• Title/Summary/Keyword: PCS Systems

Search Result 316, Processing Time 0.036 seconds

Development of PCS for Doubly-fed Induction-type Wind Turbine (이중여자 유도형 풍력발전기 제어를 위한 PCS 개발)

  • Jeong, Byoung-Chang;Chung, Yong-Ho;Kim, Sung-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1182-1183
    • /
    • 2008
  • In this paper, we develop PCS for doubly-fed induction-type wind generator(DFIG). PCS consists of a converter set and a controller. PCS controls the active power of wind generator and the reactive power of wind turbine system according to rotating speed, instantaneous power, grid quality, and order by transmission system operator.

  • PDF

Modified Multi-Chaotic Systems that are Based on Pixel Shuffle for Image Encryption

  • Verma, Om Prakash;Nizam, Munazza;Ahmad, Musheer
    • Journal of Information Processing Systems
    • /
    • v.9 no.2
    • /
    • pp.271-286
    • /
    • 2013
  • Recently, a pixel-chaotic-shuffling (PCS) method has been proposed by Huang et al. for encrypting color images using multiple chaotic systems like the Henon, the Lorenz, the Chua, and the Rossler systems. All of which have great encryption performance. The authors claimed that their pixel-chaotic-shuffle (PCS) encryption method has high confidential security. However, the security analysis of the PCS method against the chosen-plaintext attack (CPA) and known-plaintext attack (KPA) performed by Solak et al. successfully breaks the PCS encryption scheme without knowing the secret key. In this paper we present an improved shuffling pattern for the plaintext image bits to make the cryptosystem proposed by Huang et al. resistant to chosen-plaintext attack and known-plaintext attack. The modifications in the existing PCS encryption method are proposed to improve its security performance against the potential attacks described above. The Number of Pixel Change Rate (NPCR), Unified Average Changed Intensity (UACI), information entropy, and correlation coefficient analysis are performed to evaluate the statistical performance of the modified PCS method. The simulation analysis reveals that the modified PCS method has better statistical features and is more resistant to attacks than Huang et al.'s PCS method.

Experimental Test for Seismic Performance of PCS Structural System (PCS 구조 시스템의 내진 성능 분석)

  • Park, Soon-Kyu;Yeo, In-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.313-322
    • /
    • 2007
  • The PCS system, which consists of precast concrete column and steel beam, is a kind of composite structural systems. In this paper, experimental study has been conducted to analyze seismic performance of bolted beam-to-column connections for the PCS system. Based on experimental results from the seismic testing of eight interior PCS specimens, it shows that behavior of PCS system is satisfactory to seismic performance criteria of ACI such as strength deterioration, stiffness degradation and energy dissipation capacity except initial stiffness. All of the specimens maintain their strength at large levels of story drift without significant loss of stiffness and show high ductility level for inelastic behavior. The energy dissipation capacity is two times greater than requirement of ACI criterion. But the initial stiffness of all specimens does not satisfy ACI criterion, and this phenomenon is similar to the other composite structural systems such as RCS, CFT system.

A Security Analysis of a Key Management Scheme for PCS/SCADA Sensor Networks (PCS/SCADA 센서 네트워크용 키 관리 프로토콜에 대한 보안 분석)

  • Park, DongGook
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.2
    • /
    • pp.123-131
    • /
    • 2009
  • Process Control Systems (PCSs) or Supervisory Control and Data Acquisition (SCADA) systems have recently been added to the already wide collection of wireless sensor networks applications. The PCS/SCADA environment is somewhat more amenable to the use of heavy cryptographic mechanisms such as public key cryptography than other sensor application environments. The sensor nodes in the environment, however, are still open to devastating attacks such as node capture, which makes designing a secure key management challenging. Recently, Nilsson et al. proposed a key management scheme for PCS/SCADA, which was claimed to provide forward and backward secrecies. In this paper, we define four different types of adversaries or attackers in wireless sensor network environments in order to facilitate the evaluation of protocol strength. We then analyze Nilsson et al. 's protocol and show that it does not provide forward and backward secrecies against any type of adversary model.

Design of a Module for Oscillation Detection in an Integrated PCS and W-CDMA Receiver

  • Park Joung-Geun;Lee Jong-Chul
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.4 no.1 s.6
    • /
    • pp.73-79
    • /
    • 2005
  • In this paper, a circuit for detecting a fine oscillation in an integrated PCS and W-CDMA receiver is presented. The advantages for this design are small size and flexible compatibility for system operation compared with the conventional method. The fine oscillation level can be detected by dB unit through selecting the receiver mode as PCS of 1.8 GHz range or W CDMA of 1.9 GHz range by a RF switch and monitoring the corresponding frequency band. Also, the circuit is designed to be flexible for other communication systems with the consideration of the required dynamic range of 75 dB.

  • PDF

PCS Research and Development in Shinsegi Telecomm. Inc. (신세기통신의 PCS 연구개발현황)

  • 박용길;정동근;이도영
    • Information and Communications Magazine
    • /
    • v.12 no.8
    • /
    • pp.53-64
    • /
    • 1995
  • In this article, criteria and considerations for selecting a domestic Personal Communications Services (PCS) system in Korea are presented and upbanded IS-95 Common Air Interface (CAI) is asserted to be appropriate as a result of evaluation by the criteria. And Shinsegi Telecomm, Inc. (STI) is claimed to be a suitable operator to provide PCS by upbanded IS-95 considering the experiences as the cellular operator adopting IS-95 CDMA technology. The PCS R&D plan and strategies of STI are given and the joint R&D plan with domestic manufacturers to develop PCS systems are explained. The results from R&D so far are mentioned. The PCS network architecture and various services-basic voice service, value-added services and wireless data services-are discussed.

  • PDF

The commercialization of ESS PCS replacing Emergency Generator (비상발전용 ESS(Energy Storage System) 상용화 개발)

  • Park, Minjun;Seo, Jungwon;Hwang, Kwangkyu;Park, Juhyun;Jang, Jeahoon;Kim, Heejung
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.461-462
    • /
    • 2016
  • 본 논문은 100kW 급 비상발전용 ESS 상용화 개발을 제안한다. 비상발전기란 전력계통이 정지되었을 때 발전장치를 구동시켜 전력을 생산하는 자가발전설비를 말한다. 제안하는 시스템은 2Level 전압형 100kW 급 비상발전용 ESS 로써 정상 시 계통 전원과 동기 운전을 수행하는 계통 연계형 전력변환장치이다. 수배전 수용가에 설치되어 운영이 가능하며 일반적인 ESS PCS 기능인 주파수 조정 (Frequency Regulation), 출력 안정화, 첨두부하 저감 (Peak Shaving), 부하평준화 (Load Leveling), 수요반응 (Demand Response)에 추가하여, 자가발전 (Black Start), 무효전력제어 등의 기능을 적용 하였다. 제안된 100kW 급 비상발전기용 ESS PCS 는 시뮬레이션 및 프로토 타입을 이용하여 성능을 검증하였다.

  • PDF

A Study of ANPC Topology using SiC FET for Improving Efficiency of ESS PCS (ESS PCS 효율 향상을 위한 SiC 기반 ANPC Topology에 대한 연구)

  • Hwang, Kwang-kyu;Lee, Seung-woon;Kim, Ho-yeol;Ahn, Sung-guk;Kim, Hee-jung;Kim, Young-geun
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.309-310
    • /
    • 2019
  • 현재 화석연료 고갈과 미세 먼지 등의 환경 문제는 전 세계적인 이슈가 되어가고 있으며, 이에 따라 태양광, 풍력 등 신재생 에너지 사용 및 설치가 늘어나고 있다. 반면에, 다양한 분산 전원의 증가로 인해, 계통 불안정 문제 역시 전면에 대두되고 있으며, ESS등 계통 보조 시스템에 대한 관심과 실제 설치는 점점 선택이 아닌 필수적 조건으로 자리잡고 있다. 시장의 확대에 따라, 해당 시스템의 신뢰성과 효율에 대한 관심 역시 증가되고 있으며, 최대한의 성능을 위해 태양광 및 ESS등의 전압은 LV(Low Voltage)의 한계점인 1500V를 달성하였고, 이에 따라 ESS와 PCS역시 해당 전압에서의 동작 및 효율적인 동작 및 설치를 위해 발전하고 있다. 본 논문에서는 이러한 상황에 맞춰 효율적인 PCS 개발을 위한 방안을 제안하도록 한다.

  • PDF

A Strategy for Developing a Platform-based PCS (Platform 기반의 PCS 개발전략)

  • Joe, Injoon;Kang, Hohyun;Koh, Kwangsoo;Kim, Heejung;Kim, Younggeun
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.435-436
    • /
    • 2019
  • 본 논문은 Platform 기반의 PEBB(Power Electronics Building Block)을 이용한 계통연계형 에너지저장시스템(ESS) PCS의 개발전략과 효율적인 운용 방법에 대해 제안한다. Platform Design이란 표준제조 공정을 통해 다양한 제품을 만들어 내는 기술을 뜻한다. 이 Platform으로 생산되는 Modular PEBB(Power Electronics Building Block)을 이용하여 다양한 용량대의 제품에 대응할 수 있으며, 이를 통해 125kW에서부터 2MW제품까지 병렬확장이 가능하다. PCS의 Platform화로 시스템 용량 확장이 용이하며, 대량 생산이 가능하기 때문에 비용 측면에서의 장점이 있다. 그리고 부분 운전을 통해 운영 효율 향상과 PCS 수명을 늘릴 수 있다. 본 논문에서는 Platform 기반의 PCS의 물리적 및 제어적 구조를 설명하고, 개발전략의 방법에 대해 소개하고자 한다.

  • PDF

Detection of Zombie PCs Based on Email Spam Analysis

  • Jeong, Hyun-Cheol;Kim, Huy-Kang;Lee, Sang-Jin;Kim, Eun-Jin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.5
    • /
    • pp.1445-1462
    • /
    • 2012
  • While botnets are used for various malicious activities, it is well known that they are widely used for email spam. Though the spam filtering systems currently in use block IPs that send email spam, simply blocking the IPs of zombie PCs participating in a botnet is not enough to prevent the spamming activities of the botnet because these IPs can easily be changed or manipulated. This IP blocking is also insufficient to prevent crimes other than spamming, as the botnet can be simultaneously used for multiple purposes. For this reason, we propose a system that detects botnets and zombie PCs based on email spam analysis. This study introduces the concept of "group pollution level" - the degree to which a certain spam group is suspected of being a botnet - and "IP pollution level" - the degree to which a certain IP in the spam group is suspected of being a zombie PC. Such concepts are applied in our system that detects botnets and zombie PCs by grouping spam mails based on the URL links or attachments contained, and by assessing the pollution level of each group and each IP address. For empirical testing, we used email spam data collected in an "email spam trap system" - Korea's national spam collection system. Our proposed system detected 203 botnets and 18,283 zombie PCs in a day and these zombie PCs sent about 70% of all the spam messages in our analysis. This shows the effectiveness of detecting zombie PCs by email spam analysis, and the possibility of a dramatic reduction in email spam by taking countermeasure against these botnets and zombie PCs.