• Title/Summary/Keyword: Ozone decomposition

Search Result 122, Processing Time 0.028 seconds

Characteristics of Residual Ozone Decomposition with Commercial Ozone Decomposition Catalyst (ODC) and Photo catalyst (상업용 오존촉매와 광촉매를 이용한 오존제거특성)

  • Byeon, Jeong-Hoon;Park, Jae-Hong;Hwang, Jung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1255-1260
    • /
    • 2004
  • Decomposition of ozone at room temperature was investigated comparatively with commercial monolithic ozone decomposition catalyst (ODC, $MnO_2$) and monolithic photo catalyst ($TiO_2$). The effects of residence time, UV (ultraviolet) light dependence and ozone concentration on the conversion was presented. UV ray was irradiated using BLB (black light blue) lamp ($315{\sim}400$ nm), supplied with a constant intensity in the reactor. The concentration of ozone in the square-shape reactor can be controlled by combining the DBD (dielectric barrier discharge) reactor with an AC high voltage supply system. The catalytic performance, in presence of UV irradiation did not show significant changes for $MnO_2$ catalyst. $TiO_2$ catalyst was the different case, which showed higher decomposition activity in presence of UV irradiation. Deactivation of catalyst detected by real-time ozone monitor for 120 hours with a constant inlet ozone concentration.

  • PDF

Evaluation of Ozone Condensation System by T.D Method

  • Lee, Hee-Kab;Park, Yong-Pil
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.2
    • /
    • pp.18-22
    • /
    • 2000
  • An ozone condensation system is evaluated from the viewpoint of an ozone supplier fro oxide thin film growth. Ozone is condensed by the adsorption method and its concentration is analyzed using the thermal decomposition method, The concentration of ozone exceeds 90mol% and ozone is supplied for a sufficiently long time to grow oxide thin films. Investigation of the ozone decomposition rate demonstrates that ozone can be transferred into the film growth chamber without marked decomposition. The ozone concentration is also evaluated using a quardrupole mass analyzer and the accuracy of this method is compared with the results of the thermal decomposition method.

  • PDF

A Study on the Treatment of Organic Wastewater by Ozone Electrolysis (유기성 폐수의 오존전해처리에 관한 연구)

  • 정홍기;이태호
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.2
    • /
    • pp.59-63
    • /
    • 1996
  • To treat certain wastewater that has alcohol and phenol, we performed the ozone electrolysis by using the titanium electrode. In this experiment, we examined decomposition voltage of organics, time for electrolysis, and removal efficiency of organics. In addition we compared the ozone oxidation electrolysis. The followings are results; 1. When it comes to the alcohol treatment in wastewater, ozone electrolysis showed higher removal efficiency than ozone oxidation or electrolysis. 2. After comparing the decomposition rate of methylalcohol, ethylalcohol, and prophylalcohol in ozone electrolysis, we knew the fact that increasing carbon number made the decomposition rate slow. 3. According to the treatment of alcohol by ozone electrolysis, decomposition voltage was 50V, time for electrolysis was three hours, and treatment acidity was neutral (pH 6.5 - 8.1). 4. Ozone electrolysis was effective to the phenol treatment. When we treated phenol by using ozone electrolysis for three hours, TOC treatment efficiency was 95%. However, ozone oxidation just showed 45% treatment efficiency.

  • PDF

Ozone Condensation and Stable Supply by an Adsorption Method

  • Yang, Seong-Ho;Park, Yong-Pil;Lee, Joon-Ung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.121-125
    • /
    • 2000
  • An ozone condenser by a selective adsorption on the silica gel surface is constructed. Ozone density is evaluated by three methods; ultraviolet absorption, thermal decomposition and Q-mass analyzing methods. Thermal decomposition method is found to be available to the density evaluation from dilute to highly condensed ozone. The highest ozone density condensed by the adsorption method is evaluated to be 97 mol%.

  • PDF

Ozone Dentisity Estimation and Stable Supply in the Growth Process of BSCCO Thin Film

  • Lee, Hee-Kab;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.45-49
    • /
    • 2000
  • An ozone condenser by a selective adsorption on the silica gel surface is constructed. Ozone density is evaluated by three methods; ultraviolet absorption, thermal decomposition and Q-mass analyzing methods. Thermal decomposition method is found to be available to the density evaluation from dilute to highly condensed ozone. The highest ozone density condensed by the adsorption method is evaluated to be 97 mol%.

  • PDF

Development of Ozone Plasma Sterilizer with Air Circulation Device (공기순환장치 적용 오존 플라즈마 살균장치 개발)

  • An, June;Chun, Young-Nam
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.1
    • /
    • pp.105-110
    • /
    • 2021
  • Objectives: The purpose of this study was to develop a new sterilization plasma device that would be proficient at sterilizing and removing pathogenic bacteria and viruses, and applicable to air purification systems. Methods: In order to understand the performance characteristics, the discharge characteristics of a packed bed DBD reactor and the ozone reduction characteristics of an ozone filter installed at the outlet of the reactor were investigated. Results: The novel packed-bed DBD reactor was proposed, and it was confirmed that the plasma discharge was uniformly and stably discharged throughout the entire layer, and sufficient ozone was generated for sterilization. The ozone filter was tested for three methods: adsorption, adsorption-decomposition, and catalytic decomposition. When the filter thickness was 30 mm, the ozone concentrations were 0.03 ppm, 0.01 ppm, and 0.21 ppm, respectively. The adsorption and adsorption-decomposition methods satisfied the EPA standard of less than 0.05ppm, but the catalytic decomposition method did not. Conclusions: It was confirmed that the adsorption-decomposition method has relatively excellent ozone filter performance and can provide the best ozone filter.

Measurement Technique of Ozone Density by Using UV Sensor System

  • Trung, Nguyen Huu;Van Men, Le;Van Hieu, Nguyen
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.80-86
    • /
    • 2015
  • There are many studies and products using a test paper impregnated with chemical solution can react with ozone. The color of a test paper can indicate the concentration of ozone. The purpose of this research is to design and manufacture a system using ultraviolet light source to measure the ozone density. This new technique is based on the characteristic of decomposition from ozone into oxygen under ultraviolet light. We used two sources of ultraviolet light including UV lamp and UVLED to determine the decomposition of ozone. This system is built with the electronic components, sensors and sealed pump tube to measure the ozone density in units of $g/cm^3$,ppm,ppb. In this paper,, we present some initial results of measuring the ozone density from ozone generator after completing inspection for safety.

Study on the Ozone Generation and Decomposition of Trichloroethylene Using Dielectric Ball Materials filled Barrier Discharge (유전체 볼 충진 배리어 방전을 이용한 오존 생성 및 TCE 분해처리에 관한 연구)

  • Han, Sang-Bo
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.431-437
    • /
    • 2019
  • This work was carried out ozone generation and TCE decomposition characteristics using dielectric ball materials filled barrier discharge reactor and catalyst's reactor for ozone decomposition. Ozone concentration generated from $Al_2O_3$ or $TiO_2$ filled barrier discharge reactor was so high compared with non-filled discharge reactor. This reactor is good discharge structure for generating the high ozone concentration. In addition, TCE decomposition rate and COx conversion rate increased using $MnO_2$ filled discharge reactor, because ozone was decomposed at the same discharge space on the surface of $MnO_2$ catalysts. To identify the $MnO_2$ catalytic effects, TCE decomposition rate reached to 100[%] by the decomposition of ozone at $MnO_2$ catalyst's reactor by the arrangement of $Al_2O_3$ filled discharge reactor and $MnO_2$ catalyst reactor. Finally, $MnO_2$ catalyst is good materials for the decomposition of ozone and this process will be useful for decomposing VOCs such as TCE.

Analysis of Ozone Concentration by TD and Q-mass Method

  • Lee, Dong-Gyu;Lee, Joon-Ung
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.4
    • /
    • pp.161-165
    • /
    • 2004
  • In order to get oxidizing power enough for growth of a superconductive thin film with oxide gas, concentrated ozone was used. As a method for concentrating ozone, a method for concentrating ozone by adsorbing ozone selectively into silica-gel beads is adopted, and this concentration is analyzed by the ultraviolet absorption method, the thermal decomposition method and the Q-mass analyzing method. Thermal decomposition method is most effective for measurement of a high concentration of ozone. Ozone as concentrated by the adsorption method got to have a concentration of 97 mol % at the maximum, and it was identified that the concentration of the ozone gas was stable for the time while a thin film was formed.

Evaluation of Ozone for Metal Oxide Thin Film Fabrication

  • Lim, Jung-Kwan;Park, Yong-Pil;Jang, Kyung-Uk;Lee, Hee-Kab
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.675-678
    • /
    • 2004
  • Ozone is usually generated from oxygen gas using a silent discharge apparatus and its concentration is less then 10 mol%. An ozone condensation system is constructed for metal oxide thin film fabrication. Ozone is condensed by the adsorption method, which is widely used for the growth of oxidation thin films such as superconductor. Highly condensed ozone is analyzed by three methods; ultraviolet absorption, thermal decomposition and Q-mass analyzing methods. Thermal decomposition method is most effective in the highly condensed ozone region and its method is superior to Q-mass analyzer for determining ozone concentration because of the simplicity of the method.

  • PDF