• Title/Summary/Keyword: Ozone Treatment

Search Result 556, Processing Time 0.026 seconds

An Experimental Study on the Permeability Evaluation of Metal Spray System by Metal Spray Coating Surface Treatment (콘크리트 표면처리방법에 따른 금속용사 피막의 투수성 평가에 관한 실험적 연구)

  • Park, Jin-Ho;Jang, Hyun-O;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.50-51
    • /
    • 2016
  • Ozone is a strong oxidizing materials in the advanced water treatment facilities. However, due to such a strong oxidation, Ozone eroded waterproofing/corrosion on the concrete surface and caused performance degradation. Therefore, in this study, permeability experiment of metal spraying system by concrete surface treatment was conducted.

  • PDF

Effect of Ozone Treatment on Livestock Drinking Water Quality (오촌처리가 가축 음용수 수질에 미치는 영향)

  • 최희철;이덕수;강희설;최종윤;유용희;한정대;노환국;권두중;김형호
    • Journal of Animal Environmental Science
    • /
    • v.7 no.3
    • /
    • pp.191-195
    • /
    • 2001
  • This research was carried out to investigate the effect of ozone treatment to improve the livestock drinking water quality. Ozone concentration treated was 18.5~36.5ppm in each system. PH and dissolved oxygen(DO) concentration in drinking water was increased by ozone and ozone+anion treatment. But there was no difference in UV used for drinking water treatment. Oxidation and deduction Potential(ORP) was increased while ozone was treated. Colony Forming Unit(CFU) of E. coli 0.8:$H^-$, Salmonella typhimurium, Staphylococcus aureus was decreased after 30 minute to 1 hour ozone and UV treatment.

  • PDF

Optimal Conditions for the Growth of Soybean Sprouts by Ozone Water Watering (오존수 살수(撒水)에 의한 콩나물의 성장조건 최적화)

  • 김일두;김순동
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.11 no.3
    • /
    • pp.219-224
    • /
    • 2001
  • This study was conducted to investigate the optimal conditions for the growth of soybean sprouts by ozone water watering. Optimal conditions for ozone water watering of soybean sprouts during cultivation at 2$0^{\circ}C$ were evaluated with ozone concentration(0.1~O.5 ppm) and watering frequency(1~9 times) by response surface methodology. The optimal conditions for growth of soybean sprouts were ozone concentrations of 0.20~0.32 ppm, ozone treatment frequency of 3.0~4.4 times. Germination rates, hypocotyl weights and hypocotyl lengths in the soybean sprouts cultivated under the optimal conditions increased by 13.3, 10.1 and 11.9%, respectively, whereas root weights decreased by 89.0%.

  • PDF

ULTRAVIOLET MICROSCOPIC STUDY ON LIGNIN DISTRIBUTION IN THE FIBER CELL WALL OF BCTMP

  • Seung-Lak YooN;Yasuo KOJIMA;Lee, Seon-Ho
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 1999.04b
    • /
    • pp.375-380
    • /
    • 1999
  • In order to improve the optical properties of high yield pulp, bleached chemi-thermo-mechanical pulp (BCTMP) was produced from CTMP of Betula maximowicziana Regel by two staged ozone-hydrogen peroxide bleaching. This pulp was used for the evaluation of the improvement of optical properties, chemical characteristics of lignin in fiber, and the relationship between lignin and optical properties in fiber cell wall. By hydrogen peroxide treatment, the brightness was improved, but the post color number (PC No.) was not. There was little improvement on optical properties by ozone treatment, but his could be solved by using two staged ozone-hydrogen peroxide bleaching. The hydrogen peroxide treatment did not make nay change on chemical characteristics of lignin in cell wall, but by ozone treatment, it was found that the non-aromatic conjugated structure was existed in the surface of cell wall, but this could be removed by hydrogen peroxide treatment in two staged ozone-hydrogen peroxide treatment. Therefore, the optical properties was significantly improved due to the removal of non-aromatic conjugated structure.

Change of Microbial Community on Ozonation of Sewage Sludge to Reduce Excess Sludge Production (폐슬러지 감량화 및 재활용을 위한 오존 처리시 하수슬러지내의 미생물 군집구조의 변화)

  • Hong, Jun-Seok;Lim, Byung-Ran;Ahn, Kyu-Hong;Maeng, Sung-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.1
    • /
    • pp.59-65
    • /
    • 2004
  • The change of the microbial community structure in excess sludge of different sewage treatment plants by ozone treatment was investigated by quinone profiles. The resulting ozone dosage ranged from 0.1 to $0.4gO_3/gTS$. In terms of overall sludge reduction, more than 50% reduction of the total sludge mass could be achieved by ozone treatment at $0.4gO_3/gTS$. Quinone concentration and type in sludge of different treatment plants were remarkably decreases with increasing ozone dose. Ubiquinones(UQs)-8, -10 and MK-8 were still remained in the ozonized sludge at $0.4gO_3/gTS$. The results of this study showed that the remaining microorganisms belong to UQs-8, -10 and MK-8 were difficult to destruct cell membrane or wall by ozonation. Fecal Streptococci and Salmonella were not detected at ozone dose of $0.2gO_3/gTS$, but Fecal Coliform was not detected at ozone dose of $0.4gO_3/gTS$.

A Study on the Decomposition Rate of Phenol in the Batch Type Ozonation (회분식 오존 공정에서 페놀의 분해 속도에 관한 연구)

  • 안재동;강동수
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.127-132
    • /
    • 1997
  • The characteristics of the ozone treatments of phenol were studied in a laboratory scale wastewater treatment system. The ozone treatment of wastewater was carried out in a batch-type reactor. The initial pH of wastewater(7-10), volumetric flow rate(1-2l/min) and ozone concentration(20~30 mg/l) of aerating gas were considereal as experimental variables in the ozone treatment. Phenol was decomposed easily by the ozone in a batch treatment, where the rate determining step was the COD removal that is decomposition of intermediates formed by the ozonation of phenol. Phenol decomposition and COD removal could be expressed by the first order reaction for the phenol concentration and COD, respectively. Rate constants of phenol decomposition and COD removal increased with the initial pH, volumetric flow rate and ozone concentration of aeration gas. Under the present experimental condition, their relationships could be given by for the phenol decomposition $k'=4.46\times 10^{-9}[pH]_o ^{3.94}[O_3]^{1.42}Q_{O3}^{1.57}$ for the COD removal $k=2.46\times 10^{-10}[pH]_o ^{5.19}[O_3]^{1.15}Q_{O3}^{1.19}$

  • PDF

Ozone Effects on the Mushrooms Yields (버섯 수량성에 미치는 오존의 영향)

  • Chang, Hyun-You
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.4 no.1
    • /
    • pp.65-69
    • /
    • 2002
  • The objective of this study was to determine mushrooms yields using ozone. The results of this study showed as follows; 1. According to ozone treatment on the Pleurotus ostreatus growth length of stipe became short, diameter of stipe and pileus yields of fruiting body increase 7% than the control treatments. 2. According to ozone treatment on the Agaricus bisporus growth, length of stipe became short, diameter of stipe and pileus became large, yields of fruiting body had increase 4% than the contol treatment. 3. According to ozone treatment on the Flamulina velutipes growth, day required for primordial formation after inoculation(DPI) became late for 2 days.

Consideration about Ozone Generation in the Treatment Room While Treating a Patient (방사선 치료 시 치료실 내에서 발생하는 오존에 관한 고찰)

  • Kwak, Yong-Kuk;Yoon, Il-Kyu;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.75-82
    • /
    • 2009
  • Purpose: Measure the ozone level in the treatment room while treating a patient so want to know the degree of contamination caused by ozone occurrence. Materials and Methods: Use the linear accelerator (Clinac 21EX, Varian, USA) with the ozone meter (series-200, aeroQual, New Zealand) and water phantom (Wellhofer, IBA, Germany) is irradiated the radiation so that measured the ozone generation level according to MU, dose-rate, SSD, field size, energy, delay time and put the ozone meter in the treatment room actually while treating a patient so measured the daily ozone level variation. Results: While irradiating the radiation, degree of ozone contamination wasn't affected by the energy but mostly in case of electron beam, ozone level was higher than photon beam. The higher dose-rate (0.016~0.025 ppm/hr), the farther SSD (0.018~0.030 ppm/hr), the wider field sizes (0.016~0.025 ppm/hr), the more MU (0.018~0.046 ppm/hr), it occurred high ozone level. Ozone decrement according to delay time changed the background level (0.016 ppm/hr) after elapsed time of 10 minutes from irradiating radiation. And daily ozone occurrence level in the treatment room was below ozone standard level 0.1 ppm/hr (average:0.06 ppm/8 hr) but it could confirm that ozone generation level was included the level (max:0.038 ppm/hr) above 0.02 ppm/hr which patient could perceive. Conclusion: Through ozone level according to variation of certain conditions, actually in the treatment room ozone generation level didn't damaged to patients or workers. Commonly peoples think that ozone was harmful gas but it thought that small amount of ozone generation level while treating a patient was beneficial in the treatment room through air purge action of pathogenic germ or virus sterilization.

  • PDF

The Efficacy of Ozone Ointment Therapy on Pododermatitis of Dairy Cows (젖소 족피부염(足皮膚炎)에 대한 오존연고의 치료(治療) 효과(效果))

  • Lee, Soo-Jin;Jun, Moo-Hyung;Cho, Sung-Whan;Kim, Duck-Hwan;Park, Chang-Sik;Kim, Myung-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.23 no.3
    • /
    • pp.279-285
    • /
    • 2006
  • Thirty dairy cows with pododermatitis were selected and treatment effect of ozone ointment for bovine pododermatitis was investigated. In addition, bactericidal effect of ozone ointment on etiological agent of bovine pododermatitis was evaluated. The pathohistological examination for the pododermatitis, according to application with ozone ointment was investigated. Thirty dairy cows were divided two groups: control group(vaseline group: 15 cows), treatment group(ozone ointment group: 15 cows). Various parameters were evaluated in terms of the lameness score, swelling score, lesion score, WBC, neutrophil, pathohistological finding, and antimicrobial action. As compared with vaseline group, ozone ointment group revealed significant decrease of lameness(p<0.05), swelling(p<0.01) and lesion score(p<0.05) were shown in hoof lesions on 14 days after application. In hematological findings, WBC count revealed slightly high values within normal range before treatment, however, this was 1Corresponding author improved on 14 days after application of ozone ointment. The number of neutrophils was slightly higher than that of normal, however, this was improved on 14 days after application of ozone ointment. In pathohistological findings, normal dermal tissue was found in tissues with pododermatitis on 14 days after application of ozone ointment. In antimicobial action, marked decrease rate of bacteria was observed in feet of all cases treated with ozone ointment. The decreasing rate of bacteria in anaerobic culture was higher than that in aerobic culture.

Study on performance improved design of pressure-type ozone contactor in multistorey water treatment plant by CFD (CFD에 의한 수직형 정수처리 실증시설 내 압력식 오존접촉조 성능개선에 관한 연구)

  • Choi, Jong-Woong;Kim, Seong-Su;Kim, Jeong-Hyun;Kim, Kwanyeop
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.4
    • /
    • pp.431-440
    • /
    • 2014
  • The ozonation process has been widely used for drinking water disinfection around the world. Recently, the pressurized ozone contactor, in which the side stream typed ozone injection method is installed, has been applied to water treatment system. In this study, numerical calculations were conducted to compare prototype and screw-type ozone contactors based on hydraulic effectiveness in more details. The prototype ozone contactor was already installed and operated in domestic water treatment plant, and the screw-type is the suggested one for improving ozone contact efficiency installing the screw plate to the prototype. Screw turn numbers of screw plate were changed as 3, 5, 7 and 9, respectively for numerical simulation. The CT(concentration of disinfectant in mg/L times time in minutes) value was considered as one of the options for evaluating disinfection ability. From the results, it could be concluded that the performance of the screw-type is higher than that of the protype contactor by controlling the variable T as the tracer time. Also, Morill index of the screw-type(turn numbers = 5 ) appeared to be lower than the other.