• 제목/요약/키워드: PAD Response

검색결과 128건 처리시간 0.033초

Immunomodulatory effect of Tinospora cordifolia and Centella asiatica and its modulation on cyclophosphamide challenge

  • Siddiqui, NA;Ali, Mohd;Singh, Shobhna
    • Advances in Traditional Medicine
    • /
    • 제8권4호
    • /
    • pp.380-385
    • /
    • 2008
  • Ethanolic extracts of T. cordifolia and C. asiatica were evaluated for immunostimulatory effect in mice against sheep RBCs as antigen by three models viz. delayed type hypersensitivity reaction, ercent change in neutrophil count and haemagglutination titre. Immunostimulatory effect in the presence of immunosuppressant agent, cyclophosphamide (100 mg/kg, i.p.) was also investigated. T. cordifolia and C. asiatica significantly (p < 0.001, p < 0.05 respectively) enhanced foot pad thickness when measured after 24 hours of sheep RBC antigen challenge. Both the plant materials increased foot pad thickness even after being subjected to immunosuppressant exposure. T. cordifolia revealed enhanced neutrophil counts, while C. asiatica had no significant effect on neutrophil counts. T. cordifolia exhibited significantly (P < 0.01) elevated neutrophil levels even in the presence of cyclophosphamide administration. Both the plants exhibited humoral antibody response, as haemagglutination titre values were significantly high as compared to control. T. cordifolia and C. asiatica could combat immunosuppressant effect of cyclophosphamide (P < 0.01). This suggests that T. cordifolia and C. asiatica can be regarded as biological response modifiers and can be utilized for the development of immunostimulating agent among plant sources.

제진대(Isolation Pad)의 진동허용규제치에 기준한 동특성(動特性) 규명에 관한 연구 (A Study on the Verification of Dynamic Properities on the basis of Vibration Criteria of Isolation Pad)

  • 백재호;이홍기;서항석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.869-874
    • /
    • 2001
  • In order that precision equipment using high precision industrial operate normally. vibration criteria of expected area that equipment be set up is micrometer level. that method is a trust design for apply to in field, when there attend to quantifiable method. Hence, semi -empirical method that using on the basis of experimental data about undefined information (properities of vibration source, dynamic properities of structure, etc.,) for prediction of vibration response make the use of dynamic structure design of semiconductor & TFT-LCD in the inside and outside country. Like this, for doing an optimal design of dynamic about structure, it is best important to get trust data that apply to semi-empirical method that is method of prediction vibration level. In this paper, on the basis of experimental data which was offered by a manufacturing company Of precisin equipment that plan to set up in semiconductor factory, we predicted vibration response on expected area that equipment be set up.

  • PDF

Synchronous Vibration Control of a Rigid Rotor System using Active Air Bearing

  • Kwon, Tae-Kyu;Qiu, Jin-Hao;Tani, Jun-Ji;Lee, Seong-Cheol
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제3권2호
    • /
    • pp.87-94
    • /
    • 2002
  • This paper presents the synchronous vibration control of a rotor system using an Active Air Bearing(AAB). In order to suppress the synchronous vibration, it is necessary to actively control the air film pressure or the air film thickness. In this study, active pads are used to control the air film thickness. Active pads are supported by the pivots containing piezoelectric actuators and their radial positions can be actively controlled by applying voltage to the actuators. Disturbances and various kinds of external forces can cause the shaft vibration as well as the change of the air film thickness. The dynamic behaviors of a rotary system supported by two tilting-pad gas bearings and its active stabilization using the tilting-pads as actuators are investigated numerically. The PID controller is applied to the tilting-pad gas bearing system with three pads, two of which contain piezoelectric actuators. To test the validity of the theoretical method, the performance of this control method is evaluated through experiments. The experimental results show the effectiveness of the control system for suppressing the unbalanced response of the rigid modes.

능동 공기 베어링에 의한 로터계 동기진동의 PID제어 (PID Control of a Synchronous Rotor System Vibration with Active Air Bearing)

  • 권대규;이영춘;이성철
    • 한국정밀공학회지
    • /
    • 제18권8호
    • /
    • pp.32-39
    • /
    • 2001
  • This paper presents the synchronous vibration control of a rotor system using an Active Air Bearing(AAB). In order to suppress the synchronous vibration, it is necessary to actively control the air film pressure or the air film thickness. In this study, active pads are used to control the air film thickness. Active pads are supported by the pivots containing piezoelectric actuators and their radial positions can be actively controlled by applying voltage to the actuators. Disturbances and various kinds of external force can cause the shaft vibration as well as the change of the air film thickness. The dynamic behaviors of a rotary system supported by two tilting-pad gas bearings and its active stabilization using the tilting-pads as actuators are investigated numerically. The PID controller is applied to the tilting-pad gas bearing system with three pads, two of which contain piezoelectric actuators. To test the vapidity of the theoretical method, the performance of this control method is evaluated through experiments. The experimental results show the effectiveness of the control system for suppressing the unbalanced response of the rigid modes.

  • PDF

벨로우즈를 이용한 인라인스케이트의 브레이크 시스템 개발 (A Development of Brake System for Inline Skate using Bellows)

  • 이은준;박명관;주동우
    • 한국정밀공학회지
    • /
    • 제16권3호통권96호
    • /
    • pp.30-37
    • /
    • 1999
  • This paper represents the development of the brake system for the inline skate using bellows. The inline skate that is used at present has defects due to frequent impulse, which weakens the breaking force by damaging the parts. Therefore to solve these problems a break system for the inline skates using hydraulics is suggested. To solve the oil leakage problems, bellows is used. Also to prevent the breaks from not touching the ground when skating the bellows is placed at the heel, high as possible. To obtain fast response speed, the ratio of inner diameter of the bellows is changed so that with only a small displacement from the bellows the rubber pad attached to the bellows will touch the ground fast. The performance of the break system using bellows depends on the optimal design of the bellows. Therefore the parameters that changes the form of the bellows are tested and also the interaction between the forces are investigated. The performance of new model brake system with bellows and old model system with only a rubber pad without bellows was estimated through observation of braking posture.

  • PDF

유연다물체동적해석을 이용한 무도상교량 침목패드의 최적 강성 산정 (Optimum Stiffness of the Sleeper Pad on an Open-Deck Steel Railway Bridge using Flexible Multibody Dynamic Analysis)

  • 채수호;김민수;백인철;최상현
    • 한국전산구조공학회논문집
    • /
    • 제35권2호
    • /
    • pp.131-140
    • /
    • 2022
  • 레일장대화는 무도상교량의 소음, 진동, 충격 등의 문제점을 해결할 수 있는 경제적인 방안 중 하나이며, 최근 연동식 침목고정장치를 이용한 SSF 공법이 개발된 바 있다. 이 연구에서는 연동식 침목고정장치 적용 시 레일 높이 조정 및 열차 통과 시의 충격 흡수를 목적으로 교량침목 하부에 삽입되는 침목패드의 최적 연직강성을 결정하는 과정을 제시하였다. 침목패드의 최적 연직강성 결정을 위하여 관련 기존 기준을 검토하였으며, 유연다물체동적해석을 통하여 침목패드의 연직강성 변화에 따른 주행안전성, 승차감 및 궤도의 안전성에 대한 지표들과 교량 응답 변화를 검토하였다. 유연다물체동적해석은 상용프로그램인 ABAQUS와 VI-Rail을 이용하여 수행하였다. 수치해석은 30m 상로판형교에 대한 교량모델을 이용하여 수행하였으며, 침목패드의 연직강성이 7.5kN/mm ~ 240kN/mm로 변화할 때 ITX 새마을, KTX 및 화차 통과 시의 응답을 산정하였다. 수치해석에 적용된 궤도구성품 조건에서 침목패드의 최적 강성은 100kN/mm로 산정되었다.

차동 연결된 Varactor를 이용한 6Gbps CMOS 피드포워드 이퀄라이저 (A 6Gbps CMOS Feed-Forward Equalizer Using A Differentially-Connected Varactor)

  • 문용삼
    • 대한전자공학회논문지SD
    • /
    • 제46권2호
    • /
    • pp.64-70
    • /
    • 2009
  • 0.13-um CMOS 공정을 이용하여 3GHz에서 6.2dB의 gain을 갖는 피드포워드 이퀄라이저를 구현하고 14.7dB의 감쇄를 갖는 7-m SATA 케이블을 통해 6Gbps의 데이터를 에러 없이 복원하였다. 제안한 이퀄라이저 회로는 varactor의 차동 연결을 통해서 기존 이퀄라이저에서 사용되는 varactor 면적의 1/4만을 사용하도록 설계되어 pad-frame에 집적할 수 있을 뿐만 아니라, 높은 동작 주파수 및 3.6mW의 낮은 전력 소모를 유지할 수 있다.

저널 공기 베어링에 의해 지지되어진 강체 로터 계의 동특성 해석 (Dynamic Characteristics Analysis of a Rigid Rotor System Supported by Journal Air Bearings)

  • 권대규;곡순이;이성철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1026-1031
    • /
    • 2001
  • In this paper. the dynamic characteristics of a super high-speed tilting-pad air bearing(TPGB) used in a turbo expander with high expansion ratio are analyzed. The dynamic behavior and stability of a rotary system supported by two journal air bearings are investigated numerically. The transient response of the shaft is obtained by simultaneously solving the equation of motion of the shaft and the dynamic Reynolds equation. The stiffness and damping coefficients of the bearing are calculated from the loading coefficients of the bearing are calculated from the loading capacity. shaft velocity and displacement by using a curve fitting method. The natural frequencies of the 1st and 2nd rigid modes can be calculated from these coefficients. The theoretical method of a rigid rotor system is verified by experimentsut.

  • PDF

600HP급 기어구동형 터보 공기압축기 회전체계의 동역학적 설계 및 해석 (Rotordynamic Design and Analysis of the Rotor-Bearing System of a 600HP Gear Driven Turbo-Compressor)

  • 최상규;김영철;권병수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 추계학술대회논문집; 한국과학기술회관; 6 Nov. 1997
    • /
    • pp.50-57
    • /
    • 1997
  • A 600HP class high-speed gear driven 3-stage turbo-compressor (IGCC : Integrally Geared Centrifugal Compressor) driven by a 3600 rpm AC induction motor has been designed, of which low speed pinion runs at 35000 rpm and high speed pinion at 50000 rpm nominally. Due to its high speed operation, the system requires very reliable bearing selection and design as well as accurate rotordynamic analysis and prediction of its dynamic behavior to secure the operating reliability. Rotordaynamic analyses of the IGCC rotor-bearing system predicted that the low speed pinion rotor mounted on 5-pad tilting pad bearings has two critical speeds before its design speed and high speed pinion rotor only one critical speed, and estimated critical speeds of both pinion shafts are away from the continuous operating speed enough to satisfy the corresponding API requirement. The forced response analysis with API specified maximum allowable unbalances also showed that unbalance responses are small enough for smooth operation of the system.

  • PDF

감육 배관의 다양한 보강 형태에 따른 이론적 등가 강성 검증 (Analytical Equivalent Stiffness Analysis for Various Reinforcements of Wall-thinned Pipe)

  • 장제훈;김지수;김윤재
    • 한국압력기기공학회 논문집
    • /
    • 제18권1호
    • /
    • pp.11-18
    • /
    • 2022
  • When wall-thinning in a pipe occurs during operation of nuclear power plant, reinforcement of the pipe needs to be performed. Accordingly, the structural response of the piping system due to introduction of the reinforcement may be re-evaluated. For elastic structural analysis of the piping system with the reinforced pipe using finite element (FE) analysis, the stiffness of the reinforced pipe is needed. In this study, the stiffness matrix of wall-thinned pipe with pad reinforcement or composite reinforcement is analytically derived. The validity of the proposed equations is checked by comparing with systematic finite element (FE) analysis results.