• Title/Summary/Keyword: P-beam source

Search Result 75, Processing Time 0.039 seconds

Design, Fabrication and Micromachining Error Evaluation for a Surface-Micromachined Polysilicon Capacitice Accelerometer (표면미세가공기술을 이용한 수평감지방식의 정전용량형 다결정 실리콘 가속도계의 설계, 제작 및 가공 오차 영향 분석)

  • Kim, Jong-Pal;Han, Gi-Ho;Jo, Yeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.3
    • /
    • pp.529-536
    • /
    • 2001
  • We investigate a surface-micromachined capacitive accelerometer with the grid-type electrodes surrounded by a perforated proof-mass frame. An electromechanical analysis of the microaccelerometer has been performed to obtain analytical formulae for natural frequency and output sensitivity response estimation. A set of prototype devices has been designed and fabricated based on a 4-mask surface-micromachining process. The resonant frequency of 5.8$\pm$0.17kHz and the detection sensitivity of 0.28$\pm$0.03mV/g have been measured from the fabricated devices. The parasitic capacitance of the detection circuit with a charge amplifier has been measured as 3.34$\pm$1.16pF. From the uncertainty analysis, we find that the major uncertainty in the natural frequency of the accelerometer comes from the micromachining error in the beam width patterning process. The major source of the sensitivity uncertainty includes uncertainty of the parasitic capacitance, the inter-electrode gap and the resonant frequency, contributing to the overall sensitivity uncertainty in the portions of 75%, 14% and 11%, respectively.

A Comparative Study of Branching Ratio of 167Yb Radioactive Isotope from Gamma-ray Spectrum Produced by 169Tm(p,3n)167Yb Reaction with 100-MeV Proton Beam (100-MeV 양성자 빔을 이용하여 169Tm(p,3n)167Yb 반응에 의해 생성된 167Yb 방사성동위원소에서 방출되는 감마선 스펙트럼 비교 연구)

  • Sam-Yol, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.953-960
    • /
    • 2022
  • The measurement of branching ratio of 167Yb radioactive isotopes from gamma-ray spectrum of 169Tm(p,3n)167Yb reaction were performed by using a 100-MeV proton linear accelerator of the Korea Multi-purpose Accelerator Complex (KOMAC). The 167Yb isotope has a half-life of 17.5 minutes and decays to 169Tm. The gamma rays generated from the 167Yb isotope were measured using an HPGe detector gamma ray spectroscopy system. The energy calibration of the detector and the efficiency measurement of the detector were determined using a standard source. The gamma rays of known main energy (62.9, 106.2, 113.3, 143.5 and 176.3 keV) were measured. On the other hand, information about the intensity of the generated gamma rays is very inaccurate. Therefore, in this study, the decay strength of the main gamma rays was accurately measured. Overall, it was different from the previously known results, and in particular, it was found that the intensity of the main decay gamma ray, such as the 113.3 and 106.2 keV gamma ray, was overestimated, and it was found that the gamma ray, such as 62.9, 116.7 and 143.5 keV was underestimated. The present results are considered to be important information in the fields of nuclear fusion, astrophysics and nuclear physics in the future.

Highly Doped Nano-crystal Embedded Polymorphous Silicon Thin Film Deposited by Using Neutral Beam Assisted CVD at Room Temperature

  • Jang, Jin-Nyeong;Lee, Dong-Hyeok;So, Hyeon-Uk;Hong, Mun-Pyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.154-155
    • /
    • 2012
  • The promise of nano-crystalites (nc) as a technological material, for applications including display backplane, and solar cells, may ultimately depend on tailoring their behavior through doping and crystallinity. Impurities can strongly modify electronic and optical properties of bulk and nc semiconductors. Highly doped dopant also effect structural properties (both grain size, crystal fraction) of nc-Si thin film. As discussed in several literatures, P atoms or radicals have the tendency to reside on the surface of nc. The P-radical segregation on the nano-grain surfaces that called self-purification may reduce the possibility of new nucleation because of the five-coordination of P. In addition, the P doping levels of ${\sim}2{\times}10^{21}\;at/cm^3$ is the solubility limitation of P in Si; the solubility of nc thin film should be smaller. Therefore, the non-activated P tends to segregate on the grain boundaries and the surface of nc. These mechanisms could prevent new nucleation on the existing grain surface. Therefore, most researches shown that highly doped nc-thin film by using conventional PECVD deposition system tended to have low crystallinity, where the formation energy of nucleation should be higher than the nc surface in the intrinsic materials. If the deposition technology that can make highly doped and simultaneously highly crystallized nc at low temperature, it can lead processes of next generation flexible devices. Recently, we are developing a novel CVD technology with a neutral particle beam (NPB) source, named as neutral beam assisted CVD (NBaCVD), which controls the energy of incident neutral particles in the range of 1~300eV in order to enhance the atomic activation and crystalline of thin films at low temperatures. During the formation of the nc-/pm-Si thin films by the NBaCVD with various process conditions, NPB energy directly controlled by the reflector bias and effectively increased crystal fraction (~80%) by uniformly distributed nc grains with 3~10 nm size. In the case of phosphorous doped Si thin films, the doping efficiency also increased as increasing the reflector bias (i.e. increasing NPB energy). At 330V of reflector bias, activation energy of the doped nc-Si thin film reduced as low as 0.001 eV. This means dopants are fully occupied as substitutional site, even though the Si thin film has nano-sized grain structure. And activated dopant concentration is recorded as high as up to 1020 #/$cm^3$ at very low process temperature (< $80^{\circ}C$) process without any post annealing. Theoretical solubility for the higher dopant concentration in Si thin film for order of 1020 #/$cm^3$ can be done only high temperature process or post annealing over $650^{\circ}C$. In general, as decreasing the grain size, the dopant binding energy increases as ratio of 1 of diameter of grain and the dopant hardly be activated. The highly doped nc-Si thin film by low-temperature NBaCVD process had smaller average grain size under 10 nm (measured by GIWAXS, GISAXS and TEM analysis), but achieved very higher activation of phosphorous dopant; NB energy sufficiently transports its energy to doping and crystallization even though without supplying additional thermal energy. TEM image shows that incubation layer does not formed between nc-Si film and SiO2 under later and highly crystallized nc-Si film is constructed with uniformly distributed nano-grains in polymorphous tissues. The nucleation should be start at the first layer on the SiO2 later, but it hardly growth to be cone-shaped micro-size grains. The nc-grain evenly embedded pm-Si thin film can be formatted by competition of the nucleation and the crystal growing, which depend on the NPB energies. In the evaluation of the light soaking degradation of photoconductivity, while conventional intrinsic and n-type doped a-Si thin films appeared typical degradation of photoconductivity, all of the nc-Si thin films processed by the NBaCVD show only a few % of degradation of it. From FTIR and RAMAN spectra, the energetic hydrogen NB atoms passivate nano-grain boundaries during the NBaCVD process because of the high diffusivity and chemical potential of hydrogen atoms.

  • PDF

Study on 6 MV Photon beam Dosimetry by Asymmetric Collimator Variation of Linear Accelerator (6MV 선형가속기의 비대칭 조사야의 변화에 따른 선량분포)

  • Yoon, Joo-Ho;Lee, Chul-Soo;Yum, Ha-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.91-104
    • /
    • 2000
  • Recently linear accelerator in radiation therapy in asymmetric field has been easily used since the improvement and capability of asymmetrical field adjustment attached to the machine. It has been thought there have been some significant errors in dose calculation when asymmetrical radiation fields have been utilized in practice of radiation treatments if the fundamental data for dose calculation have been measured in symmetrical standard fields. This study investigated how much the measured data of dose distributions and their isodose curves are different between in asymmetrical and symmetrical standard fields, and how much there difference affect the error in dose calculation in conventional method measured in symmetrical standard field. The distributions of radiation dose were measured by photon diode detector in the water phantom (RFA-300P, Scanditronix, Sweden) as tissue equivalent material on utilization of 6 MV linear accelerator with source surface distance (SSD) 1000 mm. The photon diode detector has the velocity of 1 mm per second from water surface to 250 mm depth in the field size of $40mm{\times}40mm\;to\;250mm{\times}250mm\;symmetric\;field\;and\;40mm{\times}20mm\;to\;250mm{\times}125mm$ asymmetrical fields. The measurements of percent depth dose (PDD) and subsequent plotting of their isodose curves were performed from water surface to 250mm dmm from Y-center axis in $100mm{\times}50mm$ field in order to absence the variability of depth dose according to increasing field sizes and their affects to plotted isodose curves. The difference of PDD between symmetric and asymmetric field was maximum $4.1\%\;decrease\;in\;40mm{\times}20mm\;field,\;maximum\;6.6\%\;decrease\;in\;100mm{\times}50mm\;and\;maximum\;10.2\%\;decrease\;200mm{\times}100mm$, the larger decrease difference of PDD as the greater field size and as greater the depth, The difference of PDD between asymmetrical field and equivalent square field showed maximum $2.4\%\;decrease\;in\;60mm{\times}30mm\;field,\;maximum\;4.8\%\;decrease\;in\;150mm{\times}75mm\;and\;maximum\;6.1\%\;decrease\;in\;250mm{\times}125mm$, and the larger decreased differenced PDD as the greater field size and as greater the depth, these differences of PDD were out of $5\%$ of dose calculation as defined by international Commission on radiation unit and Measurements(ICRU). In the dose distribution of asymmetrical field (half beam) the plotted isodose curves were observed to have deviations by decreased PDD as greater as the blocking of the beam moved closer to the central axis, and as the asymmetrical field increased by moving the block 10 mm keeping away from the central axis, the PDD increased and plotted isodose curves were gradually more flattened, due to reduced amount of the primary beam and the fraction of low energy soft radiations by passing thougepth in asymmetrical field by moving independent jaw each 10 h beam flattening filter. As asymmetrical radiation field as half beam radiation technique is used, the radiation dosimetry calculated in utilizing the fundamental data which measured in standard symmetrical field should be converted on bases of nearly measured data in asymmetrical field, measured beam data flies of various asymmetrical field in various energy and be necessary in each institution.

  • PDF

940-nm 350-mW Transverse Single-mode Laser Diode with AlGaAs/InGaAs GRIN-SCH and Asymmetric Structure

  • Kwak, Jeonggeun;Park, Jongkeun;Park, Jeonghyun;Baek, Kijong;Choi, Ansik;Kim, Taekyung
    • Current Optics and Photonics
    • /
    • v.3 no.6
    • /
    • pp.583-589
    • /
    • 2019
  • We report experimental results on 940-nm 350-mW AlGaAs/InGaAs transverse single-mode laser diodes (LDs) adopting graded-index separate confinement heterostructures (GRIN-SCH) and p,n-clad asymmetric structures, with improved temperature and small-divergence beam characteristics under high-output-power operation, for a three-dimensional (3D) motion-recognition sensor. The GRIN-SCH design provides good carrier confinement and prevents current leakage by adding a grading layer between cladding and waveguide layers. The asymmetric design, which differs in refractive-index distribution of p-n cladding layers, reduces the divergence angle at high-power operation and widens the transverse mode distribution to decrease the power density around emission facets. At an optical power of 350 mW under continuous-wave (CW) operation, Gaussian narrow far-field patterns (FFP) are measured with the full width at half maximum vertical divergence angle to be 18 degrees. A threshold current (Ith) of 65 mA, slope efficiency (SE) of 0.98 mW/mA, and operating current (Iop) of 400 mA are obtained at room temperature. Also, we could achieve catastrophic optical damage (COD) of 850 mW and long-term reliability of 60℃ with a TO-56 package.

Impacts of Irradiation Sources on Quality Attributes of Low-salt Sausage during Refrigerated Storage

  • Song, Dong-Heon;Kim, Hyun-Wook;Hwang, Ko-Eun;Kim, Yong-Jae;Ham, Youn-Kyung;Choi, Yun-Sang;Shin, Dong-Jin;Kim, Tae-Kyung;Lee, Jae Hoon;Kim, Cheon-Jei;Paik, Hyun-Dong
    • Food Science of Animal Resources
    • /
    • v.37 no.5
    • /
    • pp.698-707
    • /
    • 2017
  • This study was performed to investigate the impacts of irradiation sources on quality attributes of low-salt sausage during refrigerated storage. Control sausage was prepared with 1.5% sodium chloride (NaCl), whereas low-salt sausage was formulated with 0.75% NaCl (a 50% reduction; L-control). Sausage samples were vacuum-packaged, and low-sausages were irradiated with gamma-ray, electron-beam and X-ray at 5 kGy, respectively. The samples were stored at $4^{\circ}C$ for 28 d to determine changes in quality attributes. The pH of low-salt sausages was unaffected by irradiation at 5 kGy (p>0.05). Higher redness values were found at irradiated low-salt sausages compared to control (p<0.05). The hardness, gumminess and chewiness of control sausage were higher than those of low-salt sausages (p<0.05). However, there were no significant differences in the textural parameters between low-salt sausage treatments. The overall sensory acceptability score of irradiated/low-salt sausages were lower than L-control due to decreased scores for cooked meat flavor but increased radiolytic off-flavor (p<0.05). The initial 2-thiobarbituric acid-reactive substances (TBARS) values of irradiated/low-salt sausages were higher than control and L-control (p<0.05). However, the TBARS values of irradiated treatments were significantly lower than control at the end of storage. Irradiation could effectively inhibit the microorganism growth (total aerobic bacteria, coliforms, Enterobacteriaceae, and Pseudomonas spp.) in low-salt sausages (p<0.05). Therefore, our findings show that irradiation could be to improve microbial safety of low-salt sausages, and suggest that further studies should be necessary to reducing radiolytic off-flavor of irradiated/low-salt sausages.

High-Dose-Rate Brachytherapy for Uterine Cervical Cancer : The Results of Different Fractionation Regimen (자궁경부암의 고선량률 근접치료 : 분할선량에 따른 결과 비교)

  • Yoon, Won-Sup;Kim, Tae-Hyun;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.228-236
    • /
    • 2002
  • Purpose : Although high-dose-rate (HDR) brachytherapy regimens have been practiced with a variety of modalities and various degrees of success, few studies on the subject have been conducted. The purpose of this study was to compare the results of local control and late complication rate according to different HDR brachytherapy fractionation regimens in uterine cervical cancer patients. Methods and Materials : From November 1992 to March 1998, 224 patients with uterine conical cancer were treated with external beam irradiation and HDR brachytherapy. In external pelvic radiation therapy, the radiation dose was $45\~54\;Gy$ (median dose 54 Gy) with daily fraction size 1.8 Gy, five times per week. In HDR brachytherapy, 122 patients (Group A) were treated with three times weekly with 3 Gy to line-A (isodose line of 2 cm radius from source) and 102 patients (Group B) underwent the HDR brachytherapy twice weekly with 4 or 4.5 Gy to line-A after external beam irradiation. Iridium-192 was used as the source of HDR brachytherapy. Late complication was assessed from grade 1 to 5 using the RTOG morbidity grading system. Results : The local control rate (LCR) at 5 years was $80\%$ in group A and $84\%$ in group B (p=0.4523). In the patients treated with radiation therapy alone, LCR at 5 years was $60.9\%$ in group A and $76.9\%$ in group B (p=0.2557). In post-operative radiation therapy patients, LCR at 5 years was $92.6\%$ In group A and $91.6\%$ in group B (p=0.8867). The incidence of late complication was $18\%$ (22 patients) and $29.4\%$ (30 patients), of bladder complication was $9.8\%$ (12 patients) and $14.7\%$ (15 patients), and of rectal complication was $9.8\%$ (12 patients) and $21.6\%$ (22 patients), in group A and B, respectively. Lower fraction sized HDR brachytherapy was associated with decrease in late complication (p=0.0405) (rectal complication, p=0.0147; bladder complication, p=0.115). The same result was observed in postoperative radiation therapy patients (p=0.0860) and radiation only treated patients (0=0.0370). Conclusion : For radiation only treated patients, a greater number of itemized studies on the proper fraction size of HDR brachytherapy, with consideration for stages and prognostic factors, are required. In postoperative radiation therapy, the fraction size of HDR brachytherapy did not have much effect on local control, yet the incidence of late complication increased with the elevation in fraction size. We suggest that HDR brachytherapy three times weekly with 3 Gy could be an alternative method of therapy.

A Study on Measurement of Gamma-ray Spectrum for the Natural Tungsten nuclear reaction by using KOMAC proton Linear Accelerator (KOMAC 양성자 선형가속기를 이용한 천연 텅스텐 핵반응에 대한 감마선 스펙트럼 측정에 대한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.133-138
    • /
    • 2018
  • The measurement of gamma-ray spectrum of $^{nat}W(p,xn)$ reaction with natural tungsten were performed by using a high energy proton generated from a 100-MeV proton linear accelerator of the Korea Multi-purpose Accelerator Complex (KOMAC). Gamma rays generated by various nuclides generated through the nuclide were measured using a gamma-ray spectroscopy system composed of HPGe detector. A gamma-ray standard source was used for energy calibration and efficiency measurement of the detector. Analysis of the gamma rays observed in the measured spectra showed that the radionuclides produced were $^{167}Re$, $^{178}Re$, $^{179}Re$, $^{180}Re$, $^{181}Re$, $^{182}Re$, $^{184}Re$, $^{172}Ta$, $^{174}Ta$, $^{178}Ta$, $^{182}Ta$, $^{184}Ta$, $^{175}W$, $^{176}W$, $^{177}W$ and $^{179}W$. Nuclides were generated. The results of this study will be applied to nuclear fusion, astrophysics, and nuclear medicine applications in the future.

Hybrid complementary circuits based on organic/inorganic flexible thin film transistors with PVP/Al2O3 gate dielectrics

  • Kim, D.I.;Seol, Y.G.;Lee, N.E.;Woo, C.H.;Ahn, C.H.;Ch, H.K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.479-479
    • /
    • 2011
  • Flexible inverters based on complementary thin-film transistor (CTFTs) are important because they have low power consumption and other advantages over single type TFT inverters. In addition, integrated CTFTs in flexible electronic circuits on low-cost, large area and mechanically flexible substrates have potentials in various applications such as radio-frequency identification tags (RFIDs), sensors, and backplanes for flexible displays. In this work, we introduce flexible complementary inverters using pentacene and amorphous indium gallium zinc oxide (IGZO) for the p-channel and n-channel, respectively. The CTFTs were fabricated on polyimide (PI) substrate. Firstly, a thin poly-4-vinyl phenol (PVP) layer was spin coated on PI substrate to make a smooth surface with rms surface roughness of 0.3 nm, which was required to grow high quality IGZO layers. Then, Ni gate electrode was deposited on the PVP layer by e-beam evaporator. 400-nm-thick PVP and 20-nm-thick ALD Al2O3 dielectric was deposited in sequence as a double gate dielectric layer for high flexibility and low leakage current. Then, IGZO and pentacene semiconductor layers were deposited by rf sputter and thermal evaporator, respectively, using shadow masks. Finally, Al and Au source/drain electrodes of 70 nm were respectively deposited on each semiconductor layer using shadow masks by thermal evaporator. Basic electrical characteristics of individual transistors and the whole CTFTs were measured by a semiconductor parameter analyzer (HP4145B, Agilent Technologies) at room temperature in the dark. Performance of those devices then was measured under static and dynamic mechanical deformation. Effects of cyclic bending were also examined. The voltage transfer characteristics (Vout- Vin) and voltage gain (-dVout/dVin) of flexible inverter circuit were analyzed and the effects of mechanical bending will be discussed in detail.

  • PDF

Assessment of endodontically treated teeth by using different radiographic methods: an ex vivo comparison between CBCT and other radiographic techniques

  • Demiralp, Kemal Ozgur;Kamburoglu, Kivanc;Gungor, Kahraman;Yuksel, Selcen;Demiralp, Gokcen;Ucok, Ozlem
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.129-137
    • /
    • 2012
  • Purpose: To compare different radiographic methods for assessing endodontically treated teeth. Materials and Methods: Root canal treatments were applied in 120 extracted mandibular teeth, which were divided into four groups: (1) ideal root canal treatment (60 teeth), (2) insufficient lateral condensation (20 teeth), (3) root canals filled short of the apex (20 teeth), (4) overfilled root canal treatment (20 teeth). The teeth were imaged using intraoral film, panoramic film, digital intraoral systems (CCD and PSP), CCD obtained with portable X-ray source, digital panoramic, and CBCT images obtained at 0.3 $mm^3$ and 0.2 $mm^3$ voxel size. Images were evaluated separately by three observers, twice. Kappa coefficients were calculated. The percentage of correct readings obtained from each modality was calculated and compared using a t-test (p<0.05). Results: The intra-observer kappa for each observer ranged between 0.327 and 0.849. The inter-observer kappa for each observer for both readings ranged between 0.312 and 0.749. For the ideal root canal treatment group, CBCT with 0.2 $mm^3$ voxel images revealed the best results. For insufficient lateral condensation, the best readings were found with periapical film followed by CCD and PSP. The assessment of teeth with root canals filled short of the apex showed the highest percentage of correct readings by CBCT and CCD. For the overfilled canal treatment group, PSP images and conventional periapical film radiographs had the best scores. Conclusion: CBCT was found to be successful in the assessment of teeth with ideal root canal treatment and teeth with canals filled short of the apex.