• Title/Summary/Keyword: P-loop

Search Result 521, Processing Time 0.029 seconds

The study of the characteristic of the cylindrical dielectric resonator filter (원통형 유전체 공진기 필터 특성 연구)

  • 김주영;박도영;김종철;이기진
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.431-434
    • /
    • 2002
  • In this paper, The resonant frequencies of any modes in the dielectric resonator filter is determined by numberical analysis. The theoretical analysis for the dielectric resonator filter used Ansoft HFSS. We designed the dielectric resonator filter with resonant frequency 4.5 GHz. We describe the characteristics of delivering Power to resonator in different shaped coupling loops. Tile resonant mode of T $E_{01{\delta}}$ and T $E_{01{\delta}}$ could be selected by the horizontal and the vertical coupling loop.p.

  • PDF

A Study of Dietary Intakes and Nutritional Status after Total Gastrectomy of Early Gastric Cancer Patients (위전절제술을 시행한 조기위암환자의 식사섭취량과 영양상태에 관한 연구)

  • Kim, Ji-Yeong;Park, Mi-Seon;Lee, Yeong-Hui;Jo, Sam-Je;Yang, Han-Gwang
    • Journal of the Korean Dietetic Association
    • /
    • v.7 no.1
    • /
    • pp.72-79
    • /
    • 2001
  • The purpose of this study is to investigate the dietary intakes and nutritional status in total gastrectomized patients. We assessed the nutritional status by dietary intake, anthropometric data and biochemical data. And we also checked the subjective postprandial symptoms and gastrofiberscopy to detect the reflux esophagitis in 22 patients who were free of tumors for more than 1 year after total gastrectomy by the three different reconstruction methods(Loop esophagojejunostomy with A-loop tie/ Roux-en-Y esophagojejunostomy/Roux-en-Y esophagojejunostomy with Paulino pouch). Any patients were not in malnutrition status in respect to biochemical data. By assessing the dietary intake, the average daily calorie intake was 1848.2$\pm$440.2kcal, it was 105.9$\pm$23.8% of energy requirement. But there was weight loss in 21 patients of 22 patients after operation and the weight loss was 12.8% of preoperative weight(61.0$\pm$7.9 vs. 53.5$\pm$6.7kg, preoperatively vs. at the time of study). This may suggest that continuous nutritional care is necessary after total gastrectomy to promote sufficient calorie intake, keeping good nutritional state. There were no significant differences between the methods of reconstruction and dietary intakes or nutritional status. Endoscopic esophagitis was more frequently found in patients of loop esophagojejunostomy than any other reconstruction methods(p<0.001), but it didn't show any effect on the dietary intakes.

  • PDF

The Construction Work Completion of the Fuel Test Loop (핵연료 노내조사시험설비 설치공사 완료)

  • Park, Kook-Nam;Lee, Chung-Young;Chi, Dae-Young;Park, Su-Ki;Shim, Bong-Sik;Ahn, Sung-Ho;Kim, Hark-Rho;Lee, Jong-Min
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.291-295
    • /
    • 2007
  • FTL(Fuel Test Loop) is a facility that confirms performance of nuclear fuel at a similar irradiation condition with that of nuclear power plant. FTL consists of In-Pile Test Section (IPS) and Out-Pile System (OPS). FTL construction work began on August, 2006 and ended on March, 2007. During Construction, ensuring the worker's safety was the top priority and installation of the FTL without hampering the integrity of the HANARO was the next one. Task Force Team was organized to do a construction systematically and the communication between members of the task force team was done through the CoP(community of Practice) notice board provided by the Institute. The installation works were done successfully overcoming the difficulties such as on the limited space, on the radiation hazard inside the reactor pool, and finally on the shortening of the shut down period of the HANARO. Without a sweet of the workers of the participating company of HEC(Hyundae Engineering Co, Ltd), HDEC(HyunDai Engineering & Construction Co. Ltd), equipment manufacturer, and the task force team, it is not possible to install the FTL facility within the planned shutdown period. The Commissioning of the FTL is on due to check the function and the performance of the equipment and the overall system as well. The FTL shall start operation with high burn up test fuels in early 2008 if the commissioning and licensing progress on schedule.

  • PDF

Long-term Outcomes of a Loop Electrosurgical Excision Procedure for Cervical Intraepithelial Neoplasia in a High Incidence Country

  • Sangkarat, Suthi;Ruengkhachorn, Irene;Benjapibal, Mongkol;Laiwejpithaya, Somsak;Wongthiraporn, Weerasak;Rattanachaiyanont, Manee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.1035-1039
    • /
    • 2014
  • Aim: To evaluate the operative, oncologic and obstetric outcomes of the loop electrosurgical excision procedure (LEEP) in cases with cervical neoplasia. Materials and Methods: A retrospective cohort study was conducted on patients who were suspected of cervical neoplasia and therefore undergoing LEEP at Siriraj Hospital, Mahidol University, Thailand, during 1995-2000. Outcome measures included operative complications in 407 LEEP patients and long-term outcomes in the 248 patients with cervical intraepithelial neoplasia (CIN) who were treated with only LEEP. Results: There were 407 patients undergoing LEEP; their mean age was $39.7{\pm}10.5$ years. The histopathology of LEEP specimens revealed that 89 patients (21.9%) had lesions ${\leq}CIN$ I, 295 patients (72.5%) had CIN II or III, and 23 patients (5.6%) had invasive lesions. Operative complications were found in 15 patients and included bleeding (n=9), and infection (n=7). After diagnostic LEEP, 133 patients underwent hysterectomy as the definite treatment for cervical neoplasia. Of 248 CIN patients who had LEEP only, seven (2.8%) had suffered recurrence after a median of 16 (range 6-93) months; one had CIN I, one had CIN II, and five had CIN III. All of these recurrent patients achieved remission on surgical treatment with re-LEEP (n=6) or simple hysterectomy (n=1). A significant factor affecting recurrent disease was the LEEP margin involved with the lesion (p=0.05). Kaplan-Meier analysis showed 5-year and 10-year disease-free survival (DFS) estimates of 99.9%. Twelve patients became pregnant a total of 14 times, resulting in 12 term deliveries and two miscarriages - one of which was due to an incompetent cervix. Conclusions: LEEP for patients with cervical neoplasia delivers favorable surgical, oncologic and obstetric outcomes.

Dislication Loop Models for Plastic Deformation of the AI-5.5 at.%Mg alloy (AI-5.5at.%MG합금의 소성변형을 규명하기 위한 전위환 모델의 고찰)

  • An, Seong-Uk;Jeong, Seung-Bu
    • Korean Journal of Materials Research
    • /
    • v.4 no.3
    • /
    • pp.349-356
    • /
    • 1994
  • For the deformation, life time prediction and improvement of the life time in high temperature materials it's very important to know the mechanism of deformation. For these mechanisms the dislocation loop models of Orlova et al. and Mills et al. are used often now. But they show controversial differencies, even if they have unertaken similar experimental tests with the same alloy of A1-5.5at.% Mg. In this work also the similiar tests of them have done under the same temperature of 573 K ; (1) The specimen was deformed by $\sigma$= 30MPa and $\varepsilon$=0.03. (2) Direct after creep deformation of $\sigma$= 30MPa and $\sigma$= 0.03 the stress reduction tests to 15, 10 and OMPa have been performed. (3) To study the loop models dislocation structure and dislocation density ( p ) have been observed.

  • PDF

Modified Direct Torque Control using Algorithm Control of Stator Flux Estimation and Space Vector Modulation Based on Fuzzy Logic Control for Achieving High Performance from Induction Motors

  • Rashag, Hassan Farhan;Koh, S.P.;Abdalla, Ahmed N.;Tan, Nadia M.L.;Chong, K.H.
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.369-380
    • /
    • 2013
  • Direct torque control based on space vector modulation (SVM-DTC) protects the DTC transient merits. Furthermore, it creates better quality steady-state performance in a wide speed range. The modified method of DTC using SVM improves the electrical magnitudes of asynchronous machines, such as minimizing the stator current distortions, the stator flux with electromagnetic torque without ripple, the fast response of the rotor speed, and the constant switching frequency. In this paper, the proposed method is based on two new control strategies for direct torque control with space vector modulation. First, fuzzy logic control is used instead of the PI torque and a PI flux controller to minimizing the torque error and to achieve a constant switching frequency. The voltages in the direct and quadratic reference frame ($V_d$, $V_q$) are achieved by fuzzy logic control. In this scheme, the switching capability of the inverter is fully utilized, which improves the system performance. Second, the close loop of stator flux estimation based on the voltage model and a low pass filter is used to counteract the drawbacks in the open loop of the stator flux such as the problems saturation and dc drift. The response of this new control strategy is compared with DTC-SVM. The experimental and simulation results demonstrate that the proposed control topology outperforms the conventional DTC-SVM in terms of system robustness and eliminating the bad outcome of dc-offset.

A Design of DLL(Delay-Locked-Loop) with Low Power & High Speed locking Algorithm (저전력과 고속 록킹 알고리즘을 갖는 DLL(Delay-Locked LooP) 설계)

  • 경영자;이광희;손상희
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.12C
    • /
    • pp.255-260
    • /
    • 2001
  • This paper describes the design of the Register Controlled DLL(Delay-Locked Loop) that achieves fast locking and low Power consumption using a new locking algorithm. A fashion for a fast locking speed is that controls the two controller in sequence. The up/down signal due to clock skew between a internal and a external clock in phase detector, first adjusts a large phase difference in coarse controller and then adjusts a small phase difference in fine controller. A way for a low power consumption is that only operates one controller at once. Moreover the proposed DLL shows better jitter performance Because using the lock indicator circuit. The proposed DLL circuit is operated from 50MHz to 200MHz by SPICE simulation. The estimated power dissipation is 15mA at 200MHz in 3.3V operation. The locking time is within 7 cycle at all of operating frequency.

  • PDF

Mitogen-activated $p70^{s6k}$ signalling pathway

  • Han, Jeung-Whan
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.11a
    • /
    • pp.135-139
    • /
    • 1996
  • $p70^{s6k}$ lies on a $p21^{ras}$-independent signalling pathway and plays an important role in mitogenesis. Activation is associated with phosphorylation at multiple sites, four of which lie in an autoinhibitory region. The immunosuppressant rapamycin induces $p70^{s6k}$ inactivation through dephosphorylation of a second set of mitogen-induced sites. Here we identify these sites as $T_{229}$, $T_{389}$, and $S_{404}$. $T_{229}$ resides in the "T loop" of the catalytic domain, an essential phosphorylation site in other kinases. However, $p70^{s6k}$ inactivation by rapamycin most closely parallels $T_{389}$ dephosphorylation. Mutation of $T_{389}$ to alanine ablates kinase activity, whereas mutation to glutamic acid confers constitutive kinase activity and rapamycin resistance. indicating an essential role for phosphorylation at this site. $T_{389}$ resides in an unusual hydrophobic motif, not previously noted, between the catalytic and autoinhibitory domains. The importance of this site, and surrounding motif, is emphasized by its conservation in other kinases including homologues of $p70^{s6k}$ derived from such distantly related organisms as yeast and plant.

  • PDF

Some Tertiary Interactions in 5S rRNA from Xanthomonas celebensis (Xanthomonas celebensis 5S rRNA의 몇 가지 삼차상호작용)

  • Bongrae Cho;Yeonghoon Lee;Myung-Un Choi;Inwon Park
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.2
    • /
    • pp.237-243
    • /
    • 1993
  • The primary and secondary structure of the 5S rRNA isolated from Xanthomonas celebensis were determined by enzymatic and chemical degradation methods. It consists of 119 nucleotides and contains no modified nucleosides. As with the 5S rRNAs of X. maltophilia and X. citri, it contains an additional uridine residue on the 5'-terminus. Its secondary structure was almost identical to the models previously proposed by us for the 5S rRNA of two Xanthomonas species. Its secondary structure consists of five helices, five loops and two bulges. The tertiary interactions in the 5S rRNA molecule were analyzed by Fe(II)-EDTA treatment and hybridization method using deoxyhexamer. From the fact that some adenine residues in loop M, region $I_1-C$, loop $H_1$, and loop $H_2$ become susceptible to diethylpyrocarbonate when the 5S rRNA was hybridized with deoxyhexamer complementary to the sequence $U_{35}CCCAU_{40}$ and that some nucleotide residues in loop M, loop $H_1$ and region $D-I_2$ become resistant Fe(II)-EDTA cleavage in the presence of $Mg^{2+}$, it is presumed that loops $H_1$ and $H_2$ interact with loop M in some way. In the tertiary interaction, the regions $I_1-C$ and $D-I_2$ seem to act as hinges in folding the stems $B-I_1-C$ and $D-I_2-E.$ It was found that loop $H_1$ changes into a smaller loop of three bases by forming noncanonical A : C base-pairs ih acidic environment.

  • PDF