275-282
    • /
    • 2022
  • In contemporary days, hydrogen-based energies including batteries are renowned to be effective. And its effectiveness comes from the fact that it possesses high efficiency as an energy carrier. Eco-friendly and high purity of hydrogens comes out from water electrolysis. And among different types of electrolysis, proton exchange membrane (PEM) water electrolysis is considered the most renewable, cheap, and eco-friendly. It produces oxygen and hydrogens which are feasible in using as energies. Since it has such a number of benefits, increased research is going on in PEM electrolysis. Nafion is widely used as PEM, but high cost and various other disadvantages leads to the exploration of alternative materials. This review is broadly classified into Nafion and non Nafion based PEM for water electrolysis.