Development and Verification of Modular 3U Cubesat Standard Platform (3U 큐브위성 표준 플랫폼의 개발)

  • Song, Sua;Lee, Soo-Yeon;Kim, Hongrae;Chang, Young-Keun
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.5
    • /
    • pp.65-75
    • /
    • 2017
  • This study proposes development of 3U CubeSat standard platform whose function and performance are verified via KAUSAT-5 development. 3U CubeSat platform specification was selected for the design of 3U Cubesat standard platform by examining existing CubeSat and state-of-art technology, and consequently a universally usable 3U CubeSat platform was designed. Standard platform was manufactured in 1.5U size and developed with a modular concept to be able to add and expand payloads and ADCS actuators for meeting the user's needs. In addition, in case of the power system, the solar panel, the battery, and the deployment mechanism are designed to be configured by the user. In the mechanical system design of a standard platform, subsystem and micro equipment functions/performance could be integrated and miniaturized on micro-sized PCBs and maximized electrical capability to accommodate multiple payloads. In the development of the 3U CubeSat, the satellite platform adopts the developed standard platform, which can reduce the cost and schedule for the whole satellite development by reducing the additional function verification.

Effect of Sn Decorated MWCNT Particle on Microstructures and Bonding Strengths of the OSP Surface Finished FR-4 Components Assembled with Sn58%Bi Composite Solder Joints (OSP 표면처리된 FR-4 PCB기판과 Sn58%Bi 복합솔더 접합부의 미세조직 및 접합강도에 미치는 Sn-MWCNT의 영향)

  • Park, Hyun-Joon;Lee, Choong-Jae;Min, Kyung Deuk;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.163-169
    • /
    • 2019
  • Sn-Pb solder alloys in electronics rapidly has been replaced to Pb free solder alloys because of various environmental regulations such as restriction of hazardous substances directive (RoHS), European Union waste electrical, waste electrical and electronic equipment (WEEE), registration evaluation authorization and of chemicals (REACH) etc. Because Sn58%Bi (in wt.%) solder alloy has low melting point and higher mechanical properties than that of Sn-Pb solder, it has been studied to manufacture electronic components. However, the reliability of Sn58%Bi solder could be lowered because of the brittleness of Bi element included in the solder alloy. Therefore, we observed the microstructures of Sn58%Bi composite solders with various contents of Sn-decorated multiwalled carbon nanotube (Sn-MWCNT) particles and evaluated bonding strength of the FR-4 components assembled with Sn58%Bi composite solder. Also, microstructures and bonding strengths of the Sn58%Bi composite solder joints were evaluated with the number of reflows from 1 to 7 times, respectively. Bonding strengths and fracture energies of the Sn58%Bi composite solder joints were measured by die shear test. Microstructures and fracture modes were observed with scanning electron microscope (SEM). Microstructures in the Sn58%Bi composite solder joints were finer than that of only Sn58%Bi solder joint. Bonding strength and fracture energy of Sn58%Bi composite solder including 0.1 wt.% of Sn-decorated MWCNT particles increased up to 20.4% and 15.4% at 5 times in reflow, respectively.

Development of Frequency Weighing Sensor and Single Crystal Growth (새로운 무게센서 재발과 단결정성장(1))

  • Jang Y.N.;Sung N.H.;Chae S.C.;Bae I.K.;Kim I.J.
    • Korean Journal of Crystallography
    • /
    • v.8 no.1
    • /
    • pp.38-47
    • /
    • 1997
  • A new weighing sensor for the automatic diameter control system of the crystal growth is developed in this study. This weighing sensor measures the frequency of the vibrating element which is lineally changing with respect to weight. The signal and the power of this system are transmitted without any physical contact, so that this sensor offers high accuracy and resolution. This system consists of a string, a sinusoidal wave generator, an automatic amplification adjusting circuit, signal transformers and a PCB. 4 kinds of programs are developed for checking DAC, weight calibration and controlling growth process. The measurements of the standard deviation and the resolution show $\pm0.10g$(measured at every second) and $5{\times}10^{-5}$, respectively, This weighing sensor is effective under high pres-sure of 200 atm, high temperature and vacuum condition. The weighing system can control the temperature in the accuracy of $\pm0.025^{\circ}C$ with the 'signal divider'. The optical quality single crystals of $(YGd)_3Sc_2Ga_3O_{12},\;Er-Y_3Sc_2Al_3O_{12},\;and\;Bi_{12}GeO_{20}$ have been grown by Czo-chralski method using this auto-diameter control system.

  • PDF

Interference Fringe Signal Filtering Method for Performance Enhancing of White Light Interfrometry (가간섭 영역 외의 배경 잡음성 간섭무늬 신호 필터링을 통한 백색광 주사간섭계의 성능 향상)

  • Yim, Hae-Dong;Lee, Min-Woo;Lee, Seung-Gol;Park, Se-Geun;Lee, El-Hang;O, Beom-Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.5
    • /
    • pp.272-275
    • /
    • 2009
  • In order to enhance the background noise filtering performance of the white light interferometry(WLI), we demonstrate the noise filtering performance of preprocessing of the measured fringe signals. The WLI was realized through a mirau interferometer which was equipped with a green LED. When measuring large-height and rough surface objects, the illumination optics are considered the numerical aperture(NA) and the depth of focus(DOF). In this case, the limited NA of the illumination optics has a considerable impact on the interference fringe. Therefore, we propose a preprocessing method that uses the intensity difference between the measured intensity and the moving average intensity. The performance is demonstrated by measuring an array of metal solder balls fabricated on printed circuit board(PCB). The proposed method reduces the noise pixels by 15 percent.

Design of Vertical Type MEMS Probe with Branch Springs (분기된 구조를 갖는 수직형 MEMS 프로브의 설계)

  • Ha, Jung-Rae;Kim, Jong-Min;Kim, Byung-Ki;Lee, June-Sang;Bae, Hyeon-Ju;Kim, Jung-Yup;Lee, Hak-Joo;Nah, Wan-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.7
    • /
    • pp.831-841
    • /
    • 2010
  • The conventional vertical probe has the thin and long signal path that makes transfer characteristic of probe worse because of the S-shaped structure. So we propose the new vertical probe structure that has branch springs in the S-shaped probe. It makes closed loop when the probe mechanically connects to the electrode on a wafer. We fabricated the proposed vertical probe and measured the transfer characteristic and mechanical properties. Compared to the conventional S-shaped vertical probe, the proposed probe has the overdrive that is 1.2 times larger and the contact force that is 2.5 times larger. And we got the improved transfer characteristic by 1.4 dB in $0{\sim}10$ GHz. Also we developed the simulation model of the probe card by using full-wave simulator and the simulation result is correlated with measurement one. As a result of this simulation model, the cantilever probe and PCB have the worst transfer characteristic in the probe card.

The Concentrations of Endocrine Disrupter (PCBs and DDE) in the Serumand Their Predictors of Exposure in Korean Women (일부 한국 성인 여성들의 혈중 내분비계 장애물질 농도 및 그 노출요인의 연구)

  • 민선영;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.127-137
    • /
    • 2001
  • Polychlorinated biphenyls(PCBs) are halogenated aromatic compounds with the empirical formula $C_{12}$ $H_{10-n}$C $l_{n}$(n=1~10), and are a mixture of possible 209 different chlorinated congeners. PCBs were widely used as dielectric fluids for capacitors and transformers, plasticizers, lubricant inks and paint addirives. Once released into the environment, PCBs persist for years because they are so resistant to degradation. In addition to their persistence in the environment, PCBs in ecological food chains undergo biomagnification because of their high degree of lipophilicity. In 1970s, the worldwide production of PCBs was ceased and the import of PCBs was prohibited since 1983 in Korea. In spite of these actions, many PCBs seems to be still in use. The environmental load of PCBs will continue to be recycled through air, land, water, and the biosphere for decades to come. This study was conducted to measure the concentrations of PCBs in the serum samples of 112 women by GC/MSD and GC/ECD. The main results of this study were as follows. 1. PCBs were detected in all samples. The mean $\pm$SD levels of PCBs in the serum were 3.613$\pm$0.759 ppb, and median were 3.828 ppb. 2. The correlation coefficients of the concentrations of 13 PCB congeners were from minimum, 0.7913 to maximum, 0.9985, and all was significant(p=0.0001). The correlation coefficient between the concentrations of PCBs and p,p'-DDE was 0.9641(p=0.0001). 3. There was a positive association between age and PCBs' concentrations (simple linear regression ; $R^2$=0.86, $\beta$=0.08023, p<0.001). 4. There was a positive association between total lipids in the serum and PCBs' concentrations (simple linear regression ; $R^2$=0.7058, $\beta$=0.00486, p<0.001). 5. For possible predictors of PCBs and p,p' -DDE levels in the serum, age adjusted model (Y=$\beta$$_{0}$+$\beta$$_1$age+ $B_2$X) was applied. For BMI, major residential area, wether to eat caught fish by angling, where to eat caught fish by angling(by parents in the past), fish consumption, meat consumption, meat consumption, and dairy consumption, there was no association. For total conception frequency and lactation frequency and lactation period, there was negative association.ion.

  • PDF

Drop reliability evaluation of Sn-3.0Ag-0.5Cu solder joint with OSP and ENIG surface finishes (OSP.ENIG 표면 처리된 기판과 Sn-3.0Ag-0.5Cu 솔더 접합부의 낙하충격 신뢰성 평가)

  • Ha, Sang-Ok;Ha, Sang-Su;Lee, Jong-Bum;Yoon, Jeong-Won;Park, Jai-Hyun;Chu, Yong-Chul;Lee, Jun-Hee;Kim, Sung-Jin;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.1
    • /
    • pp.33-38
    • /
    • 2009
  • The use of portable devices has created the need for new reliability criterion of drop impact tests because of the tendency to accidentally drop in the use of these devices. The effects of different PCB surface finishes (organic solderability preservative (OSP) and electroless nickel immersion gold (ENIG)) and high temperature storage (HTS) test on the drop reliability were studied. Various drop test conditions were used to evaluate a drop reliability of assemblies to endure such impact and shock load. In the case of the as-reflowed samples (no HTS test), the SAC/OSP boards exhibited a better drop impact reliability than that of SAC/ENIG. However, the reverse was true if HTS test is performed. In addition, significant decrease of drop reliability was observed for both SAC/ENIG and SAC/OSP assemblies after HTS test. It was also observed that the thickness of intermetallic compound layer do play an important role in the brittle fracture of drop test.

  • PDF

The Effects of Physico-chemical Properties of soils on PCBs Analysis (토양의 이화학적 특성이 PCBs 분석에 미치는 영향)

  • Kim, Tae-Seung;Shin, Sun-Kyoung;Chang, Jun-Young
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.48-58
    • /
    • 2003
  • The effects of physico-chemical properties of soils on PCBs analysis in Korea was studied Three kinds of extraction solvents(toluene, acetone:hexane, dichloromethane) was selected to apply three different soils. The silicagel, florisil and alumina column cleanup also performed to compare the elution patterns, and three different methods (EPA, Japan, Proposed method in this study) of 62 PCBs also compared the individual peaks recoveries. The solvent average recovery was surveyed the order of toluene, acetone:hexane, dichloromethane as 77.94%, 58.59%, 54.20% for soil A, 53.65%, 80.32%, 68.27% for soil B and 44.52%, 60.35%, 56.36% for soil C, respectively. The average recovery was depended on the soil characters. The highest recoveries of each soil were obtained the toluene for soil A, acetone:hexane for soil B and C. However, the coplanar PCBs was obtained the highest recovery with dichloromethane. Thus, to select the solvent for the analysis of PCBs in solid, the selected compounds have to consider to get good result. The silicagel, florisil, alumina I and alumina II column cleanup process were surveyed the range of 38.73%~98.26%, and the higher chlorinated compounds was obtained the lower recovery compared to the low chlorinated compounds, generally. This results are also consistent with the coplanar PCBs isomers. The compared results of three different countries were obtained the 37.15% for USA, 45.92% for Japan and 44.46% for proposed method in this study.

For High Aspect Ratio of Conductive Line by Using Alignment System in Micro Patterning of Inkjet Industry (화상정렬 시스템을 이용한 잉크젯 반복인쇄기술)

  • Park, Jae-Chan;Park, Sung-Jun;Seo, Shang-Hoon;Joung, Jae-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.154-154
    • /
    • 2006
  • Samsung Electro Mechanics ink jet has developed ultra high resolution alignment system. The alignment system has been developed for repeatable printing of conductive ink. The resolution of alignment system is 0.5um and the velocity of printing working plate is 1.5m/s. So far repeated printing results included sintering process have over 30um of drop mislocation data. In order to improve line thickness and conductivity of metal line, we need to develop the higher mechanical accurate align system. On the demand, this developed align system has under $1{\sim}2{\mu}m$ mispositioning performance and can measure of mechanical accuracy of inkjet printer, as well as the straightness of jetted drop from inkjet head. There is no kinds limit of substrate and ink to use SEM alignment system. By using this alignment system, we progress two experiment of reiterate printing drop and making conductive line on the glass and photo paper. Optical microscope and 3D profiler has been used for measurement of printed ink.

  • PDF

Horizontal Distributions and Their Ecotoxicological Implications Relating to PCBs, DDTs, HCHs, and HCB in Sediments in the West Nakdong River (서낙동강 수계 퇴적물 내 PCBs, DDTs, HCHs 및 HCB의 수평적 분포와 잠재적 생태독성 영향 평가)

  • We, Sung-Ug;Yoon, Cho-Hee;Min, Byung-Yun
    • Journal of Life Science
    • /
    • v.22 no.3
    • /
    • pp.332-339
    • /
    • 2012
  • Horizontal distributions and their ecotoxicological implications relating to organochlorine compounds (OCs) were determined in surface sediments sampled from the West Nakdong River. The concentrations of polychlorinated biphenyls (PCBs), dichlorodiphenyltrichloroethanes (DDTs), hexachlorocyclohexanes (HCHs), and hexachlorobenzene (HCB) in surface sediments were in the range of 0.57-3.68, 0.41-8.35, 0.63-1.65, and n.d.-0.56 ng/g, respectively. DDTs represent the major OC in the West Nakdong River. Concentrations of PCBs and DDTs correlate with the total organic carbon (PCBs: r=0.874, p<0.001, and DDTs: r=0.762, p<0.05, respectively), indicating that organic content in the sediments is one of the major factors for influencing horizontal distribution of the organochlorine compounds in this river. Examining the potential poisonous character of the surface sediments to benthic organisms according to the sediment quality guideline (SQG), set out by the Canadian Council of Ministers of the Environment (CCME) and the National Oceanic and Atmospheric Administration (NOAA), we found that the concentrations of total PCBs, p,p'-DDD, and ${\gamma}$-HCH were lower than the effects range-low (ER-L) and the probable effects level (PEL). As a result, it is considered that the effect of organochlorines in the region considered on benthic organisms is very low from the perspective of environmental toxicology. However, in terms of the Canadian SQC, p,p'-DDE, p,p'-DDT, and total DDTs, respectively, exceeded the interim sediment quality guidelines (ISQG) and the threshold effect level (TEL) in 30%, 17%, and 19%, respectively, of the sediment samples analyzed.