• Title/Summary/Keyword: PELD

Search Result 26, Processing Time 0.024 seconds

A Study on Dot-Matrix Display using Powder Electroluminescent Device with High Brightness (고휘도 후막 전계발광소자을 이용한 Dot-Matrix Display에 대한 연구)

  • Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1255-1257
    • /
    • 1998
  • In this study,$ 5{\times}5$ dot-matrix display was implemented with powder electroluminescent device (PELD). Generally PELD which have a luminance from powder phosphor with electric field, inserted phosphor and dielectric layer between electrodes is basic structure. To make high brightness PELD compared to conventional device, new type of PELD was proposed as follows. New PELD had only one layer, which was mixed phosphor (ZnS:Cu) and dielectric (BaTiO3) material appropriately between electrodes. To compare and estimate the conventional and new type of PELD, the EL spectrum, transferred charge density, brightness and decay time was measured. As above result, we fabricated a hish brightness $ 5{\times}5$ dot-matrix display with new type of PELD. Its brightness was 6400 $cd/m^2$ at 200 V, 400Hz.

  • PDF

Comparison of Percutaneous Endoscopic Lumbar Discectomy and Open Lumbar Microdiscectomy for Recurrent Disc Herniation

  • Lee, Dong-Yeob;Shim, Chan-Shik;Ahn, Yong;Choi, Young-Geun;Kim, Ho-Jin;Lee, Sang-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.515-521
    • /
    • 2009
  • Objective : The purpose of this study was to compare clinical and radiological outcomes of percutaneous endoscopic lumbar discectomy (PELD) and open lumbar microdiscectomy (OLM) for recurrent disc herniation. Methods : Fifty-four patients, who underwent surgery, either PELD (25 patients) or repeated OLM (29 patients), due to recurrent disc herniation at L4-5 level, were divided into two groups according to the surgical methods. Excluded were patients with sequestrated disc, calcified disc, severe neurological deficit, or instability. Clinical outcomes were assessed using Visual Analogue Scale (VAS) score and Oswestry Disability Index (ODI). Radiological variables were assessed using plain radiography and/or magnetic resonance imaging. Results : Mean operating time and hospital stay were significantly shorter in PELD group (45.8 minutes and 0.9 day, respectively) than OLM group (73.8 minutes and 3.8 days, respectively) (p < 0.001). Complications occurred in 4% in PELD group and 10.3% in OLM group in the perioperative period. At a mean follow-up duration of 34.2 months, the mean improvements of back pain, leg pain, and functional improvement were 4.0, 5.5, and 40.9% for PELD group and 2.3, 5.1, and 45.0% for OLM group, respectively. Second recurrence occurred in 4% after PELD and 10.3% after OLM. Disc height did not change after PELD, but significantly decreased after OLM (p = 0.0001). Neither sagittal rotation angle nor volume of multifidus muscle changed significantly in both groups. Conclusion : Both PELD and repeated OLM showed favorable outcomes for recurrent disc herniation, but PELD had advantages in terms of shorter operating time, hospital stay, and disc height preservation.

The Clinical Comparison between Open Surgery and Percutaneous Endoscopic Lumbar Discectomy in Extraforaminal Lumbar Disc Herniation

  • Jeong, Jin-Seok;Lee, Sang-Ho;Lee, Sang-Jin;Hwang, Byeong-Wook
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.6
    • /
    • pp.413-418
    • /
    • 2006
  • Objective : The objective of this study is to evaluate and compare the clinical results between classical open surgery and percutaneous endoscopic lumbar discectomy[PELD] in cases of extraforaminal lumbar disc herniation. Methods : We obtained the clinical data from 47 patients with extraforaminal lumbar disc herniations who underwent the open paramedian muscle-splitting approach or percutaneous endoscopic lumbar discectomy[PELD] between January 2001 and February 2004. This study consisted of patients with soft disc extraforaminal herniations. The patients were assessed with the visual analogue scale[VAS] and MacNab's criteria before surgery, just before discharge, and postoperative 1 year. Results : There were 25 cases in the open surgery group and 22 cases in the PELD group. The average operating time was $78{\pm}36.71\;min$ in the PELD group and $110{\pm}29.68\;min$ in the open surgery group. The mean hospital stay was $2.73{\pm}2.62$ days in the PELD group and $7.68{\pm}2.59$ days in the open surgery group. VAS decreased from $8.34{\pm}0.66$ to $1.29{\pm}2.27$ in the PELD group and from $8.40{\pm}1.40$ to $1.70{\pm}1.72$ in the open surgery group at the one-year follow-up. The success rate of PELD was 86.4%, compared with 80.0% for open surgery. However, there were no statistically significant difference between two groups for success rate and VAS. Conclusion : Although the success rates were similar in both groups, PELD is less invasive, faster, and safe procedure than open surgery for extraforaminal disc herniation in selected patients.

A Emission Property of Powder EL device at 60Hz (상용주파수(60Hz)에서 후막 EL소자의 발광특성)

  • 오주열;정병선;이종찬;박대희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.303-306
    • /
    • 1998
  • Electroluminescence is occurred when phosphor is located in electric field. Object of this research show powder electroluminescent device (PELD) for high brightness compared with conventional PELD. Single layer of PELD structured as follow (ITO/phosphor + dielectric/silver paste). To investigate optical properties of PELDS, EL spectrum, CIE coordinate system, Brightness of PELDs was measured. The suitable ratio between phosphor and dielectric in single layer of PELD was 7:3(phosphor: dielectric). At 200 V4OO Hz, high performance of PELD which had ratio of 7:3

  • PDF

A Study on Powder Electroluminecscent Device for High Brightness (고휘도 후막 전계발광소자에 관한 연구)

  • Oh, Joo-Youl;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1382-1384
    • /
    • 1998
  • Electroluminescence is occurred when phosphor is located in electric field. Object of this research show new type of powder electroluminescent device (PELD) for high brightness compared with conventional PELD. New type of PELD structured as follow ITO/phosphor + dielectric/Silver paste). To investigate optical properties of PELDs, EL spectrum, CIE coordinate system, Brightness of PELDs was measured. The suitable ratio between phosphor and dielectric in new type of PELD was 7:3(phosphor:dielectric). At 200 V 400 Hz, new type of PELD which had ratio of 7:3 was 5700 cd/$m^2$.

  • PDF

Evaluation of an Experimentally Designed Stereotactic Guidance System for Determining Needle Entry Point during Uniplanar Fluoroscopy-guided Intervention

  • Lee, Jae-Heon;Jeon, Gye-Rok;Ro, Jung-Hoon;Byoen, Gyeong-Jo;Kim, Tae-Kyun;Kim, Kyung-Hoon
    • The Korean Journal of Pain
    • /
    • v.25 no.2
    • /
    • pp.81-88
    • /
    • 2012
  • Background: In discography performed during percutaneous endoscopic lumbar discectomy (PELD) via the posterolateral approach, it is difficult to create a fluoroscopic tunnel view because a long needle is required for discography and the guide-wire used for consecutive PELD interrupts rotation of fluoroscope. A stereotactic system was designed to facilitate the determination of the needle entry point, and the feasibility of this system was evaluated during interventional spine procedures. Methods: A newly designed stereotactic guidance system underwent a field test application for PELD. Sixty patients who underwent single-level PELD at L4-L5 were randomly divided into conventional or stereotactic groups. PELD was performed via the posterolateral approach using the entry point on the skin determined by premeasured distance from the midline and angles according to preoperative magnetic resonance imaging (MRI) findings. Needle entry accuracy provided by the two groups was determined by comparing the distance and angle measured by postoperative computed tomography with those measured by preoperative MRI. The duration and radiation exposure for determining the entry point were measured in the groups. Results: The new stereotactic guidance system and the conventional method provided similarly accurate entry points for discography and consecutive PELD. However, the new stereotactic guidance system lowered the duration and radiation exposure for determining the entry point. Conclusions: The new stereotactic guidance system under fluoroscopy provided a reliable needle entry point for discography and consecutive PELD. Furthermore, it reduced the duration and radiation exposure associated with determining needle entry.

Use of Lidocaine Patch for Percutaneous Endoscopic Lumbar Discectomy

  • Kim, Kyung-Hoon
    • The Korean Journal of Pain
    • /
    • v.24 no.2
    • /
    • pp.74-80
    • /
    • 2011
  • Background: Lidocaine patch (L5P) has demonstrated short-term efficacy in treating both acute surgical pain and chronic neuropathic pain with tolerable side effects. Percutaneous endoscopic lumbar discectomy (PELD) is the mainstay of minimally invasive spine surgery (MISS). Sufficient analgesia during PELD surgery makes the patient consider it real MISS. This study was performed to evaluate the efficacy and adverse effects of lidocaine patch in patients who underwent PELD under local anesthesia. Methods: L5P (L group) or placebo (P group) was randomly applied on the skin of the back covering the anticipated path of the working channel before 1 hour of surgery in 100 patients who underwent a single level PELD at L4-L5. Efficacy of the lidocaine patch was assessed by patient's numeric rating scale (NRS) of pain at each stage during the surgery and by a 5-scale grading of the satisfaction with the anesthesia of the operator and patients after surgery. Results: Mean NRS scores at the stages of needle insertion, skin incision, serial dilation and insertion of working channel, and subcutaneous suture were significantly lower in the L group than the P group. Postoperative operator's and patients' satisfaction scores were also significantly higher in L group than in the P group. There were subtle adverse effects in both groups. Conclusions: L5P provided better pain relief during PELD, especially at the stage of needle insertion, skin incision, serial dilation and insertion of working channel, and subcutaneous suture. It also provided higher patient and operator postoperative satisfaction, with only subtle adverse effects.

A Study on Powder Electroluminescent Device through Structure and Thickness Variation (구조 및 두께 변화에 따른 후막 전계 발광소자에 관한 연구)

  • 오주열;정병선;이종찬;박대희
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.9-11
    • /
    • 1998
  • A phenomenon of electroluminescent radiate as electric field applied in the phosphor, in this paper, we produced the Powder Electroluminescent Device(PELD) which was changing the structure and the thickness of phosphor and insulator for realization of the PELD with high brightness. We made PELD with structure that is WK-1(ITO film/Phosphor/Insulator/Electrode), WK-2(ITO film/Phosphor/Insulator/Electro de), WK-3(ITO film/Phosphor/Insulator/Electrode), WK-4(ITO film/Phosphor+Insulator/ Electrode). The property of the produced PELD are analyzed by measuring the spectrum which electrical and optical property, the brightness and the transferred charge density. In this result, the structure of WK-4 have good luminescence property than others, it's effective thickness is 60${\mu}{\textrm}{m}$. At 100V 400Hz, High brightness of 2700cd/m2 was performed.

  • PDF

Foraminoplastic Superior Vertebral Notch Approach with Reamers in Percutaneous Endoscopic Lumbar Discectomy : Technical Note and Clinical Outcome in Limited Indications of Percutaneous Endoscopic Lumbar Discectomy

  • Lee, Chul-Woo;Yoon, Kang-Jun;Ha, Sang-Soo;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.2
    • /
    • pp.172-181
    • /
    • 2016
  • To describe the details of the foraminoplastic superior vertebral notch approach (FSVNA) with reamers in percutaneous endoscopic lumbar discectomy (PELD) and to demonstrate the clinical outcomes in limited indications of PELD. Retrospective data were collected from 64 patients who underwent PELD with FSVNA from August 2012 to April 2014. Inclusion criteria were high grade migrated disc, high canal compromised disc, and disc protrusion combined with foraminal stenosis. The clinical outcomes were assessed using by the visual analogue scale (VAS), Oswestry Disability Index (ODI) and modified MacNab criteria. Complications related to the surgery were reviewed. The procedure used a unique approach, using the superior vertebral notch as the target and performing foraminoplasty with only reamers under C-arm control. The mean age of the 55 female and 32 male patients was 52.73 years. The mean F/U period was $12.2{\pm}4.2$ months. Preoperative VAS ($8.24{\pm}1.25$) and ODI ($67.8{\pm}15.4$) score improved significantly at the last follow-up (VAS, $1.93{\pm}1.78$; ODI, $17.14{\pm}15.7$). Based on the modified MacNab criteria, excellent or good results were obtained in 95.3% of the patients. Postoperative transient dysthesia (n=2) and reoperation (n=1) due to recurred disc were reported. PELD with FSVNA could be a good method for treating lumbar disc herniation. This procedure may offer safe and efficacious results, especially in the relatively limited indications for PELD.