• 제목/요약/키워드: PARTICLE SIZE

검색결과 7,284건 처리시간 0.033초

Experimental Analysis on Particle Growth in TEOS/O2 Plasma Reactor (TEOS/O2용 플라즈마 반응기에서의 미립자 성장에 대한 실험적 분석)

  • Hong, Sung-Taik;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • 제23권A호
    • /
    • pp.175-179
    • /
    • 2003
  • A study on the particle growth in $TEOS/O_2$ plasma was performed by observing the particle size and its morphology by TEM. The qualitative chemical analysis of particles was also determined by the EDS (Energy Dispersive X-Ray Spectrometer). The effects of process variables such as the plasma on-time and bubbler temperature on the particle growth were investigated. The particle size becomes larger as the plasma on-time because of the longer coagulation, and also as the bubbler temperature increases because of the faster coagulation between particles.

  • PDF

Evaluation of Alginate Microspheres Prepared by Emulsion and Spray Method for Oral Vaccine Delivery System (유화법과 분무법에 의해 제조된 경구백신용 알긴산 마이크로스피어의 평가)

  • Jiang, Ge;Jee, Ung-Kil;Maeng, Pil-Jae;Hwang, Sung-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • 제31권4호
    • /
    • pp.241-256
    • /
    • 2001
  • Alginate microspheres, containing fluorescein isothiocyanate-bovine serum albumin (FITC-BSA) or green fluorescent protein (GFP) were prepared and used as a model drug to develop the oral vaccine delivery system. The alginate microspheres were coated with poly-L-lysine or chitosan. Two methods, w/o-emulsion and spray, were used to prepare alginate microspheres. To optimize preparation conditions, effects of several factors on the particle size and particle morphology of microsphere, and loading efficiency of model antigen were investigated. In both preparation methods, the particle size and the loading efficiency were enhanced when the concentration of sodium alginate increased. In the w/o-emulsion preparation method, as the concentration of Span 80 was increased from 0.5% to 2%, the particle size was decreased, but the loading efficiency was increased. The higher the emulsification speed was, the smaller the particle size and loading efficiency were. The concentration of calcium chloride did not show any effect on the particle size and loading efficiency. In the spray preparation method, the particle size was increased as the nozzle pressure $(from\;1\;kgf/m^2\;to\;3\;kgf/m^2)$ and spray rate was raised. Increasing calcium chloride concentration (<7%) decreased the particle size, in contrast to no effect of calcium chloride concentration on the w/o-emulsion preparation method. Alginate microspheres prepared by two methods were different in the particle size and loading efficiency, the particle size of microspheres prepared by the spray method was about $2-6\;{\mu}m$, larger than that prepared by the w/o emulsion method $(about\;2{\mu}m)$, and the loading efficiency was also higher with spray method. Furthermore, drying process for the microspheres prepared by the spray was simpler and easier, compared with the w/o emulsion preparation. Therefore, the spray method was chosen to prepare alginate microspheres for further experiments. Release pattern of FITC-BSA in alginate microspheres was evaluated in simulated intestinal fluid and PBS (phosphate buffered saline). Dissolution rate of FITC-BSA from alginate/chitosan microsphere was lower than that from alginate microsphere and alginate/poly-L-lysine microsphere. By confocal laser scanning microscope, it was revealed that alginate/FITC-poly-L-lysine microspheres were present in close apposition epithelium of the Peyer's patches of rabbits following inoculation into lumen of intestine, which proved that microspheres could be taken up by Peyer's patch. In conclusion, it is suggested that alginate microsphere prepared by spray method, showing a particle size of & $10\;{\mu}m$ and a high loading efficiency, can be used as a model drug for the development of oral vaccine delivery system.

  • PDF

Effect of Dry Deposition on Water Quality -The comparison of several methodologies for estimating dry deposition flux (수질에 대한 대기건식침적의 영향 - 건식침적량 추정 방법론의 비교를 중심으로)

  • Cheong, Jang-Pyo
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제22권1호
    • /
    • pp.159-168
    • /
    • 2008
  • A special field experiment has been carried out from March 2001 to June 2001 at the Changhowon in Kyunggi to investigate a better methodology for the estimation of dry deposition of pollutions applicable in Korea. In this study, dry deposition plate was used to measure of total and water soluble acidic mass fluxes, and CPRI(Coarse Particle Rotary Impactor), CI(Cascade Impactor) were also used to measure ambient concentrations in various particle size ranges. Sehmel-Hodgson model was used to estimate dry depostion velocity and Weibull probability distribution function was applied to get generalized particle size distribution for the size fractioned concentration data sampled by CPRI and CI. Atmospheric dry deposition fluxes of mass and ionic matters estimated by the various techniques(one-step, multi-step, equi-concentration, subdivision for only the coarse particle range, applying Weibull distribution function, etc.) were compared to flux data sampled by DDP. It was found out that the deposition fluxes estimation methodology calculated by the each particle size range devided by particle size distribution characteristics and the rapidly changed points of deposition velocity using Weibull probability distribution function was the most applicable.

Particle-size-dependent aging time scale of atmospheric black carbon (입자 크기의 함수로 나타낸 대기 중 블랙카본의 변성시간척도)

  • Park, Sung Hoon
    • Particle and aerosol research
    • /
    • 제5권2호
    • /
    • pp.45-52
    • /
    • 2009
  • Black carbon, which is a by-product of combustion of fossil fuel and biomass burning, is the component that imposes the largest uncertainty on quantifying aerosol climate effect. The direct, indirect and semi-direct climate effects of black carbon depend on its state of the mixing with other water-soluble aerosol components. The process that transforms hydrophobic externally mixed black carbon particles into hygroscopic internally mixed ones is called "aging". In most climate models, simple parameterizations for the aging time scale are used instead of solving detailed dynamics equations on the aging process due to the computation cost. In this study, a new parameterization for the black carbon aging time scale due to condensation and coagulation is presented as a function of the concentration of hygroscopic atmospheric components and the black carbon particle size. It is shown that the black carbon aging time scale due to condensation of sulfuric acid vapors varies to a large extent depending on the sulfuric acid concentration and the black carbon particle size. This result indicates that the constant aging time scale values suggested in the literature cannot be directly applied to a global scale modeling. The aging time scale due to coagulation with internally mixed aerosol particles shows an even stronger dependency on particle size, which implies that the use of a particle-size-independent aging time scale may lead to a large error when the aging is dominated by coagulation.

  • PDF

EFFECT OF TIME AFTER FEEDING ON DISTRIBUTION OF FEED PARTICLES IN THE GASTROINTESTINAL TRACT OF SHEEP GIVEN ORCHADGRASS HAY ONCE A DAY

  • Sekine, J.;Imaki, Y.;Kuninishi, Y.;Oura, R.;Miyazaki, H.;Okamoto, M.;Asahida, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제5권1호
    • /
    • pp.55-61
    • /
    • 1992
  • To determine the effect of time after feeding on distribution of particle size of digesta in the gastrointestinal tract, 16 sheep given orchardgrass first cut hay were slaughtered at 2, 8, 16 and 24 hours after feeding and digesta in diverse sites of the tract were sieved into four fractions of particle size larger than $1180{\mu}m$, 300-1180, 45-300 and less than 45. Following results were obtained: 1) In the reticulo-rumen, the proportion of particles larger than $1180{\mu}m$ decreased with the time after feeding, while the other particle size fractions did not change with time after feeding. 2) In the post-ruminal alimentary tract, the proportion of particles larger than $1180{\mu}m$ was significantly smaller than that in the reticulo-rumen and distribution of fractions of every particle size stayed consistently at about the same level irrespective of the time after feeding. 3) In the cecum, the fraction of particle size less than $45{\mu}m$ appeared to be selectively retained when the passage rate was considered.

Experimental Studies on Plasmon Resonance of Ag Nanoparticles on Highly Ordered Pyrolytic Graphite (HOPG)

  • Lopez Salido, Ignacio;Bertram, Nils;Lim, Dong-Chan;Gantefor, Gerd;Kim, Young-Dok
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권4호
    • /
    • pp.556-562
    • /
    • 2006
  • Studies on Ag nanoparticles grown on Highly Ordered Pyrolytic Graphite (HOPG) using HREELS provide different results for smaller and larger particle sizes corresponding to Ag coverages below and above 4 monolayers, respectively. For the larger particles, a positive frequency shift with decreasing particle size and a broadening of the plasmon resonance were observed with decreasing particle size, in line with previous studies on Ag on alumina. For the smaller particles, in contrast, a shift to lower energy with decreasing particle size, and a narrowing of the plasmon resonance with decreasing particle size can be found. The asymmetry of the Ag-features present for Ag coverages above 4 monolayers disappears for Ag coverages below 4 monolayers. The result for the smaller particles can be rationalized in terms of change of the particle growth mode with increasing particle size, which corroborates our STM data, as well as electronic effects due to the metal/support charge transfer.

Characterization of submicron Particles Using a Single Particle Mass Spectrometer(I) - Non - Linear Correlation Between Particle Size and Mass Spectra Signals - (단일입자 질량분석기를 애용한 서브마이크론 입자의 특성화(I) - 입자의 크기와 질량분광신호의 비선형성 -)

  • Zachariah Michael R.;Lee Donggeun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제29권4호
    • /
    • pp.453-459
    • /
    • 2005
  • In this paper, we are proposing a robust tool which is capable of measuring the size and elemental composition of submicron particles from twenty to several hundreds nanometers at the same time, i.e., named Single Particle Mass Spectrometer (SPMS). The home-made SPMS employs a laser ablation/multi-photon ionization method to tear a nanoparticle into the constituent elemental ions. One thing different from the conventional Aerosol Time-of-Flight Mass Spectrometer (ATOFMS) is the power of the ionization laser. Much strong laser used in this work makes it possible to generate elemental ions rather than molecular ions from a nanoparticle. Also the use of high power laser may guarantee a complete ionization of a particle, which was confirmed by the existence of multiple charged ions. If a particle is evaporated/ionized completely and detected through electric field-free TOF tube without any loss, we can extract the original particle volume from the measured total ion numbers. Collecting a number of particles mass spectra, we get a database of size and elemental composition of nanoparticles, with which we may take a took into any kinds of chemical reaction occurring at nanoscale. Several issues related to size estimation by SPMS will be discussed.

Coal particle distribution inside fuel droplets of high loading CWM (고부하도 CWM 연료방울안에 존재하는 미분탄 분포)

  • 김성준;유영길
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제15권2호
    • /
    • pp.618-629
    • /
    • 1991
  • The purpose of this experiment is to understand the distribution of coal particles inside CWM droplet which is believed to be a very important factor controlling the flame stability. CWM slurry is atomized by an air assisted twin fluid nozzle. An experimental rig is designed and fabricated. The mean size of coal particle distribution in CWM slurry, atomizing air pressure, coal particle loading in slurry and sampling position inside spray are main experimental variables. The atomized CWM droplets are sampled on the thin white layer of magnesium oxide by the emergency sampling shutter. The sampled coal particles on magnesium oxide layers are collected into test tubes and dispersed completely by Ultra-Sonicator. The size distribution of coal particles inside droplets are measured by Coulter Counter. The presence of coal particle inside the impressions of droplets on magnesium oxide layer are investigated by photo technique. There are quite many droplets which do not have any coal particles. Those are just water droplets, not CWM droplets. The population ratio of droplets without coal particles to toal number of droplets is strongly affected by the mean size of coal particle distribution in slurry and this ration becomes bigger number as the mean size of coal particles be larger. The size distribution of coal particles inside CWM droplets is not even and depends on the size of droplet. Experimental results show that the larger CWM droplets has droplets has bigger mean value of particle size distribution. This trend becomes more evident as the atomizing air pressure is raised and the mean size of coal particles in CWM slurry is bigger. That is, the distribution of coal particles inside CWM dropolets is very much affected by the atomizing air pressure and the mean size of pulverized coal particles in CWM slurry.

Effect of Variation in Particle Size of WC and Co Powder on the Properties of WC-Co Alloys (WC와 Co원료 입자크기 변화에 따른 WC-Co계 초경합금의 특성 변화)

  • Chung, Tai-Joo;Ahn, Sun-Yong;Paek, Yeong-Kyeun
    • Journal of the Korean Ceramic Society
    • /
    • 제42권3호
    • /
    • pp.171-177
    • /
    • 2005
  • The effect of variation in particle size of WC and Co powder on the properties of WC-Co alloys was investigated. WC and Co powders having different particle sizes were used in the fabrication of $WC-10\;wt\%$Co composites. High hardness and low fracture toughness alloy was obtained with the decrease in WC particle size regardless of Co particle size. It was newly found in this investigation that the initial particle size of Co as well as WC had a great role in the microstructure and properties of WC-Co hard materials. The average grain size and fracture toughness of WC-Co alloys using same WC powder size increased and their hardness decreased with the use of relatively finer Co binder.

Manufacture of Ultra Fine CuO Powder from Waste Copper Chloride Solution by Spray Pyrolysis Process

  • Yu, Jae-Keun;Ahn, Zou-Sam;Sohn, Jin-Gun
    • Proceedings of the IEEK Conference
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.165-170
    • /
    • 2001
  • The main purpose of this study is to generate a fine copper oxide powder of high purity, with a compact structure and a uniform particle size by a spray pyrolysis process. The raw material is a waste copper chloride solution formed in the manufacturing process of Print Circuit Board (PCB). This study also examines the influences of various factors on the properties of the generated powder. These factors include the reaction temperature, the inflow speed of the raw material solution, the inflow speed of the air, the size of the nozzle tip, and the concentration of the raw material solution. It is discovered that, as the reaction temperature increases from 80$0^{\circ}C$ to 100$0^{\circ}C$ , the particle size of the generated powder increases accordingly, and that the structure of the powder becomes much more compact. When the reaction temperature is 100$0^{\circ}C$, the particle size of the generated powder increases as the concentration of copper in the raw material solution increases to 40g/l, decreases as the concentration increases up to 120g/l, and increases again as the concentration reaches 200g/1. In the case of a lower concentration of the raw material solution, the generated powder appears largely in the form of CuO. As the concentration increases, however, the powder appears largely in the form of CuCl. When the concentration of copper in the raw material solution is 120g/1, the particle size of the generated powder increases as the inflow speed of the raw material solution increases. When the concentration of copper in the raw material solution is 120g/1, there is no evident change in the particle size of the generated powder as the size of the nozzle tip and the air pressure increases. When the concentration is 40g/1, however, the particle size keeps increasing until the air pressure increases to 0.5kg/$\textrm{cm}^2$, but decreases remarkably as the air pressure exceeds 0.5kg/$\textrm{cm}^2$.

  • PDF