Compression of Medical Images Using DWT (DWT을 이용한 의료영상 압축)

  • Lim, Jae-Dong;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.2
    • /
    • pp.11-16
    • /
    • 2008
  • The most difficult of implementation PACS is large amount of data. Therefore, PACS needs mass storage, as well as rapid transmission time. Consequently, medical images needs compression when stored in PACS. WT(wavelet transform) was announced by Ingrid Daubechies and Stephane Mallat, WT was methods of signal analysis by a base functions set same as Fourie transform. This paper estimated an efficiency, that experimental medical images compressed by DWT. The result of estimated, we are knows effectiveness that display to remained signal in low frequency region after 4-level DWT form $512{\times}512{\times}2^8$ input images. Compression ratio of images by 4-level DWT was 1:16. It is a high compression ratio, the other side has a problem appears on staircase phenomenon.

  • PDF

흉부의 ANALOG-DIGITAL 영상에 대한 비교 평가

  • Jang, Yeong-Ae;Mun, Hui-Seok;Im, Han-Yeong;O, Hyeon-Ju;Kim, Seong-Su;Kim, Yeong-Il
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.2 no.1
    • /
    • pp.74-82
    • /
    • 1996
  • This paper were studied the evaluation in compare with the conventional and AMBER of analog images, PACS and CR of digital images which were collected every ten sampling chest images with the J.J.Vucicuh chest evaluated chart, and were measured the chest phantom surface dose and the density of several part in chest images. The evaluated numbers were total 22 persons who were 6 persons of the M.D., 6 of the radiotechnological professors and 10 of the radiotechnologists. The obtained results summarized as following : 1. Approaching the optimum standard density of the several part in chest images drew near at the lung round region density in PACS images, the sternum region density in CR and AMBER images, the heart region density in CR AMBER images, the diaphram region density in AMBER and conventional images. 2. The evaluation measured surface dose were appeared orderly lesser dose at the AMBER images (spine 21 mR, lung 2mR, heart 12mR, apex 6mR) than the conventional images(32 mR), CR images(38mR) and PACS images(81mR). 3. The anatomical physical evaluation marks were taken the highest points at CR images(88.3), and orderly PACS images(82), AMBER images(79.2) and conventional images(65.2). 4. It is exposured with lesser surface dose at the analog images, but analog images leaves much room for image quality improvement, and digital images demand for lesser exposure surface dose, although excellent image quality.

  • PDF

Design of Customized Medical Information Convergence System for the Glycosuria and Heart's Blood Patients (당뇨 및 심혈관 질환자를 위한 개인 맞춤형 의료정보 융합시스템 설계)

  • Kim, Gui-Jung;Han, Jung-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.9
    • /
    • pp.90-96
    • /
    • 2009
  • The aim of the research is that disease database of the glycosuria and heart's blood is designed to manage the condition of the glycosuria and heart's blood patients periodically and continuously. Also we integrate patient database of existing OCS, PACS, EMR, ERP etc. and support optimal service timely that the patients want through intelligent integrated interface environment. For this, we will develop customized medical information convergence system. We construct intelligent database for disease of the glycosuria and heart's blood. And we support data integration environment for connection with existing systems - OCS, EMR, PACS etc. Also, in consideration of QoS, reliability, and expandability of customized medical information convergence system, we will design H/W, S/W, and data compatibility method.

Evaluation of Standardized Uptake Value and Metabolic Tumor Volume between Reconstructed data and Re-sliced data in PET Study (PET 검사 시 Reconstructed data와 Re-sliced data의 표준섭취계수와 Metabolic Tumor Volume의 비교 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.3-8
    • /
    • 2016
  • Purpose SUV is one of the parameters that assist diagnosis in origin, metastasis and staging of cancer. Specially, it is important to compare SUV before and after chemo or radiation therapy to find out effectiveness of treatment. Storing PET data which has no quantitative change is needed for SUV comparison. However, there is a possibility to loss the data in external hard drive or MINIpacs that are managed by department of nuclear medicine. The aim of this study is to evaluate SUV and metabolic tumor volume (MTV) among reconstructed data (R-D) in workstation, R-D and re-sliced data (S-D) in PACS. Materials and Methods Data of 20 patients (aged $60.5{\pm}8.3y$) underwent $^{18}F-FDG$ PET (Biograph truepoint 40, mCT 40, mCT 64, mMR, Siemens) study were analysed. $SUV_{max}$, $SUV_{peak}$ and MTV were measured in liver, aorta and tumor after sending R-D in workstation, R-D and S-D in PACS to syngo.via software. Results R-D of workstation and PACS showed the same value as mean $SUV_{max}$ in liver, aorta and tumor were $2.95{\pm}0.59$, $2.35{\pm}0.61$, $10.36{\pm}6.15$ and $SUV_{peak}$ were $2.70{\pm}0.51$, $2.07{\pm}0.43$, $7.67{\pm}3.73$(p>0.05) respectively. Mean $SUV_{max}$ of S-D in PACS were decreased by 5.18%, 7.22%, 12.11% and $SUV_{peak}$ 2.61%, 3.63%, 10.07%(p<0.05). Correlation between R-D and S-D were $SUV_{max}$ 0.99, 0.96, 0.99 and $SUV_{peak}$ 0.99, 0.99, 0.99. And 2SD in balnd-altman analysis were $SUV_{max}$ 0.125, 0.290, 1.864 and $SUV_{peak}$ 0.053, 0.103, 0.826. MTV of R-D in workstation and PACS show the same value as $14.21{\pm}12.72cm^3$(p>0.05). MTV in PACS was decreased by 0.12% compared to R-D(p>0.05). Correlation and 2SD between R-D and S-D were 0.99 and 2.243. Conclusion $SUV_{max}$, $SUV_{peak}$, MTV showed the same value in both of R-D in workstation and PACS. However, there was statistically difference in $SUV_{max}$, $SUV_{peak}$ of S-D compare to R-D despite of high correlation. It is possible to analyse reliable pre and post SUV if storing R-D in main hospital PACS system.

  • PDF

Development of HIS System through the HL7-Based Combination of Legacy System (레거시 시스템과의 HL7 기반 연동을 통한 HIS 시스템 개발)

  • Lee Sang-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.9 no.3
    • /
    • pp.55-62
    • /
    • 2004
  • Tn the modern integrated healthcare environment, digital technology plays a critical role in the success of its operation. For overcoming the deteriorated healthcare management environment is to improve business service ability, cost and management efficiency through information processing of the business service process and the decision support system. For a solution of these problems, the Hospital Information System(HIS) was introduced. In this paper we proposed HIS system through the HL7-based with legacy system that improves both the efficiencies of medical of office and medical treatments. The implementation of HIS system enables combination of legacy systems including HL7 based OCS and PACS. And we proved the effective HIS development method provided by analysis of total module.

  • PDF

Medical Image Storage System based on Computational Grid (계산 그리드 기반 의료영상 저장시스템)

  • Ahn, Byoung-Kyu;Park, Jae-Hyun
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.10
    • /
    • pp.715-723
    • /
    • 2009
  • The use of medical imaging in hospitals is being gradually increased as it is of utmost importance in treatment and diagnosis of patients. With the drastic increase of the usage of medical imaging in hospitals per day necessitates more speedy and accurate systems for precise diagnosis and the treatment. Hence the modality and development of network infrastructure are also need to be improved day by day and this trend may be continued. Thus there is a great need improvement of PACS concerned. In this paper, by using the computational grid technology, we design a medical image storage system that improve the compression speed, and implement a prototype as a part of PACS. We also demonstrate the performance improvement from experimental results of the prototype.

Positive Research of Client-Server Interlock System for m-PACS Rehalibitated Service in Wire less Mobile Environment (무선이동환경에서 m-PACS 재활지원 서비스를 위한 클라이언트-서버 연동시스템의 실증적연구)

  • Kim, Whi-Young;Choe, Jin-Yeong;Park, Seong-Jun;Kim, Jin-Yeong;Park, Seong-Jun;Kim, Hui-Je
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2169-2170
    • /
    • 2006
  • J2ME service technology has advantage that can embody independent and, more soft system in DICOM 3.0 and medicine reflex administration server, client's OS that is medical treatment reflex standard in radio Internet. Also, intranet that do web basedspread, and develop by system that can alternate existent client-server structure rapidly. Specially, posibility of improvement is much because is connecting being limited in internet environment that medical equipment and information system of various kinds of machine are wire in medical institution and so on. Because do medical treatment reflex transmission module development applying DICOM technology and filtering techniques of "m-PACS Rehalibitated " in this research, existence, by interlock in radio usable Mobile reflex conversion system design and embody. That is, patient's information which is stored to various systems to be transmited and can give big help in medical examination and treatment to reflex client without being wooed doctor's interpretation result and so on in place through environment to be radish tentacle bar see

  • PDF

Development of Online Realtime Positioning Error Compensation System for CNC Machine Tools (CNC 공작기계용 온라인 실시간 위치오차 보정시스템의 개발)

  • Chung, Chae-Il;Kim, Jong-Won;Nam, Weon-Woo;Lee, Sang-Jo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.10
    • /
    • pp.45-52
    • /
    • 1999
  • The online realtime positioning error compensation system 'SKY-PACS' is developed to correct geometric errors, thermal errors and tool deflection errors induced by cutting forces on the vertical machining center. 'SKY-PACS' communicates position commands and position compensation signals with the CNC controller at 100Hz, which is CNC control frequency. So the compensation procedure can be applied during axis movement. Using 'SKY-PACS', Maximum 1 axis positioning accuracy was corrected from 5{\mu}m$ to 2{\mu}m$and the squareness error of X-Y table was corrected from 51{\mu}m$/m to below 4{\mu}m$/m. The error compensation under the cutting condition is carried out by ISO10791-7. And the measurement of test-pieces shows that the roundness is corrected rom 8{\mu}m$ to below 5{\mu}m$.

  • PDF

Design of DICOM Standard Interface Module for Medical Image Standardization (의료영상 표준화를 위한 DICOM 표준 인터페이스 모듈 설계)

  • Kim, Sung-Hyun;Jeon, Jae-Hwan;Kim, Gwan-Hyung;Kang, Sung-In;Oh, Am-Suk
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2010.07a
    • /
    • pp.221-224
    • /
    • 2010
  • PACS(Picture Archiving Communication System)를 바탕으로 하는 DICOM(Digital Imaging and Communications in Medicine)은 주요 의료영상장비들 사이에 데이터와 영상을 효율적으로 교환하고 전송할 수 있도록 마련한 표준안으로 현재 대부분의 최신형 의료영상장비(CT, MR, DSA, CR(Computed Radiology), 초음파검사, 핵의학검사, 내시경검사, 조직병리검사, 등)들은 의료 영상 분야의 국제 표준인 DICOM 표준방식에 의해 영상을 제공하고 있다. 최근 이러한 의료영상장비들은 독립적으로 사용하기보다는 의료수술 모니터링 장비 등의 비 의학영상장비와 서로 연계하여 사용하는 경우가 많아졌다. 그러나 이러한 의료수술 모니터링 장비들은 DICOM 표준 데이터를 고려하지 못하므로 PACS를 통한 데이터 연계에 어려움이 있다. 따라서 본 논문에서는 표준 DICOM 포맷과 의료수술 모니터링 장비의 데이터 구조를 분석하여 non-DICOM 의료수술 모니터링 장비의 PACS 연동을 위한 방안을 제안하였다.

  • PDF

A Study on the Removal of Algae by Coagulation and Sedimentation in the Rew Water of the Nakdong River (낙동강 원수내 조류의 응집 침전에 의한 제거에 관한 연구)

  • 이진희;김영주
    • Journal of Environmental Science International
    • /
    • v.10 no.2
    • /
    • pp.113-117
    • /
    • 2001
  • This study was conducted to investigate the effect of the prechlorination on algal removal by application of a varying amount of different coagulants, such as LAC, PAC, PACS following the process of coagulation and sedimentation of algae in the Nakdong River. The samples used as a source for the raw water of the Nakdong River were collected from the D Water Purification Plant in Taegu city. With the application of the process of prechlorination, the removal rate of the algae was increased from 10~25% for Synedra spp., 20~35% for diatoms and 4~17% for turbidity. Generally, the removal rate of the algae was increased with the increase of the concentration of the coagulants. The PAC and PACS showed 5% higher removal rate for turbidity as compared to the LAS. On the hand, LAS showed 12% higher removal rate for Synedra spp. as compared to the PAC and PACS. The variations in the removal rate of diatoms with the change of coagulant were not significant. In conclusion, the application of LAS, polymeric coagulant and chlorination for at least 20 minutes could be considered as a reliable treatment process for the removal of source water containing a variety of algae.