• Title/Summary/Keyword: PCR detection kit

Search Result 104, Processing Time 0.027 seconds

Effective DNA extraction method to improve detection of Mycobacterium avium subsp. paratuberculosis in bovine feces

  • Park, Hong-Tae;Shin, Min-Kyoung;Sung, Kyung Yong;Park, Hyun-Eui;Cho, Yong-Il;Yoo, Han Sang
    • Korean Journal of Veterinary Research
    • /
    • v.54 no.1
    • /
    • pp.55-57
    • /
    • 2014
  • Paratuberculosis caused by Mycobacterium avium subsp. paratuberculosis (MAP) has extended latent periods of infection. Due to this property, difficulties in the detection of fecal shedder have been raised. A newly designed method for DNA extraction from fecal specimens, mGITC/SC was evaluated in terms of diagnostic efficiency. The detection limit of IS900 real-time PCR was about 50 MAP (1.5 cfu) in 250 mg of feces (6 cfu per g). Also, this DNA extraction method was faster and cheaper than that using commercial kit or other methods. Consequently, the mGITC/SC is an economical DNA extraction method that could be a useful tool for detecting MAP from fecal specimens.

Loop-Mediated Isothermal Amplification Targeting 18S Ribosomal DNA for Rapid Detection of Acanthamoeba

  • Yang, Hye-Won;Lee, Yu-Ran;Inoue, Noboru;Jha, Bijay Kumar;Sylvatrie Danne, Dinzouna-Boutamba;Kim, Hong-Kyun;Lee, Junhun;Goo, Youn-Kyoung;Kong, Hyun-Hee;Chung, Dong-Il;Hong, Yeonchul
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.3
    • /
    • pp.269-277
    • /
    • 2013
  • Amoebic keratitis (AK) caused by Acanthamoeba is one of the most serious corneal infections. AK is frequently misdiagnosed initially as viral, bacterial, or fungal keratitis, thus ensuring treatment delays. Accordingly, the early detection of Acanthamoeba would contribute significantly to disease management and selection of an appropriate anti-amoebic therapy. Recently, the loop-mediated isothermal amplification (LAMP) method has been applied to the clinical diagnosis of a range of infectious diseases. Here, we describe a rapid and efficient LAMP-based method targeting Acanthamoeba 18S rDNA gene for the detection of Acanthamoeba using clinical ocular specimens in the diagnosis of AK. Acanthamoeba LAMP assays detected 11 different strains including all AK-associated species. The copy number detection limit for a positive signal was 10 DNA copies of 18S rDNA per reaction. No cross-reactivity with the DNA of fungi or other protozoa was observed. The sensitivity of LAMP assay was higher than those of Nelson primer PCR and JDP primer PCR. In the present study, LAMP assay based on directly heat-treated samples was found to be as efficient at detecting Acanthamoeba as DNA extracted using a commercial kit, whereas PCR was only effective when commercial kit-extracted DNA was used. This study showed that the devised Acanthamoeba LAMP assay could be used to diagnose AK in a simple, sensitive, and specific manner.

Investigation of bovine leukemia virus infection in dairy farms of northern Gyeonggi province, Korea (경기도 북부지역 젖소 사육농장의 bovine leukemia virus 감염 실태 조사)

  • Jung, Kwang;Shim, Hang-Sub;Baek, Jin-Joo
    • Korean Journal of Veterinary Service
    • /
    • v.35 no.4
    • /
    • pp.333-337
    • /
    • 2012
  • This study was carried out to investigate the prevalence of bovine leukemia virus (BLV) infection and to compare the results of enzyme-linked immunosorbent assay (ELISA) and nested polymerase chain reaction (nPCR) in dairy farms in northern Gyeonggi province from August through December 2011. A total of 625 dairy cattle from 14 dairy farms were tested for antibodies against BLV using commercially available ELISA test kit. The overall seroprevalence of BLV infection was 76.3%. The seroprevalence of diary cattle according to age was the highest at 61~72 months (88.0%, P<0.001). Two hundred fifty one dairy cattle from 7 diary farms were tested ELISA and nPCR. The kappa value of BLV between ELISA and nPCR was 0.765. The results indicate that BLV infection spread widely in dairy farms and the nPCR is rapid method for the early detection of BLV infection.

Forensic STR Analysis of Mixed Chimerism after Allogeneic Bone Marrow Transplantation

  • Eom, Yong-Bin
    • Biomedical Science Letters
    • /
    • v.16 no.3
    • /
    • pp.193-196
    • /
    • 2010
  • Multiplex PCR-based short tandem repeat (STR) analysis is considered as a good tool for monitoring bone marrow engraftment after sex-mismatched allogeneic transplantation and provides a sensitive and accurate assessment of the contribution of both donor and/or recipient cells in post-transplantation specimens. Forensic STR analysis and quantitative real time PCR are used to determine the proportion of donor versus recipient each contained within the total DNA. The STR markers were co-amplified in a single reaction by using commercial $PowerPlex^{(R)}$ 16 system and $AmpFISTR^{(R)}$ $Identifiler^{(R)}$ / $Yfiler^{(R)}$ PCR amplification kits. Separation of the PCR products and fluorescence detection were performed by ABI $PRIS^{(R)}$ 3100 Genetic Analyzer with capillary electrophoresis. The $GeneMapper^{TM}$ ID software were used for size calling and analysis of STR profiles. Extracted DNA was quantified by the $Quantifiler^{TM}$ Human DNA / Y Human Male DNA Quantification Kit The intent of this study was to analyze the ratio of donor versus recipient cells in the post-transplant peripheral blood, spleen, lung and kidney specimens. Specimens were taken from the traffic accident male victim who had been engrafted from bone marrow female donor. Blood and spleen specimens displayed female donor DNA profile. Kidney specimen showed male recipient DNA profile. Interestingly, lung tissue showed mixed profiles. The findings of this study indicate that the forensic STR analysis using fluorescence labeling PCR combined with capillary electrophoresis is quick and reliable enough to assess the ratio of donor versus recipient cells and to monitor the mixed chimeric patterns.

Development and Assessment of New RT-qPCR Assay for Detection of HIV-1 Subtypes

  • Lim, Kwanhun;Park, Min;Lee, Min Ho;Woo, Hyun Jun;Kim, Jong-Bae
    • Biomedical Science Letters
    • /
    • v.22 no.3
    • /
    • pp.83-97
    • /
    • 2016
  • The measurement of viral load in HIV-1 infected patients is essential for the establishment of a therapeutic strategy. Several commercial assays have shown shortcomings in quantifying rare genotypes of HIV-1 such as minor groups of N and O. In this study, the HIV-1 RT-qPCR assay was developed. The primers and probe of HIV-1 were designed to target the pol gene and to increase the detection efficiency of various subtypes including group N and O. The HIV-1 quantitative RT-qPCR assay was assessed for its analytical performance and clinical evaluation. The LoD was determined to 33.9 IU/ml. The LoD of several subtypes including A, C, D, CRF_01AE, F, CRF_02AG, G and H, were determined to less than 40 IU/ml. The HIV-1 quantitative RT-qPCR assay was evaluated using the China National Reference Panel of HIV-1 RNA to determine the analytical performance. The results were all within the acceptable range. The clinical evaluation was performed at Hunan CDC in China. The clinical evaluation results were compared with those of the China domestic commercial kit. A significant correlation (fresh samples; $R^2=0.84$, P<0.001, frozen samples; $R^2=0.76$, P<0.001) between the two systems was observed for 64 fresh samples and 76 frozen samples with viral loads, and the Bland-Altman plot showed good agreement (98.4%, 96.1%, respectively). In conclusion, the HIV-1 quantitative RT-qPCR assay had comparable analytical performance with several commercial kits. The study provides basic data for the research of HIV-1 diagnosis and the development of P < HIV-1 molecular diagnostic assay.

Nonspecific Mouse Hepatitis Virus Positivity of Genetically Engineered Mice Determined by ELISA

  • Han, Dae Jong;Kim, Hyuncheol;Yeom, Su-Cheong
    • Biomedical Science Letters
    • /
    • v.21 no.1
    • /
    • pp.9-14
    • /
    • 2015
  • Mouse hepatitis virus (MHV) is a major pathogen in laboratory mice that usually leads to fatal diseases, such as hepatitis, multiple sclerosis, encephalitis, and respiratory disease. MHV has a high infection rate, and it needs to be detected as soon as possible to prevent its spread to other facilities. However, MHV detection by enzyme-linked immunosorbent assay (ELISA) often gives false positives; thus, it is very important that the results are confirmed as true positives in the early infection stage or distinguished as false positives with more accurate, reliable methods. Under microbiological screening, MHV ELISA-positive mice were found in four GFP-tagging transgenic mice. To verify the detection of the MHV antigen directly, reverse transcription polymerase chain reaction (RT-PCR) was performed, and the mice were determined to be MHV negative. Additional serum antibody-based screening was conducted with three different ELISA kits, and multiplexed fluorometric immunoassay (MFIA) was performed to confirm their accuracy/sensitivity. In brief, the ELISA kit for A59 nucleocapsid protein (MHV-A59N) revealed MHV ELISA positivity, while other ELISA kits (MHV-S lysate and MHV-JHM lysate) demonstrated MHV negativity. In MFIA, only the test for the recombinant A59 nucleocapsid antigen was MHV positive, which was consistent with the ELISA results. These results suggest that the ELISA kit with the recombinant A59 nucleocapsid antigen might induce non-specific MHV ELISA positivity and that confirmation is therefore essential.

Rapid Extraction of DNA using Ion Exchange Resin for Early Detection of Mycobacterium tuberculosis by the Polymerase Chain Reaction (결핵균 PCR에서 이온교환수지를 이용한 신속한 DNA 분리)

  • Kim, Cheol-Min;Park, Seung-Kyu;Shon, Mal-Hyun;Song, Sun-Dae;Kim, Young;Jun, Eun-Sook;Son, Han-Chul;Jung, Byung-Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.30-37
    • /
    • 1996
  • Background: The extraction methods of DNA from clinical samples are the major obstacle to use the PCR(polymerase Chain Reaction) in routine labortary for early detection of M. tuberculosis. We tried to improve the extraction method of DNA from sputum for establishment of the PCR in routine labortary by reducing the possibility of cross contamination and performing it easily and safely. Methods: We used the $InstaGene^{TM}$ DNA extraction kit(BioRad Co.) using Chelex 100 ion exchange resin for preparation of DNA. We compared InstaGene method in 100 cases of sputum from proteinase K method which is known as the most commonly used method for DNA purification(Experiment 1). And we compared InstaGene method in 98 cases of sputum from Microwave method developed by a company in Korea(Experiment 2). In experiment 1,245bps of IS6110 were amplified and then 188bps were amplified by nested PCR. In experiment 2,536bps in primary PCR and 276bps in nested PCR were amplified and analysed by agarose gel electrophoresis and EtBr staining. Results: When we chose AFB smear, culture, or AFB smear and culture as a standard test, PCR had low specificity and positive predictive value in both experiments. The InstaGene method has higher value in sensitivity and negative predictive value significantly than proteinase K method. The InstaGene method and the Microwave methods were similar in sensitivity, specificity, positive predictive value and negative predictive value. Conclusion: Even though both methods had lower possibility of cross contamination, shorter time requirement, simplicity, and economic advantages than Proteinase K method, the InstaGene method was a little simpler than the Microwave method. Therefore, in terms of usefulness in clinical application, the Instagene method seems to be the most useful method in DNA extraction for detection of M. tuberculosis using PCR. The reliability of this method will be clarified by further studies with enough clinical samples.

  • PDF

Evaluation of MT1XT20 Single Quasi-Monomorphic Mononucleotide Marker for Characterizing Microsatellite Instability in Persian Lynch Syndrome Patients

  • Farahani, Najmeh;Nikpour, Parvaneh;Emami, Mohammad Hassan;Hashemzadeh, Morteza;Zeinalian, Mehrdad;Shariatpanahi, Seyed Shervin;Salehi, Rasoul
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.9
    • /
    • pp.4259-4265
    • /
    • 2016
  • Background: Colorectal malignancies with high microsatellite instability (MSI-H), either hereditary (Lynch syndrome) or sporadic, demonstrate better prognosis and altered response to 5FU chemotherapy. It is now recommended to perform MSI testing for all new cases of colorectal cancer regardless of being categorized as hereditary or sporadic. For MSI detection, immunohistochemistry or PCR-based protocols using a cohort of various sets of STR markers are recommended. Here we aimed to evaluate a simplified protocol using just a single STR marker, MT1XT20 mononucleotide repeat, for detection of MSI in Lynch syndrome patients. A Promega five-marker MSI testing panel and immunohistochemistry (IHC) were used as the gold standard in conjunction with MT1XT20. Materials and Methods: Colorectal patients with a positive history of familial cancers were selected by evaluating medical records. Based on Amsterdam II criteria for Lynch syndrome 20 families were short listed. DNA was extracted from formalin fixed paraffin embedded tumour and adjacent normal tissues resected from the index case in each family. Extracted DNA was subjected to MT1XT20 mononucleotide marker analysis and assessment with a commercially available five marker MSI testing kit (Promega, USA). IHC also was performed on tissue sections and the results were compared with PCR based data. Results: Eight (40%), seven (35%) and five (25%) cases were MSI positive using with the Promega kit, IHC and MT1XT20, respectively. Among the markers included in Promega kit, BAT26 marker showed instability in all 8 samples. NR24 and NR21 markers showed instability in 7 (87.5%), and BAT25 and MONO 27 in 6 (75%) and 5 (62.5%). Conclusions: Although MT1XT20 was earlier reported as a valid standalone marker for MSI testing in CRC patients, we could not verify this in our Iranian patients. Instead BAT26 among the markers included in Promega MSI testing kit showed instability in all 8 MSI-H CRC samples. Therefore, it seems BAT26 could act well as a single marker for MSI testing in Iranian CRC patients.

Diagnosis of porcine reproductive and respiratory syndrome (PRRS) and its serological survey using the reverse transcription and polymerase chain reaction (RT-PCR) and ELISA (RT-PCR과 ELISA를 이용한 PRRS 진단 및 항체가 조사)

  • Chu Keum-Suk;Han Keu-Sam;Han Jae-Cheol;Song Hee-Jong
    • Korean Journal of Veterinary Service
    • /
    • v.27 no.3
    • /
    • pp.273-280
    • /
    • 2004
  • The studies were performed for the PRRS antigen and antibody detection from breeding farms, artificial insemination(AI) center and growing farms in Jeonbuk province. 1. Specific PRRS primers were successfully amplified ORF6 617bp and ORF7 448 bp on agarose gel. 2. RT-PCR method has been establish by commercial kit and the thermal cycler program consisted of 30 cycles: $95^{\circ}C$ for 30 sec, $45^{\circ}C$ for 30 sec, and $72^{\circ}C$ for 45 sec. 3. The results of PRRS antibody test by ELISA method in AI centers were $6.6\%,\;53.3\%$ and breeding farms $65\%,\;65\%\;and\;38.7\%$, respectively. The serological positive of the antibody in gilt higher than sow. 4. The sero-positive of the PRRS antibody showed average $21\%$ in domestic farms, $56.2\%$ in breeding farms, and $29.9\%$ in AI center.

Development of Two Quantitative Real-Time PCR Diagnostic Kits for HPV Isolates from Korea

  • Jeeva, Subbiah;Kim, Nam-Il;Jang, In-Kwon;Choi, Tae-Jin
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.10
    • /
    • pp.1350-1358
    • /
    • 2012
  • Viral pathogens, alongside other pathogens, have major effects on crustacean aquaculture. Hepatopancreatic parvovirus (HPV) is an emerging virus in the shrimp industry and has been detected in shrimp farms worldwide. The HPV genome has greater diversity than other shrimp viruses owing to its wide host range and geographical distribution. Therefore, developing diagnostic tools is essential to detect even small copy numbers from the target region of native HPV isolates. We have developed two easy to use quantitative real-time PCR kits, called Green Star and Dual Star, which contain all of the necessary components for real-time PCR, including HPV primers, using the primers obtained from the sequences of HPV isolates from Korea, and analyzed their specificity, efficiency, and reproducibility. These two kits could detect from 1 to $1{\times}10^9$ copies of cloned HPV DNA. The minimum detection limits obtained from HPV-infected shrimp were $7.74{\times}10^1$ and $9.06{\times}10^1$ copies in the Green Star and Dual Star assay kits, respectively. These kits can be used for rapid, sensitive, and efficient screening for HPV isolates from Korea before the introduction of postlarval stages into culture ponds, thereby decreasing the incidence of early development of the disease.