• Title/Summary/Keyword: P2P Grid

Search Result 203, Processing Time 0.024 seconds

The a-Si:H/poly-Si Heterojunction Solar Cells

  • Kim, Sang-Su;Kim, do-Young;Lim, Dong-Gun;Junsin Yi;Lee, Jae-Choon;Lim, Koeng-Su
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.5
    • /
    • pp.65-71
    • /
    • 1997
  • We present heterojunction solar cells with a structure of metal/a-Si:H(n-i-p)/poly-Si(n-p)/metal for the terrestrial applications. This cell consists fo two component cells: a top n-i-p junction a-Si:Hi cell with wide-bandgap 1.8eV and a bottom n-p junction poly-Si cell with narrow-bandgap 1.1eV. The efficiency influencing factors of the solar cell were investigated in terms of simulation an experiment. Three main topics of the investigated study were the bottom cell with n-p junction poly-Si, the top a-Si:H cell with n-i-p junction, and the interface layer effects of heterojunction cell. The efficiency of bottom cell was improved with a pretreatment temperature of 900$^{\circ}C$, surface polishing, emitter thickness of 0.43$\mu\textrm{m}$, top Yb metal, and grid finger shading of 7% coverage. The process optimized cell showed a conversion efficiency about 16%. Top cell was grown by suing a photo-CVD system which gave an ion damage free and good p/i-a-Si:H layer interface. The heterojunction interface effect was examined with three different surface states; a chemical passivation, thermal oxide passivation, and Yb metal. the oxide passivated cell exhibited the higher photocurrent generation and better spectral response.

  • PDF

Effects of Indoor Horticultural Activities on Improvement of Attention and Concentration in Elementary School Students (실내 원예활동이 초등학생의 주의집중력 향상에 미치는 영향)

  • Lee, Min Jung;Kim, Jiseon;Oh, Wook;Jang, Ja Soon
    • Horticultural Science & Technology
    • /
    • v.31 no.6
    • /
    • pp.821-827
    • /
    • 2013
  • The purpose of this study was to investigate the effects of three kinds of horticultural activities (HAs) on attention concentration of elementary students. We selected 20 students using a Wee Class counseling office at J elementary school in Yeongcheon, and divided them into experimental and control groups composed of ten students each. The experimental group participated in three HAs including flower arrangement, planting, and pressed flower. Each HA was composed of three sessions and a session proceeded for a week. For the examinations of attention concentration, two groups responded the questionnaires before a week of the first session and at the end of the 9th session, only the experimental group participated in the measurement using grid by Harris before a week of the first session and at the end of each HA every week. The results of questionnaire survey showed that the scores of problem in emotion and problem in controlling, and the total score decreased 9.2, 7.8, and 19.0 points, respectively (P < 0.05), indicating that the attention concentration of the experimental group improved compared with the control. In the measurements using grid by Harris, the flower arrangement, planting, and pressed flower activities increased the scores by 2.22, 2.49, and 2.41 points compared with the pre-HA of 6.00, respectively (P < 0.05), that means the improvements of attention concentration. At the post-HAs, the flower arrangement, planting, and pressed flower activities increased the scores by 1.12, 1.39 and 1.31 points compared with the control group of 7.10, respectively (P < 0.05). In conclusion, the indoor HAs improved the attention and concentration of elementary students irrespective of kind of activities.

Study of Rainfall-Runoff Variation by Grid Size and Critical Area (격자크기와 임계면적에 따른 홍수유출특성 변화)

  • Ahn, Seung-Seop;Lee, Jeung-Seok;Jung, Do-Joon;Han, Ho-Chul
    • Journal of Environmental Science International
    • /
    • v.16 no.4
    • /
    • pp.523-532
    • /
    • 2007
  • This study utilized the 1/25,000 topographic map of the upper area from the Geum-ho watermark located at the middle of Geum-ho river from the National Geographic Information Institute. For the analysis, first, the influence of the size of critical area to the hydro topographic factors was examined changing grid size to $10m{\times}10m,\;30m{\times}30m\;and\;50m{\times}50m$, and the critical area for the formation of a river to $0.01km^2{\sim}0.50km^2$. It is known from the examination result of watershed morphology according to the grid size that the smaller grid size, the better resolution and accuracy. And it is found, from the analysis result of the degree of the river according to the minimum critical area for each grid size, that the grid size does not affect on the degree of the river, and the number of rivers with 2nd and higher degree does not show remarkable difference while there is big difference in the number of 1st degree rivers. From the results above, it is thought that the critical area of $0.15km^2{\sim}0.20km^2$ is appropriate for formation of a river being irrelevant to the grid size in extraction of hydro topographic parameters that are used in the runoff analysis model using topographic maps. Therefore, the GIUH model applied analysis results by use of the river level difference law proposed in this study for the explanation on the outflow response-changing characters according to the decision of a critical value of a minimum level difference river, showed that, since an ogival occurrence time and an ogival flow volume are very significant in a flood occurrence in case of not undertow facilities, the researcher could obtain a good result for the forecast of river outflow when considering a convenient application of the model and an easy acquisition of data, so it's judged that this model is proper as an algorism for the decision of a critical value of a river basin.

A Study on the Comparison of Reliability for Protective Coordination of Loop Power Distributions using Communication of Circuit Breaker and Recloser (차단기와 리클로져의 통신을 이용한 루프 배전계통의 보호협조 적용시 신뢰도 비교에 관한 연구)

  • Lee, Hee-Tae;Moon, Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.3
    • /
    • pp.133-137
    • /
    • 2011
  • The purpose of smart grid is the low $CO_2$ through expansion of renewable energy. To achieve the purpose of smart grid, typical radial power distribution system will be changed to loop power distribution system. The loop power distribution system have many advantages such as low power loss, low voltage drop, and increase of connection of renewable energy. In this paper, the algorithm for minimization of interrupted section of power distribution system is proposed through communication between circuit breaker and recloser in loop power distribution system. The proposed algorithm is proved through case studies about reliability evaluation

Electrical Performance Characteristics of 200W PEM-Type Fuel Cells with Variations on Mass Flow Rate and Stack Temperature (공급유량 및 스택온도의 변이에 따른 200W급 PEM형 연료전지의 전기적 성능특성)

  • Hong, Kyung-Jin;Park, Se-Joon;Choi, Yong-Sung;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.563-567
    • /
    • 2009
  • The polymer electrolyte membrane fuel cell(PEMFC) with the advantages of low-operating temperature, high current density, low cost and volume, fast start-up ability, and suitability for discontinuous operation becomes the most reasonable and attractive power system for transportation vehicle and micro-grid power plant in a household. 200W PEM-type FCs system was integrated by this study, then the electrical characteristics and diagnosis of the fuel cell were analyzed with variations on mass flow rate and stack temperature. The ranges of the variations are 1~8L/min on $H_2$ volume and $20{\sim}70^{\circ}C$ on stack temperature.

A Study on the Experimental Fabrication and Analysis of MOS Photovoltaic Solar Energy Conversion Device (MOS 광전변화소자의 식적에 관한 연구)

  • Ko, Gi-Man;Park, Sung-Hui;Sung, Man-Young
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.6
    • /
    • pp.203-211
    • /
    • 1984
  • MOS silicon solar cells have been developed using the fixed (interface) charge inherent to thermally oxidized silicon to induce an n-type inversion layer in 1-10 ohm-cm p-type silicon. Higher collection efficiencies are predicted than for diffused junction cells. Without special precautions a conversion efficiency of 14.2% is obtained. A MOS silicon solar cell is described in which an inversion layer forms the active area which is then contacted by means of a MOS grid. The highest efficiency is obtained when the resistivity of the substrate is high.

  • PDF

L(3, 2, 1)-LABELING FOR CYLINDRICAL GRID: THE CARTESIAN PRODUCT OF A PATH AND A CYCLE

  • Kim, Byeong Moon;Hwang, Woonjae;Song, Byung Chul
    • Korean Journal of Mathematics
    • /
    • v.25 no.2
    • /
    • pp.279-301
    • /
    • 2017
  • An L(3, 2, 1)-labeling for the graph G = (V, E) is an assignment f of a label to each vertices of G such that ${\mid}f(u)-f({\upsilon}){\mid}{\geq}4-k$ when $dist(u,{\upsilon})=k{\leq}3$. The L(3, 2, 1)-labeling number, denoted by ${\lambda}_{3,2,1}(G)$, for G is the smallest number N such that there is an L(3, 2, 1)-labeling for G with span N. In this paper, we compute the L(3, 2, 1)-labeling number ${\lambda}_{3,2,1}(G)$ when G is a cylindrical grid, which is the cartesian product $P_m{\Box}C_n$ of the path and the cycle, when $m{\geq}4$ and $n{\geq}138$. Especially when n is a multiple of 4, or m = 4 and n is a multiple of 6, then we have ${\lambda}_{3,2,1}(G)=11$. Otherwise ${\lambda}_{3,2,1}(G)=12$.

Design and Implementation of a Globus-based Distributed Web Crawler Manager on Grid Environment (글로버스 기반 그리드 환경에서의 분산 웹 크롤러 매니저 설계 및 구현)

  • Kim, Hyuk-Ho;Lee, Seung-Ha;Park, Chan-Ho;Kim, Yang-Woo;Lee, Phil-Woo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.05a
    • /
    • pp.945-948
    • /
    • 2005
  • 그리드 정보검색 시스템은 일반적인 정보검색 시스템의 문제점과 한계점을 인식하고, 그리드라는 분산처리 환경을 기반으로 정보검색 시스템을 구축함으로써 보다 효율적이고 유연한 확장성을 갖는 정보검색 서비스를 제공한다. 본 논문에서는 그리드 시스템 환경에 맞게 그리드 미들웨어 중에 하나인 글로버스 툴킷(Globus Toolkit)을 이용하여 정보검색을 위한 가상 조직(VO: Virtual Organization)을 구성했다. 그리고 그리드 정보검색을 위한 전단계로 웹상에서 각종 정보를 수집하는 P2P 기반 분산 크롤러들을 관리하는 크롤러 매니저를 그리드 서비스로 설계 및 구현하여 그리드 정보검색 시스템에 존재하는 다른 서비스들과 함께 활용할 수 있도록 하였다.

  • PDF

A Peer-to-Peer based Replication Strategy for Data Grid (데이터 그리드를 위한 Peer-to-Peer기반 복제 정책)

  • 오상원;이원주;전창호
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10a
    • /
    • pp.49-51
    • /
    • 2004
  • 데이터 그리드를 위한 기존의 복제 정책은 계층적 구조를 기반으로 하고 있기 때문에 상위계승에서 하위계층으로만 데이터를 복제할 수 있어 비효율적이다. 따라서 본 논문에서는 기존 데이터 그리드의 계층적 구조에 P2P(Peer-to-Peer)시스템을 적용하여 효율적으로 복제본을 유지할 수 있는 새로운 복제 정책을 제안한다. 이 정책의 특징은 클라이언트 노드의 저장 공간 일정 부분을 임계 구역(critical section)으로 지정하여 데이터 조작을 방지함으로써 클라이언트 노드도 데이터 복제본을 저장할 수 있는 기능을 가지도록 한 것이다. 따라서 계층적 구조에서 상위 계층뿐만 아니라 동일 계층 또는 클라이언트 노드들 간의 데이터 전송이 가능하기 때문에 데이터 그리드의 성능을 향상시킬 수 있다.

  • PDF

A Control Method and Test Results of Utility-Interactive Photovoltaic Power Generation Systems (계통연계 태양광발전시스템의 제어기법 및 연계운전특성)

  • 황인호;안교상;임희천;김신섭
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.123-129
    • /
    • 2000
  • This paper desclibes a design method and test results of grid-connected photovoltaic power 당eneration s systems, which consists of solar cells, DCI AC inverter, utility grid. A 50 kW photovoltaic power generation s system including a 3-phase DCI AC inverter is designed and made in order to investigate the system l pelionnance for glid connection. Also the control scheme of a three phase cmrent-controlled PWM inverter W with PI controller is presented by using d-q transformation. The experimental waveforms show that the p proposed system has stable behavior with em unit power factor in utility-interactive operation.

  • PDF