• 제목/요약/키워드: P waves

검색결과 470건 처리시간 0.031초

미생물 발효 영지버섯 추출액의 다당체에 관한 연구 (Studies on the Polysaccharide of Ganoderma lucidium Extract by Microorganism Fermentation)

  • 황유연;정명수;김혜자;이기남
    • 동의생리병리학회지
    • /
    • 제21권6호
    • /
    • pp.1506-1512
    • /
    • 2007
  • In order to investigate the totale yield, the content of soluble polysaccharide and the others of FEW extract from the yeast fermentated Ganoderma lucidium by supersonic method, the yeast strain was inoculated after pretreatment and subsequently followed fermentation and supersonic extract. The main construction of the extract method is composed of the main glucose and together with the xylose, fucose, galactose and mannose. Results show that because of the generated lactic acid and ethanol, pH value of extract decreases and the safety as well as the preservation is improved. The extract yield, the total soluble polysaccharide, SOD-like activity, cytotoxic effect and growth inhibitory effect against cancer cell line are much higher in FE method than RE method, especially FEW3 extracts fermented during 24hrs. It is concluded that yeast fermentation makes the extract yield increase because of the cell disintegration, the useful ingredients of the germ body, the metabolic products, the insoluble ingredients due to the generation of ethanol, and the cell fragmentation caused by the supersonic waves vibration. Content of generated ethanol, total soluble polysaccharide and extract yield all increase during the fermentation time from 24 to 72 hours and the optimum fermentation condition is at $27^{\circ}C$ for 72 hours. The bitter taste and smell of the Ganoderma lucidium extract is diminished, fragrant-bitter taste and smell is generated so that the whole functional quality is improved.

감쇠판에 의한 원기둥의 상하운동 저감 모형시험 (Model Test for Heave Motion Reduction of a Circular Cylinder by a Damping Plate)

  • 고혁준;김정록;조일형
    • 한국해양공학회지
    • /
    • 제27권4호
    • /
    • pp.76-82
    • /
    • 2013
  • Motion reduction of an offshore structure at resonant frequency is essential for avoiding critical damage to the topside and mooring system. A damping plate has a distinct advantage in reducing the motion of a floating structure by increasing the added mass and the damping coefficient. In this study, the heave motion responses of a circular cylinder with an impermeable and a permeable damping plate attached at the bottom of the cylinder were investigated thru a model test. The viscous damping coefficients for various combinations of porosity were obtained from a free-decay test by determining the ratio between any pair of successive amplitudes. Maximum energy dissipation occurred at a porous plate with a porosity P = 0.1008. Experimental results for regular and irregular waves were compared with an analytical solution by Cho (2011). The measured heave RAO and spectrum reasonably followed the trends of the predicted values. A significant motion reduction at resonant frequency was pronounced and the heaving-motion energy calculated by the integration of the area under the heave motion spectrum was reduced by more than 75% by the damping plate. However, additional energy dissipation by eddies of strong vorticity and flow separation inside a porous damping plate was not found in the present experiments.

차감 동작 기법 기반의 효율적인 R파 검출 (Efficient R Wave Detection based on Subtractive Operation Method)

  • 조익성;권혁숭
    • 한국정보통신학회논문지
    • /
    • 제17권4호
    • /
    • pp.945-952
    • /
    • 2013
  • QRS 영역 중 R파는 ECG 신호 중 가장 큰 대표 신호라 할 수 있으며, 이 점을 기준으로 다양한 특징점을 검출하기 때문에 R파의 검출성능을 높이기 위해 많은 노력을 기울여 왔다. 하지만 R파 검출은 여러 종류의 잡음성분들로 인하여 이를 분석하는데 어려움을 준다. 또한 QRS 영역의 진폭과 유사한 T파나 P파를 R파로 오인함으로써 검출의 어려움이 발생한다. ECG 신호처리는 하드웨어 및 소프트웨어 자원에 대한 효율성을 고려해야 하며, 소형화 및 저 전력을 위해 단순해야 한다. 즉, 최소한의 연산량으로 정확한 R파를 검출함으로써 다양한 부정맥을 분류할 수 있는 적합한 알고리즘의 설계가 필요하다. 따라서 본 연구에서는 차감 동작 기법(Subtractive Operation Method, 이하 SOM) 기반의 심전도 신호의 R파 검출 방법을 제안한다. 이를 위해 형태 연산을 통한 전처리 과정과 경험적 문턱값과 차감신호를 통해 R파를 검출하였으며, 검출의 효율성을 위하여 RR 간격을 이용한 동적 역탐색 기법을 적용하였다. 제안한 알고리즘의 R파 검출 성능을 평가하기 위해서 MIT-BIH 부정맥 데이터베이스를 사용하였다. 성능평가 결과, R파는 평균 99.41%의 검출결과가 나타났다.

부소파제의 부체 개발을 위한 기초적 실험 연구 (A Preliminary Experiment Study for Development of Floater of Floating Breakwater)

  • 정동호;김현주;김진하;문덕수
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제9권3호
    • /
    • pp.141-147
    • /
    • 2006
  • 해양의 활용범위를 확대시키기 위해서 방파제는 필수적인 요소이며 특히 친환경적인 부소파제의 활용은 증대될 것으로 기대된다. 본 연구에서는 친환경 소재인 폴리에틸렌 파이프와 시트를 활용하여 새로운 개념의 부소파제용 부체를 개발하며, 이에 대한 소파 성능평가를 위하여 기초적 실험연구를 수행한다. 입사되는 파랑은 연결된 파이프와 시트를 통과하면서 일부는 반사되고 일부는 투과되는데, 투과되는 파랑은 파이프를 지나면서 와류유기가 발생하여 파랑 에너지가 소멸된다. 따라서 입사파랑 에너지를 감소시킬 수 있다. 개발된 부체의 성능평가를 위하여 규칙파 및 붙규칙파에 대한 수리모형 실험을 수행한다. 입사파랑 주기가 6초 이하 조건에서는 소파 성능이 양호하였으나, 장주기의 입사파랑에 대해서는 부체 전체가 해수면과 같이 거동하면서 소파성능을 거의 나타내지 못하였다. 향후 소파성능 개선을 위한 추가적인 연구가 요구되어진다.

  • PDF

위전도 계측시스템의 개발 (Development of Electrogastrography System)

  • 한완택;김인영;김원기;박기원;김희찬;손정일;이풍렬;이종철
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.403-406
    • /
    • 1997
  • Electrogastrogaphy(EGG) is the technique by which gastric myoelectrical activity is recorded noninvasively, from electrodes on the abdominal skin. Despite many attempts made over the decades, the clinical application of the EGG signal has not improved to the identification of waveform characteristics using comparison of EGG signal to be detected other EGG system. Cutaneous measurements of EGG are yet to be standardized in methods of detection and analysis. This may be responsible in part for some of the variability in the results. Thus, we develope EGG system composed of amplifiers, analysis methods, patient database or standardization. we introduce configurations of EGG system and their functions. Several important EGG parameters are introduced, including the dominant frequency and power of the EGG, the relative, period EGG-dominant frequency and power, the instability coefficient of EGG-dominant frequency and power, standard deviation, the percentage of running spectrum activity of gastric slow waves.

  • PDF

촌관척(寸關尺)부의 검측한 부정맥과 Electrocardiographic 결과의 한의학적 검토 (The Oriental Medical Study about the Arrythmia Detected on the Radial Pulses and the Result of ECG.)

  • 류희영;허은정;김지현;윤정미;전성하
    • 동의신경정신과학회지
    • /
    • 제19권2호
    • /
    • pp.165-193
    • /
    • 2008
  • Objective: The ECG which used for this paper, is analysis result from alogrisms of arrythmia, and we have studied that how we could certain Cold(寒)type or Heat(熱) type and that Deficiency(虛) type or Excess(實)type of organs from various special diseases, and we obtained like these results. Method & Conclusion: 1. we depend on our examination about Pulse(脈) because we can't discriminate arrythmia using ECG analysis instruments. 2. We obtained that Cold(寒) type diseases had wave that prolonged above normal baseline and ST wave which had downward aptitude. 3. We obtained that Heat(熱) type diseases had the fibrillation which had shortend wave that compare to normal and had downward aptitude or negative aptitude. 4. We obtained that Respiratory system (肺) diseases had wave that is within normal or is short of normal range and had much fluctuation in potential difference or trans on P wave. 5. The character of EKG which presented about diseases of gastric systems is prolonged above narmal range of wave, and the ECG had represented mixed wave with Heat(熱) type when accompany inflammatory in gastric system. 6. The wave of Blood Stasis(瘀血) type had upward aptitude of QRS wave, and the wave of anemia or blood loss type(少血) had downward aptitude of QRS wave, the wave which had both Cold(寒)) and Heat (熱) represented mixed waves. 7. The Knotted Pulse(結脈) and Intermittent Pulse(代脈)is corresponded with sinus brady cardia, and the Swift Pulsle(疾脈) is corresponded with fibrillation. 8. We pay attention to the relations of formations about pressures pulse from formations of EMD( electromechanical dissociation ). Result : From these results, we will have to study about ECG which using in tests of change of Parkinsons disease.

  • PDF

Correlation between terahertz characteristics and defect states in LTG-InGaAs

  • 박동우;김준오;이상준;김창수;이대수;노삼규;강철;기철식;김진수
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.243-243
    • /
    • 2010
  • Low-temperature grown (LTG) InGaAs epilayers were grown by MBE technique for studying a correlation between terahertz (THz) emission and the intrinsic defects. The 1.2-um-thick Be-compensated LTG-InGaAs epilayers were prepared on SI-InP:Fe substrate at $200-250^{\circ}C$, and subsequently in-situ annealed under As environment at $550^{\circ}C$ for 5-30 minutes. The carrier concentration/mobility and the crystalline structure were analyzed by the Hall effect and the x-ray diffraction (XRD), respectively, and the carrier lifetime were determined by the fs time-resolved pump-probe spectroscopy. THz generation from LTG-InGaAs was carried out by a Ti-sapphire laser (800 nm) of a pulse width of 190 fs at a repetition of 76 MHz. Figure shows the spectral amplitude of generated waves in the THz region. As the growth temperature of epilayer increases, the amplitude is enhanced. However, two samples grown at $200^{\circ}C$, as-grown and annealed, show almost no difference in the spectral amplitude. This suggests that the growth temperature is critical in the formation of defect states involved in THz emission. We are now investigating the correlations between the XRD band attributed to defects, the Hall parameter, and the spectral amplitude of generated THz wave.

  • PDF

Period Study and Light Curve Synthesis of BD Andromedae

  • 김천휘;송미화;윤요나;한원용;최영준
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.141.1-141.1
    • /
    • 2011
  • New CCD BVR light curves of BD And are presented. Our light curves with nearly equal depths for both primary and secondary eclipses show well-defined photometric waves outside eclipse for all of BVR bandpasses. The orbital period is greatly revised as $0.^d92580519$ which is twice longer than that known previously. Sixteen timings from our observations and thirteen ones from the SuperWASP measurements were calculated. All available timings over 76 years, including ours, were analyzed to figure out the dynamical behavior of the system. It was found that the recent CCD O-C residuals varied in a cyclical way with a period of $9.^y18$ and a semi-amplitude of $0.^d0046$. The secondary period of $9.^y18$ is the most shortest one among those which have been ever found in the short period RS CVn binary stars. The periodic variation most likely arises from the light-travel time effect due to a low-mass ($m_3{\sim}0.88\;M_{\odot}$) tertiary companion moving in an orbit with an large eccentricity ($e_3$=0.70) and a low inclination ($i_3{\sim}28^{\circ}$). The Applegate mechanism could not operate properly in both components because the model parameters require too much large luminosity changes of ${\Delta}L/L_{p,s}$ > 10. The new light curves were synthesized using the 2003 version of Wilson-Divinney code. It was found useful to model two huge spots on the surface of the hotter star and a third-light in order to minimize the residuals from the observations. Astronomical basic parameters were deduced from our photometric solution.

  • PDF

압전 필름과 전도성 섬유를 이용한 맥파 전달 속도 측정을 위한 센서의 제작 및 성능평가 (Fabrication and Evaluation of Sensor for Measuring Pulse Wave Velocity using Piezo Film and Conductive Textile)

  • 김정채;지선하;유선국
    • 센서학회지
    • /
    • 제21권2호
    • /
    • pp.135-143
    • /
    • 2012
  • Arterial stiffness is causing the serious problems for human who is suffered from hypertension and metabolic syndrome. So it is important that measure the arterial stiffness for early prevention. Many researches point out that pulse wave velocity(PWV) is the reliable and simple method to predict arterial stiffness. In this paper, we developed the sensing parts that detect the pulse wave and ECG by using piezoelectric film and conductive textile with elastic band. Our system could detect 3ch pulse wave and ECG. Simultaneously, our algorithm extracts the features for calculating the delays among pulse waves. The delays are the significant parameter to estimate PWV, thus we design the experiment for evaluating the performance of our sensing parts. The reference is PP-1000(HanByul Meditech, Korea) that is good for performance evaluation. As a result, the start point of the pulse wave was the most reliable feature for comparing with PP-1000(r=0.691, P=0.00). The results between two operators showed that there is only a slight difference in the reproducibility of the devices. In conclusion, we assume that the suggested sensor could be more comfortable and faithful method for arterial stiffness.

촌관척(寸關尺)부의 검측한 부정맥과 electrocardiographic 결과와의 한의학적 검토 (The oriental medical study about the arrythmia detected on the radial pulses and the result of ECG)

  • 류희영;허은정;김지현;윤정미;전성하
    • 대한한의정보학회지
    • /
    • 제14권1호
    • /
    • pp.81-106
    • /
    • 2008
  • The ECG which used for this paper, is analysis result from alogrisms of arrythmia, and we have studied that how we could certain Cold(寒 )type or Heat(熱) type and that Deficiency(虛) type or Excess(實)type of organs from various special diseases, and we obtained like these results. 1. we depend on our examination about Pulse(脈) because we can't discriminate arrythmia using EKG analysis instruments. 2. We obtained that Cold(寒) type diseases had wave that prolonged above normal baseline and ST wave which had downward aptitude. 3. We obtained that Heat(熱) type diseases had the fibrillation which had shortend wave that compare to normal and had downward aptitude or negative aptitude. 4. We obtained that Respiratory system (肺) diseases had wave that is within normal or is short of normal range and had much fluctuation in potential difference or trans on P wave. 5. The character of EKG which presented about diseases of gastric systems is prolonged above narmal range of wave, and the EKG had represented mixed wave with Heat(熱) type when accompany inflammatory in gastric system. 6. The wave of Blood Stasis(瘀血) type had upward aptitude of QRS wave, and the wave of anemia or blood loss type(少血 ) had downward aptitude of QRS wave, the wave which had both Cold(寒) and Heat (熱) represented mixed waves. 7. The Knotted Pulse(結脈) and Intermittent Pulse(代脈) is corresponded with sinus brady cardia, and the Swift Pulsle(疾脈) is corresponded with fibrillation. 8. We pay attention to the relations of formations about pressures pulse from formations of EMD( electromechanical dissociation ). From these results, we will have to study about EKG which using in tests of change of Parkinsons disease.

  • PDF