• Title/Summary/Keyword: PC 공사

Search Result 111, Processing Time 0.026 seconds

Development of Non-Shrink Mortar Grouting Type Splice Sleeve (무수축 모르타르 충진형 슬리브 개발)

  • Lee, Young-Ho;Song, Jae-Joon;Cho, Jae-Young;Kim, Do-Hak
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.67-73
    • /
    • 2011
  • This study aims to develop an economical precast hollow concrete column with high constructability which consists of only splice sleeve and general reinforcing bar without using PC tendons in order to reduce the construction period and cost. With this purpose, this study performed the finite element analysis and tension test by using some variables such as length of sleeve, diameter of rebar and curing method for suggesting a grouting type splice sleeve which is a new type joint rebar and developing an optimized splice sleeve. As a result, the analysis on the tension performance of splice sleeve did not show any destruction caused by pull-out in reinforcing bar but it only occurred destruction of tension bar or bolt shear rupture from the mechanical defect of sleeve. Therefore, the experiment showed high performance in tension of the suggested splice sleeve and verified the application of precast hollow concrete column.

Measurement and Control of Ground Vibrations due to Precast Concrete Pile-driving by Diesel Hammer (디젤해머에 의한 콘크리트말뚝 항타시(抗打時) 발생(發生)되는 지반진동(地盤振動)의 측정(測定) 및 영향평가(影響評價))

  • Park, Yean Soo;Chon, Chun Su
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.9 no.1
    • /
    • pp.71-78
    • /
    • 1989
  • This Paper measures and analyzes ground vibrations induced during precast concrete pile-driving using diesel hammer at radii varying from 9m to 30m to evaluate effects of such vibrations associated with deep foundation piling operations near the residential of commercial areas. From this study, characteristics for attenuation and frequency of the vibrations casued by pile-driving are established and the empirical equation for predicting peak velocity and acceleration levels are obtained. This equation can be used to predict the peak vibration levels and select the appropriate hammers for future projects where similar soil conditions to this test site are encountered.

  • PDF

Database System of Noise and Vibration Criteria (소음진동 허용기준 DATABASE SYSTEM 개발)

  • 김경면
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.04a
    • /
    • pp.70-75
    • /
    • 1994
  • 소음진동은 최근 사회적 인식이 변함에 따라 환경관련 민원 중에서 가장 많은 건수의 민원이 발생되는 요소로서 제저업체, 건설업체등의 기업 뿐만 아니라 국토개발, 도시개발을 담당하는 정부 기관 등에서 각종 업무를 수행하는데 중요한 고려대상이 되고 있다. 소음진동이 충분히 저감되지 않은 가전제품은 소비자들에게 외면당하고 민원이 발생된 건설 공사현장에서의 피해 보상금은 기업이 원가부담으로 작용되며 그 사업주체가 정부일 경우는 행정업무 처리에 지장을 초래하게 된다. 소음진동 문제를 해결하는데 가장 우선적으로 필요한 요소는 소음진동 허용기준을 적절히 산정하는 것이다. 소음진동은 발생원인이 매우 다양하며 소음진동에 노출되는 사람(혹은 건축물, 정밀기계 등)의 상대적인 위치(사회 문화적인)에 따라 피해 정도가 다르기 때문에 각국의 정부나 각종 사회단체, 기업은 독특한 국민성, 지역성, 사회개발 정도 등에 따라 적절한 허용기준을 제시하고 있다. 소음진동 문제를 해결해야 할 담당자들은 이러한 모든 여건을 고려하여 현재 상황에서 가장 적절한 허용기준을 설정하고 소음진동 저감 대책을 수립하여야 한다. 본 연구에서는 설계자나 공장관리자, 건설 현장의 관리자들이 소음진동 문제에 직면 했을 때 신속히 적절한 허용기준을 산정한 후 소음진동 대책을 수립할 수 있도록 국내의 주요 소음진동 허용기준을 수립하여 데이타베이스화 하고 이를 PC통신으로 이용가능하게 하는 NVC-DS(Noise and Vibration Criteria-Database System)을 개발하였다.

  • PDF

A Construction of HA System that introduce Home Network of PLC base in existing environment (PLC 기반의 Home Network를 기존환경에 바로 도입 가능한 Home Automation System 연구)

  • Shin Kyung-Chul;Oh Young-Sun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2005.05a
    • /
    • pp.320-328
    • /
    • 2005
  • Government is supporting development of home networking. But, this new system is much expensive to introduce in the home. And limit for establishment is so many in the home. Therefore, in this paper, Present direction of home automation system that can have high efficiency into low expense, induction of automation system is easied in the home. Also, install can be easy and do remote control in PC, HP, PDA because use PLC or HN RF, DB.

  • PDF

The Slope Stability Establishment with P.C. Anchoring Method (P.C. Anchoring 공법을 활용한 사면안정대책)

  • 박철숙;손재호;인영길;장두희
    • Proceedings of the KSEG Conference
    • /
    • 2002.04a
    • /
    • pp.61-73
    • /
    • 2002
  • Daegok dam is Concrete Face Rockfill Dam(C.F.R.D) of which 52m height, 190m length, that construction in beneath 306, Chanjeon-Ri, Dudong-Myeon, Ulju-Gun, Ulsan Metrocity. Left slope excavation of spillway have related to Daegok dam construction are developing crack in Sta. No. 1~2, EL. 134~137m after 67.0mm rainfall from 2000. 7. 23. 13:00 to 7. 24. 04:00. Surface geological survey and slope stability investigation with stereographic projection method in order of slope stability establishment. Partial supplement excavation and SSL. P. C. Anchoring method is able to pre-stressing are think about unstable element after excavation. This slope stability establishment is very successfully completion.

  • PDF

Evaluation on the Effects of Deicing Salts on Crop using Seedling Emergence Assay of Oilseed Rape (Brassica napus) (유채의 출아 검정을 통한 제설제의 작물 영향 평가)

  • Lim, Soo-Hyun;Yu, Hyejin;Lee, Chan-Young;Gong, Yu-Seok;Lee, Byung-Duk;Kim, Do-Soon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.66 no.1
    • /
    • pp.72-79
    • /
    • 2021
  • The increasing use of deicing salts has caused various environmental problems, including crop damage along the motorway where deicing salts are sprayed during winter. Deicing salts used on roads have been reported to negatively affect crops, but little information is known about their impact on crops. A seedling emergence assay was conducted to evaluate the effects of deicing salts on crops using oilseed rape (Brassica napus) as a model plant. We tested five chloride deicing salts consisting of NaCl, CaCl2, or MgCl2 and 1 non-chloride deicing salt (SM-3) at a range of concentrations (25, 50, 100, 200, and 400 mM), and untreated control. Regardless of deicing salts, they significantly delayed and reduced seedling emergence of oilseed rape with increasing salt concentration. Non-linear regression analysis of seedling emergence with a range of salt concentrations by fitting to the log-logistic model revealed that the chloride deicing salts reduced seedling emergence more than the non-chloride deicing salt SM-3. The GR50 value, the concentration causing 50% seedling emergence, of SM-3 was 47.1 mM, while those of the chloride deicing salts ranged from 30.7 mM (PC-10) to 37.5 mM (ES-1), showing approximately 10 mM difference between non-chloride and chloride deicing salts. Our findings suggest that seedling emergence assay is a useful tool to estimate the potential damage caused by deicing salts on crops.

The Rheology of Cement Paste Using Polycarboxylate-Based Superplasticizer for Normal Strength-High Fluidity Concrete (보통강도 고유동 콘크리트용 PC계 고성능 감수제를 사용한 시멘트 페이스트의 레올로지 특성 평가)

  • Kong, Tae-Woong;Lee, Han-Seung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.3
    • /
    • pp.276-286
    • /
    • 2021
  • General high fluidity concrete is the area of high strength concrete with a high amount of cement to secure the required fluidity and workability. Since most of the concrete structures currently used have normal strength, there is a limit to the practical expansion and practicality of use. Thus it is necessary to develop normal strength-high fluidity concrete with low binders that can be used not only in general buildings but also in special buildings, and can greatly reduce construction time and save labor costs. This requires to develop and apply the polycarboxylate-based superplasticizer. In this study, PCE was prepared for each combination of starting materials(WR, HB, RT) and the rheological properties of cement paste were analyzed using ringflow cone and a rotary viscometer. As a result, when PCE with a combination of WR 80%, HB 6.5%, and RT 13.5% was applied, the yield stress can be minimized while securing the plastic viscosity at level of the normal strength. In addition, high fluidity due to the high dispersion effect was confirmed.

Characteristics of concrete intensity using high early strength AE water reducing agent (조강형 AE감수제를 사용한 콘크리트의 강도발현 특성)

  • Kim, Jung-Tai;Kim, Seung-Han;Jang, Seck-Soo;Jung, Yong-Wook;Yeo, In-Dong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.793-796
    • /
    • 2008
  • Recently early strength concrete has been required for economical assurance and the prevention of frost damage in winter through air reduction in construction of concrete structures. This study presented the optimum condition revealing compressive strength 5MPa which has the possibility of removal of form in 24 hours, and researched the changes of unit weight of cement types of high early strength AE water reducing agents, characteristic of compressive strength expression as cure temperature conditions and slump or airspace. Test results showed at $15^{\circ}C$ with compressive strength of 5MPa that premature removal of form was possible in case of using highly early strength PC water reducing agent with unit weight of cement 360 ; 22hours faster than 10, unit weight 360 ; 20hours faster than 7, unit weight 390 ; 18 hours faster than 4 comparing with OP water reducing agent. And at $5^{\circ}C$ in case of using highly early strength PC water reducing agent with unit weight of cement 330 ; 32hours faster than 10, unit weight 360 ; 30hours faster than 7, unit weight390 ; 27hours faster than 4 comparing with OP water reducing agent. Therefore as the temperature rises $10^{\circ}C$, compressive strength of 5MPa reaching hour shortens 10 hours.

  • PDF

Herbal Flora and Succession of Stream Under Management Conditions After its Restoration - Case Study of Yangjaecheon in Seoul - (자연형 하천 복원공사 이후 식생관리에 의한 초본 식물상과 천이 - 서울시 양재천 사례 연구 -)

  • Lee, Yong-Ho;Kang, Byeung-Hoa;Na, Chae-Sun;Yang, Geum-Yeol;Min, Tai-Gi;Hong, Sun-Hee
    • Korean Journal of Weed Science
    • /
    • v.31 no.1
    • /
    • pp.49-70
    • /
    • 2011
  • This study was conducted to examine the change of flora and plant species diversity between 2005 and 2010 in Yangjaecheon (stream) which was divided among three different types of vegetation management method; ecological vegetation management (weeding vines and invasive plants; EVM), plant cultivation (PC) and uncared for vegetation (UC). There were total 478 taxa, composed by 429 spontaneous taxa and 49 cultivated taxa in 2005 and total 424 taxa composed by 318 spontaneous taxa and 106 cultivated taxa in 2010. In spontaneous plants, 201 taxa were distributed over total area, 197 taxa were distributed in only EVM area, 10 taxa in only PC area and 59 taxa in only UC area. Also, the most dominant family (Asteraceae${\rightarrow}$Poaceae) and number of rare taxa (reduced) and wide distributed taxa (increased) was changed from 2005 to 2010. The rate of perennial taxa was found to be increased in only EVM area. In conclusion, EVM is thought to be a more efficient method for plant species diversity of restored stream.

Retraction: A numerical study on the fire smoke behavior by operating the fire prevention system in tunnel-type structure (논문 취소: 터널형 구조물의 방재시설 가동에 따른 화재연기 거동에 관한 수치 해석적 연구)

  • Lee, Ho-Hyung;Choi, Pan-Gyu;Lee, Sang-Don;Heo, Won-Ho;Jo, Jong-Bok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.189-199
    • /
    • 2019
  • In this study, behaviors of fire smoke in the operation of disaster prevention facilities (smoke damper, jet fan) in a tunnel-type structure (soundproof tunnel) were investigated numerically and results of the investigation were compared and analyzed. Through the simulation and analysis, it was found that there was a significant change in the patterns of fire smoke between the opening of the ceiling of a fire vehicle and the closing, and it was shown that the critical temperatures of PC and PMMA, main materials of a soundproof tunnel were not exceeded. In addition, the simulation of installation intervals of smoke dampers showed that the maximum temperature of a soundproof tunnel without smoke dampers was $552^{\circ}C$ while it reached $405^{\circ}C$ when smoke dampers were installed at the installation interval of 50 m. The simulation of the operation of a jet fan showed that the maximum temperature of a soundproof tunnel without a jet fan was $549^{\circ}C$ while it reached only $86^{\circ}C$ when a jet fan was operating. Therefore, it is highly expected that they could create a favorable environment for evacuation and protection of soundproofing materials, and it would be necessary to promote basic studies on tunnels serving various functions and purposes.