• Title/Summary/Keyword: P-loop

Search Result 518, Processing Time 0.028 seconds

Current Source Disposition of Large-scale Network with Loop-reduction Drawing Technique (망축소작도법에 의한 대형회로망 전류원 처리)

  • Hwang, Jae-Ho
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.5
    • /
    • pp.278-286
    • /
    • 2000
  • A new large-scale network geometric analysis is introduced. For a large-scale circuit, it must be analyzed with a geometric diagram and figure. So many equations are induced from a geometric loop-node diagram. The results are arranged into a simple matrix, of course. In case of constructing a network diagram, it is not easy to handle voltage and current sources together. Geometric loop analysis is related to voltage sources, and node analysis is to current sources. The reciprocal transfer is possible only to have series or parallel impedance. If not having this impedance, in order to obtain equivalent circuit, many equations must be derived. In this paper a loop-reduction method is proposed. With this method current source branch is included into the other branch, and disappears in circuit diagram. So the number of independent circuit equations are reduced as much as that of current sources. The number is not (b-n+1), but (b-n+1-p). Where p is the number of current sources. The reduction procedure is verified with a geometric principle and circuit theory. A resultant matrix can be constructed directly from this diagram structure, not deriving circuit equations. We will obtain the last results with the help of a computer.

  • PDF

Controller Design of BLDC Motor Fin Position Servo System by Employing H-infinity Loop Shaping Method (H-infinity Loop Shaping 방법을 이용한 BLDC 전동기 핀 위치제어시스템 제어기 설계)

  • Zhu, He-Lin;Mok, Hyung-Soo;Lee, Hyeong-Geun;Han, Soo-Hee;Seo, Hyeon-Uk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.1
    • /
    • pp.49-55
    • /
    • 2019
  • This study proposes a robust control of a fin position servo system using the H-infinity loop-shaping method. The fin position control system has a proportional (P) position controller and a proportional-integral (PI) controller. In this work, the position control loop requires a wide bandwidth. No current control loop exists due to the compact design of the system. Hence, the controller parameters are difficult to determine using the traditional cascade design method. The $H_{\infty}$ controller design method is used to design the controller's gain to achieve good performance and robustness. First, the transfer function of the system, which can be divided into tunable and fixed parts, is derived. The tunable part includes the position P controller and speed PI controller. The fixed part includes the rest of the system. Second, the optimized controller parameters are calculated using Matlab $H_{\infty}$ controller design program. Finally, the system with optimized controller is tested by simulation and experiment. The control performance is satisfactory, and the $H_{\infty}$ controller design method is proven to be valid.

A Gain-Phase Loop Shaping Method of QFT using TLS (TLS를 이용한 QFT의 이득-위상 루프형성법)

  • Kim, Ju-Sik;Jeong, Su-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.2
    • /
    • pp.94-98
    • /
    • 2002
  • QFT(Quantitative Feedback Theory) is a very practical design technique that emphasizes the use of feedback for achieving the desired system performance tolerances in despite of plant uncertainty and disturbance. The gain-phase loop shaping procedure of QFT is employed to design controller, until the bounds at desired frequencies are satisfied. This paper presents a transfer function synthesis using TLS(Total Least Squares) and offers a loop shaping method with the suggested technique. An example illustrates a feasibility of the presented algorithm.

Design of Planar Modified Folded Loop Antennas for S-DMB band (위성 DMB 대역을 위한 수정된 폴디드 루프 안테나)

  • Lee, Hyeon-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.1-4
    • /
    • 2012
  • In this paper, the planar type modified folded loop antennas for S-DMB band is proposed. The proposed antenna consisted of opened center of a conventional closed loop and folded terminal of microstrip line to inside loop antenna. The sizes proposed antenna was minimized by folding the terminal of the loop. Also, It was minimized reactance value by increasing capacitances between coupled microstrip line. Therefore the proposed antennas compacted about 20% than a conventional loop antenna and increased efficiency of antenna. The proposed antennas got an omni-directional pattern, the antenna gain was 3.67 [dBi] and the bandwidth was 900 MHz (2.6-3.56 GHz) with VSWR${\leq}$2 from the simulated and the measured results. The frequency utilization coefficient was 29.9 %. These properties could satisfy the S-DMB band.

Application a Loop Compensation type 2-DOF PID Controller tuned by Neural Network to Gas Turbine Control Loop (가스터빈 제어 루프에 대한 신경망 튜닝 루프 보상형 2-자유도 PID 제어기의 응용)

  • Kim, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.781-786
    • /
    • 1998
  • Since a gas turbine is still a significant contributor to peak time, it is very important to tune the gains of P. I. D to get a maximum power and stability within permissible limits. In the gas turbine, the main control loop must adjust the fuel flow to ensure the correct output power and frequency. but it is not easy, because the control loop is composed of many subsystems. In this paper we acquire a transfer function based on the operations data of Gun-san gas turbine and study to apply a loop compensation type 2-DOF PID controller tuning by neural-network to control loop of gas turbine to reduce phenomena caused by integral and derivative actions through simulation. We obtained satisfactory results to disturbances of subcontrol loop such as, fuel flow, air flow, turbine extraction temperature.

  • PDF

An Effect of Car Performance Influenced to Absorbing Resistane of Air-cleaner Filter for the L. P. G Vehicle of Open Loop Fuel System (Open Loop 연료공급계의 L. P. G 차량에서 공기청정기 필터의 흡기저항이 차량성능에 미치는 영향)

  • Shin, Yong-Wha;Kim, Ki-Hyung;Jung, Jong-An
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.4
    • /
    • pp.36-46
    • /
    • 1995
  • The interest and purpose of this study is to control of air-fuel ratio and develop control device of a spark ignition LPG engine with adopting open loop fuel system. The air-fuel ratio is derived by considering airflow resistane of air cleaner element. The result shows that air-fuel ratio becomes more and more rich when airflow resistance increases. Experiments about the influence of airflow resistance on the engine performance, drivability and emissions are performed. Therefore, it is known that open-loop fuel system depends on the absorbing resistance of air-cleaner.

  • PDF

Modelling and LQG/LTR Compensator Design of the Seeker Scan-Loop (탐색기의 주사루프 모델링과 LQG/LTR보상기 설계)

  • 황홍연;이호평
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.11
    • /
    • pp.2730-2741
    • /
    • 1993
  • A mathematical model of the seeker scan-loop which is composed of a spin-stabilized gyroscope and its driving signal processors is derived. The derived model has a transmission zero pair on the imaginary axis near to the required bandwidth. The LQG/LTR design methodology is evolved for the derived scan-loop model. To implement the designed LQG/LTR compensator to the actual plant, the compensator order is reduced using the internally balanced realization method. The performances of the LQG/LTR compensator are tested and compared with those of the P-control. Especially, stability-robustnessexperiments for model uncertainties represented in the form of time-delays are performed. It is demonstrated that the LQG/STR compensator is actually very robust to model uncertainties.

Design of Robust Double Digital Controller to Improve Performance for UPS Inverter (UPS 인버터의 성능 개선을 위한 강인한 2중 디지털 제어기의 설계)

  • 박지호;노태균;김춘삼;안인모;우정인
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.116-127
    • /
    • 2003
  • In this paper, a new fully digital control method for UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an Internal model controller The Internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the simulation and experimental results respectively.

Reconfiguring Second-order Dynamic Systems via P-D Feedback Eigenstructure Assignment: A Parametric Method

  • Wang Guo-Sheng;Liang Bing;Duan Guang-Ren
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.1
    • /
    • pp.109-116
    • /
    • 2005
  • The design of reconfiguring a class of second-order dynamic systems via proportional plus derivative (P-D) feedback is considered. The aim is to resynthesize a P-D feedback controller such that the eigenvalues of the reconfigured closed-loop system can completely recover those of the original close-loop system, and make the corresponding eigenvectors of the former as close to those of the latter as possible. Based on a parametric result of P-D feedback eigenstructure assignment in second-order dynamic systems, parametric expressions for all the P-D feedback gains and all the closed-loop eigenvector matrices are established and a parametric algorithm for this reconfiguration design is proposed. The parametric algorithm offers all the degrees of design freedom, which can be further utilized to satisfy some additional performances in control system designs. This algorithm involves manipulations only on the original second-order system matrices, thus it is simple and convenient to use. An illustrative example and the simulation results show the simplicity and effect of the proposed parametric method.

The pollutants removal and disinfection of secondary effluent from sewage treatment plant in loop reactor using silver nanoparticles coated on activated carbon (은나노 활성탄을 이용한 Loop Reactor에서 하수 2차 처리수 중의 오염물질 제거 및 소독 효과)

  • Seon, Yong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.4
    • /
    • pp.361-367
    • /
    • 2016
  • Pollutants removal and disinfection effect of secondary effluent from final settling tank of sewage treatment plant of W city were investigated in Loop Reactor using ordinary granular activated carbon(GAC) and GAC coated with silver nanoparticles. The results showed that the removal efficiency of $COD_{Mn}$, T-N and T-P using GAC with silver nanoparticles were higher than using the ordinary GAC. The removal efficiency of T-P using GAC with silver nanoparticles is 45.4% and that of T-P using ordinary GAC is 30.9% in the same case of the input amount of 20 g/L of GAC. The total califorms is reduced according to increasing input amount of GAC with silver nanoparticles and ordinary GAC. The disinfection efficiency of total coliforms in case of GAC with silver nanoparticles is much higher than that in case of ordinary GAC. For all experiments using the silver nanoparticles, the total coliforms is under 26 cfu/mL and this shows very excellent disinfection effect.