• 제목/요약/키워드: PC monitoring

검색결과 563건 처리시간 0.035초

Utilizing Metaverse for Bidirectional Coding Education (양방향 코딩 교육을 위한 메타버스 활용 방안)

  • Lee, Seung Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제26권2호
    • /
    • pp.288-293
    • /
    • 2022
  • Recently, metaverse is becoming increasingly important in coding education. One of the most important elements in metaverse is interaction in 3D virtual space. However, most existing education methods still utilize metaverse for unidirectional education without making use of interaction. This paper proposes a new method of using metaverse for bidirectional coding education. In the metaverse virtual space, a professor and students are able to share their PC screens for monitoring purposes. Also, once a student sends a request to the professor, the professor can immediately provide proper feedback (such as source codes correction) through access control. This metaverse virtual space is able to include more than two professors that allows for a many-to-many coding education. This paper presents a way of constructing the metaverse environment and teaching scenario, followed by the descriptions of the advantages and requirements for the proposed method.

Posture Correction Guidance System using Arduino (아두이노를 활용한 자세교정 유도 시스템)

  • Kim, Donghyun;Kim, Jeongmin;Bae, Woojin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2021년도 춘계학술대회
    • /
    • pp.369-372
    • /
    • 2021
  • These days, people spend more time sitting at a desk for studies or work. Also, because people continue to use computers, smartphones, and tablet PCs often during break times, their posture is getting worse. Maintaining a position of bad posture for an extended period of time causes problems with the musculoskeletal system related to the neck, shoulders, and spine. Additionally, problems such as physical fatigue and posture deformation are predicted to expand to a wide range of age groups. Therefore, the core function of the system we are developing is to ensure correct sitting posture and to receive alert notifications via the created mobile application. To create the system, a flex sensor, pressure sensor, and tilt sensor are attached to a chair and utilized. The flex sensor detects and compares the amount of bending in the chair's posture and transmits this value to an Arduino Uno R3 board. Additionally, information such as body balance and incline angle are collected to determine whether or not the current sitting posture is correct. When the posture is incorrect, a notification is sent through the mobile application to indicate to the user and the monitoring app that their posture is not correct. The system proposed in this study is expected to be of great help in future posture-related research.

  • PDF

Relationship Between Exercise Induced Asthma and Gastroesophageal Reflux (운동유발성 천식과 위식도역류와의 연관성)

  • Lee, Heung-Bum;Lee, Yang-Deok;Kim, Hyun-Chul;Lee, Yong-Chul;Lee, Soo-Teik;Rhee, Yang-Keun
    • Tuberculosis and Respiratory Diseases
    • /
    • 제48권2호
    • /
    • pp.203-209
    • /
    • 2000
  • Background: Exercise is a very common precipitant of asthma. Bronche-constriction associated with exercise can occur in 75~90% of individuals with asthma The estimated prevalence(30~85%) of gastroesophageal reflux(GER) in patients with asthma is significantly higher than in general population. We performed pH monitoring during the exercise in order to evaluate whether exercise induced asthma(EIA) could be related to GER and acid reflux-induced esophagobronchial reflex-mediated bronchospasm might be a factor for EIA. Method: Following an overnight fast, 18 patients with a suspected EIA(6 men, 12 women) were studied. Monitoring of intraesophageal pH, ECG and spirometry was done for 1 hour before treadmill exercise. After baseline monitoring, subjects underwent symptom-limited treadmill exercise with Bruce protocol and continuous monitoring for 60 min after exercise. Spirometry was done at baseline prior to exercise, and repeated every 10 min after full exercise for 60 min. Results: Exercise-induced bronchoconstriction was noted in 15 patients, who performed MBPT and 12 patients confirmed for bronchial asthma and 3 patients were diagnosed exercise-induced astham. Five of 15 EIA patients demonstrated a pathologic degree of GER. Conclusion: We suggest that GER may be one of pathophysiologic factors of EIA and evoke further concentration on the GER in the EIA patients.

  • PDF

Real-time monitoring for blending uniformity of trimebutine CR tablets using near-infrared and Raman spectroscopy (근적외분광분석법과 라만분광분석법을 이용한 트리메부틴말레인산 서방정의 혼합 과정 모니터링)

  • Woo, Young-Ah
    • Analytical Science and Technology
    • /
    • 제24권6호
    • /
    • pp.519-526
    • /
    • 2011
  • Chemometrics using near-infrared (NIR) and Raman spectroscopy have found significant uses in a variety quantitative and qualitative analyses of pharmaceutical products in complex matrixes. Most of the pharmaceutical can be measured directly with little or no sample preparation using these spectroscopic methods. During pharmaceutical manufacturing process, analytical techniques with no or less sample preparation are very critical to confirm the quality. This study showed NIR and Raman spectroscopy with principal component analysis (PCA) was very effective for the blending processing control. It is of utmost importance to evaluate critical parameters related to quality of products during pharmaceutical processing. The blending is confirmed by off-line determination of active pharmaceutical ingredient (API) by a conventional method such as high performance liquid chromatography (HPLC) and UV spectroscopy. These analytical methods are time-consuming and ineffective for real time control. This study showed the possibility for the determination of blend uniformity end-point of CR tablets with the use of both NIR and Raman spectroscopy. The samples were acquired from six positions during blending processing with U-type blender from 0 to 30 min. Using both collected NIR and Raman spectral data, principal component analysis (PCA) was used to follow the uniformity of blending and finally determine the end-point. The variation of homogeneity of six samples during blending was clearly found and blend uniformity end-point was successfully confirmed in the domains of principal component (PC) scores.

A DESIGN AND DEVELOPMENT OF MULTI-PURPOSE CCD CAMERA SYSTEM WITH THERMOELECTRIC COOLING II. SOFTWARE (열전냉각방식의 범용 CCD 카메라 시스템 개발 II. 소프트웨어)

  • Oh, S.H.;Kang, Y.W.;Byun, Y.I.
    • Journal of Astronomy and Space Sciences
    • /
    • 제24권4호
    • /
    • pp.367-378
    • /
    • 2007
  • We present a software which we developed for the multi-purpose CCD camera. This software can be used on the all 3 types of CCD - KAF-0401E ($768{\times}512$), KAF-1602E ($1536{\times}1024$), KAF-3200E ($2184{\times}1472$) made in KODAK Co.. For the efficient CCD camera control, the software is operated with two independent processes of the CCD control program and the temperature/shutter operation program. This software is designed to fully automatic operation as well as manually operation under LINUX system, and is controled by LINUX user signal procedure. We plan to use this software for all sky survey system and also night sky monitoring and sky observation. As our results, the read-out time of each CCD are about 15sec, 64sec, 134sec for KAF-0401E, KAF-1602E, KAF-3200E., because these time are limited by the data transmission speed of parallel port. For larger format CCD, the data transmission is required more high speed. we are considering this control software to one using USB port for high speed data transmission.

DESIGN AND IMPLEMENTATION OF HITL SIMULATOR COUPLEING COMMUNICATIONS PAYLOAD AND SOFTWARE SPACECRAFT BUS (통신탑재체와 소프트웨어 위성버스체를 통합한 HITL 시뮬레이터의 설계 및 구현)

  • 김인준;최완식
    • Journal of Astronomy and Space Sciences
    • /
    • 제20권4호
    • /
    • pp.339-350
    • /
    • 2003
  • Engineering qualification model payload for a communications and broadcasting satellite(CBS) was developed by ETRI from May, 2000 to April, 2003. For. the purpose of functional test and verification of the payload, a real-time hardware-in-the-loop(HITL) CBS simulator(CBSSIM) was also developed. We assumed that the spacecraft platform for the CBSSIM is a geostationary communication satellite using momentum bias three-axis stabilization control technique based on Koreasat. The payload hardware is combined with CBSSIM via Power, Command and Telemetry System(PCTS) of Electrical Ground Support Equipment(EGSE). CBSSIM is connected with PCTS by TCP/IP and the payload is combined with PCTS by MIL-STD-1553B protocol and DC harness. This simulator runs under the PC-based simulation environment with Windows 2000 operating system. The satellite commands from the operators are transferred to the payload or bus subsystem models through the real-time process block in the simulator. Design requirements of the CBSSIM are to operate in real-time and generate telemetry. CBSSIM provides various graphic monitoring interfaces and control functions and supports both pre-launch and after-launch of a communication satellite system. In this paper, the HITL simulator system including CBSSIM, communications payload and PCTS as the medium of interface between CBSSIM and communications payload will be described in aspects of the system architecture, spacecraft models, and simulator operation environment.

IoT Open-Source and AI based Automatic Door Lock Access Control Solution

  • Yoon, Sung Hoon;Lee, Kil Soo;Cha, Jae Sang;Mariappan, Vinayagam;Young, Ko Eun;Woo, Deok Gun;Kim, Jeong Uk
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제12권2호
    • /
    • pp.8-14
    • /
    • 2020
  • Recently, there was an increasing demand for an integrated access control system which is capable of user recognition, door control, and facility operations control for smart buildings automation. The market available door lock access control solutions need to be improved from the current level security of door locks operations where security is compromised when a password or digital keys are exposed to the strangers. At present, the access control system solution providers focusing on developing an automatic access control system using (RF) based technologies like bluetooth, WiFi, etc. All the existing automatic door access control technologies required an additional hardware interface and always vulnerable security threads. This paper proposes the user identification and authentication solution for automatic door lock control operations using camera based visible light communication (VLC) technology. This proposed approach use the cameras installed in building facility, user smart devices and IoT open source controller based LED light sensors installed in buildings infrastructure. The building facility installed IoT LED light sensors transmit the authorized user and facility information color grid code and the smart device camera decode the user informations and verify with stored user information then indicate the authentication status to the user and send authentication acknowledgement to facility door lock integrated camera to control the door lock operations. The camera based VLC receiver uses the artificial intelligence (AI) methods to decode VLC data to improve the VLC performance. This paper implements the testbed model using IoT open-source based LED light sensor with CCTV camera and user smartphone devices. The experiment results are verified with custom made convolutional neural network (CNN) based AI techniques for VLC deciding method on smart devices and PC based CCTV monitoring solutions. The archived experiment results confirm that proposed door access control solution is effective and robust for automatic door access control.

Effects of Lycopene on Endothelial Protein C Receptor Shedding In Vitro and In Vivo (In vitro와 in vivo에서 라이코펜이 EPCR 탈락에 미치는 영향)

  • Yoo, Hayoung;Lee, Hyun-Shik;Lee, Wonhwa;Bae, Jong-Sup
    • Journal of Life Science
    • /
    • 제23권5호
    • /
    • pp.650-656
    • /
    • 2013
  • Endothelial protein C receptor (EPCR) plays a pivotal role in augmenting Protein C activation through the thrombin-thrombomodulin complex. EPCR activity is markedly changed by ectodomain cleavage and released as the soluble protein (sEPCR). EPCR shedding is mediated by tumor necrosis factor-${\alpha}$ converting enzyme (TACE). Lycopene found in tomatoes and tomato products has anti-oxidant, anti- cancer and anti-inflammatory effects. However, little is known about the effects of lycopene on EPCR shedding. We investigated this issue by monitoring the effects of lycopene on the phorbol-12-myristate 13-acetate (PMA), tumor necrosis factor (TNF)-${\alpha}$, interleukin (IL)-$1{\beta}$ and on the cecal ligation and puncture (CLP)-mediated EPCR shedding. Data showed that lycopene potently inhibited the PMA, TNF-${\alpha}$, IL-$1{\beta}$ and CLP-induced EPCR shedding by suppressing TACE expression. Furthermore, lycopene reduced PMA-stimulated phosphorylation of p38, extracellular regulated kinases (ERK) 1/2 and c-Jun N-terminal kinase (JNK). Given these results, lycopene should be viewed as a candidate therapeutic agent for the treatment of various severe vascular inflammatory diseases via inhibition of the EPCR shedding.

Usability Testing of Digital Pressure Bio-feedback for Spinal Rehabilitation Exercise (척추재활운동을 위한 디지털 압력바이오피드백 장치의 사용성 평가)

  • Kim, Tea-Ho;Oh, Do-Bong;Kim, Da-Yeon
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • 제11권3호
    • /
    • pp.119-126
    • /
    • 2017
  • In the clinical setting, the pressure bio-feedback device is used for the spinal rehabilitation of patients with back pain, but it has several disadvantages. The purpose of this study was to develop a digitalized pressure biofeedback system that provides precise exercise method and posture in real time during the spinal rehabilitation exercise by sensing and monitoring body movements and balance of users and providing biofeedback to users. After that, the usability testing for a digitalized pressure biofeedback system will be conducted to identify problems such as safety, performance, operability, and satisfaction, and suggest improvement directions. A total of 33 subjects were participated in the usability testing. The experts group and the users group evaluated the developed digitalized pressure biofeedback system on a scale of 5 points after using the equipment. In the user group, safety was 3.59, operability was 4.38, satisfaction was 4.49. In the expert group, safety was 2.86, operability was 3.91, and performance was 4.28. Based on the usability evaluation, if the problems of stability of the cradle for tablet PC, air injection, screen display, etc. are solved, it becomes a exercise device capable of accurately exercising and evaluating the function of the spine by checking its own motion state while the spinal stabilization exercise.

Development and application of stent-based image guided navigation system for oral and maxillofacial surgery (구강외과 수술용 스텐트 기반 영상유도 수술 시스템의 개발)

  • Lee, Woo-Jin;Kim, Dae-Seung;Yi, Won-Jin;Lee, Sam-Sun;Choi, Soon-Chul;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Myung-Jin;Lee, Jee-Ho
    • Imaging Science in Dentistry
    • /
    • 제39권3호
    • /
    • pp.149-156
    • /
    • 2009
  • Purpose : The purpose of this study was to develop a stent-based image guided surgery system and to apply it to oral and maxillofacial surgeries for anatomically complex sites. Materials and Methods : We devised a patient-specific stent for patient-to-image registration and navigation. Three-dimensional positions of the reference probe and the tool probe were tracked by an optical camera system and the relative position of the handpiece drill tip to the reference probe was monitored continuously on the monitor of a PC. Using 8 landmarks for measuring accuracy, the spatial discrepancy between CT image coordinate and physical coordinate was calculated for testing the normality. Results : The accuracy over 8 anatomical landmarks showed an overall mean of $0.56{\pm}0.16\;mm$. The developed system was applied to a surgery for a vertical alveolar bone augmentation in right mandibular posterior area and possible interior alveolar nerve injury case of an impacted third molar. The developed system provided continuous monitoring of invisible anatomical structures during operation and 3D information for operation sites. The clinical challenge showed sufficient accuracy and availability of anatomically complex operation sites. Conclusion : The developed system showed sufficient accuracy and availability in oral and maxillofacial surgeries for anatomically complex sites.

  • PDF