• Title/Summary/Keyword: Ozone density

Search Result 98, Processing Time 0.033 seconds

Measurement Technique of Ozone Density by Using UV Sensor System

  • Trung, Nguyen Huu;Van Men, Le;Van Hieu, Nguyen
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.80-86
    • /
    • 2015
  • There are many studies and products using a test paper impregnated with chemical solution can react with ozone. The color of a test paper can indicate the concentration of ozone. The purpose of this research is to design and manufacture a system using ultraviolet light source to measure the ozone density. This new technique is based on the characteristic of decomposition from ozone into oxygen under ultraviolet light. We used two sources of ultraviolet light including UV lamp and UVLED to determine the decomposition of ozone. This system is built with the electronic components, sensors and sealed pump tube to measure the ozone density in units of $g/cm^3$,ppm,ppb. In this paper,, we present some initial results of measuring the ozone density from ozone generator after completing inspection for safety.

Ozone Condensation and Stable Supply by an Adsorption Method

  • Yang, Seong-Ho;Park, Yong-Pil;Lee, Joon-Ung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.121-125
    • /
    • 2000
  • An ozone condenser by a selective adsorption on the silica gel surface is constructed. Ozone density is evaluated by three methods; ultraviolet absorption, thermal decomposition and Q-mass analyzing methods. Thermal decomposition method is found to be available to the density evaluation from dilute to highly condensed ozone. The highest ozone density condensed by the adsorption method is evaluated to be 97 mol%.

  • PDF

Ozone Dentisity Estimation and Stable Supply in the Growth Process of BSCCO Thin Film

  • Lee, Hee-Kab;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.45-49
    • /
    • 2000
  • An ozone condenser by a selective adsorption on the silica gel surface is constructed. Ozone density is evaluated by three methods; ultraviolet absorption, thermal decomposition and Q-mass analyzing methods. Thermal decomposition method is found to be available to the density evaluation from dilute to highly condensed ozone. The highest ozone density condensed by the adsorption method is evaluated to be 97 mol%.

  • PDF

Ozone Density Estimation and Stable Supply in the Thin Film Growth

  • Lim, Jung-Kwan;Park, Yong-Pil;Oh, Geum-Gon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.2
    • /
    • pp.42-45
    • /
    • 2001
  • An ozone condensation system is evaluated from the viewpoint of an ozone supplier for Bi-superconductor thin film growth. An ozone condenser by a selective adsorption on the silica gel surface is constructed. Ozone density is evaluated by three methods; ultraviolet absorption, thermal decomposition and Q-mass analyzing methods. Thermal decomposition method is found to be available to the density evaluation from dilute to highly condensed ozone. The highest ozone density condensed by the adsorption method is evaluated to be 97 mol%.

  • PDF

High Efficiency Ozone Generation Using a Pyramid-Project-Embossed Rod-to-Cylinder Electrode and a Pulse Corona Discharge (도깨비봉형 오존발생장치이 펄스커로나 방전에 의한 오존 발생 특성)

  • 문재덕;이근택
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.8
    • /
    • pp.650-657
    • /
    • 1989
  • The conversion efficiency of an ozone generator can be significantly improved by modifying the discharge electrode of a helical strip line rod-to-cylinder type ozone generator to a pyramid-project-embossed rod, and by using a pulse corona discharge. Parametric studies have been carried out to obtain optimum values of peak pulse voltage, pulse forming capacitance, feeder cable and ozone generator capacitance, interelectrode spacing and corona tip density of ozone generator, and feed air flow rate and temperature. The generated ozone concentration was very dependent upon the value of pulse forming capacitance, feeder cable and ozone generator capacitance, and corona tip density. Maximum conversion efficiency was obtained with a pulse forming capacitance of about 500pF, 75pF matched feeder cable and ozone generator, and a corona tip density of 16mm. When operated at optimum values, ozone yield of 79, 99, 80 g/KWh for the different interelectrode type ozone generators tested were obtained, which are approximately 30% higher than that of an industrial ozone generator.

  • PDF

A Study on the Development of High Density Ozone Water Cleaning System for Herb Medicine (고농도 오존수를 이용한 한약재 세척기기에 대한 연구)

  • Kim, Jeong-Ho;Bang, Byeong-Hun;Lee, Sang-Hwa;Kim, Sung-Hee
    • Journal of Acupuncture Research
    • /
    • v.29 no.2
    • /
    • pp.9-14
    • /
    • 2012
  • Objectives : This study was designed to evaluate the pesticide residue of herb medicine through high density ozone water cleaning system. Materials and Methods : We purchased ginseng(Panax ginseng) on market and sprayed pesticides (Diazinon) on ginseng. We analyzed pesticide residue according to washing methods(untreated, ozone water cleaning, ultrasonic cleaning, Water cleaning). As a result of each washing methods, in ozone water cleaning method pesticide residue was much less remained than in Ultrasonic Cleaning method and water cleaning method. Conclusions : High density ozone water cleaning is the best method for removing pesticides of herbal medicine.

Stomata Density and Size of Acer palmatum to the Elevated Ozone

  • Ryang, Soo Zin;Woo, Su Young
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.5
    • /
    • pp.552-554
    • /
    • 2008
  • Acer palmatum was selected and its responses to elevated ozone were subsequently measured during growing periods. Ozone concentration of this study was compared to the calculated AOT40 value. A. palmatum had significantly many but small stomata size to the ozone stress. The length of stomata of A. palmatum was reduced from 5.6 to $5.0{\mu}m$ to the ozone exposure. However, the number of stomata (density) was increased from 102 to 131 in the $500{\times}500{\mu}m$ leaf area.

DEVELOPMENT OF OZONE DETECTOR FOR KSR-III AND PRELIMINARY TEST RESULTS (과학 로켓 3호용 오존 측정기 개발 및 초기 모델 시험 결과)

  • Hwang, Seung-Hyun;Kim, Jhoon;Kim, Jun-Kyu;Lee, Soo-Jin;Park, Jeong-Joo;Cho, Gwang-Rae
    • Journal of Astronomy and Space Sciences
    • /
    • v.17 no.2
    • /
    • pp.277-284
    • /
    • 2000
  • KARI(Korea Aerospace Research Institute) has measured the ozone density profiles over the Korean Peninsular since the launch of the Korean Sounding Rocket-I (KSR-I) in 1993. The purpose of ozone measurements is to obtain the stratospheric and mesospheric vertical ozone density profiles over the Korean Peninsular with solar UV radiometers. With the visible channel of the radiometer, the attitude variation of the rocket was corrected and compensated. Developed system is based on ozone detector designs onboard the KSR-I and KSR-II. We discuss the development of ozone detector which will be onboard the KSR-III and its circuit and vibration test results for EM model.

  • PDF

Improvement of Bending Stiffness in White Duplex Board by Utilization of Wood Fibers from Medium Density Fiberboard (2) Ozone treatment (백판지의 휨강성 증대를 위한 목질섬유의 이용 (2) 오존처리)

  • Seo, Yung Bum;Kim, Hyun Jun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Wood fibers for medium density fiberboard (MDF) was used in the filler layer of the white duplex board for increasing thickness and bulk of the board. The MDF fibers were treated with ozone (3% based on dry weight of the fibers), and mixed together with OCC (old corrugated container) to form paper. Ozone-treated MDF fibers gave high bulk, high tensile strength, high internal bond and fast drainage to the furnish mixed with OCC. It was shown that there were possibilities to reduced basis weight of the filler layer without loss of thickness, stiffness, and tensile strength. Furthermore, it showed the possibility to develop a new kind of board product that has high stiffness as well as high strength properties with light basis weight by application of the ozone-treated MDF fibers.

Evaluation of Advanced Oxidation Process(AOP) as a Pretreatment Process of Biological Activated Carbon in Drinking Water Treatment (정수처리에서 생물활성탄의 전처리로서 고급산화처리법의 평가)

  • Kim Woo-Hang
    • Journal of Environmental Science International
    • /
    • v.8 no.6
    • /
    • pp.725-730
    • /
    • 1999
  • The advanced oxidation process (AOP) using ozone combined with hydrogen peroxide and ultraviolet treatment were evaluated for biodegradable dissolved organic carbon (EDOC) formation and dissolved organic carbon (DOC) removal. Oxidation treatment were conducted alone or combination with ozone, hydrogen peroxide and ultraviolet processes. Ozone dosage of ozone process was varied from $0.5mg/l{\ell}\cdot}min$ to $5mg/{\ell}{\cdot}min$. Ozone/hydrogen peroxide process was done using $20mg/{\ell}{\cdot}min$ of hydrogen peroxide concentration. Ozone/ultraviolet process was irradiated with $12mW/cm^2$ of density and 254nm. Ozone dosage was varied from $0.5mg/{\ell}{\cdot}min$ to $5mg/{\ell}{\cdot}min$ at the ozone/hydrogen peroxide and ozone/ultraviolet processes too. Contact time of all the process was 20 minutes. Oxidation treatment were performed on microfiltration effluent samples. BDOC formation was reached to an optimum at ozone dosage of $1.5mg/{\ell}{\cdot}min$ in the ozone/hydrogen peroxide process and $1mg/{\ell}{\cdot}min$ in ozone/ultraviolet process, after which BDOC formation was decreased at higher ozone dosages. But BDOC formation was increased with ozone dosages increasing in ozone process. The efficiency of DOC removal was higher AOPs than ozone process. Ozone/ultraviolet proces was the highest for DOC removal efficiency in each process. THMFP. removal efficiency by ozone/ultraviolet process was higher than that by each of ozone process and ozone/hydrogen peroxide process.

  • PDF