• Title/Summary/Keyword: PCL index

Search Result 12, Processing Time 0.029 seconds

The Relationship between the Anterior Cruciate Ligament Tear and the Posterior Cruciate Ligament Index on MRI Findings (자기공명영상 상 전방십자인대 파열과 후방십자인대 곡선값의 연관성)

  • Kang Jae Do;Kim Kwang Yul;Kim Hyung Cheon;Lee Sung Chun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.109-114
    • /
    • 2002
  • Propose : The purpose of this retrospective study was to test the posterior cruciate ligament (PCL index) for diagnosis of a tear of the anterior cruciate ligament (ACL) by means of MR imaging. Materials and Methods : From Mar. 1997 to Feb. 2001, concomitant magnetic resonance imaging (MRI) and knee joint arthroscopy were performed in 56 patients of either pain or instability of the knee. The shortest distance between the femoral and tibial attachment of PCL (X) and the distance from that line to the tip of the arc marked by the PCL (Y) on the sagittal plane images were measured. The quotient of these two parameters (Y/X) defined the PCL index. Results : Using MRI diagnosis, there were 35 patients diagnosed with ACL rupture and 21 patients were ruled out of ACL injury. Using arthroscopy, 32 of the 35 patients diagnosed by MRI showed ACL rupture, and 20 of the 21 patients were ruled out of ACL injury. The mean PCL index was 0.40 in the 33 patients diagnosed with ACL rupture through arthroscopy. The mean PCL index was 0.23 in 23 patients with an uninjured ACL through arthroscopy. In 33 patients with ruptured ACL, this value exceeds 0.31. The index value was 0.31 in 3 patients with uninjured ACL. The value of the index was not above 0.31 with an uninjured ACL. PCL index on MRI had a sensitivity of $91\%$ and a specificity of $94\%$ for determining the status of the anterior cruciate ligament. Conclusion : Injury to the ACL changes the PCL index markedly. In diagnostically unreliable MR images, amelioration of the PCL index could help in the diagnosis of ACL injury.

  • PDF

Synthesis and Thermal Property of Poly(styrene-g-caprolactone) with Well-defined Structure (분자구조가 제어된 Poly(styrene-g-caprolactone)의 합성 및 그라프트 공중합체의 열적 성질)

  • 오병석;안성국;조창기
    • Polymer(Korea)
    • /
    • v.24 no.3
    • /
    • pp.306-313
    • /
    • 2000
  • Polycaprolactone (PCL) macromer containing terminal methacrylate group was synthesized by ring-opening polymerization. The number average molecular weight of PCL macromer was 11600 g/mole and polydispersity index was 1.09. The synthesized PCL macromer was copolymerized with styrene by stable free radical polymerization using 2,2,6,6-tetramethyl-1-piperidinyloxy (TEMPO), benzoyl peroxide, and well-defined poly(styrene-g-caprolactone)s were synthesized. The synthesized copolymers was characterized by $^1$H-NMR and gel permeation chromatography equipped with multiangle laser light scattering detector. Thermal properties of graft copolymers were investigated by DSC.

  • PDF

Refractive Indexes of Porous Thin Films Prepared From Organic-templated Polymethylsilsesquioxanes

  • Kim, Jung-Soo;Nam, Dae-Geun;Oh, Weontae
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.6
    • /
    • pp.305-308
    • /
    • 2014
  • Organosilyl-modified and star-shaped poly (${\varepsilon}$-caprolactone) (m-PCL) was prepared, and added to polymethylsilsesquioxane (PMSSQ), to make composites. The end groups of m-PCL are chemically similar to PMSSQ, and m-PCL mixed well with PMSSQ in the composite. Porous PMSSQ film was made by further calcination of the composite film at elevated temperature. m-PCL-templated PMSSQ and the as-prepared porous PMSSQ were structurally, optically, and thermally characterized in thin films. The chemical binding of m-PCL and PMSSQ effectively suppressed the phase separation of PMSSQ and m-PCL during the curing process. After calcination at elevated temperature, there remained many pores in the PMSSQ matrix. The refractive indices of the resulting porous PMSSQ thin films decreased with increase of the film porosities, depending on the initial m-PCL loadings.

Laser Beam Scattering Analysis in Aqueous Environments (액상유체 환경하에서 레이저빔의 산란 해석)

  • Choi, Hae Woon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.2
    • /
    • pp.91-95
    • /
    • 2019
  • A new experimental approach is proposed to detect a specific polymer dissolved in a liquid. Distinctive optical properties were found using a laser scattering technique when there is a polymer compound with almost no difference in optical properties (index of refraction) in a liquid phase. The index of refraction, which determines the refraction of light, is obtained by dissolving PCL and PLA. The used samples are biodegradable materials with similar properties and dissolved in a mixture of Chloroform 7: Methanol 3. To predict the optical properties, a 632-nm diode laser was used as the light source of the device, and an integrating sphere was used as the light receiver. Although PCL and PLA had a similar index of refraction of 1.46-1.48, the dissolved PCL showed a relative transmittance of 43%, and the dissolved PLA had a relative transmittance of 34%. The difference in optical properties of the pure polymer compound in the solid state or liquid state is not significantly different, and the difference in the dissolved state in the specific solvent is remarkable because the solubility differs in a specific solution and is randomly distributed.

EFT and Korean Medicine Treatment for ASD Induced by a Traffic Accident: A Case Report (교통사고 상해증후군 환자의 급성 스트레스 장애에 시행한 한의치료와 EFT 치료 치험 1례)

  • Chaewon Son;Jinyoug Kang;Backjun Kim;Wonjeong Ha;Hwan Kim
    • Journal of Oriental Neuropsychiatry
    • /
    • v.34 no.2
    • /
    • pp.115-124
    • /
    • 2023
  • Objectives: To report the efficacy of using EFT and Korean medicine treatment for ASD induced by a traffic accident. Methods: We treated ASD symptoms with Korean medicine (acupuncture, cupping, interferential current therapy, herbal acupuncture therapy). To evaluate results of this treatment, Korean version of PTSD Checklist-5 (PCL-5-K), Beck Depression Inventory (BDI), Insomnia Severity Index (ISI), and Numeric rating scale (NRS) at first visit, 5 weeks, and 12 weeks were used. Results: Korean version of PTSD Checklist-5 (PCL-5-K), Beck Depression Inventory (BDI), Insomnia Severity Index (ISI), and Numeric rating scale (NRS) showed improvements after treatments. Conclusions: This study suggests that Korean medicine and EFT treatment might be effective for ASD.

The Relationship between Heart Rate Variability and Symptoms in Subjects with Chronic Posttraumatic Stress Disorder (만성 외상 후 스트레스 장애 환자에서 심박변이도와 증상과의 상관관계 : 외상증상과 심박변이도 관계)

  • Park, Jinsoo;Kang, Sukhoon;Park, Joo Eon;Choi, Jin Hee;So, Hyung Seok;Kim, Kiwon;Choi, Hayun
    • Anxiety and mood
    • /
    • v.16 no.2
    • /
    • pp.83-90
    • /
    • 2020
  • Objective : Heart rate variability (HRV) is known to reflect autonomic nervous system activity. Individuals with posttraumatic stress disorder (PTSD) are reported to have lower HRVs. We attempted to find HRV indices with head up tilt position that reflect the symptoms well in order to evaluate PTSD symptoms. Methods : Sixty-seven patients with PTSD and 72 patients without PTSD were assessed using the PTSD Checklist for DSM-5 (PCL-5), the Beck Depression Inventory, the Beck Anxiety Inventory and the Pittsburgh Sleep Quality Index. HRV was measured in the head-up tilt position. We collected data regarding heart rate (HR), standard deviation of the NN intervals (SDNN), the square root of the mean squared differences of successive NN intervals (RMSSD), log low-frequency (LNLF) and log high-frequency (LNHF). Results : The value of LNHF was different according to presence or absence of PTSD after head-up tilt position. In the findings of the association between PTSD symptoms and HRV indices as based on head-up tilt, LNHF had a significant correlation with the total score of PCL-5. Conclusion : The reduction of the high-frequency component of HRVs in the PTSD group might reflect more PTSD symptoms.

Effect of Polyethylene Glycol Molecular Weight and NCO Index on Properties of the Hydrophilic Reactive Hotmelt Polyurethane Adhesives (Polyethylene Glycol의 분자량 및 NCO index의 변화에 따른 Hydrophilic Reactive Hotmelt Polyurethane의 물성 변화)

  • Han, Young Chul;Kim, Dack Han;Oh, Kyung Seok;Shin, Hyeon Jeong;Yang, Jeong Han;Jeong, Han Mo
    • Textile Coloration and Finishing
    • /
    • v.30 no.2
    • /
    • pp.90-97
    • /
    • 2018
  • Hydrophilic reactive hot-melt polyurethane adhesive(HRHA) using a hydrophilic polyol having different molecular weight and NCO index was synthesized. This HRHA was synthesized using Polyethylene glycol(PEG) as a hydrophilic polyol, Polypropylene glycol(PPG) and Polycaprolactone diol(PCL) as hydrophobic polyols, and Methylene diphenyl diisocyanate(MDI) as an isocyanate. The changes in IR spectrum, viscosity and thermal properties of HRHA with different PEG molecular weights and NCO index were investigated, and the tensile strength and elongation of the HRHA casting film and the peel strength, moisture permeability and water pressure of the HRHA coated fabric were confirmed. In this experiment, as the molecular weight of PEG and NCO index increased, the adhesive strength, tensile strength, elongation and moisture permeability was increased but viscosity and Tg was decreased.

Development of a Multi-nozzle Bioprinting System for 3D Scaffold Fabrication (3차원 지지체 제작을 위한 다중 분사체 노즐 바이오프린팅 시스템 개발)

  • Park, Sanghoon;Kim, Seongjun;Song, Seung-Joon;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.271-275
    • /
    • 2015
  • The aim of this study was to develop a multi-nozzle based bioprinting system for fabrication of three-dimensional (3D) biological structure. In this study, a thermoplastic biomaterial that has relatively high mechanical stability, polycaprolactone (PCL) was used to make the 3D structure. A multi-nozzle bioprinting system was designed to dispense thermoplastic biomaterial and hydrogel simultaneously. The system that consists of 3-axes of x-y-z motion control stage and a compartment for injection syringe control mounted on the stage has been developed. Also, it has 1-axis actuator for position change of nozzle. The controllability of the printed line width with PCL was tested as a representative performance index.

Preparation and Properties of Waterborne Poly(urethane-urea) Ionomers -Effect of the Type of Neutralizing Agent-

  • Yang, Jung-Eun;Lee, Young-Hee;Koo, Young-Seok;Jung, Young-Jin;Kim, Han-Do
    • Fibers and Polymers
    • /
    • v.3 no.3
    • /
    • pp.97-102
    • /
    • 2002
  • A series of waterbome poly(urethane-urea) anionomers were prepared from isophorone diisocyanate (IPDI), polycaprolactone diol (PCL), dimethylol propionic acid (DMPA), ethylene diamine (EDA), and triethylamine (TEA), NaOH, or Cu($(COOCH_3)_2$) as neutralizing agent. This study was performed to decide the effect of neutralizing agent type on the particle size viscosity, hydrogen bonding index, adhesive strength, antistaticity, antibacterial and mechanical properties. The particle size of the dispersions decreased in the following order: TEA based samples (T-sample), NaOH based samples (N-sample), and Cu($(COOCH_3)_2$) based sample (C-sample). The viscosity of the dispersions increased in the order of C-sample, N-sample, and T-sample. Metal salt based film samples Of and C-sample) had much higher antistaticity than TEA based sample. By infrared spectroscopy, it was found that the hydrogen bonding index (or fraction) of samples decreased in the order of T-sam-pie, N-sample, and C-sample. The adhesive strength and tensile modulus/strength decreased in the order of T-sample, N-sam-pie, and C-sample. The C-sample had strong antibacterial halo, however, T- and N-samples did not

PHOSPHORUS NITRIDE FILMS ON InP SURFACE BY PHOTO-CVD (광CVD에 의한 InP기판 위에 질화인막의 성장)

  • Hong, Youg-Tae;Lee, Jae-Hak;Jeong, Yoon-Ha;Bae, Young-Ho;Kim, Kwang-Ill;Jeong, Wook-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.386-389
    • /
    • 1989
  • Phosphorus nitride films on InP surface were grown by a Photo-CVD (chemical vapor deposition) technique over 100-250 $^{\circ}C$ range of substrate temperature, which is based on direct photolysis of $PCl_3/H_2$ and $NH_3$ gas mixtures by 185nm ultraviolet light from a low pressure mercury lamp. The film growth rate ed the refractive index(n) were shown about 700-800 ${\AA}/hr$ and 1.7-1.8, respectively. Composition ratio and interface properties were analyzed by AES(Auger Electron Spectroscopy) and XPS (X-ray Photoelectron Spectorscopy) technique.

  • PDF