• 제목/요약/키워드: Ozone concentration

검색결과 760건 처리시간 0.025초

연안도시지역 해풍지연이 오존분포에 미치는 영향 (Effects of Late Sea-breeze on Ozone Distributions in the Coastal Urban Area)

  • 오인보;김유근;황미경
    • 한국대기환경학회지
    • /
    • 제20권3호
    • /
    • pp.345-360
    • /
    • 2004
  • The late sea-breeze and its impacts on ozone distributions were investigated during April to September from 1998 to 2002, in the Busan metropolitan area (including surrounding areas) using the surface ozone concentrations (obtained at 9 monitoring sites), local meteorological variables (obtained near the shore), together with synoptic data. The urban scale ozone concentration was also simulated using the MM5/UAM-V to better understand the role of late sea-breeze in Busan. The results from observation study showed that most of the late sea-breeze occurred when weak offshore synoptic flow (northwesterly) suppressed development of sea - breeze, and the ozone concentration level and frequencies exceeding ozone standard increased with the onset time of sea breeze. We also found that the late sea-breeze clearly induces relatively weak wind speed and high temperature during the daytime As a result it enhances the photochemical ozone accumulation and delays the occurrence time of the averaged maximum ozone concentrations. The results of simulation for high ozone episode (24 August, 2001) by MM5/UAM -V revealed that the late sea-breeze interacted with weak offshore synoptic wind can contribute significantly to high ozone concentration in the coastal urban area. The simulated horizontal and vertical distribution of ozone concentration indicated that ozone can be accumulated over the sea under stagnant condition and return to the land in the late afternoon with the sea breeze, suggesting both the relationship between late sea-breeze and recirculation and the importance of late sea -breeze effects influencing severe ozone pollution in Busan.

기단성 뇌우 발생시 지표오존농도의 변화 특성 (Characteristics of the surface ozone concentration on the occurrence of air mass thunderstorm)

  • 전병일
    • 한국환경과학회지
    • /
    • 제12권4호
    • /
    • pp.419-426
    • /
    • 2003
  • This study was performed to research ozone concentration related to airmass thunderstorm using 12 years meteorological data(1990~2001) at Busan. The occurrence frequency of thunderstorm during 12 years was 156 days(annual mean 13days). The airmass thunderstorm frequency was 14 days, most of those occurrence at summertime(59%). In case August 4, 1996, increase of ozone concentration was simultaneous with the decrease of temperature and increase of relative humidity, In case July 23, 1997, ozone concentration of western site at Busan increased, while its of eastern site decreased as airmass thunderstorm occurred(about 1500LST). It is supposed that these ozone increases are the effect of ozone rich air that is brought down by cumulus downdrafts from height levels where the ozone mixing ratio is larger. Thunderstorms can cause downward transport of ozone from the reservoir layer in the upper troposphere into planeta교 boundary layer(PBL). This complex interaction of source and sink processes can result in large variability fer vertical and horizontal ozone distributions. Thus a variety of meteorological precesses can act to enhance vertical mixing between the earth's surface and the atmospheric in the manner described fer thunderstorm.

방전공격과 방전극 형상이 오존발생농도에 미치는 영향 (Effects of Corona Electrode Shape and Discharge Gap Spacing on Ozone Concentration)

  • 박승록;이재찬;정성진;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권4호
    • /
    • pp.169-175
    • /
    • 2001
  • Ozone has been widely applied to many industrial fields because of its strong oxidation power, Therefore, the studies have been carried out for the methods on an effective and high concentration ozone generation. The silent or surface discharge type ozone generators have been mainly used for high concentration ozone generation in many fields of applications. But these two types of ozone generators have shortcomings to be improved. In this study, the ozone generator which improved the shortcomings of above ozone generators was proposed and fabricated for the high concentration ozone generation. And the proposed ozone generator could generate the surface and barrier discharge simultaneously. For this purpose, a mesh type discharge electrode was proposed and studied as a function of the widths output maximum ozone concentration of 2.96[vol%] was obtained at 5.6[kV], 830[mA], for 0.3[mm] width and 0.8[mm] vacancy of the mesh electrode and gap spacing of 0.65[mm] respectively.

  • PDF

금속 산화물 박막 제작을 위한 산화 시스템의 평가 (Evaluation of Oxidation System for Metal Oxide Thin Film)

  • 임중관;유선종;박용필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 제5회 학술대회 논문집 일렉트렛트 및 응용기술연구회
    • /
    • pp.25-28
    • /
    • 2003
  • Ozone is a strong and useful oxidizing gas for the fabrication of oxide thin films. In order to obtain high quality oxide thin films, higher ozone concentration is necessary. In this paper an ozone condensation system was evaluated from the viewpoint of an ozone supplier for oxide thin film growth. Ozone was condensed by an adsorption method and the ozone concentration reached 8.5 mol% in 2.5 h after the beginning of the ozone condensation process, indicating high effectiveness of the condensation process. Ozone was continuously desorbed from the silica gel by the negative pressure. We found the decomposition in the ozone concentration negligible if the condensed ozone is transferred from the ozone condensation system to the film growth chamber within a few minutes.

  • PDF

오존농도의 動態 및 影響因子에 關한 硏究 (Studies on the Behaviour of Ozone Concentration and the Influencing Factors)

  • 金旻永;姜熙坤;李完宗;李相七;張鳳勳;朴聖培
    • 한국대기환경학회지
    • /
    • 제5권2호
    • /
    • pp.55-71
    • /
    • 1989
  • This study was carried out to determine the ozone concentration to behaviour and the factors to be influenced the variation of its concentration in the ambient air in Seoul. Measurements of ozone concentrations were made at 10 monitoring station to take care of SIHE (Seoul Institute of Health & Environment) during December 1987 to November 1988, also measured the hourly average concentration of sulfur dioxide, total suspended particulate, nitrogen oxide $(NO & NO_2)$, carbon monoxide, hydro carbon $(n-CH_4 & THC)$ and meteorological factors, that is, temperature, humidity, wind velocity wind direction and ultraviolet intensity etc, for the same period at same place. The basis of the data obtained were analyzed statistically along with the various data. The results were as follows; 1. The annually arithmetic mean concentration of ozone for the 10 sites during one years was 10.0 ppb and ranged from 3.1 $\pm$ 4.5ppb at the Kuro industrial complex to 17.2 $\pm$ 18.7 ppb at the Ssangmun site. 2. The frequency of hours on which oxidant concentrations exceeded the present short term standard of ozone (100 ppb) were 78 times. 3. The diurnal patterns of hourly ozone concentrations in Seoul area was a typical bi-modal variation which have 4 to 5 a.m. peak and 3. to 4 p.m peak. 4. The time ozone of highest ozone concentration in a whole day and hight was 1 to 5 p.m and 90.9 percent of appearence rate. 5. The diurnal patterns of hourly ozone concentrations in Seoul were on the whole the order of daytime from 5.8ppb to 28.7 ppb evening from 1.7 to 18.7 ppb night time from 1.9 to 9.3 ppb daybreak from 1.4ppb according to measuring sites, and the highest that observed at the Ssangmun area while the lowest was the Kuro industrial complex monitor sites. 6. The weekly variation of ozone concentration was the higher level ozone concentration in the day of the week occured sunday-monday and weekend but the decrease were observed from wednesday to thursday.

  • PDF

반도체 웨이퍼의 오존 수(水) 세정을 위한 고농도 오존발생장치 특성 연구 (A Study on the Characteristics of the High Concentration Ozone Generator for the Semiconductor Wafer Cleaning with the Ozone Dissolved De-ionized Water)

  • 손영수;함상용;문세호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권12호
    • /
    • pp.579-585
    • /
    • 2003
  • Recently the utilization of the ozone dissolved de-ionized water(DI-O3 water) in semiconductor wet cleaning process to replace the conventional RCA methods has been studied. In this paper, we propose the water-electrode type ozone generator which has the ozone gas characteristics of the high concentration and high purity to produce the high concentration DI-O3 water for the silicon wafer surface cleaning process. The ozone generator has the dual dielectric tube structure of silent discharge type and the water is both used to electrode and cooling water. We investigate the performance of the proposed ozone generator which has the design goal of the concentration of 7[wt%] and ozone generation quantity of 6[g/hr] at flow rate of 1[$\ell$/min). The experiment results show that the water electrode type ozone generator has the characteristics of 8.48[wt%] of concentration, 8.08[g/hr] of generation quantity and 76.2[g/kWh] of yield and it's possible to use the proposed ozone generator for the DI-O3 water cleaning process of silicon wafer surface.

금속 산화물 박막제작을 위한 오존 농도 분석 (Analysis of $O_3$ Concentration for Metal Oxide Thin Films Growth)

  • 임중관;박용필;장경욱;이희갑
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.331-332
    • /
    • 2005
  • Ozone is ambient gas which is useful for the fabrication of metal oxide thin films under conditions of molecular beam epitaxy. Ozone is condensed by the adsorption method and its concentration is analyzed using the thermal decomposition method. The concentration of ozone exceeds 90 mol% and ozone is supplied for a sufficiently long time to grow oxide thin films. The ozone concentration is also evaluated using a quadrupole mass analyzer and the accuracy of this method is compared with the results of the thermal decomposition method.

  • PDF

진주시 오존농도의 시간적 추이와 공간적 비교 (Temporal Trends and Spatial Comparisons of Ozone Concentrations in Jinju)

  • 박정호
    • 한국환경과학회지
    • /
    • 제19권6호
    • /
    • pp.761-769
    • /
    • 2010
  • Temporal trends of ozone concentration in Jinju were investigated by using observation data from 3 air quality monitoring stations for the period of 2004~2008. In addition, spatial comparisons of ozone concentration at Jeoguri, upwind and downwind directions of Jinju were investigated between May and September 2009. Annual mean exhibited increasing trends +1.7ppb/yr throughout the study period. In the case of diurnal variation, the lowest ozone concentration was shown from 7 am to 8 am and the highest around 4 pm. The ozone concentrations of Jeoguri station of the south coast were higher than Jinju. In particular, the upwind direction of Jinju had relatively hight ozone concentration

OZIPR을 이용한 부산지역 고농도 오존 사례 모사 (A Numerical Simulation of High Ozone Episode Using OZIPR in Busan)

  • 도우곤;이화운;정우식
    • 한국환경과학회지
    • /
    • 제16권8호
    • /
    • pp.985-994
    • /
    • 2007
  • To investigate the effect of NOx and VOCs(volatile organic compounds) on the generation of high ozone episode, examined the hourly variations of ozone, NOx and VOCs concentrations, and calculated the ozone isopleth about maximum ozone concentrations using OZIPR which was presented by U. S. EPA at three sites in Busan. There was some difference by the sites, but decreasing VOCs concentration was effective for reduction of ozone at 22 July, the episode day of 2005. In the year 2006, the episode day was 8 August and the variations of NOx and VOCs concentration was little than variation of ozone. So it was estimated that the photochemical production of ozone was low than transportation of ozone. And the result of the OZIPR modeling was that decreasing VOCs concentration was effective for reduction of ozone.

고농도 오존일의 강우와 운량 (Precipitation and Cloud Cover on High Ozone Days)

  • 김영성;김영진;윤순창
    • 한국대기환경학회지
    • /
    • 제15권6호
    • /
    • pp.747-755
    • /
    • 1999
  • Effects of precipitation and cloud cover on high ozone days are examined by investigating the precipitation and average cloud cover before the ozone peak time within a day. High ozone days above 100 ppb in the Greater Seoul Area(GSA) for the ozone season from May to September are chosen for the analyses in terms of the surface meteorological data during 1990~1997. The result shows that the effect of precipitation on the rise of ozone concentration is definitely negative so that ozone concentration could not rise above 100ppb immediately after precipitation. But, the effect of cloud cover is associated with the variations of other meteorological parameters. The number of high ozone days with "zero" cloud cover is rather less than that with cloud cover of 1 to 4 since temperature is usually lower in "zero" cloud cover days. Furthermore, ozone concentration can rise above 100ppb even with full cloud cover when the wind is weak and the temperature is high.temperature is high.

  • PDF