• Title/Summary/Keyword: PCR detection assay

Search Result 517, Processing Time 0.042 seconds

Detection of Salmonella typhi by Loop-mediated Isothermal Amplification Assay

  • Jo, Yoon-Kyung;Lee, Chang-Yeoul
    • Biomedical Science Letters
    • /
    • v.14 no.2
    • /
    • pp.115-118
    • /
    • 2008
  • Salmonella typhi is frequent causes of foodborne illness and its detection is important for monitoring disease progression. In this study, by using general PCR and novel LAMP (Loop Mediated Isothermal Amplification) assay, we evaluated the usefulness of LAMP assay for detection of Salmonella typhi. In this LAMP assay, forward inner primer (FIP) and back inner primer (BIP) was specially designed for recognizing target invA gene. Target DNA was amplified and visualized as ladder-like pattern of bands on agarose gel within 60 min under isothermal conditions at $65^{\circ}C$. When the sensitivity and reproducibility of LAMP were compared to general PCR, there was no difference of reproducibility but sensitivity of LAMP assay was more efficient than PCR (the detection limit of LAMP assay was 30 fg, while the PCR assay was 3 pg). These results indicate that the LAMP assay is a potential and valuable means for detection of Salmonella typhi, especially for its rapidity, simplicity and low cost.

  • PDF

Comparison of Isolation Agar Method, Real-Time PCR and Loop-Mediated Isothermal Amplification-Bioluminescence for the Detection of Salmonella Typhimurium in Mousse Cake and Tiramisu (Mousse cake와 Tiramisu에 인위접종된 Salmonella Typhimurium의 식품공전 분리배지, Real-time PCR과 Loop-mediated isothermal amplification-bioluminescence의 검출 특성 비교)

  • Lee, So-Young;Gwak, Seung-Hae;Kim, Jin-Hee;Oh, Se-Wook
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.290-295
    • /
    • 2019
  • Salmonella spp. are frequently associated with food and are among the most important foodborne pathogens. The recent Salmonella out breaks in Korea was associated with chocolate mousse cakes served with school meals during September 2018. The objective of this research was to compare the 3M Molecular Detection Assay 2 - Salmonella and the Korean Standard Method of Salmonella in artificially inoculated mousse (chocolate and cheese) and tiramisu cakes. Mousse (chocolate and cheese) and tiramisu cakes were artificially inoculated with S. Typhimurium. Twenty five gram of sample was enriched with 225 mL buffered peptone water for incubation at $37^{\circ}C$ for 24 h. After enrichment, the cultures were analyzed by using the 3M Molecular Detection Assay 2 - Salmonella and the Korean Standard Method. Most of the inoculated samples showed similar results except the chocolate mousse cakes, in which real-time PCR was unable to detect S. Typhimurium even after $10^4CFU/25g$ of inoculation. However, S. Typhimurium inoculated at a concentration of $10^0CFU/25g$ was detected by using 3M Molecular Detection Assay 2 - Salmonella. In chocolate mousse, detection of S. Typhimurium using real-time PCR was partially successful when dark chocolate was added at less than 15%. Negative results in real-time PCR and 3M Molecular Detection Assay 2 - Salmonella were confirmed by gel electrophoresis. The data indicated that dark chocolate could inhibit amplification of the target gene in the PCR reactions. In conclusion, the 3M Molecular Detection Assay 2 - Salmonella was better than the Korean Standard Method (real-time PCR) for the detection of S. Typhimurium in chocolate mousse cakes and chocolate mousse.

Rapid detection and quantification of porcine circovirus type 2 (PCV 2) DNA in Real-time PCR (Real-time PCR을 이용한 돼지써코바이러스 감염증 진단법 연구)

  • Kim, Eun-Gyeong;Hwang, Bo-Won;Lee, Jong-Min;Son, Byeong-Guk;Park, Ho-Jung;Kim, Tho-Kyoung
    • Korean Journal of Veterinary Service
    • /
    • v.32 no.4
    • /
    • pp.299-306
    • /
    • 2009
  • Assay for the detection and quantification of porcine circovirus type 2 (PCV 2) with the real-time PCR were developed. TaqMan probe real-time using a set of primer/probe was developed for detection of PCV 2. In this study we applied real-time PCR assay to 320 samples, collected from pig farms. In 151 of 320 samples, PCV 2 DNA was detected by conventional PCR assay. All samples positive for PCV 2 DNA in conventional PCR assay were also positive in Real-time PCR assay, but 69 of 169 samples that tested negative for PCV 2 DNA in conventional assay were tested positive in TaqMan probe real-time PCR assay. The test of TaqMan probe real-time PCR resulted in detection and quantification limits of 101 copies per sample. TaqMan probe real-time PCR assay increased the number of samples in which PCV 2 was detected by 21%. TaqMan probe real-time PCR assay is very efficient method in contrast to the conventinal PCR, becoming increasingly important method for gene analysis.

Evaluation of Various Real-Time Reverse Transcription Quantitative PCR Assays for Norovirus Detection

  • Yoo, Ju Eun;Lee, Cheonghoon;Park, SungJun;Ko, GwangPyo
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.4
    • /
    • pp.816-824
    • /
    • 2017
  • Human noroviruses are widespread and contagious viruses causing nonbacterial gastroenteritis. Real-time reverse transcription quantitative PCR (real-time RT-qPCR) is currently the gold standard for the sensitive and accurate detection of these pathogens and serves as a critical tool in outbreak prevention and control. Different surveillance teams, however, may use different assays, and variability in specimen conditions may lead to disagreement in results. Furthermore, the norovirus genome is highly variable and continuously evolving. These issues necessitate the re-examination of the real-time RT-qPCR's robustness in the context of accurate detection as well as the investigation of practical strategies to enhance assay performance. Four widely referenced real-time RT-qPCR assays (Assays A-D) were simultaneously performed to evaluate characteristics such as PCR efficiency, detection limit, and sensitivity and specificity with RT-PCR, and to assess the most accurate method for detecting norovirus genogroups I and II. Overall, Assay D was evaluated to be the most precise and accurate assay in this study. A ZEN internal quencher, which decreases nonspecific fluorescence during the PCR, was added to Assay D's probe, which further improved the assay performance. This study compared several detection assays for noroviruses, and an improvement strategy based on such comparisons provided useful characterizations of a highly optimized real-time RT-qPCR assay for norovirus detection.

Quantitative Detection of Residual E. coli Host Cell DNA by Real-Time PCR

  • Lee, Dong-Hyuck;Bae, Jung-Eun;Lee, Jung-Hee;Shin, Jeong-Sup;Kim, In-Seop
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.10
    • /
    • pp.1463-1470
    • /
    • 2010
  • E. coli has long been widely used as a host system for the manufacture of recombinant proteins intended for human therapeutic use. When considering the impurities to be eliminated during the downstream process, residual host cell DNA is a major safety concern. The presence of residual E. coli host cell DNA in the final products is typically determined using a conventional slot blot hybridization assay or total DNA Threshold assay. However, both the former and latter methods are time consuming, expensive, and relatively insensitive. This study thus attempted to develop a more sensitive real-time PCR assay for the specific detection of residual E. coli DNA. This novel method was then compared with the slot blot hybridization assay and total DNA Threshold assay in order to determine its effectiveness and overall capabilities. The novel approach involved the selection of a specific primer pair for amplification of the E. coli 16S rRNA gene in an effort to improve sensitivity, whereas the E. coli host cell DNA quantification took place through the use of SYBR Green I. The detection limit of the real-time PCR assay, under these optimized conditions, was calculated to be 0.042 pg genomic DNA, which was much higher than those of both the slot blot hybridization assay and total DNA Threshold assay, where the detection limits were 2.42 and 3.73 pg genomic DNA, respectively. Hence, the real-time PCR assay can be said to be more reproducible, more accurate, and more precise than either the slot blot hybridization assay or total DNA Threshold assay. The real-time PCR assay may thus be a promising new tool for the quantitative detection and clearance validation of residual E. coli host cell DNA during the manufacturingprocess for recombinant therapeutics.

An Improved PCR-RFLP Assay for Detection and Genotyping of Asymptomatic Giardia lamblia Infection in a Resource-Poor Setting

  • Hawash, Yoursry;Ghonaim, M.M.;Al-Shehri, S.S.
    • Parasites, Hosts and Diseases
    • /
    • v.54 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • Laboratory workers, in resource-poor countries, still consider PCR detection of Giardia lamblia more costly and more time-consuming than the classical parasitological techniques. Based on 2 published primers, an in-house one-round touchdown PCR-RFLP assay was developed. The assay was validated with an internal amplification control included in reactions. Performance of the assay was assessed with DNA samples of various purities, 91 control fecal samples with various parasite load, and 472 samples of unknown results. Two cysts per reaction were enough for PCR detection by the assay with exhibited specificity (Sp) and sensitivity (Se) of 100% and 93%, respectively. Taking a published small subunit rRNA reference PCR test results (6%; 29/472) as a nominated gold standard, G. lamblia was identified in 5.9% (28/472), 5.2%, (25/472), and 3.6% (17/472) by PCR assay, $RIDA^{(R)}$ Quick Giardia antigen detection test (R-Biopharm, Darmstadt, Germany), and iodine-stained smear microscopy, respectively. The percent agreements (kappa values) of 99.7% (0.745), 98.9% (0.900), and 97.7% (0.981) were exhibited between the assay results and that of the reference PCR, immunoassay, and microscopy, respectively. Restriction digestion of the 28 Giardia-positive samples revealed genotype A pattern in 12 and genotype B profile in 16 samples. The PCR assay with the described format and exhibited performance has a great potential to be adopted in basic clinical laboratories as a detection tool for G. lamblia especially in asymptomatic infections. This potential is increased more in particular situations where identification of the parasite genotype represents a major requirement as in epidemiological studies and infection outbreaks.

Detection and Quantification of Apple Stem Grooving Virus in Micropropagated Apple Plantlets Using Reverse-Transcription Droplet Digital PCR

  • Kim, Sung-Woong;Lee, Hyo-Jeong;Cho, Kang Hee;Jeong, Rae-Dong
    • The Plant Pathology Journal
    • /
    • v.38 no.4
    • /
    • pp.417-422
    • /
    • 2022
  • Apple stem grooving virus (ASGV) is a destructive viral pathogen of pome fruit trees that causes significant losses to fruit production worldwide. Obtaining ASGV-free propagation materials is essential to reduce economic losses, and accurate and sensitive detection methods to screen ASGV-free plantlets during in vitro propagation are urgently necessary. In this study, ASGV was sensitively and accurately quantified from in vitro propagated apple plantlets using a reverse transcription droplet digital polymerase chain reaction (RT-ddPCR) assay. The optimized RT-ddPCR assay was specific to other apple viruses, and was at least 10-times more sensitive than RT-real-time quantitative PCR assay. Furthermore, the optimized RT-ddPCR assay was validated for the detection and quantification of ASGV using micropropagated apple plantlet samples. This RT-ddPCR assay can be utilized for the accurate quantitative detection of ASGV infection in ASGV-free certification programs, and can thus contribute to the production of ASGV-free apple trees.

Detection of Xanthomonas axonopodis pv. glycines and Survey on Seed Contamination in Soybean Seeds Using PCR Assay (PCR Assay 이용 콩 종자에서 Xanthomonas axonopodis pv. glycines 검출 및 종자오염 조사)

  • Hong, Sung-Jun;Hong, Yeon-Kyu;Lee, Bong-Choon;Lim, Mi-Jung;Yoon, Young-Nam;Hwang, Jae-Bok;Song, Seok-Bo;Park, Sung-Tae
    • Research in Plant Disease
    • /
    • v.13 no.3
    • /
    • pp.145-151
    • /
    • 2007
  • Xanthomonas axonopodis pv. glycines is the causal agent of bacterial pustule of soybean(Glycine max. (L.) Merr), which is one of the most prevalent bacterial diseases in Korea. In this study, Polymerase Chain Reaction (PCR) assay was applied to detect Xanthomonas axonopodis pv. glycines and to survey on seed contamination in 36 soybean cultivars of Korea. And we have to compare PCR assay with dilution-plating assay of detection and identification. We confirmed detection of pathogen from artificial infected seeds and natural Infected seeds using PCR assay. This assay gave results similar to a seed-wash dilution plating assay and proved more effective than classical methods. Results of survey on seed contamination by X. axonopodis pv. glycines from 36 cultivar seeds showed that the pathogen was detected from Pungsan-namulkong, Mallikong, Taekwangkong, Daemangkong, Ajukkarikong using PCR assay. Therefore, The PCR assay provides a sensitive, rapid tool for the specific detection of X. axonopodis pv. glycines in soybean seeds.

Prevalence of feline calicivirus in Korean cats determined by an improved real-time RT-PCR assay

  • Ji-Su Baek;Jong-Min Kim;Hye-Ryung Kim;Yeun-Kyung Shin;Oh-Kyu Kwon;Hae-Eun Kang;Choi-Kyu Park
    • Korean Journal of Veterinary Service
    • /
    • v.46 no.2
    • /
    • pp.123-135
    • /
    • 2023
  • Feline calicivirus (FCV) is considered the main viral pathogen of feline upper respiratory tract disease (URTD). The frequent mutations of field FCV strains result in the poor diagnostic sensitivity of previously developed molecular diagnostic assays. In this study, a more sensitive real-time reverse transcription-polymerase chain reaction (qRT-PCR) assay was developed for broad detection of currently circulating FCVs and comparatively evaluated the diagnostic performance with previously developed qRT-PCR assay using clinical samples collected from Korean cat populations. The developed qRT-PCR assay specifically amplified the FCV p30 gene with a detection limit of below 10 copies/reaction. The assay showed high repeatability and reproducibility, with coefficients of intra-assay and inter-assay variation of less than 2%. Based on the clinical evaluation using 94 clinical samples obtained from URTD-suspected cats, the detection rate of FCV by the developed qRT-PCR assay was 47.9%, which was higher than that of the previous qRT-PCR assay (43.6%). The prevalence of FCV determined by the new qRT-PCR assay in this study was much higher than those of previous Korean studies determined by conventional RT-PCR assays. Due to the high sensitivity, specificity, and accuracy, the new qRT-PCR assay developed in this study will serve as a promising tool for etiological and epidemiological studies of FCV circulating in Korea. Furthermore, the prevalence data obtained in this study will contribute to expanding knowledge about the epidemiology of FCV in Korea.

A Rapid PCR-based Assay for Detecting Hepatitis B Viral DNA Using GenSpector TMC-1000

  • Huh, Bum;Ha, Young-Ju;Oh, Jae-Tak;Park, Eun-Ha;Park, Jin-Su;Park, Hae-Joon
    • Journal of Applied Biological Chemistry
    • /
    • v.49 no.4
    • /
    • pp.143-147
    • /
    • 2006
  • A rapid PCR-based assay for detecting hepatitis B viral DNA(HBV DNA) in serum and plasma was developed using a new PCR instrument named GenSpector(TMC-1000, Samsung electronics). PCR was carried out using a chip-based platform, which enabled 50 PCR cycles with internal controls, and melting-curve analysis in 30 minutes. Verification of the amplified HBV DNA product and the internal control was based on specific melting temperatures(Tm) analysis, executed by the GenSpector software. Primers were designed within the region conserved through HBV genotypes A to F. The lower limit of detection was 840 copies/ml serum, conducted with serial dilutions of a HBV DNA positive control(ACCURUN 325 series 700, Boston Biomedica Inc.). The assay was also compared to another assay for HBV DNA(Versant HBV DNA 3.0 assay, Bayer HealthCare) for 200 samples(each 100 clinical negative and positive samples). The sensitivity and specificity were 100% matched. This rapid PCR-based assay is specific, reproducible, and enables qualitative detection of HBV DNA.