• 제목/요약/키워드: P-T limit

검색결과 247건 처리시간 0.025초

SPECTRA OF THE IMAGES UNDER THE FAITHFUL $^*$-REPRESENTATION OF L(H) ON K

  • Cha, Hyung-Koo
    • 대한수학회보
    • /
    • 제22권1호
    • /
    • pp.23-29
    • /
    • 1985
  • Let H be an arbitrary complex Hilbert space. We constructed an extension K of H by means of weakly convergent sequences in H and the Banach limit. Let .phi. be the faithful *-representation of L(H) on K. In this note, we investigated the relations between spectra of T in L(H) and .phi.(T) in L(K) and we obtained the following results: 1) If T is a compact operator on H, then .phi.(T) is also a compact operator on K (Proposition 6), 2) .sigma.$_{l}$ (.phi.(T)).contnd..sigma.$_{l}$ (T) for any operator T.mem.L(H) (Corollary 10), 3) For every operator T.mem.L(H), .sigma.$_{ap}$ (.phi.(T))=.sigma.$_{ap}$ (T))=.sigma.$_{ap}$ (T)=.sigma.$_{p}$(.phi.(T)) (Lemma 12, 13) and .sigma.$_{c}$(.phi.(T))=.sigma.(Theorem 15).15).

  • PDF

Detection of Pectobacterium chrysanthemi Using Specific PCR Primers Designed from the 16S-23S rRNA Intergenic Spacer Region

  • Kwon, Soon-Wo;Myung, In-Sik;Go, Seung-Joo
    • The Plant Pathology Journal
    • /
    • 제16권5호
    • /
    • pp.252-256
    • /
    • 2000
  • The 16S-23S rRNA intergenic spacer regions (ISRs) were sequenced and analyzed to design specific primer for identification of Pectobacterium chrysanthemi. Two types ISRs, large and small ISRs, were identified from three strains (ATCC 11663, KACC 10163 and KACC 10165) of P. chrysanthemi and Pectobacterium carotovorum subsp. carotovorum ATCC 15713.Large ISRs contained transfer RNA-Ile(tRNA$^{Ile}$)and tRNA$^{Ala}$, and small ISRs contained tRNA$^{Glu}$. Size of the small ISRs of P. chrysanthemi ranged on 354-356 bp, while it was 451 bp in small ISR of P. carotovorum subsp. carotovorum ATCC 15713. From hypervariable region of small ISRs, species-specific primer for P. chrysanthemi with 20 bp length (CHPG) was designed from hypervariable region of small ISRs, which was used as forward promer to detect P. chrysanthemi strains with R23-1R produced PCR product of about 260bp size (CHSF) only from P. chrysanthemi strains, not from other Pectobacterium spp. and Erwinia spp. Direct PCR from bacterial cell without extracting DNA successfully amplified a specific fragment, CHSF, from P. chrysanthemi ATCC 11663. The limit of PCR detection was 1${\pm}10^2$ cfu/ml.

  • PDF

자동화학 분석기 Toshiba 120 FR의 평가 (Evaluation of Autochemical Analyzer Toshiba 120 FR)

  • 박점기
    • 대한임상검사과학회지
    • /
    • 제36권2호
    • /
    • pp.98-109
    • /
    • 2004
  • The lower limit of detection, precision, setting method of target value, reportable range determination, recovery, linearity, and comparison study with another equipment was evaluated for the Toshiba-120FR chemistry autoanalyzer which was newly introduced at the Daejeon Veteran Hospital in Dec. 2003. Nineteen kinds of test for AST, ALT, ALP, LDH, GGT, TP, ALB, GLU, T-cho, T-bil, TG, UA, CAL, IP, AMY, HDL-C, LDL-C, Cre and BUN were performed to evaluate the lower limit of detection, precision, setting method of target value, reportable range determination, recovery, linearity, and comparison study with other equipment according to the NCCLS guidelines(EP5-A, EP6-P, EP9-A). The Toshiba-120FR autochemical analyzer showed good precision for all tested items. The data concerning the lower limit of detection, precision(total CV 0.47%~3.65%), setting method of target value, reportable range determination, recovery(93%~111%), linearity($R^2=0.997{\sim}0.999$), and comparison study(r=0.977~0.999) with other equipment was acceptable for all tested items. The results of evaluation for the Toshiba-120FR autochemical analyzer showed that this equipment could be used as an alternative to other equipment.

  • PDF

영양염류 제거를 위한 생물막 공정의 적용에 관한 연구 (A Study on apply of submerged biofilter for nutrient removal)

  • 안승섭
    • 한국환경과학회지
    • /
    • 제9권5호
    • /
    • pp.415-422
    • /
    • 2000
  • In this study the removal possibility of nutrients of T-P, NH3-N, NO3-N and T-N is examined through a positive experimental study using submerged biofilter of media packing channel method. From the analysis of nutrients removal efficiency for each run of the collected sample following results are obtained. Firstly the result of N/P surveying for inflow shows serious value that excess the limit value of 20 as the values are in the range of 12.0~42.7 and the average is 25.73. Secondly the highest concentration of the incoming NH3-N reaches double of the standard since the concentrations of NH3-N and NO3-N for inflow shows 0.06mg/$\ell$ and 2.5~3.8mg/$\ell$ respectively and the average removal rate which passed the submerged biofilter adopted in this study is a satisfactory level. Next the average removal rate of T-P of 51.5% shows the possiblity of entrophication removal since the removal rate of T-P of 66.8~68.8% in relative low temperature period of RUN 1~2 appeared higher than in RUN 3~6 and T-N shows relatively poor result with the average removal rate of 34.1% And it is known that the bigger BOD/P and BOD/N are the more removal rate increases from the examination result of the relation between BOD/P and BOD/N and the treatment water T-P and T-N to decide the relation with the concentration of organic matters and though that the appropriate proportion is necessary for effective removal of nitrogen and phsophorus.

  • PDF

접촉산화법에 의한 소각로 배출폐액의 처리에 관한 연구 (A Study on the Treatment of Incinerator Wastewater with Biofilm Reactor)

  • 신대윤;서동우
    • 한국환경보건학회지
    • /
    • 제26권3호
    • /
    • pp.92-97
    • /
    • 2000
  • The treatment of the washout from small scale incinerator was performed physically, chemically and biologically. The results are as follows. 1. SS, FS removal efficiency of washout wastewater from incinerator was 67.4%, 37.4%, while SS, FS of sewage wastewater was removed 63.2% 35.4% respectively. 2. The optimal conditions for chemical coagulation turned out to be pH 7.5, alum(Al2O3 10%) 30ml/ι and polyelectrolyte(A-601P 0.1%) 4ml/ι. SS 86%, FS 89.5%, BOD 42.5% and CODMn, 63.5% was removed and the removal efficiency of some metals are shown as Pb 93.5%, Zn 86.5% and Fe 80.6%. The concentration of the effluent was SS 9mg/ι, BOD 98.4mg/ι, and CODMn 138.4mg/ι. 3. The removal efficiency in treating washout wastewater of incinerator through HBC-briquet media was getting higher with increasing HRT, and mixed wastewater with 1:1, 1:2 ratio could be met up to the standard limit with higher HRT than 12hr. Under the condition of 1:2 mix ratio and HRT 24 hr, removal efficiency of SS, BOD, CODMn, T-N and T-P was 92.1%, 90%, 87%, 48.2% and 48%, respectively, and the concentration of treated wastewater was SS 2.9 mg/ι, BOD 10.3mg/ι, CODMn 14.1mg/ι, T-N 11.6 mg/ι and T-P 1.3 mg/ι, respectively.

  • PDF

전북도내 농업용저수지의 수질조사 연구 (Studies on Water Quality of Agricultural Reservoirs in Chonbuk Province)

  • 최진규;손재권;구자웅
    • 한국농공학회지
    • /
    • 제38권2호
    • /
    • pp.65-74
    • /
    • 1996
  • This study was carried out to investigate the water quality of agricutural reservoirs in Chonbuk Province. The water quality of 189 agricultural reservoirs was surveyed in the environmental standard phase of pH, EC, DO, BOD, COD, T-N, T-P, etc. The results obtained in this study are summarized as follows ; 1. The levels of mean reservoir storage were very low as 26.9% in January and February, 29.4% in June, 16.0% in August, and 25.4% as a whole. 2. The water qualities of agricultural reservoirs were shown to be in the average of 6.8in pH, 0.2l0mmhos/cm in EC, 49.Oppm in turbidity, 28.5mg/$\ell$in SS, 3.79mg/$\ell$ in DO, 9. 9mg/$\ell$ in COD, 5.Smg/$\ell$ in BOD, 0.179mg/ $\ell$ in T-P, 4.O9mg/$\ell$ in T-N, 0.416meq/$\ell$ in Na, 0.154meq/$\ell$ in K, 0.320meq/$\ell$ in Ca, 0.166meq/$\ell$ in Mg, respectively. 3. In the analyzed results, the proper counterplan is desirable to be considered because the levels of water quality in most items except DO were comparatively higher than the limit points of agricultural water quality standard.

  • PDF

원자로용기 건전성평가를 위한 RVIES 시스템의 개발 (Development of a RVIES Syetem for Reactor Vessel Integrity Evaluation)

  • 이택진;최재붕;김영진;박윤원;정명조
    • 대한기계학회논문집A
    • /
    • 제24권8호
    • /
    • pp.2083-2090
    • /
    • 2000
  • In order to manage nuclear power plants safely and cost effectively, it is necessary to develop integrity evaluation methodologies for the main components. Recently, the integrity evaluation techniques were broadly studied regarding the license renewal of nuclear power plants which were approaching their design lives. Since the integrity evaluation process requires special knowledges and complicated calculation procedures, it has been allowed only to experts in the specified area. In this paper, an integrity evaluation system for reactor pressure vessel was developed. RVIES(Reactor Vessel Integrity Evaluation System) provides four specific integrity evaluation procedures covering PTS(Pressurized Thermal Shock) analysis, P-T(Pressure-Temperature) limit curve generation, USE(Upper Shelf Energy) analysis and Fatigue analysis. Each module was verified by comparing with published results.

Thermal stress intensity factor solutions for reactor pressure vessel nozzles

  • Jeong, Si-Hwa;Chung, Kyung-Seok;Ma, Wan-Jun;Yang, Jun-Seog;Choi, Jae-Boong;Kim, Moon Ki
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2188-2197
    • /
    • 2022
  • To ensure the safety margin of a reactor pressure vessel (RPV) under normal operating conditions, it is regulated through the pressure-temperature (P-T) limit curve. The stress intensity factor (SIF) obtained by the internal pressure and thermal load should be obtained through crack analysis of the nozzle corner crack in advance to generate the P-T limit curve for the nozzle. In the ASME code Section XI, Appendix G, the SIF via the internal pressure for the nozzle corner crack is expressed as a function of the cooling or heating rate, and the wall thickness, however, the SIF via the thermal load is presented as a polynomial format based on the stress linearization analysis results. Inevitably, the SIF can only be obtained through finite element (FE) analysis. In this paper, simple prediction equations of the SIF via the thermal load under, cool-down and heat-up conditions are presented. For the Korean standard nuclear power plant, three geometric variables were set and 72 cases of RPV models were made, and then the heat transfer analysis and thermal stress analysis were performed sequentially. Based on the FE results, simple engineering solutions predicting the value of thermal SIF under cool-down and heat-up conditions are suggested.

MINERAL STATUS OF GRAZING PHILIPPINE GOATS I. THE NUTRITION OF CALCIUM, MAGNESIUM AND PHOSPHORUS OF GOATS IN LUZON ISLAND

  • Fujihara, T.;Matsui, T.;Hayashi, S.;Robles, A.Y.;Serra, A.B.;Cruz, L.C.;Shimizu, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제5권2호
    • /
    • pp.383-388
    • /
    • 1992
  • Nutritional status of macro minerals (Ca, Mg and P) in goats grazed on the native pasture was investigated for 2 years in Luzon Island, Republic of the Philippines. Three regions in Luzon Island (Los Banos; Southern area, Munoz, Nueva Ecija; Central area and Baguio; Northern area) were objected to collect the samples of forages and blood of goats on the pasture. The average values in Ca, Mg and P contents of all the forage samples were 0.29-1.32, 0.13-0.56 and 0.15-0.45% of dry matter, respectively, and these figures almost exceeded the required dietary levels for sheep. There was no obvious changes in mineral content of forages between the seasons of rainy and dry, or among regions. In blood Ca level, more than a half of goats (57.9%) without supplement showed the level below the lower limit, and the low level was not improved even when they fed with some supplemental concentrates. The plasma levels of Mg and P were satisfactory, referring to the lower limit of normal level in goats. It is, therefore, necessary to decide the requirement and to establish a most suitable technique for supplying Ca to grazing goats in Luzon Island.

Oscillometry-Defined Small Airway Dysfunction in Patients with Chronic Obstructive Pulmonary Disease

  • Amit K. Rath;Dibakar Sahu;Sajal De
    • Tuberculosis and Respiratory Diseases
    • /
    • 제87권2호
    • /
    • pp.165-175
    • /
    • 2024
  • Background: The prevalence of small airway dysfunction (SAD) in patients with chronic obstructive pulmonary disease (COPD) across different ethnicities is poorly understood. This study aimed to estimate the prevalence of SAD in stable COPD patients. Methods: We conducted a cross-sectional study of 196 consecutive stable COPD patients. We measured pre- and post-bronchodilator (BD) lung function and respiratory impedance. The severity of COPD and lung function abnormalities was graded in accordance with the Global Initiative for Chronic Obstructive Lung Disease (GOLD) guidelines. SAD was defined as either difference in whole-breath resistance at 5 and 19 Hz > upper limit of normal or respiratory system reactance at 5 Hz < lower limit of normal. Results: The cohort consisted of 95.9% men, with an average age of 66.3 years. The mean forced expiratory volume 1 second (FEV1) % predicted was 56.4%. The median COPD assessment test (CAT) scores were 14. The prevalence of post-BD SAD across the GOLD grades 1 to 4 was 14.3%, 51.1%, 91%, and 100%, respectively. The post-BD SAD and expiratory flow limitation at tidal breath (EFLT) were present in 62.8% (95% confidence interval [CI], 56.1 to 69.9) and 28.1% (95% CI, 21.9 to 34.2), respectively. COPD patients with SAD had higher CAT scores (15.5 vs. 12.8, p<0.01); poor lung function (FEV1% predicted 46.6% vs. 72.8%, p<0.01); lower diffusion capacity for CO (4.8 mmol/min/kPa vs. 5.6 mmol/min/kPa, p<0.01); hyperinflation (ratio of residual volume to total lung capacity % predicted: 159.7% vs. 129%, p<0.01), and shorter 6-minute walk distance (367.5 m vs. 390 m, p=0.02). Conclusion: SAD is present across all severities of COPD. The prevalence of SAD increases with disease severity. SAD is associated with poor lung function and higher symptom burden. Severe SAD is indicated by the presence of EFLT.