• Title/Summary/Keyword: Oxygen electrode system

Search Result 109, Processing Time 0.069 seconds

다기능 산소전극에 의한 산소투과특성 동시측정 (Simultaneous measurement of oxygen permeability by using of multi-functional oxygen electrode)

  • 이동희;정진휘;유형풍;김태진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.532-535
    • /
    • 2000
  • We have fabricated a sensor system for on-line monitoring the oxygen permeability and diffusivity of six different polymer films using the miniaturized 6 cathode(Ag)-single anode(Ag/AgCl) type hexagonal oxygen electrode. This system consists of multiple input front-end electronics, signal conditioning circuit using the embedded microcontroller 80C196KC, PC interface circuit and PC with the OS for microcontroller and the operating program for this system. The digital low-[ass filter was programmed and the simulated filter characteristics were enough to eliminate the noise from sensor signal. According to the experimental results, the linearity coefficients of the output voltage to oxygen partial pressure for each sensor electrode of six cathode type oxygen sensor are 0.998, 0.997, 0.998, 0.997, 0.997, 0.997 respectively, and the response times are all within 4 minutes.

  • PDF

A Review of Ac-impedance Models for the Analysis of the Oxygen Reduction Reaction on the Porous Cathode Electrode for Solid Oxide Fuel Cell

  • Kim, Ju-Sik;Pyun, Su-Il
    • 전기화학회지
    • /
    • 제8권2호
    • /
    • pp.106-114
    • /
    • 2005
  • This article covers the theoretical ac-impedance models for the analysis of oxygen reduction on the porous cathode electrode f3r solid oxide fuel cell (SOFC). Firstly, ac-impedance models were explained on the basis of the mechanism of oxygen reduction, which were classified into the rate-determining steps; (i) adsorption of oxygen atom on the electrode surface, (ii) diffusion of adsorbed oxygen atom along the electrode surface towards the three-phase (electrode/electrolyte/gas) boundaries, (iii) surface diffusion of adsorbed oxygen atom m ixed with the adsorption reaction of oxygen atom on the electrode surface and (iv) diffusion of oxygen vacancy through the electrode coupled with the charge transfer reaction at the electrode/gas interface. In each section for ac-impedance model, the representative impedance plots and the interpretation of important parameters attributed to the oxygen reduction reaction were explained. Finally, we discussed in detail the applications of the proposed theoretical ac-impedance models to the real electrode of SOFC system.

산화물기반 박막트랜지스터 전극용 ITO박막의 제작시 투입 산소 분압 의존성 (Dependency of Oxygen Partial Pressure of ITO Films for Electrode of Oxide-based Thin-Film Transistor)

  • 김경환
    • 반도체디스플레이기술학회지
    • /
    • 제20권2호
    • /
    • pp.82-86
    • /
    • 2021
  • In this study, we investigated the oxygen partial pressure effect of ITO films for electrodes of oxide-based Thin-Film Transistor (TFT). Firstly, we deposited single ITO films on the glass substrate at room temperature. ITO films were prepared at the various partial pressures of oxygen gas 0-7.4% (O2/(Ar+O2)). As increasing oxygen on the process of film deposition, electrical properties were improved and optical transmittance increased in the visible light range (300-800 nm). For the electrode of TFT, we fabricated a TFT device (W/L=1000/200 ㎛) with ITO films as the source and drain electrode on the silicon wafer. Except for the TFT device combined with ITO film prepared at the oxygen partial pressure ratio of 7.4%, We confirmed that TFT devices with ITO films via FTS system operated as a driving device at threshold voltage (Vth) of 4V.

Electrocatalysis of Oxygen Reduction by Au Nanoparticles Electrodeposited on Polyoxometalate-Modified Electrode Surfaces

  • Choi, Kyung-Min;Choi, Su-Hee;Kim, Jong-Won
    • 전기화학회지
    • /
    • 제12권1호
    • /
    • pp.75-80
    • /
    • 2009
  • The effect of polyoxometalate monolayers on the electrodeposition of Au nanoparticles (AuNPs) on glassy carbon (GC) surfaces was examined by electrochemical and scanning electron microscope techniques. The presence of $SiMo_{12}O^{4-}_{40}$-layers resulted in average particle sizes of ca. 60 nm, which is larger than AuNPs deposited on bare GC surfaces. AuNPs electrodeposited on $SiMo_{12}O^{4-}_{40}$-modified GC surfaces for 20 s exhibited the best electrocatalytic activity for oxygen reduction. This system exhibited similar or slightly better efficiency for oxygen reduction than a bare Au electrode. Rotating disk electrode experiments were also performed and revealed that the catalytic reduction of oxygen on AuNPs deposited on $SiMo_{12}O^{4-}_{40}$-modified GC electrodes is a two-electron process.

FET형 용존산소 센서 어레이 측정시스템 (A Dissolved Oxygen Measurement System Using FET-type Dissolved Oxygen Sensor Array)

  • 정훈;손병기
    • 센서학회지
    • /
    • 제10권4호
    • /
    • pp.259-265
    • /
    • 2001
  • FET형 용존산소 센서는 pH-ISFET를 기본 소자로하여 pH 감지 게이트 근처에 백금으로 된 작업 전극을 형성한 구조를 가지고 있다. 작업전극에 특정한 전위를 인가하면 전기분해로 인하여 용존산소의 농도에 비례하는 수소 이온이 pH 감지 게이트 주변에 발생된다. 따라서 pH-ISFET를 통하여 수소 이온 농도의 변화량을 검출하면 용존산소의 농도를 측정할 수 있게된다. 본 논문에서는 이러한 FET형 용존산소 센서를 어레이 형태로 제작하여 적용하고 측정의 신뢰성을 높이기 위한 알고리즘을 도입한 FET형 용존산소 센서 어레이 측정 시스템을 개발하였다. 또한 상용 용존산소 측정기와 그 성능을 비교 분석하였다.

  • PDF

고분자 전해질 막을 이용한 일체형 재생 연료전지용 촉매전극 개발 (Development of Bifunctional Electrocatalyst for PEM URFC)

  • 임성대;박구곤;손영준;양태현;윤영기;이원용;김창수
    • 한국수소및신에너지학회논문집
    • /
    • 제15권1호
    • /
    • pp.23-31
    • /
    • 2004
  • For the fabrication of high efficient bifunctional electrocatalyst of oxygen electrode for PEM URFC (Polymer Electrolyte Membrane Unitized Regenerative Fuel Cell), which is a promising energy storage and conversion system using hydrogen as the energy medium, several bifunctional electrocatalysts were prepared and tested in a single cell URFC system. The catalysts for oxygen electrode revealed fuel cell performance in the order of Pt black > PtIr > PtRuOx > PtRu ~ PtRuIr > PtIrOx, whereas water electrolysis performance in the order of PtIr ~ PtIrOx > PtRu > PtRuIr > PtRuOx ~ Pt black. Considering both reaction modes PtIr was the most effective elctrocatalyst for oxygen electrode of present PEM URFC system. In addition, the water electrolysis performance was significantly improved when Ir or IrOx was added to Pt black just 1 wt.% without the decrease of fuel cell performance. Based on the catalyst screening and the optimization of catalyst composition and loading, the optimum catalyst electrodes for PEM URFC were $1.0mg/cm^2$ of Pt black as hydrogen electrode and $2.0mg/cm^2$ of PtIr (99:1) as oxygen electrode.

전극표면 연마 유니트를 이용한 전기화학적 COD측정용 센서의 개발 (Development of a COD(Chemical Oxygen Demand) Sensor Using an Electrode-surface Grinding Unit)

  • 윤석민;최창호;박병선;진길주;정봉근;현문식;박종만;이승선;이동희;김형주
    • 대한환경공학회지
    • /
    • 제28권4호
    • /
    • pp.453-458
    • /
    • 2006
  • 수질의 빠르고 정확한 COD(Chemical Oxygen Demand)의 측정을 위하여 전극표면 연마장치가 부착된 전기화학적 측정 센서시스템을 연구하였다. 수질 내 유기물에 대한 Cu의 산화작용이 COD 측정의 기본원리로 이용되었으며, 3전극계를 적용한 전기화학 셀을 COD 측정시스템에 적용하였다. 장시간의 COD 측정에 대비하여, Cu전극의 내구성과 안정성을 유지시키기 위해 회전되는 연마석을 이용한 자동연마장치를 부착하였다. 유기물을 함유한 인공시료 및 실제 현장시료를 이용하여 COD 변화에 대한 측정가능성을 실험하였고, $COD_{Mn}$ 수치와 COD 측정용 센서를 이용하여 측정한 Coulombic yield와의 사이에 높은 상관관계($r^2=0.93$)를 가지며 이 측정값을 EOD(electrochemical oxygen demand)로 표현할 수 있다는 것을 확인하였다. 이러한 측정 결과를 토대로 이 시스템이 폐수처리장 및 하수에 연속 COD 측정 장치로 적용할 수 있는 가능성이 있을 것으로 확인하였다.

Zr-based 수소저장합금을 음극으로 사용한 밀패형 Ni-MH 2차전지의 내압특성에 관한 연구 (A study on the characteristics of inner cell pressure for sealed type Ni-MH rechargeable battery using Zr-based hydrogen storage alloy as anode)

  • 김동명;이호;장국진;이재영
    • 한국수소및신에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.79-90
    • /
    • 1997
  • Extensive work has been done on investigating the inner cell pressure characteristics of sealed type Ni-MH battery in which Zr-Ti-Mn-V-Ni alloy is used as anode. The inner cell pressure of this type Ni-MH battery much more increases with the charge/discharge cycling than that of the other type Ni-MH battery where commercialized $AB_5$ type alloy is used as anode. The increase of inner cell pressure in the sealed type Ni/MH battery using Zr-Ti-Mn-V-Ni alloy system is mainly due to the accumulation of oxygen gas during charge/discharge cycling. The accumulation of oxygen gas arises mainly due to the low rate of oxygen recombination on the MH electrode surface during charge/discharge cycling. The difference of oxygen recombination rate between $AB_5$ type electrode and Zr-Ti-Mn-V-Ni electrode is caused by the difference of electrode reaction surface area resulting from different particle size after their activation and the difference of surface catalytic activity for oxygen recombination reaction, respectively. After EIS analysis, it is identified that the surface catalytic activity affects much more dominantly on the oxygen recombination reaction than the reaction surface area does. In order to suppress the inner cell pressure of Ni-MH battery where Zr-Ti-Mn-V-Ni is used as anode, it is suggested that the surface catalytic activity for oxygen recombination should be improved.

  • PDF

펄스전압의 극성에 따른 액중 전위변화에 관한 연구 (A Study on Electric Potential Change by Pulse Voltage Polarity in Liquid)

  • 김진규;김형표;박영호
    • 조명전기설비학회논문지
    • /
    • 제19권4호
    • /
    • pp.79-84
    • /
    • 2005
  • 본 논문은 액중 이온교환수 발생장치 내에 양${\cdot}$음이온교환격막을 중심으로 불평등전계를 형성할 수 있는 사선빗살형 전극을 설치하였다. 그리고 정극성과 부극성의 펄스전압을 인가하여 펄스전압의 극성변화에 의한 산화환원전위 변화가 이온교환수 발생장치 내에서 발생된 용존산소량에 미치는 영향을 비교 검토하였다. 실험결과, 이온교환수 발생장치 내에 인가된 펄스전압의 극성변화와 전기비저항의 차에 의한 산화환원전위 및 용존산소농도 변화를 관찰할 수 있었다. 그리고 인가된 펄스전압의 극성변화와 전기 비저항 차에 의한 전위변화가 용존산소농도를 증가시켜 액중에서 고농도의 이온들을 생성시킴을 알 수 있었다.

생체 삽입형 유연한 마이크로 전극의 제작 및 평가 (Fabrication and Evaluation of the Flexible and Implantable Micro Electrode)

  • 백주열;권구한;이상운;이기암;이상훈
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권2호
    • /
    • pp.93-99
    • /
    • 2006
  • In this paper, we fabricated and evaluated polydimethylsiloxane(PDMS)-based flexible and implantable micro electrodes. The electrode patterning was carried out with the photolithography and chemical etching process after e-beam evaporation of 100 ATi and 1000 A Au. The PDMS substrate was treated by oxygen plasma using reactive ion etching(RIE) system to improve the adhesiveness of PDMS and metal layers. The minimum line width of fabricated micro electrode was 20 $\mu$m. After finished patterning, we did packaging with PDMS and then brought up the electrode's part about 40 $\mu$m with gold electroplating. The Hank's balanced salt solution(HBSS) test was carried out for 6 month for endurance of fabricated micro electrode. We carried out in-vivo test for the evaluation of biocompatibility by implanting electrodes under the ICR mouse skin for 42 days.