• Title/Summary/Keyword: PACS+

Search Result 472, Processing Time 0.036 seconds

Development of Image Quality Measurement Method of Coronary Angiography Using Image Analysis Program (영상 분석 프로그램을 이용한 관상동맥 혈관 조영상의 화질 측정 방법 고안)

  • Seo, Young-Hyun;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.111-120
    • /
    • 2020
  • Research should be actively conducted for the ability of X-ray equipment and Retrospective image analysis of X-ray equipment used in hospitals. Retrospective image analysis of X-ray machines, CT and MRI of radiology and medical equipment has been actively conducted. However, image quality measurement using angiography equipment of angiography room is mostly measured with phantom, and image quality measurement on image after being taken by actual patient is insufficient and researches on accurate image quality measurement method are remarkable. It is in short supply. Therefore, through this study, the researcher devised a method to measure the image quality of the acquired image after coronary angiography, and to provide a high quality image to the operator. The equipment and programs used were angiographic examination equipment (Axiom Artis Zee Ceiling) and Image J program. Subjects were images automatically saved in PACS program after coronary angiography.For image quality measurement, selected the AP Caudal 30° image that show the LCA vessel well and the LAO 30° image that show the RCA vessel well during the coronary angiography. In order to measure the background and ROI of the selected image by selecting an image, a criterion on how to find and measure a section where the overlap of the shadow, such as blood vessel, liver and lung is minimized, is presented. In conclusion, there is no exact standard for analyzing an image quality measurement method of angiography image. Therefore, in order to provide quality images to the practistioners, not only the technicians of the equipment but also the users who actually use them should become researchers and conduct research on image quality measurement in various ways. Thus, it is expected to provide excellent images to patients.

CT Number Measurement of Residual Foreign Bodies in Face (안면부에 잔류된 다양한 이물질을 측정한 CT 계수)

  • Wee, Syeo Young;Choi, Hwan Jun;Kim, Mi Sun;Choi, Chang Yong
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.423-430
    • /
    • 2008
  • Purpose: Computed tomography theoretically should improve detection of foreign bodies and provide more information of adjacent soft tissues. And the CT scanner and PACS program proved to be an excellent instrument for detection and localization of most facial foreign bodies above certain minimum levels of detectability. The severity of injury in penetrating trauma to the face, it is often underestimated by physical examination. Diagnosis of a retained foreign object is always critical. Methods: From March, 2005 to February 2008 a study was done with 200 patients who had facial trauma. Axial and coronal CT images were obtained with a General Electric(Milwaukee, Wis) 9800 CT scanner at 130 kV, 90 mA, with a 2-mm section thickness and a $512{\times}512$ matrix. Results: Axial and coronal CT images at various window widths should be used as the first imaging modality to detect facial foreign bodies. The attenuation coefficients for the metallic and nonmetallic foreign bodies ranged from -437 to +3071 HU. As a general rule, metallic foreign bodies produced more Hounsfield artifacts than nonmetallic foreign bodies, thus providing a clue to their composition. All of the metallic foreign bodies were represented by a single peak and had a maximum attenuation coefficient of +3071 HU. Of the nonmetallic foreign bodies, glass had an attenuation coefficient that ranged from +105 to +2039, while plastic had a much lower coefficient that ranged from -62 to -35. wood had the lowest range of attenuation coefficients: -491 to -437. Conclusion: The PACS program allows one to distinguish metallic from nonmetallic foreign bodies and to individually identify the specific composition of many nonmetallic foreign bodies. This program does not, however, allow identification of the specific composition of a metallic foreign body. We recommend this type of software program for CT scanning of any patient with an injury to the face in which a foreign body is suspected.

Effect of Head Positioning in Panoramic Radiography on the Vertical and Horizontal Magnification : Displacement along the Sagittal and Transverse Plane (파노라마방사선사진에서 환자의 머리 위치가 하악 수직, 수평 확대율에 미치는 영향 : 전후방 및 좌우 이동)

  • Kim, Yong-Gun;Lee, Young-Kyun;An, Seo-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.249-258
    • /
    • 2013
  • The purpose of this study was to investigate how image magnification in dental panoramic radiography is influenced by object position. Five metal balls (4 mm in diameter, 2 for the anterior and 3 for the posterior region on the right side) were placed above alveolar crest of dry skull considering extraction socket and dental arch. Dry skull was radiographed using OP-100D (Instrumentarium Imaging Co., Tuusula, Finland) at proper and displaced position along the sagittal and transverse plane at 3 mm, 6 mm, 9 mm, 12 mm and 15 mm using special mount which can control precise movement. Images were stored in DICOM files and were measured by ruler equipped within INFINITT PACS software (Infinitt Co., Ltd., Seoul, Korea). The mean horizontal magnification was 1.224-1.439 and mean vertical magnification was 1.286 - 1.345 at proper position. Vertical magnification resulted in less variation (1.245-1.418) than horizontal magnification (0.798-6.297) according to the sagittal and transverse displacements. Head positioning is important for linear measurement on panoramic radiography and inclusion of standard object (for instance, metal ball) is helpful to anticipate exact magnification of panoramic radiographs at various location.

The Performance of Pollutant Removal Using Nonpoint Treatment Filtration Device and Analysis of the Filter Backwashing Effect (여과형 비점오염 처리장치의 오염물질 제거특성 및 역세척 분석)

  • Lee, Jun-ho;Yang, Seung-ho;Bang, Ki-woong
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.5
    • /
    • pp.523-532
    • /
    • 2015
  • Hydrocyclone is widely used in industry, for its simple design, high capacity, low maintenance and low operational cost. The objective of this study is to develop hydrocyclone coagulation and filtration system. The system is made of hydrocyclone ballasted coagulation with polyaluminium chloride silicate (PACS) and upflow filter to treat micro particles in urban storm runoff. Roadside sediment particles (< $200{\mu}m$) was mixed with tap water to make various turbid suspensions to simulate urban storm runoff. The filter cartridge was filled with polyethylene media system and ran 1hr per everyday and total operation time were 8.19hrs and backwashing everyday after end of operation. The operation condition of flowrate was $8.2{\sim}11.9m^3/day$ (mean $10.1m^3/day$) and surface overflow rate (SOR) based on filter surface area was $45.5{\sim}65.9m^3/m^2/day$ (mean $55.7m^3/m^2/day$). The range of PACS dosage concentration was 14.0~31.5 mg/L. As the results of operation, the range of removal efficiency of turbidity, SS were 81.0~95.8% (mean 89.5%) 81.8~99.0% (mean 91.4%), respectively. An increase of filtration basin retention time brought on increased of removal efficiency of turbidity and SS, and increase of SOR brought on decreased of removal efficiency. During the first flush in urban area, storm runoff have an high concentration of SS (200~600 mg/L) and the filtration bed becomes clogged and decreased of removal efficiency. Backwashing begins when the drainage pipe valve at the filtration tank bottom is completely open (backwashing stage 1). Backwashing stage 2 was using air bubbles and water jet washing the media for 5 mins and open the drainage valve. After backwashing stage 1, 2, 61.83~64.04%, 18.53~27.51% of SS loading was discharged from filtration tank, respectively. Discharged SS loading from effluent was 7.12~14.79% and the range of residual SS loading in fliter was 2.26~5.00%. The backwashing effects for turbidity, SS were 89.5%, 91.4%, respectively. The hydrocyclone coagulation and filtration with backwashing system, which came out to solve the problems of the costly exchange filter media, and low efficiency of removing micro particles of filter type nonpoint treatment devices, is considered as an alternative system.

Development of a Method for Measuring Image Quality of Intra Vascular Ultrasound Images using Image Analysis Program (영상 분석 프로그램을 이용한 혈관 내 초음파 영상의 화질 측정 방법 고안)

  • Seo, Young-Hyun;Han, Jae-Bok;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.621-628
    • /
    • 2021
  • Prior studies on frequency-related image quality analysis of intravascular ultrasound catheters are lacking both in Korea and abroad. Therefore, this study was conducted to prepare a standard for measuring the image quality using the program and to suggest a measuring method to researchers related to the quality analysis of intravascular ultrasound images. For the target, the vessel lumen size is 3.0 - 4.0 mm. Before using intravascular ultrasound, thoroughly clean the ultrasound catheter so that no air or foreign substances enter it. Normal vascular images and lesion vascular images of sufficiently dilated images were used. As a standard image acquisition method, the image of the end-systolic section, which has the best evaluation of vascular lesions when using intravascular ultrasound, was acquired retrospectively through the DCAS PACS program to set the standard. When setting the measurement method criteria, we proposed a standard setting method that corresponds to the concentric and eccentric circles of normal and lesion vessels. By applying this criterion, we proposed a method for measuring the lumen and lateral cavities of normal and lesion vessels of interest and background area. In conclusion, if the image quality of intravascular ultrasonography is measured through the method devised by these researchers, consistent quality measurement is possible regardless of the type of intravascular ultrasound catheter. Therefore, it is thought that it can be applied as a guideline for the actual image quality measurement method in the study related to intravascular ultrasound image quality.

Evaluation of Distortion in Measuring the Stability of Distal Radio-ulnar Joint in Wrist PA-Grip View (Wrist PA-grip view에서 먼쪽노자관절의 안정성 정도 측정 시 왜곡도 평가)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.321-327
    • /
    • 2021
  • Wrist PA-grip view is used to diagnose triangular fibrocartilage complex (TFCC) tear because it can easily diagnose damage to the surrounding wrist ligaments. However, despite advances in radiology equipment, distortion of images due to geometric elements still has many limitations. In this paper, we propose a method that can minimize the distortions of images by analyzing the distortions occurring in the wrist PA-grip view. A source of image distance (SID) were set at 130 cm and 150 cm for comparison with 110 cm. Depending on the SID, the phantom of wrist was moved at 0, 2, 4, 6, 8, and 10 cm in the X-axis and Y-axis directions, respectively. For quantitative evaluation, the difference of distance between the radius and ulna was measured in picture archiving and communication system (PACS) system. As a qualitative evaluation, survey was conducted among 20 radiologic technologists who examined the Wrist PA-grip view. The Kruskal Wallis test was performed to compare the distortion according to the phantom movement in the X-axis and Y-axis directions based on the SID, and the Tukey test was performed as a post-test. In the quantitative evaluation results, the measured values obtained in the X-axis was not significantly different in all groups (p>0.05). The measured values obtained in the Y-axis was significantly different in the most groups (p<0.05). Therefore, to reduce distortion while maintaining image quality, we recommend what examine the SID at 150 cm than 110 cm.

THE SYNERGY OF LARGE AREA SURVEYS WITH AKARI AND HERSCHEL

  • Pearson, Chris;Serjeant, Stephen;Sedgwick, Chris;White, Glenn J.;Matsuhara, Hideo;Takagi, Toshinobu;Nagisa, Oi;Murata, Kazumi;Nakagawa, Takao;Yamamura, Issei
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.375-380
    • /
    • 2012
  • The Herschel Space Observatory is the European Space Agency's state of the art infrared space telescope launched into space on 14 May 2009, covering the wavelength range from 70-700 microns with 3 instruments SPIRE, PACS and HIFI. Large area surveys are being carried out by Herschel in the AKARI legacy fields at the North and South Ecliptic Poles and the AKARI All-Sky Survey provides additional synergy with the largest survey with Herschel, H-ATLAS, covering more than 500 square degrees. This paper reports on some of the early results of these synergies between Herschel and AKARI including the first comparison of the AKARI All-Sky Survey number counts with the deeper Herschel surveys.

Diagnostic Medical Image Compression Method using Visually Lossless Threshold on JPEG2000 (JPEG2000에서 시각적 무손실 임계값을 이용한 진단의료영상 압축기법)

  • Bong, Jeong-Sik;Yang, Gi-Joo;Jeon, Joon-Hyeon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.7C
    • /
    • pp.671-680
    • /
    • 2009
  • The diagnostic medical images(CT, MRI) in PACS require large storage and long transmission time. A simple and cheap way of overcoming these limitations is to increase the compression ratio. However, this requires a clinical validation for accurate diagnostic applications. The aim of this paper is to improve the compression efficiency of lossless JPEG2000 for diagnostic CT images by performing a visual-Iossless threshold filtering in high frequency subband. A proposed method, based on 5/3 reversible DWT, provides different subband-threshold values according to the compression ratio and gives the high subjective quality to reconstructed diagnostic CT images.

OH Emission toward Embedded YSOs

  • Yun, Hyeong-Sik;Lee, Jeong-Eun;Je, Hyerin;Lee, Seokho;Evans, Neal J. II;Wampfler, S.F.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.64.1-64.1
    • /
    • 2013
  • High energy photons and mechanical energy produced by the process of star formation result in copious FIR molecular and atomic lines, which are important coolants of the system. Photons thermally or mechanically induced could dissociate water in the dense envelope to change relative abundances among the species O, OH, and H2O. Here we analyze OH emission lines toward embedded young stellar objects (YSOs) observed as part of the Herschel open time key program, 'Dust, Ice, and Gas In Time (DIGIT)' in order to study the physical conditions of associated gas and the energy budget loaded on the OH line emission. According to our analysis of the Herschel/PACS spectra, OH emission peaks at the central spaxel in most of sources, but several sources show spatially extended emission structures. In the extended emission sources, the distribution of OH emission is correlated with that of [OI] emission and extended along the outflow directions. Considering the diversity of source properties, ratios between detected OH lines are relatively constant among sources. In addition, each OH line has strong correlation with bolometric luminosity. For detail analyses with rotation diagram and non-LTE LVG model, we present the results from GSS30-IRS1 and Elias29.

  • PDF

The Relation between AGN and Star Formation

  • Matsuoka, Kenta;Woo, Jong-Hak;Bae, Hyun-Jin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.48.2-48.2
    • /
    • 2013
  • To understand the connection between active galactic nuclei (AGNs) and star formation, we investigated the relation between AGN bolometric and far-infrared (FIR) luminosities, using type-2 AGNs. By matching type-2 AGNs at z < 0.3 selected from the SDSS based on the emission-line diagnostics, against the AKARI/FIS All-Sky Survey Catalogue and the COSMOS PEP (PACS Evolutionary Probe) Survey Catalogue, we obtained a sample of 729 type-2 AGNs detected in the AKARI survey ($90{\mu}m$) and 17 ones detected in the PEP survey ($100{\mu}m$). For AGN bolometric luminosities, we adopted an estimate based on the [OIII] and [OI] line luminosities. We confirmed that there is a correlation between the AGN bolometric and FIR luminosities with a large scatter, which is consistent with previous studies. However, we claim that this correlation suffers from various artificial effects, e.g., FIR detection limits, survey volumes, and so on. We will discuss the limitations of studying the connection between AGN and star formation using currently available facilities.

  • PDF