• 제목/요약/키워드: PD measurement system

검색결과 116건 처리시간 0.029초

고압전동기 운전중 부분방전 감시 시스템 개발 (Development of On-Line Partial Discharge Monitoring System in High Voltage Motors)

  • 김희동;공태식;주영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1175-1178
    • /
    • 2004
  • On-line partial discharge(PD) monitoring system has been developed to monitor in operating large motor stator insulations. This system makes use of remote diagnosis techniques for the evaluation of PD activity in the control center of thermal power plant. This system can be remotely accessed via a modem to build database, analyze status and interpret the pattern of PD activity. A personnel computer is generally connected to ten motors to continuous measurement of the PD activity. The test data can be easily interpreted by a maintenance staff. For assessing the condition of stator winding in motors, this system ensures a reliable measurement and accurate estimation. Capacitive couplers used for on-line PD measurement have been 80pF. The maximum PD magnitude(Qmax), PD pattern and normalized quantity number(NQN) were performed by this system.

  • PDF

저압용 전기전자부품의 신뢰성 평가를 위한 부분방전 측정시스템에 관한 연구 (A Study on the PD Measurement System for Estimating Reliabilities of Low-voltage Electrical and Electronic Components)

  • 서황동;송재용;문승보;길경석;강동식;황돈하
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.321-322
    • /
    • 2005
  • In this paper, we dealt with a partial discharge(PD) measurement system that has been accepted as an effective and non-destructive technique for estimating reliabilities of low-voltage electrical and electronic components. Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 37.6 mv/pC. In an application test on photo coupler, we could detect 0.1 pC level of partial discharge at the applied voltage of AC 520 $V_{peak}$.

  • PDF

분포형 광음향센싱 기반 부분방전 모니터링 기술 연구 (Partial Discharge Monitoring Technology based on Distributed Acoustic Sensing)

  • 김희운;이주영;정효영;김영호;김명진
    • 센서학회지
    • /
    • 제31권6호
    • /
    • pp.441-447
    • /
    • 2022
  • This study describes a novel method for detecting and measuring partial discharge (PD) on an electrical facility such as an insulated power cable or switchgear using fiber optic sensing technology, and a distributed acoustic sensing (DAS) system. This method has distinct advantages over traditional PD sensing techniques based on an electrical method, including immunity to electromagnetic interference (EMI), long range detection, simultaneous detection for multiple points, and exact location. In this study, we present a DAS system for PD detection with performance evaluation and experimental results in a simulated environment. The results show that the system can be applied to PD detection.

극미소 부분방전 측정시스템의 설계 및 제작 (Design and Fabrication of an Ultra-low Partial Discharge Measurement System)

  • 서황동;송재용;문승보;길경석;권장우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.208-211
    • /
    • 2005
  • This paper presents an ultra-low partial discharge(PD) measurement system that has been accepted as a non-destructive method to estimate electrical insulation of low-voltage electric devices. The PD measurement system is composed of a coupling network, a low noise amplifier, and associated electronics. A shielding box is used to make a better condition against electromagnetic interference. A low cut-off frequency of the coupling network was 1MHz(-3 dB). Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 11.4mV/pC. In an application experiment on a low-voltage induction motor(5HP), we could detect 0.77pC level of partial discharge pulse at the applied voltage of AC 664 V$_{peak}$.

  • PDF

154kV XLPE 케이블 실선로 부분방전 검출 (Partial Discharge Measurement for 154kV XLPE Cable Line)

  • 김충식;이전선;김종철;박창기;석광현;김원년
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.23-25
    • /
    • 2004
  • HFPD(High Frequency Partial Discharge) measurement has been widely performed to diagnose cable system in the world. Shin-Yeongdeungpo 345kV XLPE line was successfully diagnosed by PD measurement methode last year. Moreover, aged power cable lines which were installed 15 years ago have been tested from this year. In this paper, the result of PD diagnosis for aged 154kV cable line is reported. The PD pattern from TMJ which was monitored by PD measurement system for several days showed typical void pattern. The joint was replaced and voids between semi-conductor layer and insulating layer in the joint was founded.

  • PDF

ERA 부분방전 측정시스템의 측정불확도개선 (Measurement uncertainty Improvement of ERA PD measuring system in teat laboratory)

  • 허종철;김위영;김석수;오창수;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1509-1510
    • /
    • 2006
  • ERA PD measuring system has been using for partial discharge evaluation of power appratus in test laboratories. So, the measurement uncertainty of PD measuring system (ERA), such as PD pulse calibrator rise and fall time, sacle factor(k) and linearity, transfer impedance etc, is very important factor of test result in test laboratory. In this paper, we describe tracebility and uncertainty improvement of PD measuring system in test laboratory based on IEC 60270.

  • PDF

전력케이블에서 교류전압과 진동파 전압을 이용한 부분방전 측정 (Partial Discharge Detection for the Power Cables using AC and Oscillating wave Voltage)

  • 김정태;김남준;이전선;구자윤
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권4호
    • /
    • pp.247-252
    • /
    • 1999
  • In this paper, in order to investigate availability of the OW-PD measurement method which has been proposed as an alternative of AC-PD measurement method to an after laying test and/or diagnosis for the power cable system, partial discharges owing to the needle-type defect integrated into the cable have been measured using AC and OW(Oscillating Wave) voltages. In the AC-PD measurement, the magnitude, phase and pulse number of partial discharges have been changed with the duration of voltage application, which can be analyzed through the relation with the process of the electrical tree initiation and propagation. In addition, the characteristics of partial discharges using OW voltage are appeared to be similar to those in case of AC-PD measurement and to be different with the shapes of electrical tree. From these results, it is concluded that the OW-PD measurement method is available to the tests for the cable system.

  • PDF

고체 합성수지절연체와 표면노화 진단기술로서의 부분방전 측정평가기술에 대하여 (Partialt Discharge Measurement Techniques for Diagnosis of Surface Aging on Organic Insulation)

  • 박완기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 춘계학술대회 논문집
    • /
    • pp.50-56
    • /
    • 1994
  • Partial discharge on organic insulation surfaces are an important sauce of aging. Furthermore the modern PD measurement technigues are rapid developed as quality control and diagnostic tests to determine the fitness for use of HV equipment employing sol id electrical insulation. This paper deals with theory of conventional PD measurement and new tendency of technical development on PD measurements und evaluations. Finally the Measuring system used for diagnosing the surface aging on the organic insulation at High Voltage Laboratory of Technical University of Darmstadt in Germany is presented.

  • PDF

부분방전 측정에 의한 저압용 유도전동기의 절연성능 평가 (Evaluation on Insulation Performance of Low-voltage Induction Motors by Partial Discharge Measurement)

  • 박대원;최수연;최재성;길경석;이강원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1887-1891
    • /
    • 2008
  • In this paper, we dealt with a partial discharge (PD) measurement method that has been accepted as an effective and non-destructive technique to estimate insulation performance of low-voltage induction motors. The PD measurement system consists of a coupling network, a low noise amplifier, and associated electronics. A shielded box was used to reduce environmental noise. Frequency characteristic of the coupling network was estimated by a sinusoidal signal input, and the low cut-off frequency of the coupling network was 1 MHz (-3 dB). Also, we carried out a calibration test for the PD measurement system. Sensitivity of the system was of 84 m$V_{max}$/pC between stator winding and enclosure. In application test on a low-voltage three phase induction motor (5 HP), we could detect 88 pC at AC 800 $V_{max}$.

  • PDF

안경 광학중심과 동공중심의 불일치에 의한 수평, 수직 유발프리즘의 측정 (Measurement of Horizontal and Vertical Prism Diopter According to Difference between the Optical Center and Pupil Center)

  • 김효진;박지현;박선아;백지선;이은희
    • 한국안광학회지
    • /
    • 제16권1호
    • /
    • pp.1-5
    • /
    • 2011
  • 목적: 본 연구는 조제 가공된 안경의 광학적 중심간 거리와 동공간거리의 일치여부를 알아보고, 안경의 광학적 중심높이와 OH의 일치여부를 분석하여 수평, 수직 차이에 의한 유발 프리즘을 검사하고자 하였다. 방법: 평균 나이21.56세의 96명(192안)을 대상으로 동공거리계(DONGYANG PD-85, Korea)로 동공간거리를 측정하였고, 안경의 광학적 중심간 거리는 투영식 정점 굴절력계(TOPCON CL-200, Japan)로 측정하였다. OH는 펜라이트와 PD자를 이용하여 측정하였다. 마지막으로 현재 착용하고 있는 안경의 착용기간을 조사하였다. 결과: 동공거리계로 측정한 동공간 거리와 투영식 정점 굴절력계로 측정한 안경렌즈의 광학적 중심간 거리는 78.1%(150안)에서 일치하지 않았고, 62.5%(60명)에서 기저내방으로 안경이 조제되었으며, 이 중 58.3%(56명)가 허용오차 범위 외에 있었다. 조제 가공된 안경과 피검사자의 OH를 비교한 결과 수직 유발 프리즘은 단 8명(8.3%)에서만이 유발되지 않았으며, 79명(82.3%)이 1 이상의 프리즘이 유발되었다. 조제후 7개월이 지난 경우에는 통계적인 차이는 없었으나 수직 OH의 차이가 더 컸다. 결론: 안경 착용자에게 양안 시기능을 보다 좋고 편안하게 향상시켜주기 위하여 PD와 OH 측정 및 조제에 더욱 정확성을 기울여야 할 것이다. 정확한 조제 및 가공과 함께 안경원의 정기방문 또한 필요할 것이다.