• Title/Summary/Keyword: P-max

Search Result 1,554, Processing Time 0.035 seconds

Shear Bond Strength of Resin Cements on the IPS e.max Press (IPS e.max Press에 대한 수종 레진 시멘트의 전단결합강도에 관한 연구)

  • Lee, Kyung-Eun;Kim, Yu-Lee;Shin, Chang-Yong;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.311-322
    • /
    • 2010
  • The purpose of this study was to evaluate the bond strengths between IPS e.max Press and four different types of resin cements that often used for esthetic restoration. Disc shaped IPS e.max Press blocks(N=40, diameter: 12mm, thickness: 3mm) were fabricated according to the manufacture's instruction and cleaned with ultrasonic cleaner. They were embedded into an autopolymerizing acrylic resin. Fourty cylinder shaped resin block(Filtek Z350, diameter: 4.5mm, thickness: 3mm) were fabricated using a plastic tube. Each specimens were randomly divided into 4 experimental group and bonded each other using 4 different resin cements(Variolink II(light-cure), Variolink II(dual-cure), Calibra, Super-Bond C&B) according to the manufactures' recommendations. All the specimens were stored in normal saline at $37^{\circ}C$ for 24 hours before test. Universal testing machine at a crosshead speed of 1mm/min was used to evaluate the shear bond strength. The data were statistically analyzed using one-way ANOVA(P<.01). Multiple comparison was done by the Tukey HSD test. The shear bond strength of Super-Bond C&B to e.max was significantly lower than those of Calibra, Variolink II(light-cure), Variolink II(dual-cure) (P<.01). The shear bond strength of Calibra, Variolink II(light-cure), Variolink II(dual-cure) to e.max were not significantly different. The shear bond strengths of light-cure/dual-cure cement were higher than that of self-cure cement.

Photosynthesis-Irradiance Relationship and Primary Production of Phytoplankton in Lake Gocheonam

  • Jung, Min-Kyung;Lee, Ok-Hee;Cho, Kyung-Je
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.4
    • /
    • pp.524-531
    • /
    • 2004
  • Photosynthetic activities and primary production of phytoplankton were investigated in Lake Gocheonam from October 1999 to August 2000. As an estuary lake with a barrage in the Southwestern coast of the Korean peninsula, the lake has received more attention after it became known as the habitat of large population of rare and endangered bird- Baikal Teal. As the lake had high algal biomass ranging from $20\mu{g}\;chl-aL^{-1}\;to\;125\mu{g}\;chl-aL^{-1}$ in average values and rich eutrophication indicator species, the freshwaters were in a very productive or hypertrophic state. In the results obtained from the phytoplankton incubation in the laboratory, the maximum photosynthetic rate $(P_{max})$ varied according to seasons and sampling stations. Photo- synthetic activities were higher during the warm season than the cold seasons and the serial order of $P_{max}$ was August dominated with Microcystis, April with Chlamydomonas and Nitzschia, October with Chlamydomonas and January with Stephanodiscus. The water of the lake was persistently turbid throughout the year due to strong winds from the adjacent sea. Despite the water turbidity, the phytoplankton productions estimated from a mathematical model had very broad range from 18mg C $m^{-2}day^{-1}\;to\;10,300mg\;C\;m^{-2}day^{-1}$.

Conjugated Oligomers Combining Fluorene and Thiophene Units : Towards Supramolecular Electronics

  • Leclere, Ph.;Surin, M.;Sonar, P.;Grimsdale, A.C.;Mllen, K.;Cavallini, M.;Biscarini, F.;Lazzaroni, R.
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.228-228
    • /
    • 2006
  • Conjugated oligomers, used as models for fluorene-thiophene copolymers, are compared in terms of the microscopic morphology of thin deposits and the optical properties. The AFM images and the solid-state absorption and emission spectra are interpreted in line with the structural data, in terms of the assembly of the conjugated molecules. The compound with a terthiophene central unit and fluorene end-groups shows well-defined monolayer-by-monolayer assembly into micrometer-long strip-like structures, with a crystalline herringbone-type organization within the monolayers. Polarized confocal microscopy indicates a strong orientation of the crystalline domains within the stripes. In contrast, the compound with a terfluorene central unit and thiophene end groups forms no textured aggregates. The difference in behavior between the two compounds most probably originates from their different capability of forming densely-packed assemblies of ${\pi-pi}$ interacting molecules. These assemblies are used as active elements in organic field effect transistors designed by using soft lithography technique.

  • PDF

Wet etching charicteristics of InP in InP/InGaAs HBTs and their fabrication (InP의 습식식각특성과 InP/lnGaAs HBT의 제작)

  • 김강대;박재홍;김용규;황성범;송정근
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.77-80
    • /
    • 2002
  • In this paper, InP-based HBTs have been optimally designed by numerical simulation and fabricated by the self-aligned process. The structure of HBT was designed in terms of the current gain*f$_{max}$ for the base and f$_{T}$*f$_{max}$ for the collector. The designed structure produced the current gain of about 50 and the cutoff frequency and the maximum oscillation frequency of 87GHz and 2940Hz respectively. In addition, we present a study of the vertical and lateral etching of InP with the mask sides parallel to the principal crystallographic axes, [0101 and (001). This etching characteristics arc used to fabricate self-aligned HBT structures with reduced parasitic effects.s.s.s.

  • PDF

Two-Input Max/Min Circuit for Fuzzy Inference System

  • P. Laipasu;A. Chaikla;A. Jaruwanawat;P. Pannil;Lee, T.;V. Riewruja
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.105.3-105
    • /
    • 2001
  • In this paper, a current mode two-input maximum (Max) and minimum (Min) operations scheme, which is a useful building block for analog fuzzy inference systems, is presented. The Max and Min operations are incorporated in the same scheme with parallel processing. The proposed scheme comprises a MOS class AB/B configuration and current mirrors. Its simple structure can provide a high efficiency. The performance of the scheme exhibits a very sharp transfer characteristic and high accuracy. The proposed scheme achieves a high-speed operation and is suitable for real-time systems. The simulation results verifying the performances of the scheme are agreed with the expected values.

  • PDF

Bioequivalence Study of Acetyl-L-Carnitine Tablets (아세틸-엘-카르니틴 정제의 생물학적 동등성 평가)

  • 박경미;이미경;신지영;임수정;임윤영;김종국;우종수
    • Biomolecules & Therapeutics
    • /
    • v.9 no.4
    • /
    • pp.285-290
    • /
    • 2001
  • Bioequivalence of two acetyl-1-carnitine tablets, test product (Carnitile tablet: Hanmi Pharm. Co., Ltd.) and reference product (Nicetil $e^{R}$ tablet: Dong-A Pharm. Co., Ltd.), was evaluated according to the guide- lines of Korea Food and Drug Administration (KFDA). Twenty-six healthy volunteers were divided randomly into two groups and administered the drug orally at the dose of 500 mg as acetyl-1-carnitine in a 2$\times$2 crossover study. Blood samples were taken at predetermined time intervals for 12 hours and the plasma concentration of acetyl-1-carnitine was determined using HPLC by derivatization with p-bromophenacyl bromide. The pearmacokinetic parameters (AU $C_{0-}$12h/ $C_{max}$ and $T_{max}$) were calculated and ANOVA was utilized for the statistical analysis of parameters. The apparent differences of these parameters between two drugs were less than 20% (i.e., 1.26,-5.08 and 8.59% for AU $C_{0-}$12h/ $C_{max}$ and $T_{max}$, respectively). The powers (1-$\beta$) for AU $C_{0-}$12h/ $C_{max}$ and $T_{max}$, and Tmax were over 0.9. Minimal detectable difference ($\Delta$) at $\alpha$=0.05, 1-$\beta$=0.8 were less than 20% (i.e.,7.31, 14.88 and 11.77% for AU $C_{0-}$12h/ $C_{max}$ and $T_{max}$, respectively). The confidence intervals ($\delta$) for these parameters were also within $\pm$ 20% (i.e.,-3.03$\leq$$\delta$$\leq$5.54, -13.80$\leq$$\delta$$\leq$3.64 and 1.69$\leq$$\delta$$\leq$15.48 for AU $C_{0-}$12h/ $C_{max}$ and $T_{max}$, respectively). These results satisfied the criteria of KFDA guideline for bioequivalence, indicating Carnitile bioequivalent to Nicetil $e^{R}$ .TEX>$^{R}$ .> R/ . R/ .

  • PDF

Bioeuqivalence Study of Nabumetone Tablets in Man

  • Lee, Young-Joo;Jang, Eun-Ju;Lee, Jeong-Uk;Han, Yong-Hae;Chung, Suk-Jae;Lee, Min-Hwa;Shim, Chang-Koo
    • Archives of Pharmacal Research
    • /
    • v.18 no.5
    • /
    • pp.340-345
    • /
    • 1995
  • A nebumetone tablet in development $(Navuton^R)$ was tested for its bioequivalence to the erference tablet $(Uniton^R)$. Seventeen healthy Korean male subjects participated in this study. Each subject received a 1-g dose of nabumetone (2tables each) in an unbalanced, randomized, two-way crossover investigation. Serum concentrations of 6-methoxy-2-na-phthylacetic acid (6-MNA), a major metabolite of nebumetone, were measured over 120 hr interval by a high-performance liquid chromatography. The maximum serum concentration $(C_{max})$ and time to reach the maximum concentration$(T_{max})$ were read directly, but area under the serum concentration time curve from time 0 to 120 hr (AUC) and mean residence time serum curves showed multiple peaks of 6-MNA in most subjects, and the $C_{max}$ and $T_{max}$ were read from the highest serum peaks. calculated bioavailability parameters for test and reference tablets were 148.6 : 1377.9 $\mug \cdot hr/ml$ for AUC; 25.2:23.1 $\mu/ml$ for $C_{max}$; 11.8:16.4 hr for $T_{max}$, and 42.6 : 43.8 hr for MRT, respectively. The paired t-test revealed no significant differences in all the parameters between the two tablets. Analysis ofl variance (ANOVA) revealed no significant differences between groups and formulations in all the parameters ($C_{max}$ and $T_{max}$, AUC and MRT) indicating the crossover design of the experiment was properly performed. But significant differences (p<0.05) between subject/groups and periods were found for all the parameters indicating substantial intersubject and interperiodic variations for these parameters.

  • PDF

Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department (핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석)

  • Chae, Hong Joo;Cheon, Jun Hong;Lee, Sun Ho;Yoo, So Yeon;Yoo, Seon Hee;Park, Ji Hye;Lim, Soo Yeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2019
  • Purpose In in-vitro laboratories of nuclear medicine department, when the reagent lot or reagent lot changes Comparability test or parallel test is performed to determine whether the results between lots are reliable. The most commonly used standard domestic laboratories is to obtain %difference from the difference in results between two lots of reagents, and then many laboratories are set the standard to less than 20% at low concentrations and less than 10% at medium and high concentrations. If the range is deviated from the standard, the test is considered failed and it is repeated until the result falls within the standard range. In this study, several tests are selected that are performed in nuclear medicine in-vitro laboratories to analyze parallel test results and to establish criteria for customized percent difference for each test. Materials and Methods From January to November 2018, the result of parallel test for reagent lot change is analyzed for 7 items including thyroid-stimulating hormone (TSH), free thyroxine (FT4), carcinoembryonic antigen (CEA), CA-125, prostate-specific antigen (PSA), HBs-Ab and Insulin. The RIA-MAT 280 system which adopted the principle of IRMA is used for TSH, FT4, CEA, CA-125 and PSA. TECAN automated dispensing equipment and GAMMA-10 is used to measure insulin test. For the test of HBs-Ab, HAMILTON automated dispensing equipment and Cobra Gamma ray measuring instrument are used. Separate reagent, customized calibrator and quality control materials are used in this experiment. Results 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(middle concentration) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [10.0 / 4.2 / 3.9 / 0.0] C-2(high concentration) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 4.3 / 4.3 / 0.3] C-2(high concentration) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(low concentration) [9.8 / 4.2 / 3.0 / 0.0] C-2(middle concentration) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [15.4 / 7.6 / 8.2 / 0.0] C-2(middle concentration) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 3.7 / 2.7 / 0.2] C-2(high concentration) [8.9 / 4.1 / 3.6 / 0.3] 7. Insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [8.7 / 3.1 / 2.4 / 0.9] C-2(high concentration) [8.3 / 3.2 / 1.5 / 0.1] In some low concentration measurements, the percent difference is found above 10 to nearly 15 percent in result of target value calculated at a lower concentration. In addition, when the value is measured after Standard level 6, which is the highest value of reagents in the dispensing sequence, the result would have been affected by a hook effect. Overall, there was no significant difference in lot change of quality control material (p-value>0.05). Conclusion Variations between reagent lots are not large in immunoradiometric assays. It is likely that this is due to the selection of items that have relatively high detection rate in the immunoradiometric method and several remeasurements. In most test results, the difference was less than 10 percent, which was within the standard range. TSH control level 1 and PSA control level 1, which have low concentration target value, exceeded 10 percent more than twice, but it did not result in a value that was near 20 percent. As a result, it is required to perform a longer period of observation for more homogenized average results and to obtain laboratory-specific acceptance criteria for each item. Also, it is advised to study observations considering various variables.

An Experimental Study on Heat Transfer in the Furan Foundry Sand Fluidized Bed (Furan Foundry Sand 유동층에서 열 전달 특성에 관한 연구)

  • Park, Jong-Suen;Baek, Ko-Kil;Kim, Uen-Young;Jeon, Sung-Taek;Lee, Duck- Bong
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.105-117
    • /
    • 1995
  • Heat transfer coefficients on a single spiral coil tube in the furan foundry sand fluidized bed have been investigated. Heat transfer coefficients(ho) to an immersed single spiral coil tube were measured in the bed. The bed diameter was 0.21 m. The following quantities were varied: (l)bed temperature, (2)mean particle diameter, (3) fluidization rate, (4)the ratio of heated coil tube pitch to diameter(p/Do), and (5)the ratio of heated coil tube pitch to mean particle diameter(p/dp). In addition, the experimental values of maximum Nusselts number were compared with the values of maximum Nusselts number predicted by the existing correlations. The values of heat transfer coefficient increase with the increase in bed temperature and fluidization rate, but decrease with increase in particle diameter. An empirical formulus of maximum Nusselts number which is applicable in the furan foundry sand fluidization bed is as follows: $$Nu_{max}=1.01\;Re^{0.48}Prg^{0.4}(p/dp)^{0.28}(p/Do)^{0.05}$$.

  • PDF

Analysis for Correlation of Standardized Uptake Value in Fusion Imaging Scanner (융합영상장비의 표준섭취계수 상관관계 분석)

  • Kim, Jin-Eui;Kim, Jung-Soo;Choi, Nam-Gil;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.593-601
    • /
    • 2018
  • Recently in nuclear medicine, to improve diagnostic value, SUV, semi-quantitative indicator used in PET-CT, is adopted in SPECT-CT. Therefore, this research analyzed correlation of $SUV_{max}$ of two scanners through phantom test, and evaluated possibility of clinical application. Radiopharmaceuticals ($^{18}F$, $^{99m}Tc$) were injected with the ratios of 8:1 and 4:1, considering background radioactivity, into the phantom manufactured with 6 globes of different sizes, and, based on clinical protocol, positive phases were acquired with PET-CT and SPECT-CT scanners, and interesting areas were divided into ROI and VOI, and $SUV_{max}$ of them were measured, and analyzed. Tests found out no statistically significant difference in $SUV_{max}$ measured with two scanners (P>0.05). Thus, $SUV_{max}$ of PET-CT and SPECT-CT had a certain correlation within significant levels, and were evaluated as the same. Accordingly, it seems that $SUV_{max}$ quantitative analysis using SPECT-CT can provide significant diagnostic information as the case of PET-CT.