• Title/Summary/Keyword: PD monitoring

Search Result 131, Processing Time 0.025 seconds

Fabrication and Characteristics of Pd/Pt Gate MISFET Sensor for Dissolved Hydrogen in Oil (유중 용존수소 감지를 위한 Pd/Pt Gate MISFET 센서의 제조와 그 특성)

  • Baek, Tae-Sung;Lee, Jae-Gon;Choin, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.41-46
    • /
    • 1996
  • The Pd/Pt gate MISFET type hydrogen sensors, for detecting dissolved hydrogen gas in the transformer oil, were fabricated and their characteristics were investigated. These sensors including diffused resister heater and temperature monitoring diode were fabricated on the same chip by a conventional silicon process technique. The differential pair plays a role in minimizing the intrinsic voltage drift of the MISFET. To avoid the drift of the sensors induced by the hydrogen, the gate insulators of both FETs were constructed with double layers of silicon dioxide and silicon nitride. In order to eliminate the blister formation on the surface of the hydrogen sensing gate metal, Pt and Pd double metal layers were deposited on the gate insulator. The hydrogen response of the Pd/Pt gate MISFET suggests that the proposed sensor can detect the dissolved hydrogen in transformer oil with 40mV/10ppm of sensitivity and 0.14mV/day of stability.

  • PDF

Recent research and technical trend of power cable system (전력 케이블의 최근 연구 및 기술 동향)

  • Kim, Dong-Uk;Choe, Myeong-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.616-618
    • /
    • 2000
  • This paper describes the recent research and technical trend of power cable system. Compact sizing with long length and large capacity is the main trend of the power cable. From the manufacturing process to the monitoring of the underground power line, various new techniques are being developed for reliability and high quality such as in-line monitoring system, triple common extrusion, PD measurement system, new type completion test, etc.

  • PDF

The development of Ultra-High Frequency(UHF) sensor for Partial Discharge monitoring in Gas Insulated Switchgears (GIS내 부분방전 검출을 위한 광대역 UHF 센서 개발)

  • Kim, Young-Ro;Choi, Jae-Ok;Lee, Young-Sang;Kim, Jae-Chul;Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1975-1978
    • /
    • 2004
  • We developed internal and external type sensor to measure ultra-high frequency (UHF) partial discharge (PD) in 170 kV gas-insulated switchgears (GIS). We also manufactured a PD-generator to verify and measure the detection sensitivity of those sensors. We measured the output power of the UHF PD sensors induced by PDs of 5 pC using the PD-generator. We measured UHF propagation loss of an 170 kV GIS for optimal arrangement of the sensors. We used swept UHF signal from a network analyzer into the GIS to measure the loss of various components of the GIS.

  • PDF

The development of ultra-high frequency ultra-wide bandwidth sensor for Partial Discharge monitoring in Gas Insulated Switchgears (GIS 부분방전 검출용 극초단파 초광대역 센서 개발)

  • Kim, Young-Ro;Choi, Jae-Ok;Lee, Young-Sang;Kang, Chang-Won;Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.113-116
    • /
    • 2004
  • We developed internal and external type sensor to measure ultra-high frequency (UHF) partial discharge (PD) in 170 kV gas-insulated switchgears (GIS). We also manufactured a PD-generator to verify and measure the detection sensitivity of those sensors. We measured the output power of the UHF PD sensors induced by PDs of 5 pC using the PD-generator. We measured UHF propagation loss of an 170 kV GIS for optimal arrangement of the sensors. We used swept UHF signal from a network analyzer into the GIS to measure the loss of various components of the GIS.

  • PDF

Partial Discharge Monitoring for $SF_6$ Insulated MV Switchgear using UHF sensors (UHF Sensor를 이용한 SF6 절연 MV 개폐기의 부분방전 검출 시스템)

  • Lee, Do-Hoon;Kang, Won-Jong;Shin, Yang-Sop;Kim, Young-Geun;Oh, Il-Sung;Kim, Dong-Myung;Kwon, Tae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2040-2041
    • /
    • 2007
  • In this paper, the UHF PD(Partial Discharge) sensors for $SF_6$ insulated MV $SF_6$ switchgear have been proposed and related investigations have been performed in order to detect the PD which were produced inside the MV $SF_6$ switchgear. Firstly, the internal type UHF PD sensor based on spiral antenna theory has been developed. This type sensor is highly sensitive and has lowly effect on by on-site noise. Secondly, the external type UHF PD sensor was developed based on log periodic antenna concept. This type sensor is removable and detectable for operating switchgear. These sensors were designed and simulated using RF simulation tool. In order to verify the sensitivity of these sensors, we performed the on-site test using the mock-up switchgears including the artificial defects which were the protrusion on high voltage conductor, free moving metal particle and surface defect on insulator. These mock-up switchgear were installed on the test distribution line.

  • PDF

Feature Extraction of Partial Discharge for Stator Winding of High Voltage Motor (고압전동기 고정자권선의 부분방전 특징추출)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.7 no.4
    • /
    • pp.61-69
    • /
    • 2004
  • On-line monitoring of fault discharge is an important approach for indicating the condition of electrical insulation of stator winding in high voltage motor. In this paper, several key aspects of on-line monitoring system are discussed, involving the characteristics of fault discharge of stator winding in high voltage motor, spectrum analysis of four simulation fault signals, feature extraction of internal fault discharge from apply voltage to breakdown. The study of the partial discharge activities allows to highlight the ageing stage in the winding fault under test. During the life of the winding insulation fault, the shape of PD signal change relating to the ageing stage. The ageing of stator winding insulation fault of high voltage motor is investigated based on the characteristics of partial discharge pulse distribution and statistical parameters, such as maximum, skewness and kurtosis using discrete wavelet trnasform coefficients.

  • PDF

A Sensitive, Efficient, and Cost-Effective Method to Determine Rotigotine in Rat Plasma Using Liquid-Liquid Extraction (LLE) and LC-MRM

  • Kim, Ji Seong;Jang, Yong Jin;Kim, Jin Hee;Kim, Jin Hwan;Seo, Jae Hee;Park, Il-Ho;Kang, Myung Joo;Choi, Yong Seok
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.146-151
    • /
    • 2022
  • Rotigotine (RTG) is a non-ergot dopamine agonist used to manage the early stage of Parkinson's disease (PD) as transdermal patch. However, the poor medication compliance of PD patients and skin issues related with repeated applications of RTG patches lead to the search for alternative formulations and it also requires appropriate analytical methods for their in vivo evaluation. Thus, here, a sensitive, efficient, and cost-effective method to determine RTG in rat plasma using liquid-liquid extraction (LLE) and multiple reaction monitoring was developed. The use of 20 µL of rat plasma for sample treatment, 8-OH-DPAT as the internal standard, and methyl tert-butyl ether as the LLE solvent in the present method gives it advantages over previous methods for the analysis of RTG in biological samples. The good analytical performance of the developed method was confirmed in specificity, linearity (the coefficient of determination ≥0.999 within 0.1-100 ng/mL), sensitivity (the lower limit of quantitation at 0.1 ng/mL), accuracy (81.00-115.05%), precision (≤10.75%), and recovery (81.00-104.48%) by following the FDA guidelines. Finally, the applicability test of the validated method to the in vivo evaluation of a RTG formulation showed that the present method is the only method which can be accurately applied to that longer than 24 hours, critical for the development of formulations with reduced dosing frequencies. Therefore, the present method could contribute to the development of new RTG formulations helpful to people suffering from PD.

Compatibility of DOAS and Conventional Point Monitoring System Through an Evaluation of Bias Structures Using Long-term Measurement Data in Seoul (장기관측자료를 이용한 DOAS와 점측정 분석시스템의 바이어스 구조에 대한 평가)

  • 김기현;김민영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.5
    • /
    • pp.395-405
    • /
    • 2001
  • To make an assessment of the compatibility between DOAS and conventional point monitoring system (MCSAM-2: MS2), we investigated the concentrations of three criteria pollutants which include S $O_2$, N $O_2$, and $O_3$from a national monitoring station in Seoul during the periods of June 1999~August 2000. The average concentration values for the whole study period derived from hourly concentration data sets of those three species indicated that the mean differences between the two methods can be approximated as 18%. When the bias structure of two systems was evaluated through the computation of percent difference(PD) between the two such as ( $C_{DOAS}$- $C_{conventional}$ $C_{DOAS}$*100, differences between the two systems appeared to be quite systematic among different compounds. While the mode of bias peaked at 0~20% or 20~40% in terms of PD values, the cause of such positive bias mainly arised from generally enhanced concentration values of DOAS system. The structure of bias among different species was further assessed through linear regression analysis. Results of the analysis indicated that the dominant portions of differences observed from two monitoring systems can be accounted for by the systematic differences in their spanning and zeroing systems. S $O_2$(MS2)=0.6385 S $O_2$(DOAS)+2.0985($r^2$=0.7894) N $O_2$(MS2)=0.6548 N $O_2$(DOAS)+7.437($r^2$=0.7687) $O_3$(MS2)=1.0359 $O_3$(DOAS)-7.7885($r^2$=0.7944) The findings of slope values at around 0.64~0.65 from two species suggest that DOAS should respond more sensitively in upper bound concentration range. The offset values apart from zero indicate that more deliberate comparison needs to be made between these monitoring systems. However, based on the existence of strong correlations from at least 8,000 data points for each species of comparison, we were able to conclude that the compatibility of two monitoring systems is highly significant. With the improvement of calibration techniques for the DOAS system. its applicability for routine monitoring of airborne pollutant species is expected to be quite extendable.

  • PDF

STN DBS of Advanced Parkinson's Disease Experienced in a Specialized Monitoring Unit with a Prospective Protocol

  • Lee, Ji-Yeoun;Han, Jung-Ho;Kim, Han-Joon;Jeon, Beom-Seok;Kim, Dong-Gyu;Paek, Sun-Ha
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.1
    • /
    • pp.26-35
    • /
    • 2008
  • Objective : In the evaluation of patients with Parkinson's disease (PD), most neurologists only see their patients during a limited period of their fluctuating 24-hour-a-day lives. This study aimed to assess the short-term outcome of STN stimulation for patients with advanced PD evaluated in a 24-hour monitoring unit for movement disorder (MUMD) using a prospective protocol. Methods : Forty-two patients with advanced PD consecutively treated with bilateral STN stimulation using multi-channel microelectrode recording were included in this study. All patients were evaluated using a 24-hour MUMD with a video recording/editing system and were evaluated with a prospective protocol of the Unified Parkinson's Disease Rating Scale, Hoehn and Yahr Staging, Schwab and England Activities of Daily Living, levodopa equivalent daily dose (LEDD), Short Form-36 Health Survey, and neuropsychological tests. Magnetic resonance (MR) images of the brain were performed prior to and six months after surgery. Results : All patients were evaluated at three and six months after surgery. There was a rapid and significant improvement of the motor symptoms, especially in tremor and rigidity, after STN stimulation with low morbidity. Dyskinesia was markedly decreased with much lowered LEDD values by 50% after STN stimulation. 1.5T MR images were safely taken according to the manufacturer's guidelines at six months after surgery without any adverse effects in 41 patients treated with STN stimulations. Conclusion : Evaluations in a 24-hour monitoring unit could reduce the dose of medication efficiently to an optimal level with patients' comfort and improve the clinical symptoms in harmony with STN stimulation.

Design of Fuzzy PD Depth Controller for an AUV

  • Loc, Mai Ba;Choi, Hyeung-Sik;Kim, Joon-Young;Kim, Yong-Hwan;Murakami, Ri-Ichi
    • International Journal of Ocean System Engineering
    • /
    • v.3 no.1
    • /
    • pp.16-21
    • /
    • 2013
  • This paper presents a design of fuzzy PD depth controller for the autonomous underwater vehicle entitled KAUV-1. The vehicle is shaped like a torpedo with light weight and small size and used for marine exploration and monitoring. The KAUV-1 has a unique ducted propeller located at aft end with yawing actuation acting as a rudder. For depth control, the KAUV-1 uses a mass shifter mechanism to change its center of gravity, consequently, can control pitch angle and depth of the vehicle. A design of classical PD depth controller for the KAUV-1 was presented and analyzed. However, it has inherent drawback of gains, which is their values are fixed. Meanwhile, in different operation modes, vehicle dynamics might have different effects on the behavior of the vehicle. In this reason, control gains need to be appropriately changed according to vehicle operating states for better performance. This paper presents a self-tuning gain for depth controller using the fuzzy logic method which is based on the classical PD controller. The self-tuning gains are outputs of fuzzy logic blocks. The performance of the self-tuning gain controller is simulated using Matlab/Simulink and is compared with that of the classical PD controller.