• Title/Summary/Keyword: PC panel system

Search Result 66, Processing Time 0.024 seconds

The Development of PC based Panel Working Security System using Industrial Ethernet (산업용 Ethernet을 이용한 PC기반 패널작업 보안시스템 구축)

  • Song, Myung-Hyun;Park, Kyu-Nam;Han, Dong-Gi;Woo, Hyeok-Jae;Youm, Gyu-Il
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.2
    • /
    • pp.99-103
    • /
    • 2007
  • In this paper, one type of a security system for panel working is suggested. The industrial Ethernet is used for open-close door control of the working panel and for monitoring the working panel is correct or not. Especially to upgrade the security system, a remote approval function of panel working by using the given approval number, a remote monitoring function for checking the approved panel is currently working or not, and an alarming function for keying the unapproved number or opening the disapproved panel, are added for preventing and reducing the intentional working error. Also the worker and working time are stored in PC automatically in exel file for detecting the working error. To show the possibility of suggested security system. two-working panel system is prepared and studied.

A Study on Development of Automatic Welding System Using Panel PC (패널 PC를 이용한 자동 용접 시스템의 개발에 관한 연구)

  • Roh, Inh-Bae;Park, Jee-Ho;Shin, Dong-Ryul;Kim, Dong-Wan;Park, Han-Seok;Woo, Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.4
    • /
    • pp.183-189
    • /
    • 2004
  • In this paper, an automatic welding system is developed. In the developed system, an automatic welding system is remotely controlled by a portable panel PC. Additional, the DB system such as the operating condition and control data of automatic welding carriage is developed by ATMega128. Therefore, the developed system can overcome the restriction of operating condition, and reduce the weight of welding system and the risk of safety. The effectiveness of the developed system has been verified by the simulation and experimental results respectively.

Development of Automatic Welding DB System using Panel PC (패널 PC를 이용한 용접 자동화 DB 시스템의 개발)

  • Kim, D.W.;Park, J.H.;Shin, D.R.;Park, H.S.;Jung, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2284-2287
    • /
    • 2004
  • In this paper, an automatic welding DB system using a panel PC is developed. In the developed system, a automatic welding system is remotely controlled to overcome the restriction of operating condition by a portable panel PC, and the DB system such as the operating condition and control data of automatic welding carriage is developed by ATMega128.

  • PDF

An Application of Precast Concrete System for Steel Framed Residential Buildings and PC Framed System for Parking Structure (철골조 아파트의 PC 공법 적용성 및 지하주차장의 골조 PC 공법)

  • 김영수;김정연;임인혁;김두영;장월선
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.903-910
    • /
    • 2000
  • Because the construction type SFRB is completely different in comparison with that of RC apartment the construction and work process, which are currently used, have to be changed. The main purpose of study is to analyze the difficulties of this construction and to apply the technology for other construction area. In this study, it is investigated to the problems of construction for SFRB and the construction method of PC panel fabricated on SFRB in Yongin goosng. Later, it is estimated prefabricated method had an great effect on PC panel System as lower cost and shorter schedule in SFRB. The Precast concrete framed System has many merit than the reinforced concrete structures system at constructability, structural safety and quality, therefore, it will be widely applied at parking structure in the future.

  • PDF

Development of Rerofitting System for the Remodeling of Reinforced Concrete Frame Using High Ductile Fiber Composite Mortar PC Panel (고인성섬유 복합모르타르 PC판넬을 활용한 철근콘크리트 골조의 리모델링을 위한 보강시스템 개발)

  • Ha, Gee-Joo;Shin, Jong-Hak;Kim, Yun-Yong;Hong, Kun-Ho;Yang, Seung-Hyeok;Kim, Jin-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.66-69
    • /
    • 2006
  • Three reinforced concrete rigid frames and infilled rigid frames with new retrofitting system were tested under both vertical and cyclic loadings, Experimental programs were carried out to evaluate and improve the seismic performance of such test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. under load reversals. All the specimens were modeled in one-third scale size. For specimens(RFHPC, RFAR) designed by the improving of seismic performance of the rigid frame using the high ductile fiber composite PC panel and ALC panel system, load-carrying capacities were increased $1.45{\sim}2.28$ times, and hysteretic behavior was very stable during the final tests in comparison with the standard specimen(SRF).

  • PDF

A Experimental Study on Structural Behavior of Hybrid Precast Concrete Panel (복합 프리캐스트 콘크리트 패널의 구조 거동에 대한 실험적 연구)

  • Lee, Sang-Sup;Park, Keum-Sung
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.9
    • /
    • pp.11-18
    • /
    • 2018
  • As the height of the modular buildings increases, their stability becomes more and more dependent on the core. All traditional construction methods in structural concrete and steel can be utilized for cores in modular buildings but a core system with dry connection is more desirable to complete a greater degree of factory finish and faster erection of modular buildings. In order to do that, the hybrid PC(precast concrete) panel, which has a pair of C-shaped steel beams combined at the top and bottom of a concrete wall, was developed, In this study the cyclic lateral loading test on the hybrid PC panel is carried out and the panel configurations are examined to enhance the structural performance in comparison with the RC wall. Experimental results show that the strength of hybrid PC panel is about 70% of thar ot RC wall and the anchorage of vertical reinforcing bar welded to C-shaped steel beam needs to be improved.

Development of the Integrated Monitoring System for Panel boards (분전반 통합 감시 시스템 개발)

  • Kim, Il-Kwon;Cho, Hyun-Kyung;Lee, Dong-Zoon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.347_348
    • /
    • 2009
  • In this paper, we described the integrated monitoring system for low-voltage panel boards. This system consists of three parts, a panel board controller, an integrated monitoring unit and a remote PC. The panel board controller which was made of CT/PT unit, control unit and power supply is able to transmit variable parameter for monitoring and diagnosis of low voltage branch circuits. Also, the integrated monitoring unit was collected monitoring data from panel boards and displayed on the touch panel.

  • PDF

Development of Hybrid Panel with C-shaped Steel Beam at Top and Bottom of Precast Concrete Wall (프리캐스트 콘크리트 벽체의 상하부에 C형강 보가 결합된 복합 패널의 개발)

  • Lee, Sang Sup;Park, Keum Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.6
    • /
    • pp.435-442
    • /
    • 2017
  • A lateral load resisting system is a necessary structural element for the mid- to high-rise modular buildings and concrete cores are known as the most typical lateral load resisting systems in 10- to 20-story modular buildings. It is difficult to construct a concrete core simultaneously with the installation and finishing work of modular units because concrete placed using wet methods might contaminate or destroy the modular unit. Therefore, we have developed a hybrid PC (precast concrete) panel construction method that can construct a concrete core together with the installation of modular units. The hybrid PC panel is a load-bearing element in which a pair of C-shaped beams are combined at the top and bottom of a concrete wall. Concrete cores can be constructed by dry method to connect the hybrid PC panels with bolts. In this study, the details and connection of hybrid PC panels are improved to have the lateral performance comparable to reinforced concrete structural walls and are verified through FE analysis.

The measurement of three-dimensional temporal behavior according to the pressure in the plasma display panel (플라즈마 디스플레이 패널의 압력별 3차원 시간 분해 측정)

  • Kim, Son-Ic;Choi, Hoon-Young;Lee, Seok-Hyun;Lee, Seung-Gol
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1628-1630
    • /
    • 2002
  • In this paper, we measured 3-dimensional temporal behavior of the light emitted from discharge cell of plasma display panel(PDP) as a function of the pressure using the scanned point detecting system. The detected light signal through the PM tube is sent on the oscilloscope and oscilloscope which is connected to PC with GPIB. The whole system is controlled by a PC. From the temporal behavior results, we could analyze the discharge behavior of panel with Ne-Xe(4%) mixing gas and 300torr, 400torr, 500torr pressure. The top view of panel shows that the discharge moves from inner edge of cathode electrode to outer cathode electrode forming arc type. At the 300torr, initial emission time is very fast. The side view of panel shows that the light is detected up to $150{\mu}m$ height of barrier rib. In the panel of 300torr, emission distribution is wider than the others.

  • PDF

Monolithic Ambient-Light Sensor System on a Display Panel for Low Power Mobile Display (저 전력 휴대용 디스플레이를 위한 패널 일체형 광 센서 시스템)

  • Woo, Doo Hyung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.48-55
    • /
    • 2016
  • Ambient-light sensor system, which changes the brightness of a display as ambient light change, was studied to reduce the power consumption of the mobile applications such as note PC, tablet PC and smart phone. The ambient-light sensor system should be integrated on a display panel to improve the complexity and cost of mobile applications, so the ambient-light sensor and readout circuit was integrated on a display panel using low-temperature poly-silicon thin film transistors (LTPS-TFT). We proposed the new compensation method to correct the panel-to-panel variation of the ambient-light sensors, without additional equipment. We designed and investigated the new readout circuit with the proposed compensation method and the analog-to-digital converter for the final digital output of ambient light. The readout circuit has very simple structure and control timing to be integrated with LTPS-TFT, and the input luminance ranges from 10 to 10,000 lux. The readout rate is 100 Hz, and maximum differential non-uniformity with 20 levels of the final output below 0.5 LSB.