• 제목/요약/키워드: PD measurement system

검색결과 116건 처리시간 0.032초

전력케이블의 절연결함에 따른 부분방전 특성분석 (Analysis of PD Characteristics by Types of Insulation Defects in Power Cables)

  • 최재성;박찬용;김선재;한주섭;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1977-1983
    • /
    • 2009
  • This paper described partial discharge(PD) patterns depending on types of insulation defects in CNCO-W cable(Concentric Neutral Closs-linked Polyethylene Insulated Polyolefin-Water Proof Sheathed Power Cable). The PD measurement system consists of a coupling network, a detection impedance, and a low noise amplifier. A 16 bit, 250 MS/s data acquisition system was used to analyze PD patterns. To simulate insulation defects in a power cable, a needle with the curvature radius of $10{\mu}m$ was inserted into the insulation part. We measured phase ($\Phi$), magnitude (q), and counts (n) of PD pulse for the defects, and classified PD patterns using the PRPD (phase Resolved Partial Discharge) method. From the analysis of acquired PD signals, we could find that a unique PD pattern is formed according to the types of defect.

  • PDF

부분방전전류측정을 위한 로고스키코일의 적용에 관한 연구 (Study about the Application of Rogowski Coil for measuring Partial Discharge Current)

  • 이강원;윤성철;김명룡;백광선;나동희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1378-1383
    • /
    • 2004
  • Rogowski coil is a kind of sensor for high amplitude and very short period current and suitable for the measurement of PD pulse. This paper have simulated the relations between PD signals and Rogowski coil which has its own equivalent circuit and investigated signals of Rogowski coil induced by PD pulse current. and compared with the PD signal obtained from conventional PD measuring system in accordance with IEC60270.

  • PDF

HFPD 검출법을 이용한 지중 케이블 실선로 진단 (Diagnosis of power cable system based on the HFPD detection at on-site)

  • 이전선;김충식;이동근;공충호;석광현;이경욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.97-100
    • /
    • 2004
  • HFPD(High Frequency Partial Discharge) measurement has been widely performed to diagnosis of cable system in the world although Korea just begin. The efficiency of measurement has been reported and proved by many researchers who are engaged in the diagnosis of high power apparatus. LG Cable has investigated the technology of diagnosis for cable system by means of PD measurement for 10 years. In this paper, PD measurement with portable device was performed to evaluate the quality of the 154kV transmission line and the 22.9kV XLPE cable line. Test results are shown that the HFPD detection technology is very attractive for the diagnosis of power cable system by high detection sensitivity at on-site.

  • PDF

충격파-부분방전(SI-PD) 시험방법을 이용한 케이블 진단에 관한 기초 연구 (A Possible diagnostic method of cable system using SI-PD measurement)

  • 김정태;구자윤;장은;조연옥;김상준;송일근;김주용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1774-1777
    • /
    • 1996
  • In this paper, applicability of SI-PD(switching impulse - partial discharge) testing method was put on an attempt as a newly proposed diagnostic method for the underground distribution power cable system in Korea. For this purpose, SI-PD testing equipment was designed, and tests were performed using artificial needle-type defects integrated into the 22.9 kV CN/CV cables in drder to prove its reliability. As a result, arc noises, generated from spark gap, were considerably decreased by use of a pneumatic switch immersed into oil, and artificial needle-type defects were well detected with impulse voltage level under $2U_0$. These results imply that it is likely possible to apply SI-PD measurement method as a the nondistructive test for the 22.9 kV CN/CV cable system in Korea.

  • PDF

대용량 터빈 발전기에 사용되는 온라인 부분방전 관측 시스템에 관한 연구 (The Study on a PD On-line Monitoring System Used for Large Turbine Generators)

  • 오광영;강대용;박대희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권1호
    • /
    • pp.45-50
    • /
    • 1999
  • This paper describes a partial discharge (PD) on-line monitoring system used for large turbine generators. The system consists of a broadband current transducer, a computer-aid PD measurement system. By using a programmable fabricate band pass filter and an adaptive digital filter, the system can suppress the noise and extract PD signal from the intense noise surroundings successfully. Two simulated PD sources, which often exist in the large generators, were simulated and detected. At the end of this paper, some field test results, obtained from a 200MW generating set, were presented and discussed.

  • PDF

3d-PD 패턴과 VHF/UHF PD 신호의 고찰 (The Analysis of VHF/UHF PD and 3d-PD Pattern)

  • 임장섭;박용석;최병하;한석균
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 반도체재료
    • /
    • pp.75-78
    • /
    • 2001
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

PD 측정을 이용한 배전용 EPDM애자의 성능평가 (Estimation of EPDM Insulator in Distribution Line Using PD Measurement)

  • 송일근;임장섭;이형구;천종욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.319-322
    • /
    • 1998
  • Many researchers make efforts to develop an effective material with anti-degradation property. Specially, the porcelain type insulator is required exchanging to polymer insulator acceding to the environmental consideration In this paper, we have developed the estimation system using the PD testing. The approach of PD has been very successful applied to the various practical insulator.

  • PDF

모노폴 안테나를 이용한 유중 부분방전의 검출 (Detection of Partial Discharges by a Monopole Antenna in Insulation Oil)

  • 박대원;이정윤;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제25권9호
    • /
    • pp.727-731
    • /
    • 2012
  • This paper dealt with the measurement and analysis of electromagnetic waves radiated from a partial discharge (PD) source in insulation oil to apply condition monitoring of oil-immersed transformers. Two types of narrow-band monopole antennas with the resonant frequency of a 500 MHz and a 1 GHz were designed and fabricated. Also, a needle-plane electrode system was manufactured to simulate PDs and the curvature radius of the needle is 10 ${\mu}m$ and the diameter of the plane is 60 mm. Electromagnetic wave was measured by the PD measurement system with the monopole antennas. Detection sensitivity of the fabricated antenna was compared for the same PD magnitude; 620 $mV_{peak}$ for the 500 MHz antenna and 960 $mV_{peak}$ for the 1 GHz antenna to the PD magnitude of 74 pC. Consequently, the 1 GHz monopole antenna is more effective to detect PDs in oil-immersed transformers.

부분방전 측정에 의한 하이브리드차량 견인전동기의 절연성능평가 (Evaluation on Insulation Performance of Traction Motors for a Hybrid Vehicle by Partial Discharge Measurement)

  • 박대원;박찬용;최재성;길경석;이강원
    • 한국철도학회논문집
    • /
    • 제12권2호
    • /
    • pp.249-253
    • /
    • 2009
  • 본 논문에서는 부분방전 측정에 의한 하이브리드 차량용 견인전동기의 절연평가에 대하여 기술하였다. 부분방전법은 효과적인 비파괴시험으로 저압용 전기전자기기의 절연성능평가에 사용되어 왔다. 부분방전 측정시스템은 결합회로망, 저잡음 증폭회로 및 주변 전자회로로 구성되며, 주변 잡음의 영향을 최소화하기 위하여 차폐함내에 설치하였다. 교정실험으로부터 부분방전 측정시스템의 주파수 대역은 $1[MHz]{\sim}30[MHz]$ (-3[dB]), 감도는 19[mV/pC]로 평가되었다. 기사용 전동기와 신품 전동기에서 방전개시전압(DIV)과 겉보기 전하량(q)을 측정한 결과, 기사용 전동기의 방전개시전압은 $1,100[V_{rms}]$, 겉보기 전하량은 105[pC], 신품 전동기에서의 방전개시전압은 $1,400[V_{rms}]$, 겉보기 전하량은 84[pC]이었다. 방전개시전압과 전하량을 비교함으로써 견인전동기의 절연상태를 평가할 수 있었다.

고압 전동기 고정자 권선의 절연진단을 위한 운전중 부분방전 측정 시스템 개발 (Development of On-Line Partial Discharge Measuring System for Insulation Diagnosis of High-Voltage Motor Stator Windings)

  • 황돈하;강동식;신병철;이영진;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.481-486
    • /
    • 2006
  • In this paper, a new on-line high-voltage motor monitoring system is proposed. This system monitors the insulation condition of the stator winding by on-line measurements of partial discharge (PD). And this system displays magnitude and phase angle distribution of PD. Sensor, CC (Ceramic Coupler) is used for PD measurement. PD signals are continuously measured and digitized with a A/D converter to build the database of the high-voltage motor's insulation condition. Also, this system can communicate with the central monitoring system via RS-232, 422, and TCP/IP. This helps more efficient operation and maintenance of the high-voltage motor.

  • PDF