• Title/Summary/Keyword: P-V value

Search Result 1,083, Processing Time 0.023 seconds

A Study on the Stability Control Method of Soft and Polluted Silt Soils (연약한 실트지반과 오염된 실트지반의 안정관리 방법에 관한 연구)

  • Ahn, Jong-Pil;Park, Sang-Bum
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.6
    • /
    • pp.5-16
    • /
    • 2008
  • This study investigated the existing theoretical backgrounds in order to examine the stability control method of lateral flow caused by the Plasticity of soils when unsymmetrical surcharge works on polluted soils and then compared and analyzed the results measured through model tests. Ultimate bearing power of ML and $ML_{p1}$ and $ML_{p2}$ obtained at surcharge(q)-settlement$(S_v)$ curve showed similar trends to ultimate bearing power obtained from control chart of deflection $(S_v-Y_m)$ by Tominaga.Hashimoto, that of $S_v-(Y_m/S_v)$ by Matsuo.Kawamura and that of $(q/Y_m)-q$ by Shibata.Sekiguchi and so it is considered that it has no problem in actual applicability. ${S_v-(Y_m/S_v)}$ of control chart of $ML_{p1}$ by Matsuo.Kawamura showed smaller value than ultimate bearing capacity value from surcharge-settlement curve $(q-S_v)$. Expression of ML of fracture baseline at stability control charge by Matsuo Kawamura is ${S_v=3.21exp}\{-0.48(Y_m/S_v)\}$ and expression of $ML_{p1}$ is ${S_v=3.26exp}\{-0.96(Y_m/S_v)\}$ and expression of $ML_{p2}$ is ${S_v=6.33exp}\{-0.45(Y_m/S_v)\}$.

Physiological Responses to Maximal Exercise Loading in Spinal Cord Injured Paraplegia (척수손상으로 인한 하반신마비 환자의 최대운동부하시 생리학적 반응)

  • Yu, Byong-Kyu;Chung, Nak-Su
    • Physical Therapy Korea
    • /
    • v.6 no.2
    • /
    • pp.56-66
    • /
    • 1999
  • The purpose of this study focused how to show physiological responses comparing exercise group and non exercise group for progressive maximal wheelchair ergometer exercise loading in complete paraplegia. It also examined the various factors which would be influenced physiological responses. Sixteen subjects have been investigated in this study, and the subjects are divided into two groups as follows: 1) exercise group (7 subjects) 2) non exercise group (9 subjects). Each test was terminated by physical exhaustion and/or an inability to maintain a flywheel velocity. The results were as follows: 1) No difference was noted in pulmonary function test between two groups. 2) $\dot{v}$ Emax value during maximal exercise was significantly different between the groups (p<0.05). The mean $\dot{v}$ Emax of exercise group was $69.67{\ell}/min$, non exercise group was $41.47{\ell}/min$. 3) $\dot{v}$ $O_2max$(${\ell}/min$) value during maximal exercise was significantly different between the groups (p<0.05). The mean $\dot{v}$ $O_2max$(${\ell}/min$) of exercise group was $1.72{\ell}/min$, non exercise group was $1.15{\ell}/min$. 4) $\dot{v}$ $O_2$ max(ml/kg/min) value during maximal exercise was significantly different between the groups (p<0.05). The mean $\dot{v}$ $O_2max$($ml/kg{\cdot}min$) of exercise group was $25.99ml/kg{\cdot}min$, non exercise group was $18.61{\ell}/min$. 5) Maximal heart rate(HRmax) value during maximal exercise was significantly different between the groups (p<0.05). The mean HRmax of exercise group was 180.43 beats/min, non exercise group was 175.00 beats/min. 6) $\dot{v}\;E/\dot{v}\;O_2$ value during maximal exercise was not significantly different between the groups (p>0.05). The mean $\dot{v}\;E/\dot{v}\;O_2$ of exercise group was $36.36{\ell}/{\ell}\;O_2$, non exercise group was $45.46{\ell}/{\ell}\;O_2$. Considering the results which explore the exercise group with paraplegia has shown the maximal aerobic power compared with non exercise group, regular and consistent physical training is highly assumed as a main factor to improve cardiopulmonary fitness.

  • PDF

Quality Characteristics and Vitamin K2 (MK-7) Productivity of Cheonggukjang fermented by Bacillus subtilis SRCM100757 with Different Inoculum Concentrations and Fermentation Time (Bacillus subtilis SRCM100757를 이용하여 접종농도와 발효기간을 달리하여 제조한 청국장의 품질 특성 및 Vitamin K2(MK-7) 생성능 평가)

  • Jeong, Min-Hong;Bang, Seon-Ok;Kim, Kum-Suk
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.27 no.3
    • /
    • pp.341-347
    • /
    • 2017
  • This study was carried out to investigate the characteristics and Vitamin $K_2$ (MK-7) productivity of Cheonggukjang fermented by Bacillus subtilis SRCM100757 depending on the inoculum concentration 0.5% (v/w), 1% (v/w) and 2% (v/w). The lowest moisture content and water activity were $53.7{\pm}0.6%$ and $8.39{\pm}0.09$ after fermentation for 72 hours at 2% (v/w). pH slowly became alkalized during fermentation, but there was no significant difference. Amino nitrogen content increased with time and the highest content was $580.8{\pm}1.9mg%$ after fermentation for 72 hours at 2% (v/w). Lightness (L value) and yellowness (b value) decreased with time, whereas redness (a value) hardly changed. MK-7 contents increased with time at each inoculum concentration. The highest content was $20.47{\pm}1.53$ after fermeatation for 72 hours at 2%(v/w) and there were no significant differences between 1%(v/w) and 2%(v/w) inoculum concentrations.

pH Sensitive Graphene Field-Effect Transistor(FET) (pH에 민감한 그래핀 전계효과 트랜지스터(FET))

  • Park, Woo Hwan;Song, Kwang Soup
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.2
    • /
    • pp.117-122
    • /
    • 2016
  • Recently, the detection of pH with real-time and in vivo has been focal pointed in the environmental or medical fields. In this work, we developed the pH sensor using graphene sheet. Graphene has high biocompatibility. We fabricated flexible solution-gated field-effect transistors (SGFETs) on graphene sheet transferred on the polyethylene terephthalate (PET) substrate to detect pH in electrolyte solution. The gate length was $500{\mu}m$ and the gate width was 8 mm. We evaluated the current-voltage (I-V) transfer characteristics of graphene SGFETs in pH solution. The drain-source current ($I_{DS}$) and the gate-source voltage ($V_{GS}$) curves of graphene SGFETs were depended on pH value. The Dirac point of graphene SGFETs linearly shifted to the positive direction about 19.32 mV/pH depending on the pH value in electrolyte solution.

A Study on the 80V BICMOS Device Fabrication Technology (80V BICMOS 소자의 공정개발에 관한 연구)

  • Park, Chi-Sun;Cha, Seung-Ik;Choi, Yearn-Ik;Jung, Won-Young;Park, Yong
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.10
    • /
    • pp.821-829
    • /
    • 1991
  • In this paper, a BICMOS technology that has CMOS devices for digital application and bipolar devices for high voltage (80V) analog applications is presented. Basic concept to design BICMOS device is simple process technology without making too many performance trade-offs. The base line process is poly gate p-well CMOS process and three additional masking steps are added to improve bipolar characteristics. The key ingredients of bipolar integration are n+ buried layer process, up/down isolation process and p-well base process. The bipolar base region is formed simultaneously with the region of CMOS p-well area to reduce mask and heat cycle steps. As a result, hFE value of NPN bipolar transistor is 100-150(Ic=1mA). Collector resistance value is 138 ohm in case of bent type collector structure. Breakdown voltage of BVebo, BVcbo and BVceo are 21V, 115V and78V respectively. Threshold voltage is ${\pm}$1.0V for NMOS and PMOS transistor. Breakdown voltage of NMOS and PMOS transistor is obtained 22V and 19V respectively. 41 stage CMOS ring oscillator has 0.8ns delay time.

  • PDF

ANALYSIS OF THE LiF:Mg,Cu,Si TL AND THE LiF:Mg,Cu,P TL GLOW CURVES BY USING GENERAL APPROXIMATION PLUS MODEL

  • Chang, In-Su;Lee, Jung-Il;Kim, Jang-Lyul;Oh, Mi-Ae;Chung, Ki-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.155-164
    • /
    • 2009
  • In this paper, we used computerized glow curve deconvolution (CGCD) software with several models for the simulation of a TL glow curve which was used for analysis. By using the general approximation plus model, parameters values of the glow curve were analyzed and compared with the other models parameters (general approximation, mixed order kinetics, general order kinetics). The LiF:Mg,Cu,Si and the LiF:Mg,Cu,P material were used for the glow curve analysis. And we based on figure of merits (FOM) which was the goodness of the fitting that was monitored through the value between analysis model and TLD materials. The ideal value of FOM is 0 which represents a perfect fit. The main glow peak makes the most effect of radiation dose assessment of TLD materials. The main peak of the LiF:Mg,Cu,Si materials has a intensity rate 80.76% of the whole TL glow intensity, and that of LiF:Mg,Cu,P materials has a intensity rate 68.07% of the whole TL glow intensity. The activation energy of LiF:Mg,Cu,Si was analyzed as 2.39 eV by result of the general approximation plus(GAP) model. In the case of mixed order kinetics (MOK), the activation energy was analyzed as 2.29 eV. The activation energy was analyzed as 2.38 eV by the general order kinetics (GOK) model. In the case of LiF:Mg,Cu,P TLD, the activation energy was analyzed as 2.39 eV by result of the GAP model. In the case of MOK, the activation energy was analyzed as 2.55 eV. The activation energy was analyzed as 2.51 eV by the GOK model. The R value means different ratio of retrapping-recombination. The R value of LiF:Mg,Cu,Si TLD main peak analyzed as $1.12\times10^{-6}$ and $\alpha$ value analyzed as $1.0\times10^{-3}$. The R of LiF:Mg,Cu,P TLD analyzed as $7.91\times10^{-4}$, the $\alpha$ value means different ratio of initial thermally trapped electron density-initial trapped electron density (include thermally disconnected trap electrons density). The $\alpha$ value was analyzed as $9.17\times10^{-1}$ which was the difference from LiF:Mg,Cu,Si TLD. The deep trap electron density of LiF:Mg,Cu,Si was higher than the deep trap electron density of LiF:Mg,Cu,P.

Remineralization Effects on the Demineralized Enamel of Primary Teeth by Fluoride Varnish (불소바니쉬에 의한 탈회 유전치 법랑질의 재광화 효과)

  • Cho, Seongeun;Kim, Jongbin;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.1
    • /
    • pp.44-50
    • /
    • 2016
  • The purpose of this study was to compare and evaluate the remineralization effect of three types of fluoride varnishes on demineralized enamel of primary teeth. 40 primary teeth were decalcified by soaking them in artificial acidic solution and stored at $37^{\circ}C$ for 7 days. Then 3 varnishes - Cavity shield$^{TM}$, V varnish$^{TM}$ and MI varnish$^{TM}$ were applied respectively one time a week, for 3 weeks on the demineralized enamel surface. For the first week, MI varnish$^{TM}$ showed the highest microhardness value, V varnish$^{TM}$ was in second position, and Cavity shield$^{TM}$ showed the lowest microhardness value. However, there was no significant difference among the three groups(p > 0.05). For the second week, V varnish$^{TM}$ showed the highest microhardness value, and MI varnish$^{TM}$ came next in second position noting no significant difference (p > 0.05). Cavity shield$^{TM}$ was significantly lower than the other groups (p < 0.05). For the third week, V varnish$^{TM}$ showed the highest microhardness value, noting a significant difference from the other groups (p < 0.05). MI varnish$^{TM}$ came next, while Cavity shield$^{TM}$ showed the lowest microhardness value. However, there was no significant difference between MI varnish$^{TM}$ and Cavity shield$^{TM}$ (p > 0.05). The increase in the microhardness of groups V varnish$^{TM}$ and MI varnish$^{TM}$ were higher than that of group Cavity shield$^{TM}$ (p < 0.05), while no significant difference was noted between groups V varnish$^{TM}$ and MI varnish$^{TM}$ (p > 0.05).

Changes of Cerebral Metabolism and the Related Factors during Cardiac Surgery

  • Park, Seok-Cheol
    • Biomedical Science Letters
    • /
    • v.8 no.3
    • /
    • pp.143-154
    • /
    • 2002
  • The effect of cardiopulmonary bypass (CPB) on cerebral physiology during heart surgery remains incompletely understood. This study was carried out to investigate changes of cerebral metabolism and the association between the changes and clinical factors during heart surgery. Seventy adult patients (n=70) scheduled for elective cardiac surgery were participated in the present study. Middle cerebral artery blood flow velocity (V$_{MCA}$), cerebral arteriovenous oxygen content difference (C(a-v)O$_2$), cerebral oxygen extraction (COE), and modified cerebral metabolic rate for oxygen (MCMRO$_2$) were measured during six phases of the operation; Pre-CPB, CPB-10 min, Rewarm-1 (nasopharyngeal temperature 34$^{\circ}C$), Rewarm-2 (nasopharyngeal temperature 37$^{\circ}C$), CPB-off, and Post-OP (at skin closure after CPB-off). Each relationship of age, arterial blood gas parameters, or other variables to V$_{MCA}2$, C(a-v)O$_2$, COE, or MCMRO$_2$ was evaluated. V$_{MCA}$ increased (P<0.0001) whereas C(a-v)O$_2$ decreased (P<0.01) throughout the five phases of the operation compared to Pre-CPB value (control). COE diminished at CPB-10, Rewarm-1, and CPB-off (P<0.05) while MCMRO$_2$ reduced at CPB-10 and Rewarm-1 (P<0.05) compared to Pre-CPB value. Positive correlation was found between age and cerebral metabolic parameters (V$_{MCA}$, C(a-v)O$_2$, COE, or MCMRO$_2$) during CPB (range r=0.24 to 0.38, p<0.05). Four cerebral metabolic parameters had partially negative or positive correlation with arterial blood gas parameters and other variables (arterial blood pH, $O_2$ tension, $O_2$ content, $CO_2$ tension, blood pressure, blood flow, temperature, or hematocrit) during the operation. In conclusion, CPB led to marked alterations of cerebral metabolism and age, pH, and $CO_2$ tension profoundly influenced the changes during cardiac surgery.

  • PDF

A Comparison Study Between Image Analysis and Conventional Methods in the Evaluation of Asian Skin Color (아시아 피부에서 기존 미백 평가방법과 이미지 분석방법의 비교연구 (비타민 C 제형의 이온토포레시스 연구))

  • Park, Hye Kyong;Kim, Nam Soo;Moon, Tae Kee;Kim, Bora;Jung, Ho Young
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.2
    • /
    • pp.97-103
    • /
    • 2015
  • Until recently, the three conventional evaluation methods, which are instrumental (Chromameter$^{(R)}$ CR-400 and Mexameter$^{(R)}$ M18) and visual assessments have been used frequently for skin color evaluation. However, we took notice the potential of image analysis as a new tool to evaluate color change of skin. To reveal the reliability of the image analysis for the evaluation of whitening agents, 34 healthy female volunteers with hyperpigmentation were recruited, and the selected volunteers applied the whitening products containing Vitamin C twice a day in the morning and evening and received iontophoresis treatments once a week for 8 weeks. The changes in hyperpigmentation evaluated by Chromameter$^{(R)}$, Mexameter$^{(R)}$ and visual assessment were compared with the results from the image analysis. As with $L^*$ value trends of the analysis using Chromameter$^{(R)}$, the V value from the image analysis increased after applying the test products compared with baseline values. Furthermore, V value showed a positive correlation with $L^*$ value (r = 0.494, p < 0.01) and negative correlation with MI (r = - 0.683, p < 0.01) and VG (r = - 0.549, p < 0.01). Therefore, image analysis may be considered as an effective method to complement the limitations of visual assessment for whitening efficacy in Asians.

Study on the Evaluation of D.P. and Handle for Vapor Phase Finished Fabrics (V.P.가공 직물의 D.P.성과 Handle 평가에 관한 연구)

  • 최근영;백천의
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.5
    • /
    • pp.792-800
    • /
    • 1996
  • The shape retention finishing provides a fabric for easiness of no-ironing after laundering. In spite of the obvious importance of the new finishing treatment, few systematic studies have been performed on the handle of the fabrics finished by the durable press process. The purpose of this research is to investigate the relationships among the mechanical properties, durable press conditions, primary hand values and the total hand value of the fabrics finished by shape retention process. In this experiment, durable press grade of unfinished fabrics decreased below 2.5, but those of finished fabrics maintained above 4, but the mechanical properties of finished fabrics did not change significantly after laundering. In finished fabrics, D.P. value were correlated with mechanical properties, but had little effects with H.V. and T.H.V. Since the evaluation of the effect of durable press process was done with the naked eyes and standard sample, we could not know exactly change o( mechanical properties, but trace the change of mechanical properties which gave influences on the durable press effects by using KES-FB System.

  • PDF