• Title/Summary/Keyword: PC콘크리트

Search Result 367, Processing Time 0.024 seconds

Economic Evaluation of the Centrifugal Formed Shell PC Columns (원심성형 중공 PC기둥의 경제성 평가)

  • Park, Jin-Young;Yang, Won-Jik;Ryu, Hong-Sik;Yi, Waon-Ho;Oh, Sang-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.163-164
    • /
    • 2009
  • Recently, RC construction method has needs of many construction expenses and previous by accessory construction progress in construction field. On the other hand, Shell PC column reduces construction expenses and previous. Therefore, the purpose of this study is to the analyze the economical propriety about Centrifugal Formed Shell PC columns application of a field as compared with the RC and PC construction method.

  • PDF

A Model for Reliability-Based Durability Assessment of PC BOX Girder Bridges (신뢰성에 기초한 PC박스거더교의 내구성평가 모형)

  • 조효남;이승재;이정곤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.286-291
    • /
    • 1995
  • The deterioration of PC box girder may cause serious effect on the durability of PC structure compared to that of RC structures. In the durability assessment of PC box girder bridges, a quantitive model on crack width is considered as a measure of durability. This study suggests a durability limit state model for PC box girder bridges. This durability limit state model in formulated based on the conventional models on the cracks in concrete. And the allowable crack width is taken as an assumed value established by the design specification or provided by the maintenance authority of the structure.

  • PDF

Strength of PC walls with Diagonal Reinforcements (대각선 철근이 있는 PC 벽체의 강도)

  • Lim, Woo-Young;Hong, Sung-Gul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.3-4
    • /
    • 2010
  • Strength of PC walls with diagonal reinforcements can be obtained by using the section analysis. Deformation of the diagonal reinforcements is related to that of flexural reinforcement and makes the another tensile strength on the PC wall. Another tensile strength due to diagonal reinforcements is assumed to be 1/3 point of the distance between the flexural reinforcements.

  • PDF

The Effects of the Coplymerization Conditions in Synthesis of Polycarboxylic Type Superplasticizer on Interfacial Properties and on Cement Mortar Fluidity (Polycarboxylate계 콘크리트 유동화제의 합성에 있어서 공중합 조건에 따른 계면물성 변화 및 이의 시멘트 몰탈의 물성에 미치는 영향)

  • Kim, Young-Ho
    • Applied Chemistry for Engineering
    • /
    • v.21 no.4
    • /
    • pp.463-468
    • /
    • 2010
  • The polycarboxylic (PC) type concrete superplasticizer was synthesized. The effects of ethylene oxide group number and its molecular weight on the properties of the polycarboxylic type concrete superplasticizer and the concrete motar properties were studied. To investigated of the interfacial properties of the premixed-concrete with the superplasticizer, the type and the amount of polyethylene glycol, meta acrylate added, and type of the initialization agent were studied. Also the interfacial properties of the superplasticizer aqueous phase, the wettability on the cement particle, the fluidity of the cement mortar, and the strength properties of the concrete were measured. For a high fluidity of the cement mortar and a high strength of concrete, a low value of the surface tension and contact angle were required for PC. To have a good performance for PC, the reaction condition of 1.3 mol ratio of MA against to MPEG was suitable with KSP initiator.

Shear Strength of Prestressed PC-CIP Composite Beams with Vertical Shear Reinforcement (전단 철근 보강된 프리스트레스 PC와 CIP 합성보의 전단강도)

  • Suh, Jung-Il;Park, Hong-Gun;Hong, Geon-Ho;Kang, Su-Min;Kim, Chul-Goo
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.399-409
    • /
    • 2015
  • Recently, the use of composite construction method using precast (PC) and cast-in-place (CIP) concrete is increased in modular construction. For PC members, pre-tensioning is used to improve efficiency of the structural performance. However, current design codes do not clearly define shear strength of prestressed PC-CIP composite members. In this study, 22 specimens were tested to evaluate shear strength of prestressed composite members with vertical shear reinforcement. The test variables were the area ratio of high-strength (60 MPa) to low-strength concrete (24 MPa), prestressing force of strands, shear span-to-depth ratio(a/d), and vertical shear reinforcement ratio. The test results showed the prestressing force did not completely restrain diagonal cracking of non-prestressed concrete in the web. Thus, the effect of prestress force was not insignificant in the effect for monolithic beams. The vertical shear strength and horizontal shear strength of the composite beams were compared with the strength predictions of KCI design method.

A Study on Early Evaluation Method of Durability of PC Concrete According to the Accelerated Curing Conditions (촉진양생조건에 따른 PC콘크리트의 내구성 조기 평가기법 연구)

  • 김관호;박광수;신수균;이준구;장문기
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.169-174
    • /
    • 2002
  • We can consider that the study on early evaluation of compressive strength and durability of concrete is useful to raise safety of quality control of concrete. In this paper, was proposed to method early to predict strength and durability of concrete with parameter, such as Water/cement(W/C) ratio and steam curing conditions. Through analyzing the relationship between the compressive strength and the amount of chloride penetration into concrete specimens, a new formula early estimating durability of the concrete structure was suggested.

  • PDF

Modeling of Precast Concrete Shear Walls BIM Program (BIM 프로그램을 이용한 프리캐스트 콘크리트 전단벽의 모델링)

  • Mun, Ju-Hyun;Yoon, Hyun-Sub;Kim, Jong-Won;Eom, Byung-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.5
    • /
    • pp.451-462
    • /
    • 2022
  • The objective of the study is to establish a BIM modeling of precast concrete(PC) shear wall with various wall-to-base connections. The family library of PC shear wall was established in BIM program using component function in a IFC(Industry foundation classes) file format and SketchUp program. From the BIM program, the amounts of concrete, reinforcing bars and steel materials as well as the interference of arranged reinforcing bars can be accurately evaluated in the PC shear walls with spliced sleeves, bolt, or welding plate connection methods. Although the additional metallic materials such as steel plates, bolts, and nuts were used in the PC shear walls with welding plate connection method, their amounts of materials, economic efficiency, and environmental impact were similar to those with spliced sleeve connection. Consequently, the bolt or welding connection is a highly applicable method as wall-to-base connection of PC shear walls, and it was a more useful method than spliced sleeve method, particularly considering the constructability.

An Experimental Study on Thermal Damage under Tunnel Fire Scenario to Concrete PC Pannel Lining (터널 화재시나리오에 따른 콘크리트 PC패널라이닝의 열적손상에 관한 실험적 연구)

  • Kim, Heung-Youl;Park, Kyung-Hun;Kim, Hyung-Jun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.477-480
    • /
    • 2008
  • In tunnel, though the frequency of fire occurrence is relatively lower than other structures, the characteristics of sealed space tends to cause the temperature to rapidly rise to more than $1000^{\circ}C$ within 5 minutes after fire, which might eventually lead to a large fire that usually results in a loss of lives and the damage to the properties, not to mention a huge cost necessary for repair and maintenance after fire. Referring to foreign tunnel fire scenarios, it clarified the heat transfer characteristics of concrete PC panel lining depending on fire intensity (ISO, MHC, RWS), and to identify the range of thermal damage, the evaluation was carried out using ITA standard. As a result, 39mm under ISO fire condition, 50mm under MHC and 100mm under RWS were measured. And when it comes to spalling, 30mm was measured under RWS. When PC panel was designed to serve the support, a fire resistance to the minimum depth of 100mm of the concrete that might be damaged under the fire shall be maintained, and in case of a non-support structure, PC lining shall have at least 100mm thickness.

  • PDF