• 제목/요약/키워드: Ozone Decomposition

검색결과 122건 처리시간 0.024초

연속식 PCR과 BCR에서 페놀 농도 증가에 따른 오존 처리 특성에 관한 연구 (A Study on the Ozonation Characteristics of the Phenol Contaminated Wastewater by Increasing Phenol Concentration in the Continuous PCR and BCR)

  • 김용대;안재동;이준
    • 한국환경보건학회지
    • /
    • 제21권2호
    • /
    • pp.12-19
    • /
    • 1995
  • The objectives of this research prograln were to study the ozonation characteristics of phenol contaminated wastewater in the continuous packed column reactor (PCR) and the bubble column reactor (BCR) using ozone that has a strong oxidizing potential, and to provide the fundamentals of ozonizing the phenol contaminated wastewater. Among various influencing factors on phenol decomposition through the oxidation by ozone, phenol/ozone mde ratio was chosen as reaction parameters. Concerning the phenol/ozone mde ratio, as the influent phenol concentration increased from 30 mg/l to 150 mg/l, the phenol removal efficiency decreased from 99% for 30 mg/l to 83.7% for 150 mg/l, in PCR. PCR also showed higher treatment efficiency than BCR by 1% for 30 mg/l and 2.2% for 150 mg/l, respectively. The ozone utilization efficiency of PCR for the phenol concentration 30 mg/l was higher than that of BCR while the efficiency of both reactors was 99.9% for the phenol concentration of 150 mg/l.

  • PDF

대두 발아중 오존수 처리가 acid phoshatase 및 배유세포의 형태학적인 변화 (Ozone-water Treatment on the Morphological Changes of Endosperm cell and the activity of Acid Phosphatase during Soybean(Glycine max) Germination)

  • 박홍덕
    • 생명과학회지
    • /
    • 제11권5호
    • /
    • pp.489-495
    • /
    • 2001
  • 대두 발아종 오존수 처리에 의한 배유세포와 산성 인산호효소의 변화에 관해서 전자현미경으로 조사한 결과는 다음과 같다. 산성 인산화효소의 활성은 발달하고 있는 종자 배유의 여러 소기관에 나타났는데, 효소의 활성은 0.5 ppm 오존수를 처리한 후 12시간 배양중에 나타났다. 오존수를 처리한 후 배유가 분화함에 따라 산성 인산화효소의 반응산물은 액포내에 축적되는 것으로 나타나는데, 이것은 산성 인산화효소가 세포간 저장물질의 분해와 이동에 관여하는 것으로 여겨진다.

  • PDF

연속식 PCR과 BCR에서 pH 변화에 따른 페놀 폐수의 오존처리특성에 관한 연구 (The Characteristics of the Ozonation of phenol wastewater by the variation of pH using the continuous PCR and BCR)

  • 안재동;김민수;김용대;최석규
    • 한국환경보건학회지
    • /
    • 제23권1호
    • /
    • pp.74-80
    • /
    • 1997
  • This study was performed to estimate the ozonation characteristics of phenol wastewater with increasing pH in the continuous packed column reactor (PCR) and the bubble column reactor (BCR). Among various influencing factors that affect phenol on decomposition through the ozonation, pH was chosen as reaction parameter. Upon increasing pH from 3 to 9, the phenol removal efficiency in PCR was improved approximately by 17% while in BCR approximately by 19.2%. The improvements in the phenol removal efficiency by increasing pH caused the enhancements in ozone utilization efficiency reaching almost 100% in PCR at pH 9. In conclusions, ozone has latent power for phenol wastewater treatment, and the performance of PCR was superior to that of BCR in the aspects of phenol removal and ozone utilization efficiency.

  • PDF

Ozone kinetics and Diesel decomposition by Ozonation in Groundwater

  • Kwon, Choong-Il;Kong, Sung-Ho;Kim, Moo-Hoon
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 창립총회 및 춘계학술발표회
    • /
    • pp.153-156
    • /
    • 2000
  • 본 연구에서는 지하수내에서의 오존의 거동과 오존산화공정에 의한 디젤의 분해를 조사하였다. 오존의 초순수와 지하수내에서의 반응은 모두 2차 분해반응속도식을 나타냈고, 초순수와 지하수내에서의 반감기는 각각 평균 37.5분, 14.7분으로 계산되었다. 지하수내에서 오존의 자가분해반응속도가 더 빠른 것으로 나타났는데 이는 오존이 지하수내에 존재하는 각종 유기·무기물질들과의 빠른 반응때문이라고 생각된다. 오존의 TCE, PCE 그리고 디젤의 빠른 제거효율을 통하여 디젤로 오염된 지하수를 처리하는데 있어서 오존산화공정은 효과적으로 적용될 수 있을 것이라 판단된다.

  • PDF

방전Plasma 반응에 의한 NOx의 안전처리에 관한 연구 (A Study on Safety Treatment of NOx by Discharge Plasma Reaction)

  • 최재욱;야마구마 미즈키
    • 한국안전학회지
    • /
    • 제15권2호
    • /
    • pp.92-96
    • /
    • 2000
  • In this experiment, we studied about concentration characteristics of $NO_x$ and generation of ozone in the reactor of corona discharge type by using mixed gas of $NO/N_2$ and $N_2/O_2$. In the case of the initial NO concentration increased, decrease rate of NO concentration was weakened and discharge input power of minimum NO concentration became high. When NO concentration was high, NO decomposition limit was appeared. And NO reduction rate was decreased, when initial NO concentration and discharge input power increased. When discharge input power was 5W, we could know the most proper energy value for treatment of NO. When the concentration of initial NO increased, generation of ozone decreased and in the case of same concentration of NO, according to discharge input power increase, generation of ozone increased.

  • PDF

통계적 방법을 이용한 동남아시아지역 위성 대기오염물질 분석과 검증 (Analysis of Characteristics of Satellite-derived Air Pollutant over Southeast Asia and Evaluation of Tropospheric Ozone using Statistical Methods)

  • 백강현;김재환
    • 한국대기환경학회지
    • /
    • 제27권6호
    • /
    • pp.650-662
    • /
    • 2011
  • The statistical tools such as empirical orthogonal function (EOF), and singular value decomposition (SVD) have been applied to analyze the characteristic of air pollutant over southeast Asia as well as to evaluate Zimeke's tropospheric column ozone (ZTO) determined by tropospheric residual method. In this study, we found that the EOF and SVD analyses are useful methods to extract the most significant temporal and spatial pattern from enormous amounts of satellite data. The EOF analyses with OMI $NO_2$ and OMI HCHO over southeast Asia revealed that the spatial pattern showed high correlation with fire count (r=0.8) and the EOF analysis of CO (r=0.7). This suggests that biomass burning influences a major seasonal variability on $NO_2$ and HCHO over this region. The EOF analysis of ZTO has indicated that the location of maximum ZTO was considerably shifted westward from the location of maximum of fire count and maximum month of ZTO occurred a month later than maximum month (March) of $NO_2$, HCHO and CO. For further analyses, we have performed the SVD analyses between ZTO and ozone precursor to examine their correlation and to check temporal and spatial consistency between two variables. The spatial pattern of ZTO showed latitudinal gradient that could result from latitudinal gradient of stratospheric ozone and temporal maximum of ZTO in March appears to be associated with stratospheric ozone variability that shows maximum in March. These results suggest that there are some sources of error in the tropospheric residual method associated with cloud height error, low efficiency of tropospheric ozone, and low accuracy in lower stratospheric ozone.

AOP에 의한 1,4-다이옥산의 처리 특성에 관한 연구 (Treatment Characteristics of 1,4-Dioxane by Advanced Oxidation Process System)

  • 이수;강학수;최재혁
    • 한국응용과학기술학회지
    • /
    • 제25권1호
    • /
    • pp.32-40
    • /
    • 2008
  • 1,4-Dioxane is an EPA priority pollutant often found in contaminated ground waters and industrial effluents. Conventional water treatment techniques are limited to decompose this compound effectively. Therefore, an advanced oxidation process system (AOP) was used for the degradation of 1,4-dioxane. This research investigates the effect of adding oxidants, such as ozone, air, and $H_2O_2$ during the UV irradiation of 1,4-dioxane solution. In order to analyze 1,4-dioxane, a modified 8270 method, which is an improved method of U.S EPA 8720, was used. Degradation efficiencies of 1,4-dioxane by only UV irradiation at various temperatures were not significant. However, The addition of oxidants and air bubbling in the UV irradiation system for 1,4-dioxane decomposition showed the higher 1,4-dioxane degradation rate. And, during AOP treatment the tendency of TOC changes was similar to that of 1,4-dioxane decomposition rate.

오존 처리 및 UV 조사를 이용한 Sulfamethoxazole 제거; 동역학적 고찰 및 pH 영향 (Removal of Sulfamethoxazole using Ozonation or UV Radiation; Kinetic Study and Effect of pH)

  • 정연정;김완기;장하영;최양훈;오병수;강준원
    • 한국물환경학회지
    • /
    • 제24권1호
    • /
    • pp.63-68
    • /
    • 2008
  • This study was performed to assess the potential use of ozone or UV radiation for the treatment of water contaminated with sulfamethoxazole (SMX), which is frequently used antibiotic in human and veterinary medicines, especially focusing on the kinetic study and effect of pH. In a study using ozone alone, kinetic study was performed to determine second-order rate constant ($k_{O3,SMX}$) for the reactions of SMX with ozone, which was found to be $1.9{\times}10^6M^{-1}s^{-1}$ at pH 7. The removal efficiencies of SMX by ozone were decreased with increase of pH due to rapid decomposition of ozone under the condition of various pH (2.5, 5.3, 7, 8, 10). In a UV irradiation study at 254 nm, a kinetic model for direct photolysis of SMX was developed with determination of quantum yield ($0.08mol\;Einstein^{-1}$) and molar extinction coefficient ($15,872M^{-1}cm^{-1}$) values under the condition of quantum shielding due to the presence of reaction by-products formed during photolysis. For effect of pH on photolysis of SMX, SMX in the anionic state ($S^-$, pH > 5.6), most prevalent form at environmentally relevant pH values, degraded more slowly than in the neutral state (SH, 1.85 < pH < 5.6) by UV radiation at 254 nm.

SBT 강유전체 충전층 저온 플라즈마 반응기의 전기적 특성, 오존생성 및 휘발성유기화합물의 분해 (Characteristics of Electrical Properties, Ozone Generation and Decomposition of Volatile Organic Compounds by Nonthermal Plasma Reactor Packed with SBT Ferroelectric)

  • 어준;김일원;박진도;이주영;이학성
    • 공업화학
    • /
    • 제22권3호
    • /
    • pp.249-254
    • /
    • 2011
  • Ferroelectric의 강유전체 소구들을 충전한 원통형의 비열 방전 플라즈마 반응기를 설계 제작하였으며, 강유전체 층방전 구조를 구성하는 평판(20 mm 간격) 금속망 전극 사이에 직경 2.0 mm인 $SrBiTaO_9$ (SBT) 소구들을 위치시키고 고압의 교류 전원을 인가하였다. SBT 소구는 상온($25^{\circ}C$)에서 150, 큐리온도($335^{\circ}C$)에서 500의 유전상수를 가졌다. 플라즈마 반응기에서 오존 생성속도는 거의 인가전압의 증가에 비례하였으며, SBT 소구들이 충전된 경우, 20 kV 이상의 인가전압에서 오존 생성속도는 급격하게 증가하였다. 부코로나 방전에서 오존 생성속도가 정코로나 방전에서의 경우보다 높았다. 그러나 톨루엔 및 메틸렌클로라이드의 분해율은 생성된 오존 농도에 비례하여 증가하지 않았다.

Photocatalytic Decomposition of Gaseous Ozone over $TiO_2$Thin Film

  • Cho, Ki-Chul;Hwang, Kyung-Chul;Yeo, Hyun-Gu;Taizo Sano;Koji Takeuchi;Sadao Matsuzawa
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제19권E3호
    • /
    • pp.121-127
    • /
    • 2003
  • The characteristics of heterogeneous photocatalytic decomposition were investigated at low concentration level of $O_3$on TiO$_2$for various operating parameters such as: loaded catalyst weight (0∼4 mg/$\textrm{cm}^2$), initial concentration of $O_3$(0.06∼10.0 ppm), gas flow rate (1.0 ∼ 2.5ι/min), and relative humidity (0∼80%). This study was conducted using a flow-type reactor at room temperature. Three kinds of pure TiO$_2$(P25, ST -01, and E- 23) were employed as photocatalyts. It was found that $O_3$removal ratio was identical, regardless of the loaded TiO$_2$weight in the range from 0.5 to 4.0 mg/$\textrm{cm}^2$. It was also found that higher initial ozone concentration results in greater oxidation rate of ozone and experimental data show kinetically a good agreement with Langmur-Hinshelwood kinetic model. We also observed that the removal ratio of $O_3$increases linearly with the increasing flow rate and also with the increasing relative humidity for each catalyst.