• Title/Summary/Keyword: PATCH

Search Result 3,524, Processing Time 0.025 seconds

Impact of composite patch on the J-integral in adhesive layer for repaired aluminum plate

  • Kaci, D. Ait;Madani, K.;Mokhtari, M.;Feaugas, X.;Touzain, S.
    • Advances in aircraft and spacecraft science
    • /
    • v.4 no.6
    • /
    • pp.679-699
    • /
    • 2017
  • The aim of this study is to perform a finite element analysis of the Von Mises stresses distribution in the adhesive layer and of the J-Integral for a damaged plate repaired by a composite patch. Firstly, we study the effect of the fiber orientation, especially the position of the layers that have orientation angle different of $0^{\circ}$ from the first layer which is in all cases of our study oriented at ($0^{\circ}$) on the J-Integral. Secondly, we evaluate the effects of the mechanical properties of the patch and the use of a hybrid patch on the reduction of stresses distribution and J-Integral. The results show clearly that the stacking sequence for the composite patch must be selected to absorb optimally the stresses from the damaged area and to position the various layers of the composite under the first layer whose fibers orientation will remain in all cases equal to $0^{\circ}$. The use of a hybrid composite reduces significantly the J-Integral and the stresses in both damaged plate and the adhesive layer.

Design and Implementation of Patch Management System for Improving System Security (시스템 보안성 향상을 위한 패치관리시스템 설계 및 구현)

  • 서정택;윤주범;최대식;박응기;박춘식
    • Convergence Security Journal
    • /
    • v.4 no.2
    • /
    • pp.43-51
    • /
    • 2004
  • Operating systems and application programs have security vulnerabilities derived from the software development process. Recently, incident cases related with the abuses of these vulnerabilities are increasing and the damages caused by them are becoming very important security issues all over the nations. Patch management is one of the most important processes to fix vulnerabilities of softwares and to ensure a security of systems. Since an institute or a company has distributed hierarchical and heterogeneous systems, it is not easy to update patches promptly. In this paper, we propose patch management framework to safely distribute and install the patches on Windows, Linux, and Solaris client systems. Besides, we considered extensibility and hierarchical structure for our patch management framework to support large scaled network environment.

  • PDF

A Review of Total Correction in 48 Cases of Tetralogy of Fallot (Fallot 사징증(四徵症) 외과적(外科的) 완전교정(完全矯正)에 대한 임상적(臨床的) 고찰(考察))

  • Suh, Kyung Phill
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.198-206
    • /
    • 1976
  • A Total of Forty eight patients underwent open-heart surgery for correction of tetralogy of Fallot at the Seoul National University Hospital from January 1974 to October 1976, with an overall survival rate of 77 per cent. Operative mortality varied according to severity of the lesion, age of the patient, nature of previous surgical treatment and presence or absence of an outflow tract patch across the pulmonary valve ring. Eleven patients died in the early postoperative period and thirty seven patients were discharged from the hospital alive. A patch of the right ventricular outflow tract and pulmonary annulus was required to relieve pulmonic stenosis in 24 patients. There were 10 deaths in this group (42%) as compared to 1 death in the group of 24 patients who were corrected without a patch. Operative mortality was especially higher when an inlay patch was placed across the pulmonary valve ring. This may be related to the possibly greater anatomic severity of these cases and to the longer operating time when a patch was used. The electrocardiogram showed right ventricular hypertrophy in 35 cyanotic patients. Intraventricular conduction was normal in 34 patients before operation. It was normal postoperatively in only 5 of 34 patients in this group who survived surgery. Complete right bundle branch block appeared at operation in 21 patients, and 8 patients developed incomplete right bundle branch block. Major causes of death were progressive cardiac failure (4), Complete atrioventricular dissociation (3), bleeding (2), cardiac tamponade (1), and sudden cardiac arrest (1)

  • PDF

Performance Improvement of Soccer Robot by Vision Calibration and Patch Change in Real Time Environment (실시간 환경에서의 영상조정 및 패치 변경에 의한 축구로봇의 성능개선)

  • Choi, Jeong-Won;Kim, Duk-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.156-161
    • /
    • 2009
  • This paper proposes a new method about performance improvement of soccer robots system by the revision of lens distortion most commonly occurred in camera and the revision of position and angle error in robot patch for the realization of robot position. Among the lens distortions, we revise geometrical distortion and apply it to soccer robots system for realtime environment. Patch used in the recognition and the distinction for coordination and direction of robot occurs a position and angle error according to the figure of it. In this paper, we suggest the method of reduction for position and angle error of robot by improved patch and verify its propriety through the experiment.

Residual Deformation Induced by the Repair of Composite Shell Structures (복합재료 쉘 구조물의 수리 시 발생하는 잔류변형)

  • 최항석;정의승;이수용
    • Composites Research
    • /
    • v.12 no.4
    • /
    • pp.17-24
    • /
    • 1999
  • Finite element analysis and experiment are performed to investigate residual deformation induced by the repair of composite shell structures using a prepreg patch method. The finite element program is developed on the basis of a three-dimensional degenerated shell element and the first order shear deformation theory. The results analyzed for the laminated shell with free boundary conditions are compared with strains measured during the prepreg patch repair. Final residual stresses occur greatly near the patch when the laminated shell with all edges clamped is repaired using the prepreg patch. Stacking sequences of the laminated shell and patch affect significantly the residual stresses which occur even if they are the same.

  • PDF

Surgical Treatment of Endocardial Cushion Defects (A Report of 5 Cases) (심내막상 결손증 치험 5례)

  • 류지윤
    • Journal of Chest Surgery
    • /
    • v.21 no.3
    • /
    • pp.574-582
    • /
    • 1988
  • Endocardial cushion defects is a rare congenital heart disease. We experienced two complete endocardial cushion defects[ECD] and three partial ones, which were successfully repaired between 1986 and 1987. In a patient of complete ECD, associated with secundum ASD, Pulmonary stenosis and Down`s syndrome, the atrial and ventricular septal defects were closed separately with bovine pericardium and Dacron patches respectively, and then pulmonary stenosis was relieved by transannular patch widening in addition to valvotomy and infundibulectomy. In another patient with complete ECD, small interventricular communication was closed with simple suture with pledget and primum ASD was closed with pericardial patch. In first patient of partial ECD, primum atrial septal defect was closed with pericardial patch. In second patient of partial ECD, associated with secundum ASD, direct closure of secundum ASD and patch closure of primum ASD were performed. In third patient of partial ECD, associated with patent foramen ovale[PFO], primum ASD was closed with bovine pericardial patch and PFO was closed directly. In all patient except third patient of partial ECD, mitral clefts were closed with three or four 5-0 prolene interrupted sutures. Transient A-V dissociation developed postoperatively in two patients and transient nodal rhythm developed postoperatively in other two patients. Heart failure in complete ECD with Down`s syndrome was overcome with medical treatment.

  • PDF

Skin Permeation Characteristics of Estradiol Patches and Their Comparative Efficacy Test in Ovariectomized Rabbits (에스트라디올 패취의 피부투과 특성 및 난소제거 토끼에서의 비교 효력시험)

  • Ryoo, Je-Phil;Choi, Mi-Suk;Choi, Jong-Kun;Kim, Soo-Hyeon;Kim, Eung-Goo;Yoon, Byung-Il
    • Journal of Pharmaceutical Investigation
    • /
    • v.25 no.1
    • /
    • pp.47-54
    • /
    • 1995
  • Transdermal patch formulations of estradiol to treat post-menopausal symptoms and prevent osteoporosis in women were developed and evaluated for the permeation characteristics through the excised hairless mouse abdorminal skin and the uterotropic effect on the ovariectomized rabbits. The design of patch formulations was optimized by varying several formulation parameters, such as type of enhancers, amount of enhancers, amount of drug loading and coating thickness. Compared to a commercially available transdermal product, several patch formulations showed the similar skin permeation profiles (following zero-order kinetics), but their skin permeation rates were lasted for the longer period (a week). In one-week uterotropic efficacy test in the ovariectimized rabbits, the selected patch formulations showed the positive effect in atrophy of the urogenital epithelium. The mean values of uterus weight in rabbits after application of patches containing estradiol were much higher than those in control group (containing no drug).

  • PDF

GPS/GLONASS Microstrip Active Antenna Apply to Curve Surface (곡면에 부착 가능한 GPS/GLONASS 마이크로스트립 능동 안테나)

  • Kim, Mi-Suk;Son, Seok-Bo;Joo, Hahn-Kie;Bae, Joon-Sung;Kim, Joon-O
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • In this paper, dual-feed circularly polarized microstrip patch antenna for GPS L1, GPS L2, GLONASS L1 signal was fabricated by using stacked patch. It was fed by dual coaxial probe on the patch at 50ohm impedance, and was simulated to resonate at GPS L1, GPS L2, GLONASS L1. To realize characteristics of right hand circular polarization using dual-feed stacked patch antenna and hybrid coupler for $90^{\circ}$ phase difference. Output of hybrid coupler was contacted input of Low Noise Amplifier(LNA). The LNA using dual band pass filter was designed and fabricated. The measured results of the implemented antenna is VSWR < 1.5 : 1 and the gain of 32dB(Zenith) over at GPS L1, L2, GLONASS L1.

The Design and Experiment of a Planar Patch Sensor for Partial Discharge Diagnostics in 6.6 kV Rotating Machine Stator Windings

  • Yang, Sang-Hyun;Park, Noh-Joon;Park, Dae-Hee;Kim, Hee-Dong;Lim, Kwang-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.173-176
    • /
    • 2009
  • In the stator windings of a 6.6 kV rotating machine, internal discharges, slot discharges, and surface discharges are mainly caused by internal voids and insulation degradation. If a partial discharge(PD) occurs in an inner-part of the stator windings, it will cause electromagnetic pulses with wide frequency ranges. Discharge sparks and electromagnetic pulses generated from a discharge source, can be detected using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, a planar patch sensor was designed and fabricated using a CST-MWS simulation, and PD signals from an artificially defected stator winding were also measured by the sensor proposed in this study. Furthermore, an HFCT was used as a reference sensor and compared with the proposed new planar patch sensor. In the results of the experiment, the planar patch sensor showed a similar performance to the HFCT sensor.

Effects of Lidocaine Patch Application to Decrease Pain and Fear during Blood Sugar Test in Elderly Patients with DM (리도카인 패치 적용이 당뇨노인환자의 혈당검사 시 통증과 두려움에 미치는 효과)

  • Kim, Se Young;Kim, Jin;No, In Sun
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.23 no.1
    • /
    • pp.12-20
    • /
    • 2016
  • Purpose: This study was done to examine the effects of lidocaine patch application to decrease pain and fear during blood sugar testing in elderly patients with DM. Methods: The participants were 56 elderly patients admitted to J geriatric hospital in G city, Korea. Of the elderly patient, 27 were assigned to the experimental group and 29 to the control group. Participants in the experimental group applied a lidocaine patch on the fingertip for 30 minutes before a blood sugar test. The control group applied a plaster on the fingertip. Pain was evaluated using a visual analogue scale and fear using the Procedure Behaviour Check List. The results were compared using paired t-test and t-test. Results: The scores for pain and fear were significantly lower in the experimental group compared to the control group. Conclusion: The lidocaine patch was found to be an effective local anesthetic to relieve pain and fear during blood sugar test in elderly patients with DM without any severe adverse events.