• 제목/요약/키워드: PCXMC Program

검색결과 14건 처리시간 0.018초

전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가 (Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography)

  • 김정진;장성원;박장흠;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

소아 X선 촬영조건 변화에 따른 소아 및 촬영보조자 선량 (Doses of Pediatric and X-ray Examination Assistants according to Changes in Pediatric X-ray Exposure Conditions)

  • 장범진;남하윤;신혜민;윤동민;이승국;장인화;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권5호
    • /
    • pp.409-415
    • /
    • 2023
  • Although pediatric X-ray examinations are continuously increasing, there are not many studies on the radiation exposure to children and X-ray examination assistants according to X-ray Exposure conditions. Accordingly, we measured the radiation exposure dose of pediatric and X-ray examination assistants according to the standard guidelines and clinical average X-ray Exposure conditions when X-ray examination 10-year-old children. The effective dose and organ dose to pediatric were measured using an Dose area production meter and Monte Carlo-based PCXMC program, and the exposure dose of X-ray examination assistants was measured using an ion-chamber. When performing abdominal supine AP projection, the effective dose to children was up to 2.38 times higher under clinical average X-ray Exposure conditions than the standard guidelines. In addition, during abdominal supine AP projection, the radiation exposure dose to the X-ray examination assistants was highest on the hands at 0.0148 ~ 0.0709 mSv, and exposure dose could be reduced by up to 35% when wearing protective gloves. In conclusion, because the X-ray Exposure conditions used in clinical are unnecessarily high, unnecessary medical radiation exposure could be reduced if appropriate X-ray Exposure conditions and the radiation field area were minimized and the assistant wore shielding gloves.

자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향 (Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control)

  • 이강민
    • 한국방사선학회논문지
    • /
    • 제18권3호
    • /
    • pp.257-265
    • /
    • 2024
  • 본 연구는 자동노출제어 흉부 방사선 검사 시 신체 기능 일부를 대체 보조하거나 의약품 등을 주입하는 인체 이식형 의료기기가 흉부 영상의 선량과 화질에 영향을 미치는지 알아보고자 하였다. 제조회사와 모델이 다른 3대의 디지털 X선 발생장치와 인체모형 팬텀을 사용하여 흉부 검사와 동일한 방법으로 위치잡이를 선정 후 선행 연구에서 선량의 변화가 관찰된 인공심장박동기(Pacemaker), 심장 재동기화 치료기(CRT), 케모포트(Chemoport) 3개의 HIMD(Human Implantable Medical Device)를 상단 이온전리조센서에 부착한 후 Monte Carlo 방법론 기반의 프로그램 PCXMC 2.0을 사용하여 실험에서 도출된 DAP(Dose Area Product) 값을 입력하여 유효선량을 측정하였다. 또한 흉부 영상의 화질 평가를 하기 위해 가슴 부위에 관심 영역 3곳과 잡음영역 1곳을 설정하고 신호대잡음비(SNR; Signal to Noise Ratio), 대조도대잡음비(CNR; Contrast to Noise Ratio)를 측정하였다. 연구 결과는 유효선량의 유의미한 차이를 보여주었으며 AEC 적용과 미적용 그룹을 비교하였을 때 Pacemaker와 CRT는 유의한 차이가 있었다. (p<0.05) AEC 적용 시 Pacemaker에서 37%, CRT에서 52% 유효선량이 증가하였다. Chemoport는 유효선량의 10% 차이는 있었지만, 유의미한 차이를 보이지 않았다. (p>0.05) 영상 품질 평가에서는 모든 HIMD 삽입과 AEC 적용 유무에 따른 SNR, CNR의 유의미한 차이를 보이지 않았다. (p>0.05) 최종 결론은 AEC 적용 후 HIMD가 삽입된 환자의 흉부 X-ray 검사 시 유효선량이 증가하였으며 AEC 적용 유무에 따른 흉부 영상의 품질 차이는 없음을 알 수 있었다. 이는 HIMD가 삽입된 환자의 흉부 검사 시 AEC 미사용이 환자의 선량을 낮추는 타당성을 확인한 것이며 과피폭을 주의하고 피폭 저감화를 위한 다양한 방법을 모색하여야 한다.

관상동맥조영술과 경피적관상동맥중재술에서 환자 선량과 암 발생 생애귀속위험 평가 (Radiation Dose and Estimate of Lifetime Attributable Risk of Cancer from Coronary Angiography and Percutaneous Coronary Intervention)

  • 강영한;김부순;박종삼
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권3호
    • /
    • pp.213-221
    • /
    • 2010
  • 관상동맥질환의 진단과 치료를 위한 관상동맥조영술(Coronary Angiography, CA)과 경피적관상동맥중재술(Percutaneous Coronary Intervention, PCI) 과정에서 환자에 대한 유효선량을 알아보고, 이 선량으로 인한 암 발생위험을 CA와 PCI를 구분하여 평가해 보고자 하였다. CA를 시행한 환자 60명과 PCI 시술을 받은 환자 58명을 대상으로 DAP(dose-area product)를 측정하였고, 몬테카를로 시뮬레이션(Monte Carlo simulations) 프로그램(PCXMC 1.5)을 이용하여 유효선량과 장기선량을 산출하였다. 암 발생의 생애귀속위험의 평가는 전리방사선 생물학적 효과 위원회의 7차 보고서(BEIR VII)를 활용하였다. 그 결과 대상자의 DAP 값 평균은 CA군에서 $53.76\;Gy{\cdot}cm^2$이었고, PCI군에서는 $165.82\;Gy{\cdot}cm^2$이었다. 유효선량은 CA군에서 평균 1.28 mSv이었고, PCI군에서는 3.94 mSv이었다. 장기선량은 폐에서 CA군 2.17 mSv, PCI군 6.71 mSv이었고, 여성 유방선량은 CA에서 5.45 mSv, PCI에서 16.82 mSv이었다. 암 발생 생애귀속위험은 CA에서 남성은 1,508명 중 1명, 여성은 1,357명 중 1명이었고, PCI에서는 남성 553 중 1명, 여성은 482명 중 1명이었다. DAP 값은 몬테 카를로 시뮬레이션을 기본으로 하여 장기선량과 유효선량을 계산할 수 있는 지표가 되었다. CA와 PCI 과정에서 환자에게 노출되는 방사선량은 무시할 수 없는 암 발생의 생애귀속위험이 된다. 또한 암 발생 위험은 PCI군에서 더 높았고, 남성보다는 여성이 더 높았다.