• 제목/요약/키워드: PD monitoring

검색결과 131건 처리시간 0.03초

가스절연개폐기에서 용량성 전압프로브를 이용한 부분방전의 측정 (Partial Discharge Measurement by a Capacitive Voltage Probe in a Gas Insulated Switch)

  • 길경석;박대원;최수연;김일권;박찬용
    • 한국전기전자재료학회논문지
    • /
    • 제21권1호
    • /
    • pp.85-89
    • /
    • 2008
  • An objective of this paper is to develop a partial discharge (PD) measurement device for monitoring gas insulated switches installed in power distribution system. A capacitive voltage probe was studied and designed to detect PD pulse without an electrical connection. The PD measurement device consists of the capacitive voltage probe attached outside of a bushing, a coupling network which attenuates AC voltage by 270 dB, and a low noise amplifier with the gain of 40 dB in ranges of 500 kHz${\sim}$20 MHz. The sensitivity of the prototype device calculated by a calibrator was 1.98 m V /pc. An application experiment was carried out in a 25.8 kV gas insulated switch and the peak pulse of 76.7 pC was detected. From the experimental results, it is expected that the PD measurement device can be applied to online monitoring system of gas insulated switches.

UHF 부분방전 감시 장치를 위한 초광대역 검출장치 개발 및 특성조사 (Development and characterization of a ultra-wide bandwidth video detector for the UHF partial discharge monitoring system)

  • 박기준;구선근;윤진열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1649-1651
    • /
    • 2002
  • Ultra-wide bandwidth (UWB) detection method has been widely used as a front end detection scheme for the ultra-high frequency (UHF) partial discharge (PD) monitoring systems. A broad-band video detector module was developed and characterized for the UHF UWB PD detection systems. The useable bandwidth of the module is more than 2 GHz and it is optimized for 50-ohm systems. The detection sensitivity and dynamic range of the module were characterized by using a known ns-width RF pulses of GHz range. The dynamic range is more than 6-decades and the module can detect pulsed RF signals down to 1 nW. The detector module can eliminate expensive equipment such as high speed oscilloscopes and radio frequency (RF) spectrum analyzers. Therefore, it enables one to use slow speed data acquisition systems for the PD monitoring at the UHF range. The detector module was used to detect real PDs of about <3 pC. The module converts the UWB PD signals into a low-bandwidth video signal with a high signal-to-noise ratio.

  • PDF

배전반 설비의 온라인 모니터링 및 진단의 동향 (Trend in Off-Line PD Monitoring with HVAC Testing)

  • 윤주효;홍창일;황종선;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.529-530
    • /
    • 2007
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

모노폴 안테나를 이용한 유중 부분방전의 검출 (Detection of Partial Discharges by a Monopole Antenna in Insulation Oil)

  • 박대원;이정윤;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제25권9호
    • /
    • pp.727-731
    • /
    • 2012
  • This paper dealt with the measurement and analysis of electromagnetic waves radiated from a partial discharge (PD) source in insulation oil to apply condition monitoring of oil-immersed transformers. Two types of narrow-band monopole antennas with the resonant frequency of a 500 MHz and a 1 GHz were designed and fabricated. Also, a needle-plane electrode system was manufactured to simulate PDs and the curvature radius of the needle is 10 ${\mu}m$ and the diameter of the plane is 60 mm. Electromagnetic wave was measured by the PD measurement system with the monopole antennas. Detection sensitivity of the fabricated antenna was compared for the same PD magnitude; 620 $mV_{peak}$ for the 500 MHz antenna and 960 $mV_{peak}$ for the 1 GHz antenna to the PD magnitude of 74 pC. Consequently, the 1 GHz monopole antenna is more effective to detect PDs in oil-immersed transformers.

13[kV]급 수력발전기 고정자 권선의 운전 및 정지 중 진단시험 현장적용 평가 및 분석 (Site Evaluation and Application of the On-line and Off-line Test for the 13[kV] Class Hydropower Generator Stator Windings)

  • 장정호;이동근;이흥호
    • 조명전기설비학회논문지
    • /
    • 제25권11호
    • /
    • pp.73-82
    • /
    • 2011
  • The solid insulation system of stator windings in high voltage rotational machines is usually aging in accordance with long time operation. The partial discharge test have been known to check whether insulation deterioration exist or not, and the PD test can effectively diagnose a solid insulation condition regardless of during operation(on-line) or not(off-line). The on-line PD measurement have proven to be a successful technique in monitoring stator insulation condition nowadays. This paper describes the characteristics of comparing the on-line PD measurement data using PDMS-HG(Partial Discharge Monitoring System for Hydro-electric Generator) installed in field with the off-line diagnosis measurement data(insulation resistance, winding resistance, PI, ${\Delta}tan{\delta}$ and PD) on hydro generator(13[kV]) stator windings. These results make good use of managing rotational machines through evaluating the solid insulation condition of stator windings.

분포형 광음향센싱 기반 부분방전 모니터링 기술 연구 (Partial Discharge Monitoring Technology based on Distributed Acoustic Sensing)

  • 김희운;이주영;정효영;김영호;김명진
    • 센서학회지
    • /
    • 제31권6호
    • /
    • pp.441-447
    • /
    • 2022
  • This study describes a novel method for detecting and measuring partial discharge (PD) on an electrical facility such as an insulated power cable or switchgear using fiber optic sensing technology, and a distributed acoustic sensing (DAS) system. This method has distinct advantages over traditional PD sensing techniques based on an electrical method, including immunity to electromagnetic interference (EMI), long range detection, simultaneous detection for multiple points, and exact location. In this study, we present a DAS system for PD detection with performance evaluation and experimental results in a simulated environment. The results show that the system can be applied to PD detection.

DC 변전소 몰드변압기 온라인 상태 감시 시스템 구현 (Implementation of a Condition Monitoring System for Mold Transformers in DC Substations)

  • 박영;정호성;박철민;장순호
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1788-1794
    • /
    • 2011
  • The mold transformer is a complex and critical component of DC substations in Metro system. In this paper, a cost effective and intelligent condition monitoring system for mold transformers in DC substations was developed. This paper also provides an overview of the management program using PD (partial discharge) data on mold transformers. Prior to application of the proposed system to Metro DC substations, experiments were performed at the metro line substation located in Seoul and presented case studies for the use of the intelligent condition monitoring system for mold transformer in DC substations. The experiment results indicated that the developing system can be need in helping mange the risk of unexpected failure of mold type transformers.

파킨슨병의 건강검진 및 일상 모니터링, 관리 기술의 특허 동향 분석 (Analysis of Patent Trends for Examination, Monitoring, and Healthcare of Parkinson's Disease)

  • 김근호;서정우;김지원
    • 대한한방내과학회지
    • /
    • 제41권6호
    • /
    • pp.1141-1161
    • /
    • 2020
  • Objectives: Parkinson's disease (PD) is a neurodegenerative disease of the elderly characterized by impaired behavior from lack of dopamine secretion. However, no accurate quantitative diagnosis method has been established. The purpose of this study was to analyze the patent trends (PTs) of health examination and daily monitoring/healthcare technology for PD. Methods: For analyzing PTs, a search summary for classifying each analysis target technology was set, and a final search formula was constructed by collecting keywords. After constructing a database of related patents through the final search formula, noise was removed to extract valid patents. PTs by major countries were analyzed using the valid patents, and PTs and growth stages were analyzed by the detailed technologies. Results: The survey analysis showed that, despite the existence of unpublished patents between 2018 and 2020, patent activity has increased rapidly in the recent period, and this increasing trend was led by the USA. This technology is considered to be in its early- or mid-stage growth period, which means that the marketability is high and the barriers are low. Korea's market share is only about 25%, but it has a larger number of applications than those of Europe and Japan. Integrated monitoring and diagnosis technologies for PD have a share of 34%. Conclusion: The advances in diagnosis and healthcare technology for PD means that traditional Korean medicine must continue to pay attention to related technologies and to review plans that are applicable to clinical practice.

온라인 부분방전 감시 시스템 (On-Line System for Partial Monitoring Discharge)

  • 최용성;황종선;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2114-2115
    • /
    • 2008
  • We consider the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers is described.

  • PDF

발전기 고정자 권선 절연상태의 상시 감시 시스템 개발 (Development of Continuous Monitoring System for Generator Stator Insulations)

  • 신병철;황돈하;김용주;김정우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2212-2214
    • /
    • 1999
  • In this paper, a novel Generator On-line Diagnosis System (GODS) is proposed. This system monitors the insulation condition of the stator winding by on-line measurements of partial discharge (PD). Sensor, such as SSC (Stator Slot Coupler) and RFCT (Radio Frequency Current Transformer) are used for PD measurement. PD signals are continuously measured and digitized with a high speed A/D converter to build the database of the generator's insulation condition. Also this system can communicate with the central monitoring system via RS-485. This helps more efficient operation and maintenance of the generator.

  • PDF