• Title/Summary/Keyword: P-loop

Search Result 521, Processing Time 0.04 seconds

Predictive Factors for Symptomatic Dislodgement of Percutaneous Transhepatic Biliary Drainage Catheter in Patients with Malignant Biliary Obstruction (악성 담관 폐쇄 환자에서 경피경간 담도 배액술의 유증상 이탈 발생의 예측 인자)

  • Hee Jeong Yu;Jung Gu Park;Gyoo Sik Jung;Kwang Il Seo;Hyun Joon Park;Jong Hyouk Yun
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1350-1360
    • /
    • 2023
  • Purpose To evaluate the factors that predict symptomatic dislodgement of a percutaneous transhepatic biliary drainage (PTBD) catheter in patients with malignant biliary obstruction. Materials and Methods This retrospective study included 572 patients with malignant biliary obstruction who underwent 733 PTBD catheter insertions between January 2010 and February 2015. The duration of catheter placement, approach site, location of the catheter tip, insertion angle, presence of a closed-loop pigtail, and tube diameter were evaluated. Results During the follow-up period, 224 PTBD catheter dislodgements (30.56%) were observed in 157 patients. Among them, 146 (19.92%) were symptomatic. The mean duration from catheter insertion until dislodgement was 32 days (range: 1-233 days). Male (odds ratio [OR]: 1.636, 95% confidence interval [CI]: 1.131-2.367, p = 0.009), right-sided approach (OR: 1.567, 95% CI: 1.080-2.274, p = 0.018), increased insertion angle (OR: 1.015, 95% CI: 1.005-1.026, p = 0.005), and incomplete closed-loop pigtail formation (OR: 1.672, 95% CI: 1.098-2.545, p = 0.016) were independent factors predictive of symptomatic dislodgement of a PTBD catheter. Conclusion Factors predictive of symptomatic catheter dislodgement included male sex, a right-sided approach, increased insertion angle, and incomplete closed-loop pigtail formation.

Coregulation of lux Genes and Riboflavin Genes in Bioluminescent Bacteria of Photobacterium phosphoreum

  • Sung, Nack-Do;Lee, ChanYong
    • Journal of Microbiology
    • /
    • v.42 no.3
    • /
    • pp.194-199
    • /
    • 2004
  • Investigation of the expression of the riboflavin (rib) genes, which are found immediately downstream of luxG in the lux operon in Photobacterium phosphoreum, provides more information relevant to the evolution of bioluminescence, as well as to the regulation of supply of flavin substrate for bacterial bioluminescence reactions. In order to answer the question of whether or not the transcriptions of lux and rib genes are integrated, a transcriptional termination assay was performed with P. phoxphoreum DNA, containing the possible stem-loop structures, located in the intergenic region of luxF and luxE ($\Omega$$\_$A/), of luxG and ribE ($\Omega$$\_$B/), and downstream of ribA ($\Omega$$\_$c/). The expression of the CAT (Chloram-phenicol Acetyl Transferase) reporter gene was remarkably decreased upon the insertion of the stem-loop structure ($\Omega$$\_$c/) into the strong lux promoter and the reporter gene. However, the insertion of the structure ($\Omega$$\_$B/) into the intergenic region of the lux and the rib genes caused no significant change in expression from the CAT gene. In addition, the single stranded DNA in the same region was protected by the P. phosphoreum mRNA from the Sl nuclease protection assay. These results suggest that lux genes and rib genes are part of the same operon in P. phosphoreum.

Comparison of Two Step LEEP and Cold Conisation For Cervical Intraepithelial Lesions to Decrease Positive Surgical Margins

  • Senol, Taylan;Polat, Mesut;Ozkaya, Enis;Karateke, Ates
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3317-3320
    • /
    • 2016
  • Purpose: To assess the success rates of two step loop electrosurgical excision procedure (LEEP) compared with conventional cold conization procedures for decreasing positive surgical margins. Materials and Methods: This study was conducted on 70 patients who underwent colposcopic evaluation in Zeynep Kamil Women and Children's Health Training and Research Hospital between 2013-2015 with indications of CIN 2/3 or persistent CIN 1 for more than 2 years. The study included age matched groups of patients with similar histopathololical lesions who underwent cold conization (n=40) or LEEP (N=30). Results: Comparison of tissue characteristics between the two groups revealed significantly higher deepest depth and lower volume of tissue removed by the two step LEEP. Ectocervical positivity rate was similar between groups (1/39 versus 0/29, P>0.05), while endocervical surgical margin positivity rate was significantly higher in the cold conization group (9/39 versus 0/29, P<0.05). Surgical margin positive cases were significantly older than the cases with negative margins (P<0.05). Conclusions: Two step LEEP made it easier to reach the squamocolumnar junction in the endocervical region with lower blood loss and applicability in office settings. Our study suggests to use two step approach in cases with high grade and glandular CIN.

The Structural and electrical Properties of $BaTiO_3$ Thin Films Deposited on Si/MgO Substrates (Si/MgO 기판에 증착된 BaTiO$_3$ 박막의 구조 및 전기적 특성)

  • 홍경진;김태성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.12
    • /
    • pp.1108-1114
    • /
    • 1998
  • $BaTiO_3$ thin films preferred c-axis orientation for the potential application of ferroelectric memory devices were deposited on silicon substrates(100) by RF sputtering and annealed at 800 and 900[$^{\circ}C$] in air. The BT(100)/BT(110) peak ratio of the sputtered sample was decreased with post-annealing in air. According to increasing with annealing temperature and time, the peak ratio of BT(100)/BT(110) was decreased and the surface density of thin film was high. Dielectric characteristics of $BaTiO_3$ thin film was measured as a function of annealing temperature and frequency. The dielectric constants were increased with annealing and decreased with frequency by space charge polarization and dipole polarization below 600[kHz]. The remanent polarization and coercive field in P-E hysteresis loop of $BaTiO_3$thin film were increased with the annealing temperature in air. The remanent polarization and coercive filed annealed at 800[$^{\circ}C$] for 1hr were 1.2[$\mu$C/$cm^2$] and 200[kV/cm]

  • PDF

Structural and Thermodynamic Characteristics of cHLH Peptide and cHLH/HDM2 Complex

  • Im, Haeri;Cho, Sunhee;Ham, Sihyun
    • Proceeding of EDISON Challenge
    • /
    • 2016.03a
    • /
    • pp.62-66
    • /
    • 2016
  • Tumor suppressor protein p53 loses its function upon binding with the HDM2 protein, and inhibiting the p53-HDM2 interaction is critical to suppress tumor cell growth. Recently, the cyclized helix-loop-helix peptide (cHLH) mimicking the ${\alpha}-helix$ part of the p53 protein has been designed and found to exhibit high binding affinity with HDM2. Here, we report the structural and thermodynamic characteristics of the bound complex of the cHLH peptide with the HDM2 protein. We performed molecular dynamics simulations to investigate the structural features of the cHLH peptide as well as its complex with the HDM2. The binding free energy calculation based on the integral equation theory was also executed to quantify the binding affinity for the cHLH/HDM2 complex and to understand the factors contributing to the binding affinity. We found a variety of factors for the helix stability of the cHLH peptide as well as in the complexation with the HDM2, which may provide an insight into the development of anti-cancer drug designs.

  • PDF

The P/PI Mode Switching Method of Closed Loop Gopinath Flux Observer for Sensorless Control of Induction Motors (유도전동기 센서리스 제어를 위한 폐루프 고피나스 자속관측기의 P/PI모드 전환 기법)

  • Kang, Myeong-Kyu;Choi, Jong-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.67-68
    • /
    • 2015
  • 본 논문은 폐루프 고피나스 자속관측기의 P/PI모드를 전환하여 전환점부근 저속에서 모터상수 변동에도 강인한 센서리스 벡터제어가 가능한 전환기법을 제안하였다.

  • PDF

Prevalence and extension of the anterior loop of the mental nerve in different populations and CBCT imaging settings: A systematic review and meta-analysis

  • Hadilou, Mahdi;Gholami, Leila;Ghojazadeh, Morteza;Emadi, Naghmeh
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.141-153
    • /
    • 2022
  • Purpose: This study aimed to identify the prevalence and extension of the anterior loop (AL) of the mental nerve in different populations and according to different cone-beam computed tomography (CBCT) imaging settings. Materials and Methods: Medline/PubMed, Embase, Scopus, Web of Science, and ProQuest were searched. The main inclusion criterion was ALs evaluated in CBCT images. The quality of studies was assessed with the Joanna Briggs Institute risk of bias checklist. Subgroup analyses were conducted for sex, side, continent, voxel size, field of view, and type of CBCT-reconstruction images with a random-effects model. Results: Sixty-three studies with 13,743 participants (27,075 hemimandibles) were included. An AL was found in 40.6% (95% CI: 32.8%-48.9%, P<0.05) of participants and 36.0% (95% CI: 27.5%-45.5%, P<0.05) of hemimandibles, in 34.9% (95% CI: 25.1%-46.2%, P<0.05) of males and 34.5% (95% CI: 23.5%-47.4%, P<0.05) of females. The average length of ALs was 2.39 mm (95% CI: 2.07-2.70 mm, P<0.05). Their extension was 2.13 mm (95% CI: 1.54-2.73 mm, P<0.05) in males and 1.85 mm (95% CI: 1.35-2.36 mm, P<0.05) in females. Significant differences were observed regarding the prevalence and length of ALs among continents and for its measured length on different CBCT-reconstruction images, but not between other subgroups. Conclusion: AL was a relatively common finding. The voxel size and fields of view of CBCT devices were adequate for assessing AL; however, a 2-mm safety margin from anatomical structures(such as the AL) could be recommended to be considered when using CBCT imaging.

TORSION IN THE COHOMOLOGY OF FINITE H-SPACES

  • Choi, Young-Gi
    • Journal of the Korean Mathematical Society
    • /
    • v.39 no.6
    • /
    • pp.963-973
    • /
    • 2002
  • We study torsion phenomena in the integral cohomology of finite if-spaces X through the Eilenberg-Moore spectral sequence converging to H*($\Omega$X; Z$_{p}$). We also investigate how the difference between the Z$_{p}$-filtration length f$_{p}$(X) and the Z$_{p}$-cup length c$_{p}$(X) on a simply connected finite H-space X is reflected in the Eilenberg-Moore spectral sequence converging to H*($\Omega$X;Z$_{p}$). Finally we get the following result: Let p be an odd prime and X an n-connected finite H-space with dim QH* (X;Z$_{p}$) $\leq$ m. Then H*(X;Z) is p-torsion free if (equation omitted).tion omitted).

A study on the effect of the magnitude of the gable bends on the tooth movement pattern during on-masse space closure in the maxillary dentition (상악전치 후방 견인시 견인 loop후방에 부여한 gable bend 양에 따른 치아이동 양상에 관한 연구)

  • Chun, Youn-Sic;Row, Joon;Jung, Sang-Hyuk;Kim, Hui-Jung
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.33-45
    • /
    • 2004
  • The purpose of this experimental study was to determine appropriate magnitude of the Gable bends to produce maximum retraction of the anterior teeth. The Calorific Machine was used to illustrate the tooth movement in three dimension. The experimental teeth except the first premolar were embedded in the artificial alveolar bone part. In a series of experiments, the extraction space was closed using arch wires with bull loops into which the gable bends of $10^{\circ},\;20^{\circ},\;30^{\circ}$ degrees were incorporated. The experiments were repeated three times for each degree of the gable bend. Before and after the space closure, radiographs were taken in the sagittal and occlusal directions using occlusal films. Analysis of variance and Scheffe post hoc test were used to determine significant differences among the three groups. The following results were obtained. 1. As magnitudes of the gable bends increased, more bodily anterior tooth movement was seen and the distance of retraction also increased. 2. As magnitudes of the gable bends increase, the amount of posterior tooth protraction decreased while intrusive and buccal movement increased. 3. The arch was coordinated by distal-in rotation of the canine and mesial-in rotation of the second premolar adjacent to the extraction space.

Posterior Cervical Fixation with Nitinol Shape Memory Loop in the Anterior-Posterior Combined Approach for the Patients with Three Column Injury of the Cervical Spine: Preliminary Report

  • Yu, Dong-Kun;Heo, Dong-Hwa;Cho, Sung-Min;Choi, Jong-Hun;Sheen, Seung-Hun;Cho, Yong-Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.5
    • /
    • pp.303-307
    • /
    • 2008
  • Objective: The authors reviewed clinical and radiological outcomes in patients with three column injury of the cervical spine who had undergone posterior cervical fixation using Nitinol shape memory alloy loop in the anterior-posterior combined approach. Materials: Nine patients were surgically treated with anterior cervical fusion using an iliac bone graft and dynamic plate-screw system, and the posterior cervical fixation using Nitinol shape memory loop ($Davydov^{TM}$) at the same time. A retrospective review was performed. Clinical outcomes were assessed using the Frankel grading method. We reviewed the radiological parameters such as bony fusion rate, height of iliac bone graft strut, graft subsidence, cervical lordotic angle, and instrument related complication. Results: Single-level fusion was performed in five patients, and two-level fusion in four. Solid bone fusion was presented in all cases after surgery. The mean height of graft strut was significantly decreased from $20.46{\pm}9.97mm$ at immediate postoperative state to $18.87{\pm}8.60mm$ at the final follow-up period (p<0.05). The mean cervical lordotic angle decreased from $13.83{\pm}11.84^{\circ}$ to $11.37{\pm}6.03^{\circ}$ at the immediate postoperative state but then, increased to $24.39{\pm}9.83^{\circ}$ at the final follow-up period (p<0.05). There were no instrument related complications. Conclusion: We suggest that the posterior cervical fixation using Nitinol shape memory alloy loop may be a simple and useful method, and be one of treatment options in anterior-posterior combined approach for the patients with the three column injury of the cervical spine.