• Title/Summary/Keyword: PD measurement system

Search Result 116, Processing Time 0.021 seconds

A comparative analysis of volatile organic compound levels in field samples between different gas chromatographic approaches (분석기법의 차이에 따른 현장시료의 VOC 분석결과 비교연구: 분석오차의 발생 양상과 원인)

  • Ahn, Ji-Won;Pandey, Sudhir Kumar;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.465-476
    • /
    • 2010
  • In this study, a number of volatile organic compounds (VOCs) including benzene, toluene, p-xylene, styrene, and methyl ethyl ketone were analyzed from samples collected in ambient air and under the field conditions. These samples were analyzed independently by two different set-ups for VOC analyses, i.e., between [1] gas chromatography/flame ionization detector with tube sampling - (F-T system) and [2] gas chromatography/mass spectrometer with bag sampling (M-B system). The analytical results derived by both systems showed fairly similar patterns in relative sense but with moderately large differences in absolute sense. The results of M-B system were high relative to F-T system with the F-T/M-B ratio below 1. If the relative biases of the two measurement techniques are derived in terms of percent difference (PD) in concentration values, the results were generally above 35% on average. A student t-test was applied to investigate the statistical significance of those differences between the systems. The results of both analytical systems were different at 95% confidence level for toluene, p-xylene, styrene, and methyl ethyl ketone (P < 0.043). However, F-T and M-B systems showed strong correlations for toluene and p-xylene. The observed bias is explained in large part by such factors as the differences in standard phases used for each system and the chemical loss inside the bag sampler.

Compatibility of DOAS and Conventional Point Monitoring System Through an Evaluation of Bias Structures Using Long-term Measurement Data in Seoul (장기관측자료를 이용한 DOAS와 점측정 분석시스템의 바이어스 구조에 대한 평가)

  • 김기현;김민영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.5
    • /
    • pp.395-405
    • /
    • 2001
  • To make an assessment of the compatibility between DOAS and conventional point monitoring system (MCSAM-2: MS2), we investigated the concentrations of three criteria pollutants which include S $O_2$, N $O_2$, and $O_3$from a national monitoring station in Seoul during the periods of June 1999~August 2000. The average concentration values for the whole study period derived from hourly concentration data sets of those three species indicated that the mean differences between the two methods can be approximated as 18%. When the bias structure of two systems was evaluated through the computation of percent difference(PD) between the two such as ( $C_{DOAS}$- $C_{conventional}$ $C_{DOAS}$*100, differences between the two systems appeared to be quite systematic among different compounds. While the mode of bias peaked at 0~20% or 20~40% in terms of PD values, the cause of such positive bias mainly arised from generally enhanced concentration values of DOAS system. The structure of bias among different species was further assessed through linear regression analysis. Results of the analysis indicated that the dominant portions of differences observed from two monitoring systems can be accounted for by the systematic differences in their spanning and zeroing systems. S $O_2$(MS2)=0.6385 S $O_2$(DOAS)+2.0985($r^2$=0.7894) N $O_2$(MS2)=0.6548 N $O_2$(DOAS)+7.437($r^2$=0.7687) $O_3$(MS2)=1.0359 $O_3$(DOAS)-7.7885($r^2$=0.7944) The findings of slope values at around 0.64~0.65 from two species suggest that DOAS should respond more sensitively in upper bound concentration range. The offset values apart from zero indicate that more deliberate comparison needs to be made between these monitoring systems. However, based on the existence of strong correlations from at least 8,000 data points for each species of comparison, we were able to conclude that the compatibility of two monitoring systems is highly significant. With the improvement of calibration techniques for the DOAS system. its applicability for routine monitoring of airborne pollutant species is expected to be quite extendable.

  • PDF

Calculation and measurement of optical coupling coefficient for bi-directional tancceiver module (양방향 송수신모듈 제작을 위한 광결합계수의 계산 및 측정)

  • Kim, J. D.;Choi, J. S.;Lee, S. H.;Cho, H. S.;Kim, J. S.;Kang, S. G.;Lee, H. T.;Hwang, N.;Joo, G. C.;Song, M. K.
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.500-506
    • /
    • 1999
  • We designed and fabricated a bidirectional optical transceiver module for low cost access network. An integrated chip forming a pin-PD on an 1.3 urn FP-LD was assembled by flip-chip bonding on a Si optical bench, a single mode fiber with an angled end facet was aligned passively with the integrated chip on V-groove of Si-optical bench. Gaussian beam theory was applied to evaluate the coupling coefficients as a function of some parameters such as alignment distance, angle of fiber end facet, vertical alignment error. The theory is also used to search the bottle-neck between transmittance and receiving coupling efficiency in the bi-directional optical system. Tn this paper, we confirmed that reduction of coupling efficiency by the vertical alignment error between laser beam and fiber core axis can be compensated by controlling the fiber facet angle. In the fabrication of sub-module, a'||'&'||' we made such that the fiber facet have a corn shape with an angled facet only core part, the reflection of transmitted laser beam from the fiber facet could be minimized below -35 dE in alignment distance of 2: 30 /J.m. In the same condition, transmitted output power of -12.1 dEm and responsivity of 0.2. AIW were obtained.

  • PDF

Performance Improvement of Epoxy Resin System by the Filler Reformation (충진제 개질을 통한 에폭시복합체의 성능개선)

  • Yi, Dong-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.130-135
    • /
    • 2010
  • In this study, the performance improvement of epoxy resin system had been tried by the improvement of particle size distribution and globularization of filler using polymerization method. From the results of particle size distribution measurement, the polydispersity value of reformed filler was 1.04 and that of silica flour before reformation was 2.6, it could be confirmed that the particle size uniformity of reformed filler had been improved greatly and the shape of particle was globular. Compatibility between monomer and silica was improved remarkably with the silanization pretreatment of silica flour. From the results of degree of crosslinking test, it could be confirmed that the binding structure of reformed filler was 3-dimensional net structure. And it could be also confirmed that the fluidness was improved at the casting of epoxy resin with reformed filler. From the above results, it could be concluded that the reformation of filler with the improvement of particle size distribution and globularization was very successful method to improve the performance of cast epoxy resin system.

FMCW Radar simulation model with interference using a new radar performance parameter (새로운 레이더 성능지표를 이용한 FMCW 레이더 간섭 시뮬레이션 모델)

  • Mun, Sang-Kon;Park, Seung-Keun;Yang, Hoon-Gee;Cheon, Chang-Yul;Chung, Young-Seek;Bae, Kyung-Bin
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.4
    • /
    • pp.86-92
    • /
    • 2011
  • ITS(Intelligent Transport System) has been researched actively to guarantee the smooth traffic and the safety of the vehicle. In recent, as the sensor for the measurement of distance between vehicles, the FMCW radar system in millimeter wave band has been interested in ITS. Actually, 47, 60, 77, 94 and 139 GHz have been assigned for the vehicle radar frequencies in Europe and Japan. However, the performances of the FMCW radar are deteriorated due to the interferences from the surrounding radars and mobile devices. In this paper, in order to model and simulate the performance of FMCW radar under the exterior interference, we propose a new performance parameter, RER(Radius Error Rate), which contains the information of the range error due to the interferences, and show the effectiveness of the proposed parameter.

Design and Implementation of FMCW Radar Signal Processor for Drone Altitude Measurement (드론 고도 측정용 FMCW 레이다 신호처리 프로세서 설계 및 구현)

  • Lim, Euibeen;Jin, Sora;Jung, Yongchul;Jung, Yunho
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.6
    • /
    • pp.554-560
    • /
    • 2017
  • Accurate altimetry is required for the reliable flight control of drones or unmanned air vehicles (UAVs), and the radar altimeter is commonly used owing to its accuracy for the ground level. Due to the limitation for size, weight and power consumption, the frequency modulated continuous wave (FMCW) radar is appropriate for drone because it has lower complexity than that of pulse Doppler (PD) radar. Especially, fast-ramp FMCW radar, which transmits linear FM signal during very short period, is generally utilized, because it is robust for the ego-motion of drone. Therefore, we present the design and implementation results of the radar signal processor (RSP) for fast-ramp FMCW radar system. The proposed RSP was designed with Verilog-HDL and implemented with Altera Cyclone-IV FPGA device. Implementation results show that the proposed RSP includes 27,523 logic elements, 15,798 registers and memory of 138Kbits and can measure the altimeter at the rate of 100Hz with the operating frequency of 50MHz.