• 제목/요약/키워드: PD pulse

검색결과 158건 처리시간 0.022초

Partial Discharge Signal Denoising using Adaptive Translation Invariant Wavelet Transform-Online Measurement

  • Maheswari, R.V.;Subburaj, P.;Vigneshwaran, B.;Iruthayarajan, M. Willjuice
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.695-706
    • /
    • 2014
  • Partial discharge (PD) measurements have emerged as a dominant investigative tool for condition monitoring of insulation in high voltage equipment. But the major problem behind them the PD signal is severely polluted by several noises like White noise, Random noise, Discrete Spectral Interferences (DSI) and the challenge lies with removing these noise from the onsite PD data effectively which leads to preserving the signal for feature extraction. Accordingly the paper is mainly classified into two parts. In first part the PD signal is artificially simulated and mixed with white noise. In second part the PD is measured then it is subjected to the proposed denoising techniques namely Translation Invariant Wavelet Transform (TIWT). The proposed TIWT method remains the edge of the original signal efficiently. Additionally TIWT based denoising is used to suppress Pseudo Gibbs phenomenon. In this paper an attempt has been made to review the methodology of denoising the PD signals and shows that the proposed denoising method results are better when compared to other wavelet-based approaches like Fast Fourier Transform (FFT), Discrete Wavelet Transform (DWT), by evaluating five different parameters like, Signal to noise ratio, Cross-correlation coefficient, Pulse amplitude distortion, Mean square error, Reduction in noise level.

공간회로망법을 이용한 GIS내부의 펄스 전파특성 해석 (Analysis of Pulse Propagation Characteristics in GIS Using Spatial Network Method)

  • 고영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권1호
    • /
    • pp.30-36
    • /
    • 2001
  • In this paper, propagation and damping characteristics of PD pulse in GIS are analyzed using SNM. These characteristics are very important to make a diagnosis and protection of accident in GIS. SNM is numerical method in time domain and very useful method to analyze 3-Dimensional structure such as GIS. GIS modeling is made simply as the form of coaxial cable and then spacers are inserted in it. The scattering and reflection in the GIS are appeared and damping characteristics of PD pulse are shown. When simulation using SNM compare to measurement, two results are similar.

  • PDF

센서에 따른 부분방전 펄스 분석 및 노이즈 제거 기법에 대한 연구 (A Study on the PD Pulse Analysis and Noise Discrimination Method according to various sensors)

  • 김정태;이욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1469-1471
    • /
    • 2006
  • It is very important to discriminate noises such as air corona in measuring on-site partial discharges (PD). Therefore, in order to investigate the possibility of separating PD(partial discharge) and noises through the pulse analysis, pulse shapes measured by a resistive sensor and a HFCT were analyzed and PA(pulse analysis) were performed. For the purpose, the HFPD detection and PA system has been developed. Also void discharges and air corona were adopted as the artificial defect and noises, respectively.

  • PDF

GIS 진단시스템의 평가를 위한 PD 모의 펄스발생기 개발에 관한 연구 (A Study on the Development of PD Simulation Pulse Generator for Evaluation of GIS Diagnosis System)

  • 김성주;장석훈;조국희
    • 한국안전학회지
    • /
    • 제33권2호
    • /
    • pp.21-27
    • /
    • 2018
  • The expansion and stable operation of electric power facilities are important factors with development of industrial facilities in modern society. In high-voltage equipment such as GIS, the insulation characteristics may be deterioated by environment-friendly gas adaption and miniaturization. There is also the possibility of accidents due to insulation breakdown due to the deterioration of power facilities. Therefore, it is necessary to extend the diagnosis system to continuously monitor the danger signals of these power equipment and to prevent accidents. Most of the internal defects in the GIS system are conductive particles, floating electrode defects, protrusion defects, and the like. In this case, a partial discharge phenomenon is accompanied. These partial discharge signals occur irregularly and various noise signals are included in the field, so it is difficult to evaluate the reliability in the development of the diagnostic system. In this paper, a study was made on equipment capable of generating a partial discharge simulated signal that can be adjusted in size and frequency to be applied to a diagnostic device by electromagnetic wave detection method. The PD simulated pulse generator consists of a user interface module, a high-voltage charging module, a pulse forming circuit, a voltage sensor and an embedded controller. In order to simulate the partial discharge phenomenon similar to the actual GIS, a discharge cell was designed and fabricated. The application of the prototype pulse generator to the commercialized PD diagnosis module confirmed that it can be used to evaluate the performance of the diagnostic device. It can be used for the development of GIS diagnosis system and performance verification for reliability evaluation.

A study on consistency and accuracy of pulse diagnosis in Eight-Constitution Medicine

  • Shin, Yong-Sup;Nah, Seong-Su;Oh, Hwan-Sup;Park, Young-Jae;Park, Young-Bae
    • Advances in Traditional Medicine
    • /
    • 제9권1호
    • /
    • pp.14-19
    • /
    • 2009
  • The aim of this study is to evaluate appraiser's consistency and accuracy about pulse diagnosis (PD) in discrimination of eight-constitutions using Gage R&R study. Cumulative numbers of PD for discrimination of eight constitutions of three appraisers' experience were 75,000 cases, 50,000 cases, 1,100 cases, respectively. Three Appraisers diagnosed subject's eight-constitutions by PD with blinded method. Gage R&R study was used to verify the results. In the measurements of consistency, appraiser B (agreement = 80%, Value of k = 0.8276) was very good, appraiser A (agreement = 70%, Value of k = 0.7465) was good, and appraiser C (agreement = 50%, Value of k = 0.5365) was moderate. In the measurements of accuracy, appraiser B (agreement = 70%, Value of k = 0.6812) was good, appraiser A (agreement = 60%, Value of k = 0.6414) was good, and appraiser C (agreement = 0%, Value of k = -0.1000) was poor. The results suggest that accuracy of discrimination of constitutions relatively depend on experience and number of cases of PD. Further large controlled study is needed to evaluate the accuracy of PD.

초음파 측정에 의한 변압기내 부분방전 위치측정 (Location of Partial Discharge in Oil Transformer by means of Ultrasonic measurement)

  • 곽희로;전희종;김재철;황선주;윤용한;권태원;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.415-418
    • /
    • 1991
  • This paper described an instrument for the detection and geometric location of partial discharge(PD) sources in oil transformer. This instrument measures electric current pulse and ultrasonic pulse simultaneously in order to determine the geometric location of PD in transformer. Laboratory experiment systems are made for detection and location of PD in oil transformer. It was observed that there are effects of the barrier, such as insulation papers, silicon steel plate and actual transformer with location and detection of PD in model transformer. Through the laboratory actual test, it was clarified that this measurement device could be used satisfactorily for location of pd in oil transformer.

  • PDF

STFT 및 통계적 처리에 의한 공기 중 부분방전원 식별 (Recognition of PD Sources in Air by STFT and Stochastic Parameters)

  • 이강원;박성희;강성화;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제17권1호
    • /
    • pp.101-106
    • /
    • 2004
  • The phenomenon of PD(Partial Discharge) is accompanied by electromagnetic wave which can be detected by UHF(Ultra High Frequency) antenna. The signals obtaining from UHF antenna are very high rapid pulse and have wide band frequency responses. The distribution of PRPD(Phase Resolved Partial Discharge) which consisted of those pulse train can show distinct characteristics of PD sources. But it is not sufficient to discriminate among PD sources. This paper suggests that the stochastic parameters formed by preprocessing of STFT(Short Time Fourier Transform) are good tools for differentiate from PD sources. The stochastic parameters are CC(Cross Correlation) mean value, CC standard deviation, CC skewness, CC kurtosis.

광섬유 센서를 이용한 부분방전 측정연구 (A Study on Partial Discharge Measurement using Optical Fiber Sensors)

  • 이준호;이철규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.922-924
    • /
    • 1998
  • In this paper, an optical fiber sensor(OF sensor) utilizing the principal of Mach-Zehnder interferometer were proposed to detect the partial discharge signals in insulating oil. At first the AC breakdown signals were detected to check the response of the OF sensor. The detected signals from OF sensor was consistent with that from current probe. After the response checking, simultaneous measurements and continuous recording were made of electrical and the OF sensor signals from partial discharge(PD) produced by IEC(b) electrode system immersed in insulating oil. The continuous recording made it possible to extract basic quantities of PD from the OF sensor signals, such as pulse phase and pulse amplitude distribution. Through the signal analysis, the absolute peaks of the OF sensor PD signal was found to be increased with the amplitude of electrical signals, and these results mean that there is a strong correlation between OF sensor and electrical PD signals. It was demonstrated that the OF sensor in this research had a possibility to detect the PD signals in power apparatus.

  • PDF

펄스 분석 기법 및 데이터 마이닝 기법을 이용한 부분방전 패턴인식에 대한 연구 (A Study on the PD Pattern Recognition using the Pulse Analysis Method and Data Mining Methods)

  • 김정태;이욱;김지홍;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1535-1537
    • /
    • 2006
  • Recently, the noise discrimination method using PD pulse waveshape analysis has been suggested to be very effective method which can improve the reliability of the on-site PD measurement. In this method, the data clusters due to PD pulses or noises can be distinguished on the PA map. And for the automatic recognition of the PD clusters, it is necessary to adopt the adaptable pattern recognition method. In this study, as for the algorithm which can recognize data clusters, the data mining method has been adopted and the result of the analysis has been reported.

  • PDF

Partial Discharge Simulation and Analysis Based on Experiment in Underground Distribution Power Cables

  • Jung, Chae-Kyun;Kim, Jeong-Tae;Lee, Jong-Beom
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.832-839
    • /
    • 2013
  • This paper describes the simulation and experiment for partial discharge (PD) pulse propagation in 22.9kV CNCV power cables. To investigate the propagation characteristics of PD, experiments are carried out by injecting the PD pulse in 100m-long 60 $mm^2$ CNCV cable in the laboratory. The characteristics of PD are also simulated using EMTP to investigate and analyze PD in the same cable. By comparing the simulation and test results, parameter permittivity is recalculated by considering semiconducting screen in the process of simulation and analysis of PD. After it is proved that simulation results and test results are almost similar in the laboratory, extensive simulations are performed to analyse various PD characteristics such as propagation velocity, attenuation, etc. in 60 $mm^2$ and 325 $mm^2$ CNCV cables. Authors are confident that results obtained in this paper will be used as important technical materials to detect and investigate PD generated in transmission and distribution power cables.