• 제목/요약/키워드: P/C Based Method

검색결과 944건 처리시간 0.033초

Ampoule-tube 방식을 이용한 n-type $GaAs_{0.60}P_{0.40}$에 Zn 확산과 전계 발광 특성 (Zn Diffusion using by Ampoule-tube Method into n-type $GaAs_{0.60}P_{0.40}$ and the Properties of Electroluminescence)

  • 김다두;소순진;박춘배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 제5회 영호남 학술대회 논문집
    • /
    • pp.59-62
    • /
    • 2003
  • Our Zn diffusion into n-type $GaAs_{0.60}P_{0.40}$ used ampoule-tube method to increase IV. N-type epitaxial wafers were preferred by $H_2SO_4$-based pre-treatment. $SiO_2$ thin film was deposited by PECVD for some wafers. Diffusion times and diffusion temperatures respectability are 1, 2, 3 hr and 775, $805^{\circ}C$. LED chips were fabricated by the diffused wafers at Fab. The peak wavelength of all chips showed about 625~650 nm and red color. The highest IV is about 270 mcd at the diffusion condition of $775^{\circ}C$, 3h for the wafers which didn't deposit $SiO_2$ thin films. Also, the longer diffusion time is the higher IV for the wafers which deposit $SiO_2$ thin films.

  • PDF

사질토지반에서 콘관입저항치 $q_c$에 의한 단말뚝의 극한수평단위지지력 평가 (Estimation of Ultimate Lateral Resistances of Piles Using CPT Cone Resistance in Sand)

  • 김민기;경두현;홍정무;이준환
    • 한국지반공학회논문집
    • /
    • 제24권11호
    • /
    • pp.71-77
    • /
    • 2008
  • 본 연구에서는 CPT 결과인 콘관입저항치 $q_c$값을 이용하여 말뚝의 극한수평단위지지력을 산정법을 제안하고자 한다. 이는 기존의 지반물성평가를 이용하여 평가되어 오던 간접적인 방법과 비교하여, 현장측정치의 직접적 적용을 위한 극한수평단위지지력 산정법 개발을 목표로 하고 있다. 점착력이 없는 사질토 지반을 대상으로 측정된 콘관입저항치 $q_c$값은 사질토지반에서 중요한 요소인 상대밀도, 연직응력, 수평응력에 대한 함수로 표현되며, 이는 기존에 제안되어온 극한수평지지력의 산정에 고려되는 요소들과 유사하다. 이러한 역학적 유사성을 바탕으로 CPT결과를 이용한 극한수평단위지지력 산정식을 제안하였다. 이는 점착력이 없는 사질토에 대상으로 하고 있으며, 그에 대한 해석을 위해 해석대상지반을 대상으로 제안된 산정식의 신뢰성을 확보하였다 극한수평단위지지력의 측정값과 예측값에 따른 비교에 대해 표준편차는 0.279를 보였으며, COV는 0.272의 값을 보여 측정된 극한수평단위지지력과 대체적으로 유사한 결과를 보였으며, 전반적으로 제안식에 의해 예측된 극한수평단위지지력이 실내모형실험을 통한 측정값에 근접함을 알 수 있다.

POSITIVE SOLUTION FOR A CLASS OF NONLOCAL ELLIPTIC SYSTEM WITH MULTIPLE PARAMETERS AND SINGULAR WEIGHTS

  • AFROUZI, G.A.;ZAHMATKESH, H.
    • Journal of applied mathematics & informatics
    • /
    • 제35권1_2호
    • /
    • pp.121-130
    • /
    • 2017
  • This study is concerned with the existence of positive solution for the following nonlinear elliptic system $$\{-M_1(\int_{\Omega}{\mid}x{\mid}^{-ap}{\mid}{\nabla}u{\mid}^pdx)div({\mid}x{\mid}^{-ap}{\mid}{\nabla}u{\mid}^{p-2}{\nabla}u)\\{\hfill{120}}={\mid}x{\mid}^{-(a+1)p+c_1}\({\alpha}_1A_1(x)f(v)+{\beta}_1B_1(x)h(u)\),\;x{\in}{\Omega},\\-M_2(\int_{\Omega}{\mid}x{\mid}^{-bq}{\mid}{\nabla}v{\mid}^qdx)div({\mid}x{\mid}^{-bq}{\mid}{\nabla}v{\mid}^{q-2}{\nabla}v)\\{\hfill{120}}={\mid}x{\mid}^{-(b+1)q+c_2}\({\alpha}_2A_2(x)g(u)+{\beta}_2B_2(x)k(v)\),\;x{\in}{\Omega},\\{u=v=0,\;x{\in}{\partial}{\Omega},$$ where ${\Omega}$ is a bounded smooth domain of ${\mathbb{R}}^N$ with $0{\in}{\Omega}$, 1 < p, q < N, $0{\leq}a$ < $\frac{N-p}{p}$, $0{\leq}b$ < $\frac{N-q}{q}$ and ${\alpha}_i,{\beta}_i,c_i$ are positive parameters. Here $M_i,A_i,B_i,f,g,h,k$ are continuous functions and we discuss the existence of positive solution when they satisfy certain additional conditions. Our approach is based on the sub and super solutions method.

Vacuum 'brusher' for the alignment treatment of the large area LCD sub strates

  • Yaroshchuk, O.V.;Liu, P.C.;Lee, C.D.;Lee, C.Y.;Kravchuk, R.M.;Dobrovolskyy, A.M.;Protsenko, I.M.;Goncharov, A.A.;Lavrentovich, O.D.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.768-773
    • /
    • 2005
  • We present an overview of our new method of liquid crystal (LC) alignment based on the anisotropic etching of the alignment layers with a directed plasma flux. The method is realized by the use of anode layer source of "race track" geometry generating two "sheets" of accelerated plasma. These sheets are directed obliquely to the treated substrates. The static and dynamic irradiation regimes have been explored. The optimized processing conditions and materials are discussed. The technique yields an excellent uniformity of liquid crystal alignment of planar, tilted and vertical types. It is shown that the new method can be easily adapted for the alignment treatment of large area substrates used in the modern LCD manufacturing process.

  • PDF

한국산 P.V.C.의 생물학적 안정도 및 적합성에 대한 실험적 고찰 (An experimental study on the biological safety and compatability of P.V.C. made in Korea)

  • 선경
    • Journal of Chest Surgery
    • /
    • 제17권1호
    • /
    • pp.157-166
    • /
    • 1984
  • These biologic test procedures are designed to test the suitability of P.V.C. made in Korea intended for parenteral preparation, which were based on the U.S. Pharmacopeia XIX "Biologic Test-Plastic Container", Official from July 1, 1975. Healthy adult human blood and rabbits weighing 2\ulcorner.2Kg were used for test materials. Sample P.V.C. were sampled from the medical equipments made in Korea randomly and Control P.V.C. were sampled from the standardized Cobe and Polystan P.V.C. tubes. P.V.C. extract was prepared from a homogeneous P.V.C. samples by incubating 60 square centimeters of the sample per 20 millimeters of sterile pyrogen-free saline at 70\ulcorner for 72 hours or autoclaving at 120\ulcorner for 1 hour. The Implantation Test was designed to evaluate the reaction of living tissue to the plastic by the method of the implantation of the Sample itself into animal tissue. The Systemic Injection Test, the Intracutaneous Test, and the remainders were designed to determine the biological response of animals to plastics by the single-dose injection of specific extracts prepared from a Sample. The results are as follows; 1.Implantation Test - No significant difference for reactions was noted between the Sample treated animal and the Control after 72 hours of implantation. 2.Systemic Toxicity Injection Test - No sign of toxicity and/or death immediately after injection and at 4, 24, 48 hours respectfully after injection. 3.Intracutaneous Test - None of the animals treated with the Sample showed a significantly greater reaction than the observed in the animals treated with Blank. 4.Pyrogen Assay-Only one animal treated with the Sample showed the maximal rise of rectal temperature about 0.2\ulcorner after 3 hours of injection, but remainders showed no change. 5.Hemolytic Index - The positive Control tube of distilled water exhibited complete hemolysis while the negative Control tube and P.V.C. extract were negative demonstrating no hemolysis. 6.Cell Morphology of Erythrocytes and Leukocytes on Stored, Heparinized Human Blood -- There was no significant difference in the morphology of either the Control or Sample extract. 7.Clotting Mechanism of Human Blood in vitro - After allowing to the P.V.C. extract at room temperature for 5 Hours and at 10\ulcorner for 24 hours, there was no appreciable difference in Prothrombin Time under these conditions. 8.Clotting Mechanism of Rabbit in vivo - At the termination of 5 days after intraperitoneal injection of the P.V.C. extract, no significant changes in Clotting Time were observed. According to the above results, it could be concluded that the P.V.C. made in Korea was acceptable for parenteral preparation, especially treated with physiologic saline and/or human blood.man blood.

  • PDF

단상계 침지냉각 기술이 적용된 Li-ion계 배터리 발열특성에 관한 연구 (A Study on Heating Characteristics of Li-ion Battery Applicated Single-phase Immersion Cooling Technology)

  • 김운학;강석원;신기석
    • 한국재난정보학회 논문집
    • /
    • 제18권1호
    • /
    • pp.163-172
    • /
    • 2022
  • 연구목적: Li-ion 배터리의 효율적인 열관리 기술을 확보하기 위하여 Single&-phase 침지 냉각 기술을 적용한 시스템의 실험을 통하여 적용가능성을 확인하고자 하였다. 연구방법: LG-Chem에서 생산된 JH3 파우치 셀을 사용하여 14S2P 모듈을 제조하여 미국 카길사에서 생산된 식물성계 냉각유체에 침지한 후 0.3C~1C 속도로 충방전을 시행하여 열분포를 확인하였다. 연구결과: 침지냉각 기술로 배터리 모듈을 40℃ 이하의 온도로 관리할 수 있으며, 침지액의 분자구조 변화가 없다는 결과를 도출하였다. 결론: 침지냉각 방식이 Li-ion 배터리 열관리에 적용 가능함을 확인하였다.

액제 정밀계량장치를 이용한 액제 자동조제 시스템개발 (Development of Automatic Nutrient-Solution Control System Using a Low -Cost and Precise Liquid Metering Device)

  • 류관희;홍순호;이규철;이정훈;황호준
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1997년도 하계 학술대회 논문집
    • /
    • pp.89-98
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution control system for small-scale growers. The nutrient-solution control system consisted of a low-cost and precise metering device and a personal computer. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-soIution. The performance of the nutrient-solution control system was evaluated through the control of EC and pH while compared with those of commercial nutrient-solution control system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. An automatic nutrient-solution control system based on a low-cost and precise metering device was developed. 2. The developed system controlled EC and pH within $\pm$0.05 mS/cm and $\pm$0.2 pH full scale error respectively at $24^{/circ}C$. 3. When using the commercial system, the controlled values of EC and pH of the 500l of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at $22^{/circ}C$. 4. The developed nutrient-solution control system showed $\pm$0.05 mS/cm of deviation from the setting EC value over the experimental cultivation period. 5. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

탄화규소 반도체의 구리 오옴성 접촉 (Copper Ohmic Contact on n-type SiC Semiconductor)

  • 조남인;정경화
    • 마이크로전자및패키징학회지
    • /
    • 제10권4호
    • /
    • pp.29-33
    • /
    • 2003
  • n-형 탄화규소 반도체에 대한 구리금속을 이용하여 오옴성 접촉 구조를 제작하였다. 제작된 구리접촉에 대해 후속열처리 조건과 금속접촉 구조에 따른 재료적, 전기적 성질의 변화를 조사하였다. 금속접촉의 오옴성 성질은 금속박막의 구조 뿐 아니라 열처리조건에 대해서도 크게 좌우됨을 알 수 있었다. 열처리는 급속열처리 장치를 이용한 진공상태 및 환원 분위기에서 2단계 열처리방식을 통하여 시행하였다. 접촉비저항의 측정을 위해 TLM 구조를 만들었으며 면저항 ($R_{s}$), 접합저항 ($R_{c}$), 이동거리 ($L_{T}$), 패드간거리 (d), 전체저항 ($R_{T}$) 값을 구하여 알려진 계산식에 의해 접촉비저항 ($p_{c}$) 값을 추정하였다. 진공보다 환원분위기에서 후속 열처리를 수행한 시편이 양호한 전기적 성질을 가짐을 알 수 있었다. 가장 양호한 결과는 Cu/Si/Cu 구조를 가진 금속접촉 결과이었으며 접촉비저항 ($p_{c}$)은 $1.2\times 10^{-6} \Omega \textrm{cm}^2$의 낮은 값을 얻을 수 있었다. 재료적 성질은 XRD를 이용하여 분석하였고 SiC 계면 상에 구리와 실리콘이 결합한 구리 실리사이드가 형성됨을 알 수 있었다.

  • PDF

Characterization of Paraplantaricin C7, a Novel Bacteriocin Produced by Lactobacillus paraplantarum C7 Isolated from Kimchi

  • Lee, Kwang-Hee;Park, Jae-Yong;Jeong, Seon-Ju;Kwon, Gun-Hee;Lee, Hyong-Joo;Chang, Hae-Choon;Chung, Dae-Kyun;Lee, Jong-Hoon;Kim, Jeong-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권2호
    • /
    • pp.287-296
    • /
    • 2007
  • A Lactobacillus paraplantarum strain producing a bacteriocin was isolated from kimchi using the spot-on-the lawn method and named L. paraplantarum C7 [15]. The bacteriocin, paraplantaricin C7, was found to inhibit certain Lactobacillus strains, including L. plantarum, L. pentosus, and L. delbrueckii subsp. lactis. It also inhibited Enterococcus faecalis, yet did not inhibit most of the other LAB (lactic acid bacteria) tested. The maximum level of paraplantaricin C7 activity was observed under the culture conditions of $25^{\circ}C$ and a constant pH of 4.5. Paraplantaricin C7 retained 90% of its activity after 10 min of treatment at $100^{\circ}C$ and remained stable within a pH range of 2-8. Based on a culture supernatant, paraplantaricin C7 was purified by DEAE-Sephacel column chromatography and $C_{18}$ reverse-phase HPLC. SDS-PAGE and activity staining were then conducted using the purified paraplantaricin C7, and its molecular mass determined to be about 3,800 Da. The 28 N-terminal amino acids from the purified paraplantaricin C7 were determined, and the structural gene encoding paraplantaricin C7, ppnC7, was cloned by PCR using degenerate primers based on the N-terminal amino acid sequence. The nucleotide sequences for ppnC7 and other neighboring orfs exhibited a limited homology to the previously reported plantaricin operon genes. Paraplantaricin C7 is a novel type II bacteriocin containing a double glycine leader sequence.

Dispersive Solid Phase Extraction을 사용한 우유 내 잔류농약 다성분 동시 분석법 비교연구 (Comparative Evaluation of the Analytical Methods used to Determine Pesticide Residues in Milk via Dispersive Solid Phase Extraction)

  • 오남수;신용국;이지영;백승천
    • Journal of Dairy Science and Biotechnology
    • /
    • 제33권1호
    • /
    • pp.27-34
    • /
    • 2015
  • 본 연구에서는 dispersive-SPE를 사용하여 간편하고, 신속하며, 경제적인 우유 내 19종 잔류농약의 동시 다성분 분석법을 설정하고자 하였다. Liquid-liquid partitioning method와 low-temperature cleanup method를 적용한 추출방법과 PSA 및 PSA + C18의 sorbent가 사용된 dispersive-SPE를 사용한 정제방법을 비교 실험하였으며, GC/MS의 선택이온 검색법(selected ion monitoring, SIM)으로 정량 분석하였다. matrix-matched standards와 matrix-free standards를 사용하여 분석방법의 matrix enhancement effect를 확인하였고, 분석방법 설정을 위한 비교실험의 결과, low-temperature cleanup 방법으로 추출하여 dispersive-SPE(PSA + C18)로 정제하는 방법이 시료 추출물의 간섭물질을 제거하는데 가장 효과적이고, 첨가한 $1{\mu}g/mL$에 대한 개별 농약 성분의 회수율 또한 전체적으로 가장 높은 수준을 나타내었으며, 모든 농약 성분의 RSD(%)가 20% 이하로서 기준에 적합한 재현성을 나타내었다.

  • PDF