• Title/Summary/Keyword: PC interface

Search Result 810, Processing Time 0.027 seconds

Implementation of FOUNDATION Fieldbus Interface Board (FOUNDATION 필드버스 인터페이스 보드 구현)

  • 최인호;홍승호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.93-93
    • /
    • 2000
  • In this study, physical and data link layer protocols of FOUNDATION Fieldbus are implemented. INTEL386EX and 80196KC are used fer the CPU of PC interface board and sensor interface module, respectively The physical layer protocol of FOUNDATION Fieldbus is developed by using FB3050 chip, the fieldbus communication controller ASIC. The data Link layer protocol of FOUNDATION Fieldbus is implemented by software.

  • PDF

Design of PC-based CR-PACS using Multiresolution Wavelet Transform (다해상도 웨이블릿 변환을 이용한 PC기반의 CR-PACS 설계)

  • 김광민;유선국
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.305-312
    • /
    • 1998
  • A small PACS based on PC is designed for CR. To receive the digital image from CR, a DICOM Interface Unit (DIU) is designed that complied with the medical image standard, DICOM V3.0. The CR images acquired through the DIU are stored in a file-server; the patient information of the images is stored in a database. To improve the performance of PC and to use it easily, multiresolution images are constructed by wavelet transform and displayed progressively. Wavelet compression method is newly adopted to store the images hierarchically to storage units. In this compression method, the image is decomposed into subclasses of image by wavelet transform, and then the subclasses of the image are vector quantized using a multiresolution codebook. The storage units for CR images were divided into the short-term storage in file-server and the harddisk in viewing station. Image processing tools supported by general PACS is implemented based on PC.

  • PDF

PLD Design of LCD Drive Circuit using PC Interface (PC 인터페이스를 이용한 LCD 구동회로의 PLD 설계)

  • Lee, Seung-Ho;Lee, Joo-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2002
  • This paper presents a PLD design of Gray Mode Graphic STN LCD drive circuit using PC interface. The proposed LCD drive circuit doesn\`t use microprocessor for the convenience of users. Thus, the LCD drive circuit can transfer efficiently image data created under PC to LCD. The LCD drive circuit which is modelled in schematic capture, AHDL and VHDL is simulated in functionally through the use of ALTERA MAX+PLUS II. Also, timing simulation is performed by ALTERA EPM7192SQC160-15 PLD implementation. The PC interface part have been programmed in MS-Visual C++ 6.0. The validity and efficiency of the proposed LCD drive circuit have been verified by test board. After comparing this LCD drive circuit to specify it was verified that the developed LCD drive circuit showed good performances, such as convenience of users, low cost.

Man-Machine Interface Device for Dismantling Factory

  • Yi, Hwa-Cho;Park, Jung-Whan;Park, Myon Woong;Nam, Taek-Jun
    • Clean Technology
    • /
    • v.23 no.3
    • /
    • pp.248-255
    • /
    • 2017
  • In dismantling factories for recycling, it is important to input actual working data to a personal computer (PC) in order to monitor the work results and related recycling rate of the inputs. This should be performed with a keyboard, a mouse, or other devices. But when a worker is working in the factory, it could be bothersome or time consuming to go to the PC. Especially, workers who works at dismantling factories have a generally low education level are scared to use a PC, which could be used as a pretext for not using the PC. In some cases, data input is performed by a worker after the day's job. In this case, it could take additional time, the worker can make more mistakes, and the data could be unreliable. In this study, we developed a man-machine interface (MMI) device using a safety helmet. A joystick-like device, pushbuttons, and a radio frequency (RF) device for wireless communication is equipped in a safety helmet. This MMI device has functions similar to a PC mouse, and it has a long communication distance. RF is used because it consumes less battery power than Bluetooth. With this MMI device, workers need not go to a PC to input data or to control the PC, and they can control the PC from a long distance. The efficiency of PCs in a factory could be increased by using the developed MMI system, and workers at the dismantling factories could have less reluctance in using the PC.

A VIA-based RDMA Mechanism for High Performance PC Cluster Systems (고성능 PC 클러스터 시스템을 위한 VIA 기반 RDMA 메커니즘 구현)

  • Jung In-Hyung;Chung Sang-Hwa;Park Sejin
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.11
    • /
    • pp.635-642
    • /
    • 2004
  • The traditional communication protocols such as TCP/IP are not suitable for PC cluster systems because of their high software processing overhead. To eliminate this overhead, industry leaders have defined the Virtual Interface Architecture (VIA). VIA provides two different data transfer mechanisms, a traditional Send/Receive model and the Remote Direct Memory Access (RDMA) model. RDMA is extremely efficient way to reduce software overhead because it can bypass the OS and use the network interface controller (NIC) directly for communication, also bypass the CPU on the remote host. In this paper, we have implemented VIA-based RDMA mechanism in hardware. Compared to the traditional Send/Receive model, the RDMA mechanism improves latency and bandwidth. Our RDMA mechanism can also communicate without using remote CPU cycles. Our experimental results show a minimum latency of 12.5${\mu}\textrm{s}$ and a maximum bandwidth of 95.5MB/s. As a result, our RDMA mechanism allows PC cluster systems to have a high performance communication method.

Development of a Hydraulic Leading System Real-Time Simulator Using a PC and I/O Interface Board (PC 와 I/O 인터페이스 보드를 이용한 유압식 하역장치의 실시간 모의시험기 개발)

  • Lee, Seong-Rae
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.426-432
    • /
    • 2000
  • The hydraulic loading system real-time simulator using a PC and I/O interface board is developed to simulate the dynamic characteristics of hydraulic loading system in real time. The simulator receives the digital on-off control signals generated by the operator through the D/I channels, updates the state and output variables of the hydraulic loading system responding to the input signals and draw the moving pictuters of the lift cylinder, lift arm and loading box on the PC monitor in real time. Also, the operator can observe the displacement and pressure of cylinder, the rotatinal angle, reaction force, and safety factors of lift arm representing the operation of hydraulic loading system through the PC monitor in real time. The real-time simulator can be a very useful tool to design industrial dynamic systems and feel the goodness of the system operation since the operator can observe the moving pictures of the operating system in real time as he operates the real time simulator.

  • PDF

High-Speed Signaling in SDARM Bus Interface Channels : Review

  • Park, Hong-June;Sohn, Young-Soo;Park, Jin-Seok;Bae, Seung-Jun;Park, Seok-Woo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.1
    • /
    • pp.50-69
    • /
    • 2001
  • Three kinds of high-speed signaling methods for synchronous DRAM (SDRAM) bus interface channels (PC-133, Direct-Rambus, and SSTL-2) were analyzed in terms of the timing budget and the physical transmission characteristics. To analyze the SDRAM bus interface channels, loss mechanisms and the effective characteristic impedance method were reviewed and the ABCD matrix method was proposed as an analytic and yet accurate method. SPICE simulations were done to get the AC responses and the eye patterns of the three SDRAM bus interface channels for performance comparisons. Recent progress and future trend for SDRAM bus interface standards were reviewed.

  • PDF

Implementation of Internet Telephone of Phone-to-PC Type (Phone-to-PC 방식의 인터넷 전화 구현)

  • 최용훈;박준석고대식
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.122-125
    • /
    • 1998
  • 본 논문에서는 인터넷텔레포니 인터페이스(Internet Telphone Interface)를 제작하고 자체 개발된 PC-to-PC 방식의 인터넷 전화 소프트웨어인 Realphone을 이용하여 Phone-to-PC 방식의 인터넷 전화를 구현하였다. 실험을 위하여 인터넷텔레포니 인터페이스를 제작하였으며, 펜티엄 PC 2대와 일반 상용화 되어있는 전화기를 사용하였다. 통화는 목원대학교 학내전화와 목원대학교내 LAN으로 연결된 PC사이에 로컬(Local)상황과 국내 교육망으로 연결된 목원대학교와 서울대학교 사이에 트래픽이 서로 다른 새벽(Unload), 오전(Mid-load), 오후(Load)에 이루어졌다. 실험을 통하여 대형 게이트웨이의 도움없이 간단한 인터페이스만으로 Phone-to-PC 방식 인터넷전화의 통화가 가능함을 확인하였다.

  • PDF

Development of the brain stimulator for stroke patients via ZigBee technology and user-friendly, graphical user-interface based software for controlling stimuli on PC (ZigBee를 이용한 뇌졸중 환자용 뇌자극기 개발과 PC 기반 자극 제어용 사용자 인터페이스 개발)

  • Kim, G.H.;Yang, Y.S.;Lee, S.M.;Kim, N.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.33-35
    • /
    • 2006
  • We studied the prototypal developments of Plastic Cortex Stimulator (PCS) for stroke patients. The PC sends the stimulation parameters (amplitude, pulse width, cycle, etc.) to the transmitter ZigBee module through serial port. The receiver ZigBee module generates stimulation waveform. The generated output can be controlled by the PC program. Further study can be expanded to portable handset such as PDA using ZigBee. The wireless control of PCS with the handset can help the tele-rehabilitation.

  • PDF

Interface Conversion to Extend Communication Cable of Ultrasonic Sensor (초음파 센서 통신선 연장을 위한 인터페이스 변환)

  • Seo, Dae-Il;Kwon, Byung-Hyuk;Kim, Sang-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.467-472
    • /
    • 2022
  • The 3D ultrasonic anemometer transmits measured data by connecting PC and RS232C interface. Depending on the observation location, it is often necessary to extend the cable connecting the PC and the sensor. When installing on the test bed of the Air Meteorological Agency, the original AWM2919 cable was required to be extended because the distance between the PC container and the equipment installation site was more than 30 m. The cable was extended through a process such as extending the AWM2919 cable, converting the interface with the PC from RS232C to RS485, and testing the RS485 communication. After the equipment was installed with an extended cable, data were remotely collected and analyzed to confirm successful cable extension.