• Title/Summary/Keyword: PDP(Plasma Display)

Search Result 684, Processing Time 0.023 seconds

The characteristics of AC-PDPs According to binary and ternary gas mixtures of He-Ne-Xe_

  • Lee, H.J.;Son, C.G.;Lee, S.B.;Han, Y.K.;Jeoung, S.H.;You, N.L.;Lim, J.E.;Lee, J.H.;Moon, M.W.;Oh, P.Y.;Jeoung, J.M.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1195-1198
    • /
    • 2005
  • The improvement of efficiency is the one of the most important part in AC PDPs . To achieve high efficiency, high VUV emission efficiency and High ion induces secondary electron emission coefficient are needed. We have measured the emission spectra of vacuum ultraviolet rays and ion induced secondary electron emission coefficient of MgO protective layer in surface discharge AC-PDP with binary and ternary gas mixtures. We have investigated electro-optical characteristics of AC-PDPs to optimum gas mixture for high efficient.

  • PDF

Discharge Properties of an AC-Plasma Display Panel

  • Sungkyoo Lim
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 1998
  • Two kinds of the ac-plasma display panel (PDP) with the comb type and the matrix type electrodes were fabricated. The discharge properties were studied as a function of as species (Ne and Ne+He+Xe) and its pressure. The firing voltages (Vf) of the PDP with comb type electrodes were 159 V and 195 V under pure Ne and ne+He+Xe(68:30:2) gas mixture respectively. In case of PDP cell with the matrix type electrodes the Vf was increased to 200 V for pure Ne and 240 V for Ne+He+Xe gas mixture under the same gas pressure(300 mbar).

Discharge Characteristics of a Plasma Display using Vertical Auxiliary Electrodes

  • Moon, Cheol-Hee
    • Journal of Information Display
    • /
    • v.9 no.1
    • /
    • pp.20-25
    • /
    • 2008
  • In a conventional plasma display, the bus electrode was located on the ITO electrode at the outer part of each cell. We propose a new electrode configuration using vertical auxiliary electrodes which play a role of electrically connecting ITO and bus electrodes with the aim of enhancing discharge and luminous characteristics of the PDP (Plasma Display Panel). In this paper, luminance and luminous efficiency of the 3 in.-diagonal test panel are measured with various number of vertical auxiliary electrodes such as 2, 50 and 150. The change in the luminous characteristics is explained in connection with the discharge characteristics of the PDP cells such as current peak, IR emission peak and ICCD picture image.

Research and Development of High Performance 42-inch XGA Plasma Display Panel

  • Choi, Kwang-Yeol;Min, Byoung-Kuk;Kim, Tae-Hyung;Song, Byung-Soo;Yoo, Eun-Ho;Kim, Jin-Young;Jung, Yun-Kwon;Kim, Won-Tae;Yang, Hee-Chan;Ryu, Jae-Hwa
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.231-235
    • /
    • 2004
  • High performance 42 inch XGA PDP with high luminance of 1,000 cd/$m^2$ has been developed using high efficient electrode structure, discharge gas and closed barrier ribs. For high speed addressing with single scan technique, address discharge time lag was reduced over 40% with FAST driving scheme and new materials. High dark room contrast ratio of 5,000 : 1 was achieved and picture quality was improved using new algorithm for eliminating false contour and improving gray level linearity.

  • PDF

Improvement of Color Temperature using Auxiliary Address Pulse Driving Scheme in 42-in. WVGA Plasma Display Panel

  • Park, Ki-Hyung;Lee, Eun-Cheol;Cho, Ki-Duck;Tae, Heung-Sik;Chien, Sung-Il
    • Journal of Information Display
    • /
    • v.6 no.1
    • /
    • pp.22-27
    • /
    • 2005
  • Auxiliary address pulse driving scheme is proposed for controlling and improving the color temperature of the 42-inch WVGA ac-plasma display panel (ac-PDP) without sacrificing total luminance. Under a white-background, the color temperature of 42-inch ac-PDP is improved by about 1,700 K, whereas under a black-background, the color temperature of 42-inch ac-PDP is improved by about 3,200 K. In addition, by properly controlling the luminance in the R, G, and B cells, the color temperature of 42-inch ac-PDP can be raised from 5,827K to 10,705K.

New Shaped Electrodes to Reduce Addressing Time in a Large AC Plasma Display Panel

  • Lee, Sung-Hyun;Kim, Dong-Hyun;Park, Chung-Hoo;Jang, Yun-Seok;Ryu, Jae-Hwa
    • Journal of Information Display
    • /
    • v.2 no.1
    • /
    • pp.10-13
    • /
    • 2001
  • The addressing time can be reduced by modifying cell structure and/or driving circuits in order to replace the dual scan system by single scan in large ac plasma display panel(PDP). Moreover, the luminance of the PDP can also be increased by decreasing the addressing time. In this paper, various shapes of bus and address electrodes have been investigated with the aim of reducing the addressing time in ADS driving method. The experimental results show that the addressing time can be reduced by more than 30% compared with the conventional type by modifying the electrodes without reducing the luminance of the PDP.

  • PDF

Influence of sintering temperature of MgO pellet on the electro-optical characteristics of alternating current plasma display panel (AC-PDP)

  • Hong, Sung-Hee;Son, Chang-Gil;Jung, Seok;Kim, Jung-Seok;Paik, Jong-Hoo;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.400-403
    • /
    • 2008
  • We have investigated the electro-optical characteristics of AC-PDP with different MgO protective layers, which have been deposited by electron beam evaporation from various sintered pellets with different temperatures. We have measured the secondary electron emission coefficient ($\gamma$) by using the Gamma Focused Ion Beam ($\gamma$-FIB) system, the static margin, and the address delay time. Also, we have investigated photoluminescence (PL) characteristics for understanding the energy levels of MgO pellets and protective layers.

  • PDF

PDP 개발동향

  • 박원택;최기섭
    • 전기의세계
    • /
    • v.38 no.10
    • /
    • pp.40-44
    • /
    • 1989
  • PDP(Plasma display Panel)는 Gas 방전을 하여 발생하는 빛을 이용하여 화상 표시를 하는 flat panel display이다. PDP는 용도는 여러가지가 있지만 현재 주용도는 Computer Monitor이다. 아직 Orange색 이외의 표시색상은 개발되어 있지 않다. Computer Monitor용의 단색 PDP개발은 최근에 활발히 진행되었다. 16 계조표시가 가능한 10inch 640 * 400 Dot PDP가 DIXY, Matsushita, Oki를 비롯한 여러 회사에서 개발되어 상품화 되었다. 국내에서는 금성사, 대우, 삼성에서 현재 개발을 진행시키고 있고 최근에 삼성에서 Computer Monitor용의 640 * 400 Dot PDP가 개발되었다. 그러나 단색 PDP의 생산 시설 과잉으로 최근에는 일본의 DIXY가 도산하였다. 현재는 단색 PDP로 시장 개척에 한계를 느낀 PDP제조 업체에서 총력을 쏟아 CPT(Color Picture Tube) 대체를 위하여 Full Color PDP를 개발하고 있다.

  • PDF

Electron Temperature, Plasma Density and Luminous Efficiency in accordance with Discharge Time in coplanar AC PDPs

  • Jeong, S.H.;Moon, M.W.;Oh, P.Y.;Jeong, J.M.;Ko, B.D.;Park, W.B.;Lee, J.H.;Lim, J.E.;Lee, H.J.;Han, Y.G.;Son, C.G.;Lee, S.B.;Yoo, N.L.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1203-1206
    • /
    • 2005
  • Electron temperature and plasma density in coplanar alternating-current plasma display panels (AC-PDP's) have been experimentally investigated in accordance with discharge time by a micro-probe in this experiment. The resolution of a step mortor to move in micro-Langmuir probe is 10um.[1-3] The used gas in this experiment is He-Ne-Xe (4%) mixure gas. And sustain voltage is 320V which is above of firing voltage for degradation. The electron temperature and plasma density can be obtained from current-voltage (I-V) characteristics of micro Langmuir probe, in which negative to positive bias voltage was applied to the probe. And Efficiency is calculated by formula related discharge power and light emission. Those experiments operated as various discharge time ($0{\sim}72$ Hours). As a result of this experiment, Electron Temperature was increased from 2eV to 5eV after discharge running time of 20 hours and saturates beyond 20 hours. The plasma density is inversely proportional to the square root of electron temperature. So the plasma density was decreased from $1.8{\times}10^{12}cm^{-3}$ to $8{\times}10^{11}cm^{-3}$ at above discharge running time. And the Efficiency was reduced to 70% at 60hours of discharge running time.

  • PDF